logo
Products
PRODUCTS DETAILS
Home > Products >
Midea One way Cassette Fan Coil Unit Built In 750mm Pump Cuts One Way Cassette Install Time on Site 153mm Slim One Way Cassette FCU Built for Fast Corridor Installs

Midea One way Cassette Fan Coil Unit Built In 750mm Pump Cuts One Way Cassette Install Time on Site 153mm Slim One Way Cassette FCU Built for Fast Corridor Installs

Detail Information
Place of Origin
China
Brand Name
OEM;MIDEA
Certification
CB,ISO
Product Name:
One Way Cassette Fan Coil Unit
Airflow Range:
300–400 CFM 300–600 CFM
Cooling Capacity:
3.04–3.79 KW 2.65–5.20 KW
Heating Capacity:
5.13–6.41 KW 3.15–5.75 KW
Power Input:
32–40 W 14–38 W
Sound Pressure Level (H):
36–37 DB(A) 33.5–44.6 DB(A)
Power Supply:
220–240V / 1Ph / 50Hz
Motor Type:
Low-noise 3-speed AC DC Brushless
Highlight:

one way cassette fan coil unit

,

slim 153mm cassette FCU

,

built-in 750mm pump cassette FCU

Product Description
Product Overview: Slim One-Way Cassette FCU for Fast Corridor Installs

Corridor and perimeter packages are won on speed: the faster each unit goes in, the more floors your crew closes out per week. The Midea One-way Cassette Fan Coil Unit is built for exactly this kind of work. A 153mm chassis slides into the narrow ceiling voids above corridors, lobbies and room entryways where standard cassettes simply do not fit, and the single-direction discharge throws conditioned air along the hallway instead of fighting the walls. With cooling capacities from 2.65 to 5.20 kW across the combined AC and DC range, one product family covers hotel corridors, office hallways, apartment foyers and retail perimeters without juggling multiple suppliers.

The built-in 750mm condensate pump is the detail your installers will thank you for. No slope calculations, no hunting for falls across long corridor runs, no call-backs for water stains on fresh ceiling tiles. Hang the unit, connect two pipes and one drain, wire it to a standard 220-240V / 1Ph / 50Hz circuit, and move on to the next one. Both motor tiers share the same body dimensions and G1/2" pipe connections, so crews swap between AC and DC models on the same floor plan without relearning anything.

Choose the DC version — a DC inverter brushless motor with seven fan speeds via the KJR-75A wired controller — and you hand the building owner a unit that draws as little as 14W, cuts fan energy by up to 30% and runs 2-5 dB(A) quieter than the AC equivalent: an easy upsell that differentiates your bid at near-zero extra labour. Power-off memory restores settings after outages, the washable filter pulls out from below in seconds, and Hongtai backs every project with OEM/ODM support — custom voltages from 180-440V at 50/60Hz, project branding, Modbus RTU and BACnet protocols — plus dependable spare-parts supply long after handover.

Key Selling Points
  • 153mm Ultra-Slim Body — Fits narrow corridor ceiling voids where standard cassettes cannot go; no structural modifications or ceiling redesign required.
  • Built-In 750mm Drain Pump — Eliminates condensate slope work on long corridor runs; removes the most common source of water-damage call-backs.
  • Fast One-Crew Install — Compact chassis, two-pipe connection and standard single-phase supply keep labour hours per unit low and daily install counts high.
  • AC/DC Bid Flexibility — Quote AC for price-driven tenders or DC inverter models for efficiency-focused specifications, from one supplier on one purchase order.
  • Seven-Speed DC Control (KJR-75A) — Fine-tune airflow at commissioning to match each corridor; fewer comfort complaints after handover.
  • Power-Off Memory — Units resume previous settings automatically after outages; no midnight calls from facility staff.
  • Washable Filter, Bottom Access — Routine service takes minutes without removing panels or ceiling tiles.
  • OEM/ODM Project Support via Hongtai — Custom voltage (180-440V, 50/60Hz), branding and BMS protocols for project-specific tenders and export contracts.
AC vs DC — Which Should You Specify?

For price-driven tenders with simple 3-speed control, the AC version keeps unit cost low and spares universal across the job. For hotel corridors and residential work where noise and running cost shape reviews, the DC inverter brushless version earns its modest premium: seven speeds for precise balancing at commissioning, up to 30% lower fan energy, and 2-5 dB(A) quieter operation. Both share the same 153mm body, 750mm pump and G1/2" connections — so the motor decision never changes your installation method.

Applications
  1. Hotel Corridor Packages — Slim bodies run the full length of guestroom corridors; quiet DC models protect guest sleep quality and brand standards.
  2. Office Hallways and Lift Lobbies — Directional airflow conditions circulation zones efficiently without oversized capacity.
  3. Apartment Entry Halls — Compact profile preserves ceiling height in residential corridors, foyers and lift approaches.
  4. Retail Perimeter Zones — Single-direction discharge sweeps along shopfronts and display glazing without dead spots.
  5. Hospital Ward Corridors — Low-noise DC operation and tool-free filter service suit healthcare maintenance regimes.
Frequently Asked Questions
Q: What ceiling void depth does a one-way cassette fan coil unit need?

