Corridor and perimeter packages are won on speed: the faster each unit goes in, the more floors your crew closes out per week. The Midea One-way Cassette Fan Coil Unit is built for exactly this kind of work. A 153mm chassis slides into the narrow ceiling voids above corridors, lobbies and room entryways where standard cassettes simply do not fit, and the single-direction discharge throws conditioned air along the hallway instead of fighting the walls. With cooling capacities from 2.65 to 5.20 kW across the combined AC and DC range, one product family covers hotel corridors, office hallways, apartment foyers and retail perimeters without juggling multiple suppliers.
The built-in 750mm condensate pump is the detail your installers will thank you for. No slope calculations, no hunting for falls across long corridor runs, no call-backs for water stains on fresh ceiling tiles. Hang the unit, connect two pipes and one drain, wire it to a standard 220-240V / 1Ph / 50Hz circuit, and move on to the next one. Both motor tiers share the same body dimensions and G1/2" pipe connections, so crews swap between AC and DC models on the same floor plan without relearning anything.
Choose the DC version — a DC inverter brushless motor with seven fan speeds via the KJR-75A wired controller — and you hand the building owner a unit that draws as little as 14W, cuts fan energy by up to 30% and runs 2-5 dB(A) quieter than the AC equivalent: an easy upsell that differentiates your bid at near-zero extra labour. Power-off memory restores settings after outages, the washable filter pulls out from below in seconds, and Hongtai backs every project with OEM/ODM support — custom voltages from 180-440V at 50/60Hz, project branding, Modbus RTU and BACnet protocols — plus dependable spare-parts supply long after handover.
For price-driven tenders with simple 3-speed control, the AC version keeps unit cost low and spares universal across the job. For hotel corridors and residential work where noise and running cost shape reviews, the DC inverter brushless version earns its modest premium: seven speeds for precise balancing at commissioning, up to 30% lower fan energy, and 2-5 dB(A) quieter operation. Both share the same 153mm body, 750mm pump and G1/2" connections — so the motor decision never changes your installation method.
A: The 153mm body is among the slimmest in its class and fits the narrow voids above corridors and entryways where standard cassettes cannot go. Allow the hanger and service clearances shown in the installation manual; no structural modification is normally required.
A: No. A 750mm-lift drain pump is built in as standard, so condensate lifts up and out without gravity slope work — one less component to buy, fit and maintain.
A: Final sizing always follows a heat-load calculation, but this airflow band typically serves corridors, lift lobbies, entry foyers and retail perimeter strips. The DC range extends to 600 CFM and 5.20 kW for longer runs.
A: Standard supply is 220-240V / 1Ph / 50Hz. For export projects on other grids, Hongtai supports OEM/ODM custom voltages from 180-440V at 50/60Hz.
A: The washable filter pulls out from below without removing ceiling tiles, and power-off memory restores settings after outages — so routine service is a minutes-long visit, not a ceiling-opening event.
| Parameter | AC Series | DC Series |
|---|---|---|
| Airflow Range | 300-400 CFM | 300-600 CFM |
| Cooling Capacity | 3.04-3.79 kW | 2.65-5.20 kW |
| Heating Capacity | 5.13-6.41 kW | 3.15-5.75 kW |
| Power Input | 32-40 W | 14-38 W |
| Sound Pressure Level (H) | 36-37 dB(A) | 33.5-44.6 dB(A) |
| Power Supply | 220-240V / 1Ph / 50Hz | 220-240V / 1Ph / 50Hz |
| Drain Pump Head | 750 mm | 750 mm |
| Body Height | 153 mm | 153 mm |
| Coil Rows | 2 | 2 |
| Max. Working Pressure | 1.6 MPa | 1.6 MPa |
| Motor Type | Low-noise 3-speed AC | DC Brushless |
| Pipe Connection | G1/2" | G1/2" |
one way cassette fan coil unit 153mm slim cassette FCU single direction cassette air conditioner corridor fan coil unit fan coil with built-in drain pump DC brushless cassette FCU 220V hotel corridor air conditioning unit ceiling cassette FCU price
Corridor and perimeter packages are won on speed: the faster each unit goes in, the more floors your crew closes out per week. The Midea One-way Cassette Fan Coil Unit is built for exactly this kind of work. A 153mm chassis slides into the narrow ceiling voids above corridors, lobbies and room entryways where standard cassettes simply do not fit, and the single-direction discharge throws conditioned air along the hallway instead of fighting the walls. With cooling capacities from 2.65 to 5.20 kW across the combined AC and DC range, one product family covers hotel corridors, office hallways, apartment foyers and retail perimeters without juggling multiple suppliers.
