logo
Products
PRODUCTS DETAILS
Home > Products >
Midea Four way Cassette Fan Coil Unit Platform One Chassis Three Panel Options 750mm Drain Pump

Midea Four way Cassette Fan Coil Unit Platform One Chassis Three Panel Options 750mm Drain Pump

Detail Information
Place of Origin
China
Brand Name
OEM;MIDEA
Certification
CB,ISO
Product Name:
Four Way Cassette Fan Coil Unit
Airflow Range:
400–800 CFM 400–1050 CFM
Cooling Capacity:
5.7–12.9 KW 6.12–11.19 KW
Heating Capacity:
9.66–17.6 KW 6.06–14.92 KW
Power Input:
84–190 W 20–137 W
Sound Pressure Level (H):
45–50 DB(A) 39–49 DB(A)
Power Supply:
220–240V / 1Ph / 50Hz
Motor Type:
Low-noise 3-speed AC DC Brushless
Highlight:

Midea four way cassette FCU

,

750mm drain pump fan coil

,

three panel options FCU

Product Description
Product Overview: Midea Four-Way Cassette Fan Coil Unit

Every contractor has a bread-and-butter cassette job — open-plan offices, retail floors, restaurants — where the same unit repeats across the ceiling grid bay after bay. The Midea Four-way Cassette Fan Coil Unit turns that repetition into profit: one chassis architecture spanning 400–1050 CFM across the AC and DC range, with cooling capacities from 5.7 to 12.9 kW, lets your crew standardise hangers, pipe connections and panel cut-outs across the entire floor. Order the chassis early and hit a rhythm — every unit after the first goes in faster.

Panels are the classic late-change killer on cassette jobs: the architect switches from four-way to 360° after rough-in, and suddenly you are re-ordering equipment. Not here. Classic four-outlet, 360° and NEW 360° panels all mount on the same chassis, so a design change costs a panel swap, not a return trip. Individual vane adjustment lets you balance airflow zone by zone at commissioning; two-pipe and four-pipe factory versions match whatever the building risers actually deliver; and the 750mm drain pump (1200mm on 3rd Generation DC) handles shallow and deep voids alike without condensate slope work.

For efficiency-driven tenders, the DC inverter brushless range cuts fan energy by up to 30% and noise by 2–5 dB(A), while 3rd Generation models add occupancy sensing for automatic setback in empty rooms, 4.5m ceiling capability for lobbies and atria, and native V8 integration for jobs pairing FCUs with Midea VRF outdoor systems. XYE and PQE ports plus GW-MOD(A) and GW-BAC(D) gateways make central control and Modbus/BACnet handover straightforward for the controls contractor. All models run on 220–240V / 1Ph / 50Hz, with OEM/ODM custom voltage, branding and protocol options available through Hongtai for export projects.

Key Selling Points
  • One Chassis, Three Panel Options — Classic 4-way, 360° and NEW 360° panels share one chassis; late design changes cost a panel swap, not a re-order.
  • Standardised Repeat Installs — Same hangers, pipe sizes and cut-outs across the floor; crews hit a rhythm and labour hours per unit drop.
  • Individual Vane Adjustment — Balance airflow zone by zone at commissioning without relocating units.
  • 750mm / 1200mm Drain Pump Range — Handles shallow and deep ceiling voids without condensate slope calculations.
  • 2-Pipe and 4-Pipe Factory Versions — Match building hydraulics exactly; no site adaptation or buffer vessels required.
  • Occupancy Sensing (3rd Gen DC) — Automatic setback in vacant zones; an easy energy-saving upsell for the building owner.
  • XYE / PQE Ports with Modbus & BACnet Gateways — Clean central-control and BMS handover without third-party interface hardware.
  • OEM/ODM via Hongtai — Custom voltage (180–440V, 50/60Hz), project branding and control protocols for tender-specific requirements.
Applications
  1. Open-Plan Office Floors — Repeat cassette grids install fast once the crew hits rhythm; central monitoring simplifies handover.
  2. Retail Floors and Supermarkets — 360° panels distribute evenly across sales areas; high ceilings covered by 3rd Gen DC up to 4.5m.
  3. Hotel Lobbies and Restaurants — Quiet DC operation and refined panel aesthetics match front-of-house standards.
  4. Classrooms and Training Centres — Occupancy sensing cuts runtime in intermittently used rooms.
  5. Clinics and Waiting Areas — Even four-way distribution eliminates draught complaints from seated patients.
Certifications & Standards
  • CE Marking — European conformity for safety and electromagnetic compatibility.
  • Eurovent Certified Performance — Third-party verified capacity and efficiency ratings.
  • ERP Compliant — Meets EU Energy-related Products Directive requirements.
  • RoHS Compliant — Restriction of Hazardous Substances directive conformance.
  • GB/T 19232 — Chinese national standard for fan coil unit performance testing.
Technical Specifications
Parameter AC Series DC Series
Airflow Range400–800 CFM400–1050 CFM
Cooling Capacity5.7–12.9 kW6.12–11.19 kW
Heating Capacity9.66–17.6 kW6.06–14.92 kW
Power Input84–190 W20–137 W
Sound Pressure Level (H)45–50 dB(A)39–49 dB(A)
Power Supply220–240V / 1Ph / 50Hz220–240V / 1Ph / 50Hz
Drain Pump Head750 mm750 mm (1200 mm for 3rd Gen)
Body Height230–300 mm230–300 mm
Coil Rows2–32–3
Max. Working Pressure1.6 MPa1.6 MPa
Motor TypeLow-noise 3-speed ACDC Brushless
Pipe ConnectionRC3/4"RC3/4"
Panel Options4-way / 360° / NEW 360°4-way / 360° / NEW 360°
AEH OptionAvailableAvailable
Pipe System2-pipe / 4-pipe2-pipe / 4-pipe
Product Gallery
Products
PRODUCTS DETAILS
Midea Four way Cassette Fan Coil Unit Platform One Chassis Three Panel Options 750mm Drain Pump
Detail Information
Place of Origin
China
Brand Name
OEM;MIDEA
Certification
CB,ISO
Product Name:
Four Way Cassette Fan Coil Unit
Airflow Range:
400–800 CFM 400–1050 CFM
Cooling Capacity:
5.7–12.9 KW 6.12–11.19 KW
Heating Capacity:
9.66–17.6 KW 6.06–14.92 KW
Power Input:
84–190 W 20–137 W
Sound Pressure Level (H):
45–50 DB(A) 39–49 DB(A)
Power Supply:
220–240V / 1Ph / 50Hz
Motor Type:
Low-noise 3-speed AC DC Brushless
Highlight