A: The 153mm body is among the slimmest in its class and fits the narrow voids above corridors and entryways where standard cassettes cannot go. Allow the hanger and service clearances shown in the installation manual; no structural modification is normally required.

Q: Does this unit need a separate condensate pump?

A: No. A 750mm-lift drain pump is built in as standard, so condensate lifts up and out without gravity slope work — one less component to buy, fit and maintain.

Q: What areas can a 300-600 CFM one-way cassette cover?

A: Final sizing always follows a heat-load calculation, but this airflow band typically serves corridors, lift lobbies, entry foyers and retail perimeter strips. The DC range extends to 600 CFM and 5.20 kW for longer runs.

Q: What power supply does it require?

A: Standard supply is 220-240V / 1Ph / 50Hz. For export projects on other grids, Hongtai supports OEM/ODM custom voltages from 180-440V at 50/60Hz.

Q: How is the unit serviced after installation?

A: The washable filter pulls out from below without removing ceiling tiles, and power-off memory restores settings after outages — so routine service is a minutes-long visit, not a ceiling-opening event.

Certifications & Standards
  • CE Marking — European conformity for safety and electromagnetic compatibility.
  • Eurovent Certified Performance — Third-party verified capacity and efficiency ratings.
  • ERP Compliant — Meets EU Energy-related Products Directive requirements.
  • RoHS Compliant — Restriction of Hazardous Substances directive conformance.
  • GB/T 19232 — Chinese national standard for fan coil unit performance testing.
Technical Specifications
Parameter AC Series DC Series
Airflow Range300-400 CFM300-600 CFM
Cooling Capacity3.04-3.79 kW2.65-5.20 kW
Heating Capacity5.13-6.41 kW3.15-5.75 kW
Power Input32-40 W14-38 W
Sound Pressure Level (H)36-37 dB(A)33.5-44.6 dB(A)
Power Supply220-240V / 1Ph / 50Hz220-240V / 1Ph / 50Hz
Drain Pump Head750 mm750 mm
Body Height153 mm153 mm
Coil Rows22
Max. Working Pressure1.6 MPa1.6 MPa
Motor TypeLow-noise 3-speed ACDC Brushless
Pipe ConnectionG1/2"G1/2"
Product Gallery
Related Search Terms

one way cassette fan coil unit 153mm slim cassette FCU single direction cassette air conditioner corridor fan coil unit fan coil with built-in drain pump DC brushless cassette FCU 220V hotel corridor air conditioning unit ceiling cassette FCU price

Products
PRODUCTS DETAILS
Midea One way Cassette Fan Coil Unit Built In 750mm Pump Cuts One Way Cassette Install Time on Site 153mm Slim One Way Cassette FCU Built for Fast Corridor Installs
Detail Information
Place of Origin
China
Brand Name
OEM;MIDEA
Certification
CB,ISO
Product Name:
One Way Cassette Fan Coil Unit
Airflow Range:
300–400 CFM 300–600 CFM
Cooling Capacity:
3.04–3.79 KW 2.65–5.20 KW
Heating Capacity:
5.13–6.41 KW 3.15–5.75 KW
Power Input:
32–40 W 14–38 W
Sound Pressure Level (H):
36–37 DB(A) 33.5–44.6 DB(A)
Power Supply:
220–240V / 1Ph / 50Hz
Motor Type:
Low-noise 3-speed AC DC Brushless
Highlight

one way cassette fan coil unit

,

slim 153mm cassette FCU

,

built-in 750mm pump cassette FCU

Product Description
Product Overview: Slim One-Way Cassette FCU for Fast Corridor Installs

Corridor and perimeter packages are won on speed: the faster each unit goes in, the more floors your crew closes out per week. The Midea One-way Cassette Fan Coil Unit is built for exactly this kind of work. A 153mm chassis slides into the narrow ceiling voids above corridors, lobbies and room entryways where standard cassettes simply do not fit, and the single-direction discharge throws conditioned air along the hallway instead of fighting the walls. With cooling capacities from 2.65 to 5.20 kW across the combined AC and DC range, one product family covers hotel corridors, office hallways, apartment foyers and retail perimeters without juggling multiple suppliers.

The built-in 750mm condensate pump is the detail your installers will thank you for. No slope calculations, no hunting for falls across long corridor runs, no call-backs for water stains on fresh ceiling tiles. Hang the unit, connect two pipes and one drain, wire it to a standard 220-240V / 1Ph / 50Hz circuit, and move on to the next one. Both motor tiers share the same body dimensions and G1/2" pipe connections, so crews swap between AC and DC models on the same floor plan without relearning anything.

Choose the DC version — a DC inverter brushless motor with seven fan speeds via the KJR-75A wired controller — and you hand the building owner a unit that draws as little as 14W, cuts fan energy by up to 30% and runs 2-5 dB(A) quieter than the AC equivalent: an easy upsell that differentiates your bid at near-zero extra labour. Power-off memory restores settings after outages, the washable filter pulls out from below in seconds, and Hongtai backs every project with OEM/ODM support — custom voltages from 180-440V at 50/60Hz, project branding, Modbus RTU and BACnet protocols — plus dependable spare-parts supply long after handover.

