On most open-plan floors the terminal unit is the last item to be frozen and the first to be challenged, because the ceiling layout, the diffuser pattern and the interior finish all move late in the programme. The Midea Four-way Cassette Fan Coil Unit is built to absorb that movement: one chassis architecture carries classic four-outlet, 360° and NEW 360° panels, so a change from a four-way layout to a circular pattern is a panel revision rather than an equipment variation. Across the combined AC and DC range the platform covers 400–1050 CFM and 5.7–12.9 kW of cooling, which means a single schedule line can serve offices, retail floors, restaurants, classrooms and waiting areas without a family of different selections.
The hydraulic and dimensional envelope is deliberately conventional, because that is what keeps coordination simple: RC3/4" connections, 230–300 mm body height, two-row and three-row coil options, factory-built two-pipe and four-pipe versions, a 1.6 MPa maximum working pressure and a 750 mm condensate lift pump, raised to 1200 mm on 3rd Generation DC models. Selecting two-pipe or four-pipe at order stage matches the riser design without site adaptation, while individual vane adjustment lets the airflow pattern be balanced zone by zone at commissioning rather than fixed by the factory. An electric auxiliary heating option is available where the heating source is not water-based.
For specifications that carry an energy or controls clause, the DC inverter brushless range reduces fan energy by up to 30% and sound pressure by 2–5 dB(A); 3rd Generation models add occupancy sensing for automatic setback in vacant zones, ceiling capability to 4.5 m for lobbies and atria, and native V8 integration where fan coils sit alongside Midea VRF outdoor systems. XYE and PQE ports with GW-MOD(A) and GW-BAC(D) gateways deliver Modbus RTU and BACnet from the factory, so the controls schedule does not depend on third-party interface hardware. All models run on 220–240V / 1Ph / 50Hz, with OEM/ODM custom voltage, branding and protocol support available through Hongtai.
For a base-build specification where the terminal units are priced on capital cost, the AC three-speed range is the straightforward choice: proven control, universal spares and the lowest unit rate on the schedule. Where the design carries an energy target, a controls sequence or an acoustic criterion — open-plan offices with green certification, retail floors with long occupancy hours — the DC inverter brushless range is the defensible selection: up to 30% lower fan energy, 2–5 dB(A) lower sound pressure, seven speeds for commissioning balance, and on 3rd Generation models occupancy sensing, 4.5 m ceiling capability and V8 integration. Panels, pumps, coil options and chassis dimensions are shared, so the two tiers coordinate identically on the reflected ceiling plan.
A: Specify the chassis as the controlled item — capacity, airflow, connections, pump lift and controls — and list the panel as a finish selection made with the interior designer. Because classic 4-way, 360° and NEW 360° panels mount on the same chassis, the panel decision can be taken after the equipment order without a variation.
A: No. The chassis is common at 230–300 mm body height across the range and the panel forms the finished ceiling face only. Void depth, hanger positions and service access are set by the chassis, so the ceiling zone can be coordinated before the panel is selected.
A: It removes the drainage constraint in double-height spaces, atria and long horizontal runs where a 750 mm lift would need an intermediate sump or a revised fall. Where the void geometry is uncertain at design stage, specifying the 1200 mm pump on the DC tier keeps the drainage design within one product.
A: XYE and PQE communication ports are integral to the unit, and GW-MOD(A) and GW-BAC(D) gateways provide Modbus RTU and BACnet respectively. Both are factory items, so the controls specification can name the protocol and point of connection without relying on a third-party interface.
A: Both are factory-built on the same chassis; the choice follows the riser design and whether the system provides heating and cooling from separate circuits. Selecting the correct version at order stage avoids site adaptation, and the 2-row or 3-row coil option then tunes capacity and water-side pressure drop to the plant.
| Parameter | AC Series | DC Series |
|---|---|---|
| Airflow Range | 400–800 CFM | 400–1050 CFM |
| Cooling Capacity | 5.7–12.9 kW | 6.12–11.19 kW |
| Heating Capacity | 9.66–17.6 kW | 6.06–14.92 kW |
| Power Input | 84–190 W | 20–137 W |
| Sound Pressure Level (H) | 45–50 dB(A) | 39–49 dB(A) |
| Power Supply | 220–240V / 1Ph / 50Hz | 220–240V / 1Ph / 50Hz |
| Drain Pump Head | 750 mm | 750 mm (1200 mm for 3rd Gen) |
| Body Height | 230–300 mm | 230–300 mm |
| Coil Rows | 2–3 | 2–3 |
| Max. Working Pressure | 1.6 MPa | 1.6 MPa |
| Motor Type | Low-noise 3-speed AC | DC Brushless |
| Pipe Connection | RC3/4" | RC3/4" |
| Panel Options | 4-way / 360° / NEW 360° | 4-way / 360° / NEW 360° |
| AEH Option | Available | Available |
| Pipe System | 2-pipe / 4-pipe | 2-pipe / 4-pipe |
Eurovent certified cassette fan coil · four way cassette FCU specification · 2 pipe 4 pipe cassette fan coil selection · Modbus BACnet cassette FCU · cassette fan coil 1200mm drain pump · occupancy sensor fan coil specification · 360 degree cassette panel options · V8 compatible cassette FCU
On most open-plan floors the terminal unit is the last item to be frozen and the first to be challenged, because the ceiling layout, the diffuser pattern and the interior finish all move late in the programme. The Midea Four-way Cassette Fan Coil Unit is built to absorb that movement: one chassis architecture carries classic four-outlet, 360° and NEW 360° panels, so a change from a four-way layout to a circular pattern is a panel revision rather than an equipment variation. Across the combined AC and DC range the platform covers 400–1050 CFM and 5.7–12.9 kW of cooling, which means a single schedule line can serve offices, retail floors, restaurants, classrooms and waiting areas without a family of different selections.
