logo
Henan Hongtai HVAC Equipment Co., Ltd.
Products
Products
Home > Products > DC Inverter VRF > Heat Recovery VRF 8-80HP COP 6.0 Simultaneous Heat and Cool Every Kilowatt Works Twice Turn Waste Heat Into Your Strongest Upsell Proposition

Heat Recovery VRF 8-80HP COP 6.0 Simultaneous Heat and Cool Every Kilowatt Works Twice Turn Waste Heat Into Your Strongest Upsell Proposition

Product Details

Place of Origin: China

Brand Name: OEM;MIDEA

Certification: CB,ISO

Payment & Shipping Terms

Get Best Price
Highlight:

Heat Recovery VRF system

,

DC Inverter VRF with COP 6.0

,

Simultaneous Heat and Cool VRF

Product Name:
V8 Eco
Cooling Capacity:
5,300-60,000W
Capacity Range:
8-80HP
Positioning:
Heat Recovery Revenue Platform
System Type:
Heat Recovery VRF — Simultaneous Heating And Cooling
Refrigerant:
R32 (GWP 675), F-Gas Compliant
SEER:
38
IEER:
9.0
Product Name:
V8 Eco
Cooling Capacity:
5,300-60,000W
Capacity Range:
8-80HP
Positioning:
Heat Recovery Revenue Platform
System Type:
Heat Recovery VRF — Simultaneous Heating And Cooling
Refrigerant:
R32 (GWP 675), F-Gas Compliant
SEER:
38
IEER:
9.0
Heat Recovery VRF 8-80HP COP 6.0 Simultaneous Heat and Cool Every Kilowatt Works Twice Turn Waste Heat Into Your Strongest Upsell Proposition
Heat Recovery VRF System: 8-80HP with COP 6.0
Simultaneous heating and cooling capability that turns waste heat into your strongest upsell proposition. Every kilowatt works twice with this advanced thermal redistribution technology.
Product Overview
The V8 Eco redefines VRF systems as thermal redistribution networks that capture waste heat from cooling zones and redirect it to heating zones. This simultaneous operation achieves a combined COP of 6.0, meaning every kilowatt of electrical input produces six kilowatts of useful thermal output across both functions.
This capability creates significant revenue opportunities for contractors in applications like hotels with simultaneous guest room cooling and spa heating, hospitals with IT room cooling and patient ward heating, and mixed-use buildings with overlapping retail cooling and residential heating demands.
Key Features
COP 6.0 Heat Recovery Technology
Integrated heat recovery circuit captures surplus thermal energy during cooling and redirects it to heating zones through intelligent two-pipe architecture.
  • Six kilowatts of useful heat per kilowatt of electrical input
  • Integrated two-pipe system eliminates complex three-pipe installation
  • Intelligent valve sequencing manages simultaneous operations
  • 40-60% energy reduction versus separate systems
  • R32 refrigerant (GWP 675) meets F-Gas requirements
Green Certification Ready
Performance data pre-mapped to LEED, BREEAM, and DGNB certification requirements, eliminating custom documentation work.
  • LEED Energy and Atmosphere prerequisites addressed
  • BREEAM Energy and Health category requirements validated
  • DGNB ecological and technical criteria satisfied
  • Certification-ready solution at bid stage
Exceptional Efficiency Ratings
SEER 38 for whole-season cooling efficiency and IEER 9.0 for weighted part-load performance.
  • SEER 38 for seasonal weighted efficiency
  • IEER 9.0 for part-load performance
  • Optimal performance in 40-70% load band
  • DC inverter compressor for stepless modulation
DC Inverter Continuous Modulation
Stepless variable-speed control eliminates temperature fluctuation and cycling losses for superior comfort.
  • Eliminates cycling losses and temperature overshoot
  • Tighter temperature bands for steadier comfort
  • Reduced mechanical stress extends service life
  • Up to 40% energy savings versus fixed-speed equipment
Gold Fin Coastal Durability
Hydrophilic coating provides salt spray resistance and enhanced condensate drainage for coastal installations.
  • Salt spray resistance for coastal environments
  • Enhanced condensate drainage prevents water bridging
  • Maintains heat transfer efficiency beyond warranty
  • Reduces maintenance frequency and cleaning requirements
Advanced BMS Integration
Full compatibility with standard VRF control infrastructure and native building management system protocols.
  • Independent temperature setpoints for each indoor unit
  • Multi-zone independent scheduling
  • Native Modbus RTU and BACnet connectivity
  • Remote monitoring capability
  • Compatible with 10 indoor unit types
Technical Specifications
Parameter Specification
Series V8 Eco
Capacity Range 8-80HP
Cooling Capacity 5,300-60,000W
System Type Heat recovery VRF - simultaneous heating and cooling
Heat Recovery COP 6.0
SEER 38
IEER 9.0
Compressor DC inverter, stepless variable-speed
Refrigerant R32 (GWP 675), F-Gas compliant
Max. Piping Length 1,000m
Max. Height Difference 70m
Coil Protection Gold Fin anti-corrosion
BMS Protocols Modbus RTU, BACnet
Warranty 5 years
Applications
  • Hotels with simultaneous guest room cooling and spa/heating demands
  • Hospitals requiring concurrent IT room cooling and patient ward heating
  • Mixed-use developments with overlapping retail cooling and residential heating
  • Office buildings pursuing LEED or BREEAM certification
  • University campus buildings with diverse thermal demands
  • Retrofit projects replacing separate heating and cooling systems
Certifications & Standards
CE
Eurovent
ERP
EU Energy Label
F-Gas
TUV SUD
ISO 9001/14001/45001
Product Gallery