logo
Henan Hongtai HVAC Equipment Co., Ltd.
Products
Products
Home > Products > DC Inverter VRF > HighRise VRF 8-80HP 250Pa External Static Tower Solution 250 Pascal of External Static Pressure Push Airflow to the Top Floor Without a Second Outdoor Unit

HighRise VRF 8-80HP 250Pa External Static Tower Solution 250 Pascal of External Static Pressure Push Airflow to the Top Floor Without a Second Outdoor Unit

Product Details

Place of Origin: China

Brand Name: OEM;MIDEA

Certification: CB,ISO

Payment & Shipping Terms

Get Best Price
Highlight:

VRF system with 250Pa static pressure

,

DC inverter VRF tower solution

,

HighRise VRF 8-80HP air handler

Product Name:
V8 Master
Cooling Capacity:
5,000-26,000W
Capacity Range:
8-80HP
Power Supply:
180-440V, Dual Frequency 50/60Hz, Generator Compatible
Positioning:
High-Rise Specialist VRF
Refrigerant:
R410A
Climate Rating:
T3 — 52 Deg C High Ambient Cooling
Product Name:
V8 Master
Cooling Capacity:
5,000-26,000W
Capacity Range:
8-80HP
Power Supply:
180-440V, Dual Frequency 50/60Hz, Generator Compatible
Positioning:
High-Rise Specialist VRF
Refrigerant:
R410A
Climate Rating:
T3 — 52 Deg C High Ambient Cooling
HighRise VRF 8-80HP 250Pa External Static Tower Solution 250 Pascal of External Static Pressure Push Airflow to the Top Floor Without a Second Outdoor Unit
HighRise VRF 8-80HP 250Pa External Static Tower Solution
250 Pascal of External Static Pressure Push Airflow to the Top Floor Without a Second Outdoor Unit
Product Overview
High-rise VRF installations present unique challenges that standard systems cannot address: vertical refrigerant piping runs exceeding standard height limits, rooftop outdoor units exposed to extreme conditions, and duct runs so long that standard static pressure cannot deliver airflow to upper floors. The V8 Master was specifically developed to overcome these constraints with a single outdoor unit solution, eliminating the need for intermediate mechanical floors or redundant outdoor placements.
The standout capability is 250Pa of external static pressure—roughly double what standard VRF outdoor units provide. This enables rooftop-mounted outdoor units to push conditioned air through long duct runs to the highest floors without booster fans, intermediate duct sections, or the associated installation labor, electrical connections, and maintenance access points. For contractors, this means fewer equipment items to install, wire, program, and warranty.
Covering 8-80HP with the same ShieldBox IP55 protection, SuperSense monitoring, and BMS integration found across the V8 family, the V8 Master brings high-rise expertise without requiring contractors to learn an entirely different system. The crews and procedures you already know apply directly—the difference is that this equipment can reach where others cannot.
Key Features
250Pa External Static Pressure – Rooftop to Top Floor Without Boosters
Most VRF outdoor units deliver 80-120Pa of external static pressure, requiring booster fans or multiple outdoor unit placements at intermediate levels to serve high-rise buildings. The V8 Master generates 250Pa—more than double the typical output—enabling a single rooftop installation to push conditioned air through extended ductwork to the uppermost floors without any intermediate equipment.
  • 250Pa external static pressure eliminates booster fan requirements on floors up to 40+ stories
  • Single rooftop outdoor unit serves the entire building height—no intermediate mechanical floors needed
  • Eliminates booster fan installation labor, electrical connections, and ongoing maintenance
  • Reduces total equipment count per project, simplifying procurement and spare parts management
  • Fewer equipment items means fewer warranty exposure points and service calls
  • Enables cleaner architectural design without visible intermediate outdoor unit placements
ShieldBox IP55 – Engineered for Rooftop Exposure
High-rise rooftop installations expose outdoor units to conditions far more punishing than ground-level placement: sustained high winds, sand and dust driven at velocity, UV degradation, rain driven horizontally by wind, and temperature extremes amplified by reflected solar radiation. The V8 Master's ShieldBox IP55 construction seals every electrical compartment against these conditions, maintaining reliable operation where lesser equipment would fail.
  • Complete IP55 sealing prevents wind-driven dust, sand, and rain penetration
  • Electrical compartment actively cooled by refrigerant flow through micro-channel heat exchangers
  • Circuit board semiconductor junctions maintained within optimal temperature range above 50°C outdoor
  • Sealed cable entries eliminate sand, dust, and insect intrusion pathways
  • Validated across desert high-rises, tropical coastal towers, and industrial-zone installations
  • Reduces rooftop service calls—the harshest installation location becomes the most reliable
SuperSense Monitoring – Remote Diagnostics That Reduce Service Truck Rolls
When a high-rise building's climate system shows an anomaly, the cost of a service visit includes elevator access, rooftop rigging, diagnostic equipment transport, and potential tenant disruption. The V8 Master's SuperSense array of precision sensors positioned throughout the refrigerant circuit enables remote monitoring that can often diagnose issues without dispatching a truck, or ensures the technician arrives with the right parts on the first visit.
  • Precision sensors at critical measurement points enable comprehensive remote health assessment
  • Real-time data accessible through mobile app—diagnose before dispatching a service team
