Midea Compact Cassette FCU Retrofit 204mm Deep No Rework DC Compact Cassette FCU 5W Low Speed 30 Fan Saving

Midea Compact Cassette FCU Retrofit 204mm Deep No Rework DC Compact Cassette FCU 5W Low Speed 30 Fan Saving

Detail Information
Place of Origin
China
Brand Name
OEM;MIDEA
Certification
CB,ISO
Product Name:
Compact Four Way Cassette FCU
Airflow Range:
400–600 CFM
Cooling Capacity:
3.0–4.5 KW 2.98–4.78 KW
Heating Capacity:
4.0–6.0 KW 2.73–5.76 KW
Power Input:
30–95 W 5–43 W
Sound Pressure Level (H):
36–45 DB(A) 30–43 DB(A)
Power Supply:
220–240V / 1Ph / 50Hz
Motor Type:
Low-noise 3-speed AC DC Brushless
Highlight:

compact cassette FCU retrofit

,

204mm deep cassette FCU

,

5W low speed cassette FCU

Product Description
Product Overview

Refurbishment and tenant fit-out projects are where terminal unit selections are most often reopened, because the existing ceiling module rarely matches the drawing set. The Midea Compact Four-way Cassette Fan Coil Unit is dimensioned for that reality: a 575×575mm body that drops into the standard 585mm ceiling grid used in commercial buildings worldwide, with no grid cutting, no bespoke framing and no ceiling patching. Across the combined AC and DC range it covers 400–600 CFM and 2.98–4.78 kW of cooling — the small-to-medium zone band that dominates refurbishment schedules — and Eurovent-certified figures allow a like-for-like replacement to be specified on performance.

The section is where this unit earns its place on a design drawing: 204mm body height, reduced to 198mm on 3rd Generation DC models, clears the shallow slab-to-slab zones in older buildings that rule out standard cassettes. The 500mm condensate lift pump — 1200mm on 3rd Generation DC — removes drainage fall from the coordination problem, and the integrated safety mesh protects maintenance staff during filter service without adding a removable guard to the specification. A standard 360° panel provides even distribution with no vane balancing at commissioning, and the two-row coil, G3/4" connections and 1.6 MPa maximum working pressure sit within normal chilled and low-temperature hot water practice. Factory two-pipe and four-pipe versions match the existing hydraulics, and an electric auxiliary heating option is available.

For whole-floor replacement strategies the DC inverter brushless version is the stronger line in the report: a minimum draw of 5W at low speed, up to 30% lower fan energy and sound pressure from 30 dB(A), with seven speeds through the KJR-75A controller for room-by-room balance at handover. All models run on 220–240V / 1Ph / 50Hz. Hongtai supports multi-site and chain-wide programmes with OEM/ODM customisation — custom voltages from 180–440V at 50/60Hz, project branding, and Modbus or BACnet protocols — so a standard specification can be applied across a portfolio without a separate approval route in each country.

Key Selling Points
  • 575 × 575mm Within a 585mm Grid — Fits the standard ceiling module without cutting, framing or patching; the replacement stays a replacement.
  • 204mm / 198mm Section Depth — Clears shallow slab-to-slab zones in existing buildings where standard cassettes cannot be scheduled.
  • 500mm / 1200mm Lift Pump — Removes drainage fall from the coordination problem; no structural drainage alteration.
  • Standard 360° Panel — Even distribution without vane balancing, reducing commissioning tasks per unit.
  • Integrated Safety Mesh — Protects maintenance staff during filter service without a separate guard item in the specification.
  • DC from 5W at Low Speed — Up to 30% lower fan energy supports whole-floor replacement cases and energy-audit reporting.
  • 2-Pipe and 4-Pipe Factory Versions — Matches the existing riser arrangement without site adaptation.
  • AEH Option — Electric auxiliary heating available where the existing heating source is not water-based.
  • OEM/ODM Programme Support via Hongtai — Custom voltage, branding and protocols with spare-parts continuity across multi-site contracts.
AC vs DC — Which Should You Specify?