The hydraulic and dimensional envelope is deliberately conventional, because that is what keeps coordination simple: RC3/4" connections, 230–300 mm body height, two-row and three-row coil options, factory-built two-pipe and four-pipe versions, a 1.6 MPa maximum working pressure and a 750 mm condensate lift pump, raised to 1200 mm on 3rd Generation DC models. Selecting two-pipe or four-pipe at order stage matches the riser design without site adaptation, while individual vane adjustment lets the airflow pattern be balanced zone by zone at commissioning rather than fixed by the factory. An electric auxiliary heating option is available where the heating source is not water-based.
For specifications that carry an energy or controls clause, the DC inverter brushless range reduces fan energy by up to 30% and sound pressure by 2–5 dB(A); 3rd Generation models add occupancy sensing for automatic setback in vacant zones, ceiling capability to 4.5 m for lobbies and atria, and native V8 integration where fan coils sit alongside Midea VRF outdoor systems. XYE and PQE ports with GW-MOD(A) and GW-BAC(D) gateways deliver Modbus RTU and BACnet from the factory, so the controls schedule does not depend on third-party interface hardware. All models run on 220–240V / 1Ph / 50Hz, with OEM/ODM custom voltage, branding and protocol support available through Hongtai.
For a base-build specification where the terminal units are priced on capital cost, the AC three-speed range is the straightforward choice: proven control, universal spares and the lowest unit rate on the schedule. Where the design carries an energy target, a controls sequence or an acoustic criterion — open-plan offices with green certification, retail floors with long occupancy hours — the DC inverter brushless range is the defensible selection: up to 30% lower fan energy, 2–5 dB(A) lower sound pressure, seven speeds for commissioning balance, and on 3rd Generation models occupancy sensing, 4.5 m ceiling capability and V8 integration. Panels, pumps, coil options and chassis dimensions are shared, so the two tiers coordinate identically on the reflected ceiling plan.
A: Specify the chassis as the controlled item — capacity, airflow, connections, pump lift and controls — and list the panel as a finish selection made with the interior designer. Because classic 4-way, 360° and NEW 360° panels mount on the same chassis, the panel decision can be taken after the equipment order without a variation.
A: No. The chassis is common at 230–300 mm body height across the range and the panel forms the finished ceiling face only. Void depth, hanger positions and service access are set by the chassis, so the ceiling zone can be coordinated before the panel is selected.
A: It removes the drainage constraint in double-height spaces, atria and long horizontal runs where a 750 mm lift would need an intermediate sump or a revised fall. Where the void geometry is uncertain at design stage, specifying the 1200 mm pump on the DC tier keeps the drainage design within one product.
A: XYE and PQE communication ports are integral to the unit, and GW-MOD(A) and GW-BAC(D) gateways provide Modbus RTU and BACnet respectively. Both are factory items, so the controls specification can name the protocol and point of connection without relying on a third-party interface.
A: Both are factory-built on the same chassis; the choice follows the riser design and whether the system provides heating and cooling from separate circuits. Selecting the correct version at order stage avoids site adaptation, and the 2-row or 3-row coil option then tunes capacity and water-side pressure drop to the plant.
| Parameter | AC Series | DC Series |
|---|---|---|
| Airflow Range | 400–800 CFM | 400–1050 CFM |
| Cooling Capacity | 5.7–12.9 kW | 6.12–11.19 kW |
| Heating Capacity | 9.66–17.6 kW | 6.06–14.92 kW |
| Power Input | 84–190 W | 20–137 W |
| Sound Pressure Level (H) | 45–50 dB(A) | 39–49 dB(A) |
| Power Supply | 220–240V / 1Ph / 50Hz | 220–240V / 1Ph / 50Hz |
| Drain Pump Head | 750 mm | 750 mm (1200 mm for 3rd Gen) |
| Body Height | 230–300 mm | 230–300 mm |
| Coil Rows | 2–3 | 2–3 |
| Max. Working Pressure | 1.6 MPa | 1.6 MPa |
| Motor Type | Low-noise 3-speed AC | DC Brushless |
| Pipe Connection | RC3/4" | RC3/4" |
| Panel Options | 4-way / 360° / NEW 360° | 4-way / 360° / NEW 360° |
| AEH Option | Available | Available |
| Pipe System | 2-pipe / 4-pipe | 2-pipe / 4-pipe |
Eurovent certified cassette fan coil · four way cassette FCU specification · 2 pipe 4 pipe cassette fan coil selection · Modbus BACnet cassette FCU · cassette fan coil 1200mm drain pump · occupancy sensor fan coil specification · 360 degree cassette panel options · V8 compatible cassette FCU