logo
Products
PRODUCTS DETAILS
Home > Products >
Midea compact four way cassette FCU drops into 585mm grids for same day replacement body 204mm profile DC from 5W OEM ODM via Hongtai

Midea compact four way cassette FCU drops into 585mm grids for same day replacement body 204mm profile DC from 5W OEM ODM via Hongtai

Detail Information
Place of Origin
China
Brand Name
OEM;MIDEA
Certification
CB,ISO
Product Name:
Compact Four Way Cassette FCU
Airflow Range:
400–600 CFM
Cooling Capacity:
3.0–4.5 KW 2.98–4.78 KW
Heating Capacity:
4.0–6.0 KW 2.73–5.76 KW
Power Input:
30–95 W 5–43 W
Sound Pressure Level (H):
36–45 DB(A) 30–43 DB(A)
Power Supply:
220–240V / 1Ph / 50Hz
Motor Type:
Low-noise 3-speed AC DC Brushless
Highlight:

compact four way cassette FCU

,

585mm grid drop-in FCU replacement

,

204mm profile DC FCU OEM

Product Description
Product Overview

Every facility manager inherits them sooner or later: a fleet of ageing cassettes reaching end of life in an occupied building, where every replacement means tenant disruption, ceiling work and complaint risk. The Midea Compact Four-way Cassette Fan Coil Unit is sized to make the replacement programme painless — a 575×575mm body that drops straight into the standard 585mm ceiling grid used in commercial buildings worldwide. Pull the old unit, drop this one in, reconnect, commission. No grid cutting, no framing, no ceiling patching, no follow-up repairs. With 400–600 CFM and cooling capacities from 2.98 to 4.78 kW across the AC and DC range, it covers the small-to-medium zones — meeting rooms, guestrooms, clinics, office suites — that dominate any replacement schedule.

At 204mm body height — just 198mm on 3rd Generation DC models — the unit clears the shallow ceiling voids typical of older building stock, so modernisation reaches floors that standard cassettes cannot serve. The 500mm drain pump (1200mm on 3rd Gen) removes condensate positively, keeping leaks and the ceiling repairs they trigger off your work-order list. The integrated safety mesh protects your technicians during filter service, keeping site safety audits clean. And the standard 360° panel delivers even, draught-free air distribution with no vane balancing after the swap — one less reason for occupants to call.

The DC inverter brushless version draws as little as 5W at low speed and cuts fan energy by up to 30% — the payback line that makes whole-floor replacement budgets easier to approve. Seven fan speeds via the KJR-75A controller let your team tune each room at handback, and 2-pipe or 4-pipe factory versions match whatever hydraulics the existing building gives you. All models run on 220–240V / 1Ph / 50Hz, and Hongtai supports multi-year, multi-site replacement programmes with OEM/ODM customisation — custom voltages from 180–440V at 50/60Hz, project branding, and Modbus/BACnet protocols — plus steady spare-parts supply across the contract period.

Key Selling Points
  • 575×575mm Drop-In Dimensions — Fits standard 585mm ceiling grids with zero rework; same-day swaps keep tenants in place.
  • 204mm / 198mm Shallow-Void Height — Modernises older buildings whose tight voids defeat standard cassettes.
  • 500mm / 1200mm Drain Pump — Positive condensate removal keeps leaks and ceiling repairs off the work-order list.
  • Integrated Safety Mesh — Protects technicians during filter service; supports clean site safety audits.
  • Standard 360° Panel — Even, draught-free distribution with no vane balancing after each swap.
  • DC From 5W Low-Speed Draw — Up to 30% energy saving builds the payback case for whole-floor replacement.
  • 2-Pipe and 4-Pipe Versions — Match existing hydraulics in any retrofit without plant-room changes.
  • OEM/ODM Rollout Support via Hongtai — Custom voltage, branding and protocols plus spare-parts continuity for multi-site contracts.
AC vs DC — Which Should You Specify?