Where the replacement is defined by an insurance settlement or a fixed refurbishment budget, the AC three-speed version keeps the intervention simple and the unit rate low, with a control philosophy that matches whatever the building already has. Where the design is being reported against an energy target, or the landlord will carry the running cost for a decade, the DC inverter brushless version is the better case: 5W at low speed, up to 30% lower fan energy, seven speeds through the KJR-75A controller and 198mm section depth on 3rd Generation models for the tightest voids. Dimensions, grid fit, connections and panel are identical, so the hydraulic and ceiling drawings do not change with the motor tier.

Applications
  1. Office Suite Refurbishment — Drop-in replacement keeps tenant downtime measured in hours; the existing ceiling module is reused.
  2. Hotel Guestroom Renovation — Compact section depth suits shallow bathroom and lobby ceilings; the DC tier supports guestroom acoustic criteria.
  3. Clinics and Treatment Rooms — Safety mesh and low sound pressure support healthcare maintenance and acoustic requirements.
  4. Meeting Rooms and Cellular Offices — Right-sized 400–600 CFM band avoids over-conditioning small zones and short-cycling.
  5. Chain and Franchise Fit-Out — One standardised unit across every site simplifies the specification, the spares holding and the O&M documentation.
Frequently Asked Questions
Q: Will it fit an existing 585mm ceiling grid without modification?

A: Yes. The 575×575mm body is dimensioned for the standard 585mm module used in commercial buildings, so the existing grid, hangers and ceiling tiles are retained. Where the existing grid is non-standard, the module should be confirmed on site before the equipment order is placed.

Q: What slab-to-slab allowance should I carry for the unit?

A: The body is 204mm high, and 198mm on 3rd Generation DC models. Add the hanger and service clearances given in the installation manual to arrive at the required void, then compare against the structural zone; the DC tier is normally the correct selection where the void is the constraint.

Q: The specification names a four-way cassette — does a 360° panel comply?

A: The standard panel distributes through a circular outlet on the same chassis, so the terminal unit, capacity and connections are unchanged. If the specification is written around a four-outlet pattern, the requirement should be worded around the chassis and the distribution pattern rather than the panel type.

Q: Can the 5W low-speed figure be used in energy calculations?

A: It is the verified minimum power input of the DC range at low speed, and it should be used with the design airflow and the expected speed profile rather than as an average. Applied that way, the up to 30% fan energy reduction against the AC equivalent is a defensible input to a whole-floor replacement case.

Q: Are the two-pipe and four-pipe versions both available with electric heating?

A: Yes. Factory two-pipe and four-pipe versions are both offered, and the electric auxiliary heating option is available across them, so the heating source can be resolved without changing the terminal unit family.

Certifications & Standards
  • CE Marking — European conformity for safety and electromagnetic compatibility.
  • Eurovent Certified Performance — Third-party verified capacity and efficiency ratings.
  • ERP Compliant — Meets EU Energy-related Products Directive requirements.
  • RoHS Compliant — Restriction of Hazardous Substances directive conformance.
  • GB/T 19232 — Chinese national standard for fan coil unit performance testing.
Technical Specifications
Parameter AC Series DC Series
Airflow Range 400–600 CFM 400–600 CFM
Cooling Capacity 3.0–4.5 kW 2.98–4.78 kW
Heating Capacity 4.0–6.0 kW 2.73–5.76 kW
Power Input 30–95 W 5–43 W
Sound Pressure Level (H) 36–45 dB(A) 30–43 dB(A)
Power Supply 220–240V / 1Ph / 50Hz 220–240V / 1Ph / 50Hz
Drain Pump Head 500 mm 500 mm (1200 mm for 3rd Gen)
Body Height 204 mm 204 mm (198 mm for 3rd Gen)
Body Dimensions 575×575 mm 575×575 mm
Coil Rows 2 2
Max. Working Pressure 1.6 MPa 1.6 MPa
Motor Type Low-noise 3-speed AC DC Brushless
Pipe Connection G3/4" G3/4"
AEH Option Available Available
Pipe System 2-pipe / 4-pipe 2-pipe / 4-pipe
Related Search Terms
  • compact cassette fan coil unit
  • 575x575 cassette FCU specification
  • 585mm ceiling grid fan coil
  • cassette FCU retrofit no rework
  • shallow void cassette FCU
  • Eurovent certified compact cassette
  • DC compact cassette fan coil
  • 2 pipe 4 pipe compact cassette
Product Gallery
Products
PRODUCTS DETAILS
Midea Compact Cassette FCU Retrofit 204mm Deep No Rework DC Compact Cassette FCU 5W Low Speed 30 Fan Saving
Detail Information
Place of Origin
China
Brand Name
OEM;MIDEA
Certification
CB,ISO
Product Name:
Compact Four Way Cassette FCU
Airflow Range:
400–600 CFM
Cooling Capacity:
3.0–4.5 KW 2.98–4.78 KW
Heating Capacity:
4.0–6.0 KW 2.73–5.76 KW
Power Input:
30–95 W 5–43 W
Sound Pressure Level (H):
36–45 DB(A) 30–43 DB(A)
Power Supply:
220–240V / 1Ph / 50Hz
Motor Type:
Low-noise 3-speed AC DC Brushless
Highlight