  • Predictive algorithms identify developing issues 48-72 hours before they become service calls
  • Automatic fault isolation narrows the problem to a specific component before the truck rolls
  • Historical data logging supports root cause analysis and preventive maintenance scheduling
  • First-visit fix rate improves dramatically when the technician arrives knowing exactly what needs replacement
META 2.0 Algorithmic Control – Set-and-Forget Performance
The V8 Master's META 2.0 control system operates as a continuous optimization engine, adjusting refrigerant flow, suction temperature, and fan speed in real time based on actual building thermal behavior. For contractors, this means the system tunes itself after commissioning—no seasonal manual adjustments, no return visits to re-balance capacity, no client complaints about comfort drift as building occupancy patterns change.
  • Three-variable optimization runs continuously—the system self-tunes after initial commissioning
  • Adapts to building thermal mass, occupancy patterns, and weather variations automatically
  • Sixty-step capacity modulation prevents the temperature overshoot that triggers client complaints
  • Weather-integrated forecasting adjusts capacity before demand peaks arrive
  • Up to 40% energy reduction against conventional fixed-speed systems
  • Eliminates the most common post-commissioning callback: occupant comfort adjustments
HyperLink Extended Communication – 2,000m Piping for Campus and Tower Configurations
High-rise and campus installations often require longer refrigerant piping runs than standard systems support. The V8 Master's HyperLink communication architecture maintains signal integrity across piping distances up to 2,000 meters through proprietary waveform restoration technology. This enables centralized outdoor unit placement on rooftops or ground-level mechanical yards, regardless of how indoor units are distributed throughout the building.
  • Up to 2,000 meters of refrigerant piping eliminates the need for distributed outdoor unit placement
  • Any-topology communication supports complex vertical and horizontal distribution layouts
  • Centralized outdoor placement simplifies maintenance access and spare parts logistics
  • 110 meters maximum elevation difference accommodates the tallest commercial buildings
  • Waveform restoration maintains data integrity across maximum distances without signal degradation
  • Automatic address configuration streamlines commissioning of large multi-unit systems
EVI Heating to -30°C – Year-Round Coverage From One Platform
For contractors serving markets with genuine winter heating requirements, the V8 Master's EVI enhanced vapor injection technology extends reliable heat pump operation down to -30°C outdoor temperature. This eliminates the need to specify and install separate heating equipment—boilers, electric resistance heaters, or gas furnaces—from the same building where the VRF provides cooling. One outdoor unit, one refrigerant circuit, one service contract.
  • Rated heating capacity maintained down to -30°C without supplemental heating equipment
  • Eliminates boiler or electric heater specification from projects in cold-winter markets
  • Single-platform year-round climate management simplifies design, installation, and maintenance
  • Compressor protection algorithms ensure reliable operation without cold-weather damage
  • Stable heating capacity prevents the temperature fluctuation callbacks during cold snaps
  • Positions the contractor as a single-source climate solution provider rather than a cooling-only vendor
Technical Specifications
ParameterSpecification
SeriesV8 Master
PositioningHigh-Rise Specialist VRF
Capacity Range8-80HP
Cooling Capacity5,000-26,000W
Airflow12,600-66,000 m³/h
External Static Pressure250Pa—highest in class
Climate RatingT3—52°C high ambient cooling
EVI HeatingDown to -30°C outdoor temperature
ProtectionShieldBox IP55 + Gold Fin anti-corrosion
MonitoringSuperSense precision diagnostic sensor array
Energy SavingUp to 40% vs. conventional fixed-speed
RefrigerantR410A
Max. Piping Length2,000m (HyperLink)
Max. Height Difference110m
Control SystemMETA 2.0 with 60-step precision modulation
Power Supply180-440V, dual frequency 50/60Hz, generator compatible
BMS ProtocolsModbus RTU, BACnet
Indoor Units10 types compatible
Warranty5 years
OriginChina
Applications
  • High-rise office towers where 250Pa static pressure eliminates booster fan requirements
  • Hotel towers with rooftop outdoor units serving guest floors from 30+ stories below
  • Hospital buildings requiring reliable climate delivery across multiple vertical zones
  • University campus buildings with centralized outdoor placement and extended piping runs
  • Telecommunications facilities in extreme environments requiring year-round cooling and winter heating
  • Government buildings in cold climates where EVI heating eliminates separate boiler systems
Certifications & Standards
  • CE—European conformity marking for safety and performance
  • SASO—Saudi Arabian Standards Organization certification
  • ESMA—Emirates Standards and Metrology Authority certification
  • GCC—Gulf Cooperation Council standardization certification
  • Eurovent—European HVAC performance certification program
  • TUV SUD—Third-party product safety and quality certification
  • ISO 9001/14001/45001—Quality, environmental, and occupational health management systems
V8 Master HighRise VRF outdoor unit installation on rooftop
V8 Master HighRise VRF unit close-up showing construction details
V8 Master HighRise VRF system schematic and technical diagram