For like-for-like swaps under fixed maintenance budgets, the AC version keeps unit cost low and the job simple. For whole-floor or whole-building replacement programmes that must be defended to finance, the DC inverter brushless version is the stronger case: from 5W at low speed, up to 30% less fan energy, seven speeds via the KJR-75A, and 198mm height on 3rd Generation models for the shallowest voids. Dimensions, grid fit and pipe connections are identical — so your team services both versions with the same routine and the same spares.

Applications
  1. Occupied Office Floor Refurbishment — Same-day swaps keep tenants working; disruption measured in hours, not days.
  2. Hotel Guestroom Upgrades — Compact height fits shallow bathroom-lobby ceilings; quiet DC operation protects guest satisfaction.
  3. Clinics and Treatment Rooms — Safety mesh and low-noise DC models suit healthcare compliance regimes.
  4. Meeting Rooms and Small Offices — Right-sized 400–600 CFM capacity avoids over-conditioning small zones.
  5. Multi-Site Retail and Franchise Estates — One standardised unit across every site simplifies training and spares holding.
Frequently Asked Questions
Q: Can we replace old cassettes without closing the floor?

A: Yes. The 575×575mm body drops straight into the existing 585mm grid — pull the old unit, set the new one, reconnect and commission. Most swaps complete the same day with zero ceiling rework, so tenants stay in place throughout.

Q: How disruptive is the work for occupants?

A: Minimal. There is no grid cutting, framing or ceiling patching — which means no dust, no repainting and no follow-up repair visits. Disruption is measured in hours per unit, not days per zone.

Q: Our building is old and the ceiling voids are shallow — will it fit?

A: The body is 204mm high — just 198mm on 3rd Generation DC models — clearing shallow voids that defeat standard cassettes. Confirm hanger and service clearances against the installation manual for each floor.

Q: How quiet is the DC version after replacement?

A: The DC range runs from 30 dB(A) at high speed and quieter still at reduced speeds — comfortable for hotel guestrooms, clinics and meeting rooms where noise complaints are most costly.

Q: Will spares be available across a multi-year replacement programme?

A: Yes. Hongtai backs multi-site rollouts with steady spare-parts supply across the contract period, plus OEM/ODM customisation where individual sites need it.

Certifications & Standards
  • CE Marking — European conformity for safety and electromagnetic compatibility.
  • Eurovent Certified Performance — Third-party verified capacity and efficiency ratings.
  • ERP Compliant — Meets EU Energy-related Products Directive requirements.
  • RoHS Compliant — Restriction of Hazardous Substances directive conformance.
  • GB/T 19232 — Chinese national standard for fan coil unit performance testing.
Technical Specifications
Parameter AC Series DC Series
Airflow Range400–600 CFM400–600 CFM
Cooling Capacity3.0–4.5 kW2.98–4.78 kW
Heating Capacity4.0–6.0 kW2.73–5.76 kW
Power Input30–95 W5–43 W
Sound Pressure Level (H)36–45 dB(A)30–43 dB(A)
Power Supply220–240V / 1Ph / 50Hz220–240V / 1Ph / 50Hz
Drain Pump Head500 mm500 mm (1200 mm for 3rd Gen)
Body Height204 mm204 mm (198 mm for 3rd Gen)
Body Dimensions575×575 mm575×575 mm
Coil Rows22
Max. Working Pressure1.6 MPa1.6 MPa
Motor TypeLow-noise 3-speed ACDC Brushless
Pipe ConnectionG3/4"G3/4"
AEH OptionAvailableAvailable
Pipe System2-pipe / 4-pipe2-pipe / 4-pipe
Related Search Terms

compact cassette fan coil replacement · 575x575 cassette FCU 585 grid · same day cassette replacement unit · shallow ceiling cassette fan coil · quiet DC cassette for hotel rooms · low energy cassette FCU 5W · cassette FCU spare parts supply · office cassette retrofit no rework

