logo
Products
PRODUCTS DETAILS
Home > Products >
Midea One way Cassette Fan Coil Unit 153mm Slim One Way Cassette FCU Built for Fast Corridor Installs DC One Way Cassette FCU with 7 Speed Control Saves 30 Energy

Midea One way Cassette Fan Coil Unit 153mm Slim One Way Cassette FCU Built for Fast Corridor Installs DC One Way Cassette FCU with 7 Speed Control Saves 30 Energy

Detail Information
Place of Origin
China
Brand Name
OEM;MIDEA
Certification
CB,ISO
Product Name:
One Way Cassette Fan Coil Unit
Airflow Range:
300–400 CFM 300–600 CFM
Cooling Capacity:
3.04–3.79 KW 2.65–5.20 KW
Heating Capacity:
5.13–6.41 KW 3.15–5.75 KW
Power Input:
32–40 W 14–38 W
Sound Pressure Level (H):
36–37 DB(A) 33.5–44.6 DB(A)
Power Supply:
220–240V / 1Ph / 50Hz
Motor Type:
Low-noise 3-speed AC DC Brushless
Highlight:

slim one way cassette FCU

,

DC one way cassette FCU

,

7 speed cassette fan coil unit

Product Description
Product Overview

Corridor and perimeter packages are won on speed: the faster each unit goes in, the more floors your crew closes out per week. The Midea One-way Cassette Fan Coil Unit is built for exactly this kind of work. A 153mm chassis slides into the narrow ceiling voids above corridors, lobbies and room entryways where standard cassettes simply do not fit, and the single-direction discharge throws conditioned air along the hallway instead of fighting the walls. With cooling capacities from 2.65 to 5.20 kW across the combined AC and DC range, one product family covers hotel corridors, office hallways, apartment foyers and retail perimeters without juggling multiple suppliers.

The built-in 750mm condensate pump is the detail your installers will thank you for. No slope calculations, no hunting for falls across long corridor runs, no call-backs for water stains on fresh ceiling tiles. Hang the unit, connect two pipes and one drain, wire it to a standard 220-240V / 1Ph / 50Hz circuit, and move on to the next one. Both motor tiers share the same body dimensions and G1/2" pipe connections, so crews swap between AC and DC models on the same floor plan without relearning anything.

Choose the DC version — a DC inverter brushless motor with seven fan speeds via the KJR-75A wired controller — and you hand the building owner a unit that draws as little as 14W, cuts fan energy by up to 30% and runs 2-5 dB(A) quieter than the AC equivalent: an easy upsell that differentiates your bid at near-zero extra labour. Power-off memory restores settings after outages, the washable filter pulls out from below in seconds, and Hongtai backs every project with OEM/ODM support — custom voltages from 180-440V at 50/60Hz, project branding, Modbus RTU and BACnet protocols — plus dependable spare-parts supply long after handover.

Key Selling Points
  • 153mm Ultra-Slim Body — Fits narrow corridor ceiling voids where standard cassettes cannot go; no structural modifications or ceiling redesign required.
  • Built-In 750mm Drain Pump — Eliminates condensate slope work on long corridor runs; removes the most common source of water-damage call-backs.
  • Fast One-Crew Install — Compact chassis, two-pipe connection and standard single-phase supply keep labour hours per unit low and daily install counts high.
  • AC/DC Bid Flexibility — Quote AC for price-driven tenders or DC inverter models for efficiency-focused specifications, from one supplier on one purchase order.
  • Seven-Speed DC Control (KJR-75A) — Fine-tune airflow at commissioning to match each corridor; fewer comfort complaints after handover.
  • Power-Off Memory — Units resume previous settings automatically after outages; no midnight calls from facility staff.
  • Washable Filter, Bottom Access — Routine service takes minutes without removing panels or ceiling tiles.
  • OEM/ODM Project Support via Hongtai — Custom voltage (180-440V, 50/60Hz), branding and BMS protocols for project-specific tenders and export contracts.
Applications
  1. Hotel Corridor Packages — Slim bodies run the full length of guestroom corridors; quiet DC models protect guest sleep quality and brand standards.
  2. Office Hallways and Lift Lobbies — Directional airflow conditions circulation zones efficiently without oversized capacity.
  3. Apartment Entry Halls — Compact profile preserves ceiling height in residential corridors, foyers and lift approaches.
  4. Retail Perimeter Zones — Single-direction discharge sweeps along shopfronts and display glazing without dead spots.
  5. Hospital Ward Corridors — Low-noise DC operation and tool-free filter service suit healthcare maintenance regimes.
Certifications & Standards
  • CE Marking — European conformity for safety and electromagnetic compatibility.
  • Eurovent Certified Performance — Third-party verified capacity and efficiency ratings.
  • ERP Compliant — Meets EU Energy-related Products Directive requirements.
  • RoHS Compliant — Restriction of Hazardous Substances directive conformance.
  • GB/T 19232 — Chinese national standard for fan coil unit performance testing.
Technical Specifications
Parameter AC Series DC Series
Airflow Range300-400 CFM300-600 CFM
Cooling Capacity3.04-3.79 kW2.65-5.20 kW
Heating Capacity5.13-6.41 kW3.15-5.75 kW
Power Input32-40 W14-38 W
Sound Pressure Level (H)36-37 dB(A)33.5-44.6 dB(A)
Power Supply220-240V / 1Ph / 50Hz220-240V / 1Ph / 50Hz
Drain Pump Head750 mm750 mm
Body Height153 mm153 mm
Coil Rows22
Max. Working Pressure1.6 MPa1.6 MPa
Motor TypeLow-noise 3-speed ACDC Brushless
Pipe ConnectionG1/2"G1/2"
Product Gallery
Products
PRODUCTS DETAILS
Midea One way Cassette Fan Coil Unit 153mm Slim One Way Cassette FCU Built for Fast Corridor Installs DC One Way Cassette FCU with 7 Speed Control Saves 30 Energy
Detail Information
Place of Origin
China
Brand Name
OEM;MIDEA
Certification
CB,ISO
Product Name:
One Way Cassette Fan Coil Unit
Airflow Range:
300–400 CFM 300–600 CFM
Cooling Capacity:
3.04–3.79 KW 2.65–5.20 KW
Heating Capacity:
5.13–6.41 KW 3.15–5.75 KW
Power Input:
32–40 W 14–38 W
Sound Pressure Level (H):
36–37 DB(A) 33.5–44.6 DB(A)
Power Supply:
220–240V / 1Ph / 50Hz
Motor Type:
Low-noise 3-speed AC DC Brushless
Highlight