Key Selling Points
  • 153mm Ultra-Slim Body — Fits narrow corridor ceiling voids where standard cassettes cannot go; no structural modifications or ceiling redesign required.
  • Built-In 750mm Drain Pump — Eliminates condensate slope work on long corridor runs; removes the most common source of water-damage call-backs.
  • Fast One-Crew Install — Compact chassis, two-pipe connection and standard single-phase supply keep labour hours per unit low and daily install counts high.
  • AC/DC Bid Flexibility — Quote AC for price-driven tenders or DC inverter models for efficiency-focused specifications, from one supplier on one purchase order.
  • Seven-Speed DC Control (KJR-75A) — Fine-tune airflow at commissioning to match each corridor; fewer comfort complaints after handover.
  • Power-Off Memory — Units resume previous settings automatically after outages; no midnight calls from facility staff.
  • Washable Filter, Bottom Access — Routine service takes minutes without removing panels or ceiling tiles.
  • OEM/ODM Project Support via Hongtai — Custom voltage (180-440V, 50/60Hz), branding and BMS protocols for project-specific tenders and export contracts.
AC vs DC — Which Should You Specify?

For price-driven tenders with simple 3-speed control, the AC version keeps unit cost low and spares universal across the job. For hotel corridors and residential work where noise and running cost shape reviews, the DC inverter brushless version earns its modest premium: seven speeds for precise balancing at commissioning, up to 30% lower fan energy, and 2-5 dB(A) quieter operation. Both share the same 153mm body, 750mm pump and G1/2" connections — so the motor decision never changes your installation method.

Applications
  1. Hotel Corridor Packages — Slim bodies run the full length of guestroom corridors; quiet DC models protect guest sleep quality and brand standards.
  2. Office Hallways and Lift Lobbies — Directional airflow conditions circulation zones efficiently without oversized capacity.
  3. Apartment Entry Halls — Compact profile preserves ceiling height in residential corridors, foyers and lift approaches.
  4. Retail Perimeter Zones — Single-direction discharge sweeps along shopfronts and display glazing without dead spots.
  5. Hospital Ward Corridors — Low-noise DC operation and tool-free filter service suit healthcare maintenance regimes.
Frequently Asked Questions
Q: What ceiling void depth does a one-way cassette fan coil unit need?

A: The 153mm body is among the slimmest in its class and fits the narrow voids above corridors and entryways where standard cassettes cannot go. Allow the hanger and service clearances shown in the installation manual; no structural modification is normally required.

Q: Does this unit need a separate condensate pump?

A: No. A 750mm-lift drain pump is built in as standard, so condensate lifts up and out without gravity slope work — one less component to buy, fit and maintain.

Q: What areas can a 300-600 CFM one-way cassette cover?

A: Final sizing always follows a heat-load calculation, but this airflow band typically serves corridors, lift lobbies, entry foyers and retail perimeter strips. The DC range extends to 600 CFM and 5.20 kW for longer runs.

Q: What power supply does it require?

A: Standard supply is 220-240V / 1Ph / 50Hz. For export projects on other grids, Hongtai supports OEM/ODM custom voltages from 180-440V at 50/60Hz.

Q: How is the unit serviced after installation?

A: The washable filter pulls out from below without removing ceiling tiles, and power-off memory restores settings after outages — so routine service is a minutes-long visit, not a ceiling-opening event.

Certifications & Standards
  • CE Marking — European conformity for safety and electromagnetic compatibility.
  • Eurovent Certified Performance — Third-party verified capacity and efficiency ratings.
  • ERP Compliant — Meets EU Energy-related Products Directive requirements.
  • RoHS Compliant — Restriction of Hazardous Substances directive conformance.
  • GB/T 19232 — Chinese national standard for fan coil unit performance testing.
Technical Specifications
Parameter AC Series DC Series
Airflow Range300-400 CFM300-600 CFM
Cooling Capacity3.04-3.79 kW2.65-5.20 kW
Heating Capacity5.13-6.41 kW3.15-5.75 kW
Power Input32-40 W14-38 W
Sound Pressure Level (H)36-37 dB(A)33.5-44.6 dB(A)
Power Supply220-240V / 1Ph / 50Hz220-240V / 1Ph / 50Hz
Drain Pump Head750 mm750 mm
Body Height153 mm153 mm
Coil Rows22
Max. Working Pressure1.6 MPa1.6 MPa
Motor TypeLow-noise 3-speed ACDC Brushless
Pipe ConnectionG1/2"G1/2"
Product Gallery
Related Search Terms

one way cassette fan coil unit 153mm slim cassette FCU single direction cassette air conditioner corridor fan coil unit fan coil with built-in drain pump DC brushless cassette FCU 220V hotel corridor air conditioning unit ceiling cassette FCU price

Sitemap |  Privacy Policy | China Good Quality DC Inverter VRF Supplier. Copyright © 2024-2026 Henan Hongtai HVAC Equipment Co., Ltd. . All Rights Reserved.
+86 18703827920