Midea four way cassette FCU

,

750mm drain pump fan coil

,

three panel options FCU

Product Description
Product Overview: Midea Four-Way Cassette Fan Coil Unit

Every contractor has a bread-and-butter cassette job — open-plan offices, retail floors, restaurants — where the same unit repeats across the ceiling grid bay after bay. The Midea Four-way Cassette Fan Coil Unit turns that repetition into profit: one chassis architecture spanning 400–1050 CFM across the AC and DC range, with cooling capacities from 5.7 to 12.9 kW, lets your crew standardise hangers, pipe connections and panel cut-outs across the entire floor. Order the chassis early and hit a rhythm — every unit after the first goes in faster.

Panels are the classic late-change killer on cassette jobs: the architect switches from four-way to 360° after rough-in, and suddenly you are re-ordering equipment. Not here. Classic four-outlet, 360° and NEW 360° panels all mount on the same chassis, so a design change costs a panel swap, not a return trip. Individual vane adjustment lets you balance airflow zone by zone at commissioning; two-pipe and four-pipe factory versions match whatever the building risers actually deliver; and the 750mm drain pump (1200mm on 3rd Generation DC) handles shallow and deep voids alike without condensate slope work.

For efficiency-driven tenders, the DC inverter brushless range cuts fan energy by up to 30% and noise by 2–5 dB(A), while 3rd Generation models add occupancy sensing for automatic setback in empty rooms, 4.5m ceiling capability for lobbies and atria, and native V8 integration for jobs pairing FCUs with Midea VRF outdoor systems. XYE and PQE ports plus GW-MOD(A) and GW-BAC(D) gateways make central control and Modbus/BACnet handover straightforward for the controls contractor. All models run on 220–240V / 1Ph / 50Hz, with OEM/ODM custom voltage, branding and protocol options available through Hongtai for export projects.

Key Selling Points
  • One Chassis, Three Panel Options — Classic 4-way, 360° and NEW 360° panels share one chassis; late design changes cost a panel swap, not a re-order.
  • Standardised Repeat Installs — Same hangers, pipe sizes and cut-outs across the floor; crews hit a rhythm and labour hours per unit drop.
  • Individual Vane Adjustment — Balance airflow zone by zone at commissioning without relocating units.
  • 750mm / 1200mm Drain Pump Range — Handles shallow and deep ceiling voids without condensate slope calculations.
  • 2-Pipe and 4-Pipe Factory Versions — Match building hydraulics exactly; no site adaptation or buffer vessels required.
  • Occupancy Sensing (3rd Gen DC) — Automatic setback in vacant zones; an easy energy-saving upsell for the building owner.
  • XYE / PQE Ports with Modbus & BACnet Gateways — Clean central-control and BMS handover without third-party interface hardware.
  • OEM/ODM via Hongtai — Custom voltage (180–440V, 50/60Hz), project branding and control protocols for tender-specific requirements.
Applications
  1. Open-Plan Office Floors — Repeat cassette grids install fast once the crew hits rhythm; central monitoring simplifies handover.
  2. Retail Floors and Supermarkets — 360° panels distribute evenly across sales areas; high ceilings covered by 3rd Gen DC up to 4.5m.
  3. Hotel Lobbies and Restaurants — Quiet DC operation and refined panel aesthetics match front-of-house standards.
  4. Classrooms and Training Centres — Occupancy sensing cuts runtime in intermittently used rooms.
  5. Clinics and Waiting Areas — Even four-way distribution eliminates draught complaints from seated patients.
Certifications & Standards
  • CE Marking — European conformity for safety and electromagnetic compatibility.
  • Eurovent Certified Performance — Third-party verified capacity and efficiency ratings.
  • ERP Compliant — Meets EU Energy-related Products Directive requirements.
  • RoHS Compliant — Restriction of Hazardous Substances directive conformance.
  • GB/T 19232 — Chinese national standard for fan coil unit performance testing.
Technical Specifications
Parameter AC Series DC Series
Airflow Range400–800 CFM400–1050 CFM
Cooling Capacity5.7–12.9 kW6.12–11.19 kW
Heating Capacity9.66–17.6 kW6.06–14.92 kW
Power Input84–190 W20–137 W
Sound Pressure Level (H)45–50 dB(A)39–49 dB(A)
Power Supply220–240V / 1Ph / 50Hz220–240V / 1Ph / 50Hz
Drain Pump Head750 mm750 mm (1200 mm for 3rd Gen)
Body Height230–300 mm230–300 mm
Coil Rows2–32–3
Max. Working Pressure1.6 MPa1.6 MPa
Motor TypeLow-noise 3-speed ACDC Brushless
Pipe ConnectionRC3/4"RC3/4"
Panel Options4-way / 360° / NEW 360°4-way / 360° / NEW 360°
AEH OptionAvailableAvailable
Pipe System2-pipe / 4-pipe2-pipe / 4-pipe
Product Gallery