slim one way cassette FCU

,

DC one way cassette FCU

,

7 speed cassette fan coil unit

Product Description
Product Overview

Corridor and perimeter packages are won on speed: the faster each unit goes in, the more floors your crew closes out per week. The Midea One-way Cassette Fan Coil Unit is built for exactly this kind of work. A 153mm chassis slides into the narrow ceiling voids above corridors, lobbies and room entryways where standard cassettes simply do not fit, and the single-direction discharge throws conditioned air along the hallway instead of fighting the walls. With cooling capacities from 2.65 to 5.20 kW across the combined AC and DC range, one product family covers hotel corridors, office hallways, apartment foyers and retail perimeters without juggling multiple suppliers.

The built-in 750mm condensate pump is the detail your installers will thank you for. No slope calculations, no hunting for falls across long corridor runs, no call-backs for water stains on fresh ceiling tiles. Hang the unit, connect two pipes and one drain, wire it to a standard 220-240V / 1Ph / 50Hz circuit, and move on to the next one. Both motor tiers share the same body dimensions and G1/2" pipe connections, so crews swap between AC and DC models on the same floor plan without relearning anything.

Choose the DC version — a DC inverter brushless motor with seven fan speeds via the KJR-75A wired controller — and you hand the building owner a unit that draws as little as 14W, cuts fan energy by up to 30% and runs 2-5 dB(A) quieter than the AC equivalent: an easy upsell that differentiates your bid at near-zero extra labour. Power-off memory restores settings after outages, the washable filter pulls out from below in seconds, and Hongtai backs every project with OEM/ODM support — custom voltages from 180-440V at 50/60Hz, project branding, Modbus RTU and BACnet protocols — plus dependable spare-parts supply long after handover.

Key Selling Points
  • 153mm Ultra-Slim Body — Fits narrow corridor ceiling voids where standard cassettes cannot go; no structural modifications or ceiling redesign required.
  • Built-In 750mm Drain Pump — Eliminates condensate slope work on long corridor runs; removes the most common source of water-damage call-backs.
  • Fast One-Crew Install — Compact chassis, two-pipe connection and standard single-phase supply keep labour hours per unit low and daily install counts high.
  • AC/DC Bid Flexibility — Quote AC for price-driven tenders or DC inverter models for efficiency-focused specifications, from one supplier on one purchase order.
  • Seven-Speed DC Control (KJR-75A) — Fine-tune airflow at commissioning to match each corridor; fewer comfort complaints after handover.
  • Power-Off Memory — Units resume previous settings automatically after outages; no midnight calls from facility staff.
  • Washable Filter, Bottom Access — Routine service takes minutes without removing panels or ceiling tiles.
  • OEM/ODM Project Support via Hongtai — Custom voltage (180-440V, 50/60Hz), branding and BMS protocols for project-specific tenders and export contracts.
Applications
  1. Hotel Corridor Packages — Slim bodies run the full length of guestroom corridors; quiet DC models protect guest sleep quality and brand standards.
  2. Office Hallways and Lift Lobbies — Directional airflow conditions circulation zones efficiently without oversized capacity.
  3. Apartment Entry Halls — Compact profile preserves ceiling height in residential corridors, foyers and lift approaches.
  4. Retail Perimeter Zones — Single-direction discharge sweeps along shopfronts and display glazing without dead spots.
  5. Hospital Ward Corridors — Low-noise DC operation and tool-free filter service suit healthcare maintenance regimes.
Certifications & Standards
  • CE Marking — European conformity for safety and electromagnetic compatibility.
  • Eurovent Certified Performance — Third-party verified capacity and efficiency ratings.
  • ERP Compliant — Meets EU Energy-related Products Directive requirements.
  • RoHS Compliant — Restriction of Hazardous Substances directive conformance.
  • GB/T 19232 — Chinese national standard for fan coil unit performance testing.
Technical Specifications
Parameter AC Series DC Series
Airflow Range300-400 CFM300-600 CFM
Cooling Capacity3.04-3.79 kW2.65-5.20 kW
Heating Capacity5.13-6.41 kW3.15-5.75 kW
Power Input32-40 W14-38 W
Sound Pressure Level (H)36-37 dB(A)33.5-44.6 dB(A)
Power Supply220-240V / 1Ph / 50Hz220-240V / 1Ph / 50Hz
Drain Pump Head750 mm750 mm
Body Height153 mm153 mm
Coil Rows22
Max. Working Pressure1.6 MPa1.6 MPa
Motor TypeLow-noise 3-speed ACDC Brushless
Pipe ConnectionG1/2"G1/2"
Product Gallery
Sitemap |  Privacy Policy | China Good Quality DC Inverter VRF Supplier. Copyright © 2024-2026 Henan Hongtai HVAC Equipment Co., Ltd. . All Rights Reserved.
+86 18703827920