Products
PRODUCTS DETAILS
Midea compact four way cassette FCU drops into 585mm grids for same day replacement body 204mm profile DC from 5W OEM ODM via Hongtai
Detail Information
Place of Origin
China
Brand Name
OEM;MIDEA
Certification
CB,ISO
Product Name:
Compact Four Way Cassette FCU
Airflow Range:
400–600 CFM
Cooling Capacity:
3.0–4.5 KW 2.98–4.78 KW
Heating Capacity:
4.0–6.0 KW 2.73–5.76 KW
Power Input:
30–95 W 5–43 W
Sound Pressure Level (H):
36–45 DB(A) 30–43 DB(A)
Power Supply:
220–240V / 1Ph / 50Hz
Motor Type:
Low-noise 3-speed AC DC Brushless
Highlight

compact four way cassette FCU

,

585mm grid drop-in FCU replacement

,

204mm profile DC FCU OEM

Product Description
Product Overview

Every facility manager inherits them sooner or later: a fleet of ageing cassettes reaching end of life in an occupied building, where every replacement means tenant disruption, ceiling work and complaint risk. The Midea Compact Four-way Cassette Fan Coil Unit is sized to make the replacement programme painless — a 575×575mm body that drops straight into the standard 585mm ceiling grid used in commercial buildings worldwide. Pull the old unit, drop this one in, reconnect, commission. No grid cutting, no framing, no ceiling patching, no follow-up repairs. With 400–600 CFM and cooling capacities from 2.98 to 4.78 kW across the AC and DC range, it covers the small-to-medium zones — meeting rooms, guestrooms, clinics, office suites — that dominate any replacement schedule.

At 204mm body height — just 198mm on 3rd Generation DC models — the unit clears the shallow ceiling voids typical of older building stock, so modernisation reaches floors that standard cassettes cannot serve. The 500mm drain pump (1200mm on 3rd Gen) removes condensate positively, keeping leaks and the ceiling repairs they trigger off your work-order list. The integrated safety mesh protects your technicians during filter service, keeping site safety audits clean. And the standard 360° panel delivers even, draught-free air distribution with no vane balancing after the swap — one less reason for occupants to call.

The DC inverter brushless version draws as little as 5W at low speed and cuts fan energy by up to 30% — the payback line that makes whole-floor replacement budgets easier to approve. Seven fan speeds via the KJR-75A controller let your team tune each room at handback, and 2-pipe or 4-pipe factory versions match whatever hydraulics the existing building gives you. All models run on 220–240V / 1Ph / 50Hz, and Hongtai supports multi-year, multi-site replacement programmes with OEM/ODM customisation — custom voltages from 180–440V at 50/60Hz, project branding, and Modbus/BACnet protocols — plus steady spare-parts supply across the contract period.

Key Selling Points
  • 575×575mm Drop-In Dimensions — Fits standard 585mm ceiling grids with zero rework; same-day swaps keep tenants in place.
  • 204mm / 198mm Shallow-Void Height — Modernises older buildings whose tight voids defeat standard cassettes.
  • 500mm / 1200mm Drain Pump — Positive condensate removal keeps leaks and ceiling repairs off the work-order list.
  • Integrated Safety Mesh — Protects technicians during filter service; supports clean site safety audits.
  • Standard 360° Panel — Even, draught-free distribution with no vane balancing after each swap.
  • DC From 5W Low-Speed Draw — Up to 30% energy saving builds the payback case for whole-floor replacement.
  • 2-Pipe and 4-Pipe Versions — Match existing hydraulics in any retrofit without plant-room changes.
  • OEM/ODM Rollout Support via Hongtai — Custom voltage, branding and protocols plus spare-parts continuity for multi-site contracts.
AC vs DC — Which Should You Specify?