compact cassette FCU retrofit

,

204mm deep cassette FCU

,

5W low speed cassette FCU

Product Description
Product Overview

Refurbishment and tenant fit-out projects are where terminal unit selections are most often reopened, because the existing ceiling module rarely matches the drawing set. The Midea Compact Four-way Cassette Fan Coil Unit is dimensioned for that reality: a 575×575mm body that drops into the standard 585mm ceiling grid used in commercial buildings worldwide, with no grid cutting, no bespoke framing and no ceiling patching. Across the combined AC and DC range it covers 400–600 CFM and 2.98–4.78 kW of cooling — the small-to-medium zone band that dominates refurbishment schedules — and Eurovent-certified figures allow a like-for-like replacement to be specified on performance.

The section is where this unit earns its place on a design drawing: 204mm body height, reduced to 198mm on 3rd Generation DC models, clears the shallow slab-to-slab zones in older buildings that rule out standard cassettes. The 500mm condensate lift pump — 1200mm on 3rd Generation DC — removes drainage fall from the coordination problem, and the integrated safety mesh protects maintenance staff during filter service without adding a removable guard to the specification. A standard 360° panel provides even distribution with no vane balancing at commissioning, and the two-row coil, G3/4" connections and 1.6 MPa maximum working pressure sit within normal chilled and low-temperature hot water practice. Factory two-pipe and four-pipe versions match the existing hydraulics, and an electric auxiliary heating option is available.

For whole-floor replacement strategies the DC inverter brushless version is the stronger line in the report: a minimum draw of 5W at low speed, up to 30% lower fan energy and sound pressure from 30 dB(A), with seven speeds through the KJR-75A controller for room-by-room balance at handover. All models run on 220–240V / 1Ph / 50Hz. Hongtai supports multi-site and chain-wide programmes with OEM/ODM customisation — custom voltages from 180–440V at 50/60Hz, project branding, and Modbus or BACnet protocols — so a standard specification can be applied across a portfolio without a separate approval route in each country.

Key Selling Points
  • 575 × 575mm Within a 585mm Grid — Fits the standard ceiling module without cutting, framing or patching; the replacement stays a replacement.
  • 204mm / 198mm Section Depth — Clears shallow slab-to-slab zones in existing buildings where standard cassettes cannot be scheduled.
  • 500mm / 1200mm Lift Pump — Removes drainage fall from the coordination problem; no structural drainage alteration.
  • Standard 360° Panel — Even distribution without vane balancing, reducing commissioning tasks per unit.
  • Integrated Safety Mesh — Protects maintenance staff during filter service without a separate guard item in the specification.
  • DC from 5W at Low Speed — Up to 30% lower fan energy supports whole-floor replacement cases and energy-audit reporting.
  • 2-Pipe and 4-Pipe Factory Versions — Matches the existing riser arrangement without site adaptation.
  • AEH Option — Electric auxiliary heating available where the existing heating source is not water-based.
  • OEM/ODM Programme Support via Hongtai — Custom voltage, branding and protocols with spare-parts continuity across multi-site contracts.
AC vs DC — Which Should You Specify?