The built-in 750mm condensate pump is the detail your installers will thank you for. No slope calculations, no hunting for falls across long corridor runs, no call-backs for water stains on fresh ceiling tiles. Hang the unit, connect two pipes and one drain, wire it to a standard 220-240V / 1Ph / 50Hz circuit, and move on to the next one. Both motor tiers share the same body dimensions and G1/2" pipe connections, so crews swap between AC and DC models on the same floor plan without relearning anything.
Choose the DC version — a DC inverter brushless motor with seven fan speeds via the KJR-75A wired controller — and you hand the building owner a unit that draws as little as 14W, cuts fan energy by up to 30% and runs 2-5 dB(A) quieter than the AC equivalent: an easy upsell that differentiates your bid at near-zero extra labour. Power-off memory restores settings after outages, the washable filter pulls out from below in seconds, and Hongtai backs every project with OEM/ODM support — custom voltages from 180-440V at 50/60Hz, project branding, Modbus RTU and BACnet protocols — plus dependable spare-parts supply long after handover.
For price-driven tenders with simple 3-speed control, the AC version keeps unit cost low and spares universal across the job. For hotel corridors and residential work where noise and running cost shape reviews, the DC inverter brushless version earns its modest premium: seven speeds for precise balancing at commissioning, up to 30% lower fan energy, and 2-5 dB(A) quieter operation. Both share the same 153mm body, 750mm pump and G1/2" connections — so the motor decision never changes your installation method.
A: The 153mm body is among the slimmest in its class and fits the narrow voids above corridors and entryways where standard cassettes cannot go. Allow the hanger and service clearances shown in the installation manual; no structural modification is normally required.
A: No. A 750mm-lift drain pump is built in as standard, so condensate lifts up and out without gravity slope work — one less component to buy, fit and maintain.
A: Final sizing always follows a heat-load calculation, but this airflow band typically serves corridors, lift lobbies, entry foyers and retail perimeter strips. The DC range extends to 600 CFM and 5.20 kW for longer runs.
A: Standard supply is 220-240V / 1Ph / 50Hz. For export projects on other grids, Hongtai supports OEM/ODM custom voltages from 180-440V at 50/60Hz.
A: The washable filter pulls out from below without removing ceiling tiles, and power-off memory restores settings after outages — so routine service is a minutes-long visit, not a ceiling-opening event.
| Parameter | AC Series | DC Series |
|---|---|---|
| Airflow Range | 300-400 CFM | 300-600 CFM |
| Cooling Capacity | 3.04-3.79 kW | 2.65-5.20 kW |
| Heating Capacity | 5.13-6.41 kW | 3.15-5.75 kW |
| Power Input | 32-40 W | 14-38 W |
| Sound Pressure Level (H) | 36-37 dB(A) | 33.5-44.6 dB(A) |
| Power Supply | 220-240V / 1Ph / 50Hz | 220-240V / 1Ph / 50Hz |
| Drain Pump Head | 750 mm | 750 mm |
| Body Height | 153 mm | 153 mm |
| Coil Rows | 2 | 2 |
| Max. Working Pressure | 1.6 MPa | 1.6 MPa |
| Motor Type | Low-noise 3-speed AC | DC Brushless |
| Pipe Connection | G1/2" | G1/2" |
one way cassette fan coil unit 153mm slim cassette FCU single direction cassette air conditioner corridor fan coil unit fan coil with built-in drain pump DC brushless cassette FCU 220V hotel corridor air conditioning unit ceiling cassette FCU price