For like-for-like swaps under fixed maintenance budgets, the AC version keeps unit cost low and the job simple. For whole-floor or whole-building replacement programmes that must be defended to finance, the DC inverter brushless version is the stronger case: from 5W at low speed, up to 30% less fan energy, seven speeds via the KJR-75A, and 198mm height on 3rd Generation models for the shallowest voids. Dimensions, grid fit and pipe connections are identical — so your team services both versions with the same routine and the same spares.

Applications
  1. Occupied Office Floor Refurbishment — Same-day swaps keep tenants working; disruption measured in hours, not days.
  2. Hotel Guestroom Upgrades — Compact height fits shallow bathroom-lobby ceilings; quiet DC operation protects guest satisfaction.
  3. Clinics and Treatment Rooms — Safety mesh and low-noise DC models suit healthcare compliance regimes.
  4. Meeting Rooms and Small Offices — Right-sized 400–600 CFM capacity avoids over-conditioning small zones.
  5. Multi-Site Retail and Franchise Estates — One standardised unit across every site simplifies training and spares holding.
Frequently Asked Questions
Q: Can we replace old cassettes without closing the floor?

A: Yes. The 575×575mm body drops straight into the existing 585mm grid — pull the old unit, set the new one, reconnect and commission. Most swaps complete the same day with zero ceiling rework, so tenants stay in place throughout.

Q: How disruptive is the work for occupants?

A: Minimal. There is no grid cutting, framing or ceiling patching — which means no dust, no repainting and no follow-up repair visits. Disruption is measured in hours per unit, not days per zone.

Q: Our building is old and the ceiling voids are shallow — will it fit?

A: The body is 204mm high — just 198mm on 3rd Generation DC models — clearing shallow voids that defeat standard cassettes. Confirm hanger and service clearances against the installation manual for each floor.

Q: How quiet is the DC version after replacement?

A: The DC range runs from 30 dB(A) at high speed and quieter still at reduced speeds — comfortable for hotel guestrooms, clinics and meeting rooms where noise complaints are most costly.

Q: Will spares be available across a multi-year replacement programme?

A: Yes. Hongtai backs multi-site rollouts with steady spare-parts supply across the contract period, plus OEM/ODM customisation where individual sites need it.

Certifications & Standards
  • CE Marking — European conformity for safety and electromagnetic compatibility.
  • Eurovent Certified Performance — Third-party verified capacity and efficiency ratings.
  • ERP Compliant — Meets EU Energy-related Products Directive requirements.
  • RoHS Compliant — Restriction of Hazardous Substances directive conformance.
  • GB/T 19232 — Chinese national standard for fan coil unit performance testing.
Technical Specifications
Parameter AC Series DC Series
Airflow Range400–600 CFM400–600 CFM
Cooling Capacity3.0–4.5 kW2.98–4.78 kW
Heating Capacity4.0–6.0 kW2.73–5.76 kW
Power Input30–95 W5–43 W
Sound Pressure Level (H)36–45 dB(A)30–43 dB(A)
Power Supply220–240V / 1Ph / 50Hz220–240V / 1Ph / 50Hz
Drain Pump Head500 mm500 mm (1200 mm for 3rd Gen)
Body Height204 mm204 mm (198 mm for 3rd Gen)
Body Dimensions575×575 mm575×575 mm
Coil Rows22
Max. Working Pressure1.6 MPa1.6 MPa
Motor TypeLow-noise 3-speed ACDC Brushless
Pipe ConnectionG3/4"G3/4"
AEH OptionAvailableAvailable
Pipe System2-pipe / 4-pipe2-pipe / 4-pipe
Related Search Terms

compact cassette fan coil replacement · 575x575 cassette FCU 585 grid · same day cassette replacement unit · shallow ceiling cassette fan coil · quiet DC cassette for hotel rooms · low energy cassette FCU 5W · cassette FCU spare parts supply · office cassette retrofit no rework

Sitemap |  Privacy Policy | China Good Quality DC Inverter VRF Supplier. Copyright © 2024-2026 Henan Hongtai HVAC Equipment Co., Ltd. . All Rights Reserved.