Where the replacement is defined by an insurance settlement or a fixed refurbishment budget, the AC three-speed version keeps the intervention simple and the unit rate low, with a control philosophy that matches whatever the building already has. Where the design is being reported against an energy target, or the landlord will carry the running cost for a decade, the DC inverter brushless version is the better case: 5W at low speed, up to 30% lower fan energy, seven speeds through the KJR-75A controller and 198mm section depth on 3rd Generation models for the tightest voids. Dimensions, grid fit, connections and panel are identical, so the hydraulic and ceiling drawings do not change with the motor tier.

Applications
  1. Office Suite Refurbishment — Drop-in replacement keeps tenant downtime measured in hours; the existing ceiling module is reused.
  2. Hotel Guestroom Renovation — Compact section depth suits shallow bathroom and lobby ceilings; the DC tier supports guestroom acoustic criteria.
  3. Clinics and Treatment Rooms — Safety mesh and low sound pressure support healthcare maintenance and acoustic requirements.
  4. Meeting Rooms and Cellular Offices — Right-sized 400–600 CFM band avoids over-conditioning small zones and short-cycling.
  5. Chain and Franchise Fit-Out — One standardised unit across every site simplifies the specification, the spares holding and the O&M documentation.
Frequently Asked Questions
Q: Will it fit an existing 585mm ceiling grid without modification?

A: Yes. The 575×575mm body is dimensioned for the standard 585mm module used in commercial buildings, so the existing grid, hangers and ceiling tiles are retained. Where the existing grid is non-standard, the module should be confirmed on site before the equipment order is placed.

Q: What slab-to-slab allowance should I carry for the unit?

A: The body is 204mm high, and 198mm on 3rd Generation DC models. Add the hanger and service clearances given in the installation manual to arrive at the required void, then compare against the structural zone; the DC tier is normally the correct selection where the void is the constraint.

Q: The specification names a four-way cassette — does a 360° panel comply?

A: The standard panel distributes through a circular outlet on the same chassis, so the terminal unit, capacity and connections are unchanged. If the specification is written around a four-outlet pattern, the requirement should be worded around the chassis and the distribution pattern rather than the panel type.

Q: Can the 5W low-speed figure be used in energy calculations?

A: It is the verified minimum power input of the DC range at low speed, and it should be used with the design airflow and the expected speed profile rather than as an average. Applied that way, the up to 30% fan energy reduction against the AC equivalent is a defensible input to a whole-floor replacement case.

Q: Are the two-pipe and four-pipe versions both available with electric heating?

A: Yes. Factory two-pipe and four-pipe versions are both offered, and the electric auxiliary heating option is available across them, so the heating source can be resolved without changing the terminal unit family.

Certifications & Standards
  • CE Marking — European conformity for safety and electromagnetic compatibility.
  • Eurovent Certified Performance — Third-party verified capacity and efficiency ratings.
  • ERP Compliant — Meets EU Energy-related Products Directive requirements.
  • RoHS Compliant — Restriction of Hazardous Substances directive conformance.
  • GB/T 19232 — Chinese national standard for fan coil unit performance testing.
Technical Specifications
Parameter AC Series DC Series
Airflow Range 400–600 CFM 400–600 CFM
Cooling Capacity 3.0–4.5 kW 2.98–4.78 kW
Heating Capacity 4.0–6.0 kW 2.73–5.76 kW
Power Input 30–95 W 5–43 W
Sound Pressure Level (H) 36–45 dB(A) 30–43 dB(A)
Power Supply 220–240V / 1Ph / 50Hz 220–240V / 1Ph / 50Hz
Drain Pump Head 500 mm 500 mm (1200 mm for 3rd Gen)
Body Height 204 mm 204 mm (198 mm for 3rd Gen)
Body Dimensions 575×575 mm 575×575 mm
Coil Rows 2 2
Max. Working Pressure 1.6 MPa 1.6 MPa
Motor Type Low-noise 3-speed AC DC Brushless
Pipe Connection G3/4" G3/4"
AEH Option Available Available
Pipe System 2-pipe / 4-pipe 2-pipe / 4-pipe
Related Search Terms
  • compact cassette fan coil unit
  • 575x575 cassette FCU specification
  • 585mm ceiling grid fan coil
  • cassette FCU retrofit no rework
  • shallow void cassette FCU
  • Eurovent certified compact cassette
  • DC compact cassette fan coil
  • 2 pipe 4 pipe compact cassette