Concealed ducted work is where drawings meet reality — and reality usually wins. The Midea Medium Static Pressure Duct Fan Coil Unit is engineered to absorb the gaps between design and as-built conditions instead of making you pay for them. On AC models, water connections reverse from left to right on site; on DC models, external static pressure is selectable at 12, 30 or 50Pa via the PCB or wired controller. Return air draws from the rear or the bottom. When the riser ends up on the wrong side or the duct run grows two extra bends, the unit adapts — no re-ordering, no return trips, no change-order arguments. One family spans 400–1200 CFM with cooling capacities from 2.35 to 13.78 kW across the AC and DC range.
At 241mm body height (261mm for DC), the chassis hides above standard ceiling grids, while three-row and four-row coil options match two-pipe or four-pipe hydraulics across new-build and retrofit jobs. The enlarged drain pan option is low-cost insurance against the call-back every contractor dreads: condensation stains on a finished ceiling. The filter assembly extracts in multiple directions, so maintenance access works however the ceiling void ended up being built — your service team will not be inventing access solutions on every visit.
The DC inverter brushless range provides seven fan speeds for precise airflow balancing at commissioning, up to 30% lower fan energy, and native V8 controller integration for jobs pairing FCUs with Midea VRF outdoor systems. XYE and PQE ports simplify central control and Modbus RTU handover to the BMS contractor. Standard supply is 220–240V / 1Ph / 50Hz; for export contracts, Hongtai provides OEM/ODM support with custom voltages from 180–440V at 50/60Hz, project branding and protocol options.
| Parameter | AC Series | DC Series |
|---|---|---|
| Airflow Range | 400–1200 CFM | 400–1200 CFM |
| Cooling Capacity | 2.35–13.0 kW | 2.35–13.78 kW |
| Heating Capacity | 3.90–22.17 kW | 3.90–13.30 kW |
| Power Input | 36–221 W | 5–552 W |
| Sound Pressure Level (H) | 35–52 dB(A) | 29–58 dB(A) |
| Power Supply | 220–240V / 1Ph / 50Hz | 220–240V / 1Ph / 50Hz |
| Body Height | 241 mm | 261 mm |
| External Static Pressure | 12/30/50 Pa (customizable) | 12/30/50 Pa (adjustable) |
| Coil Rows | 3 / 4 | 3 / 4 |
| Max. Working Pressure | 1.6 MPa | 1.6 MPa |
| Motor Type | Low-noise 3-speed AC | DC Brushless |
| Pipe Connection | RC3/4" | RC3/4" |
| AEH Option | Available | Available |
| Pipe System | 2-pipe / 4-pipe | 2-pipe / 4-pipe |
Concealed ducted work is where drawings meet reality — and reality usually wins. The Midea Medium Static Pressure Duct Fan Coil Unit is engineered to absorb the gaps between design and as-built conditions instead of making you pay for them. On AC models, water connections reverse from left to right on site; on DC models, external static pressure is selectable at 12, 30 or 50Pa via the PCB or wired controller. Return air draws from the rear or the bottom. When the riser ends up on the wrong side or the duct run grows two extra bends, the unit adapts — no re-ordering, no return trips, no change-order arguments. One family spans 400–1200 CFM with cooling capacities from 2.35 to 13.78 kW across the AC and DC range.
At 241mm body height (261mm for DC), the chassis hides above standard ceiling grids, while three-row and four-row coil options match two-pipe or four-pipe hydraulics across new-build and retrofit jobs. The enlarged drain pan option is low-cost insurance against the call-back every contractor dreads: condensation stains on a finished ceiling. The filter assembly extracts in multiple directions, so maintenance access works however the ceiling void ended up being built — your service team will not be inventing access solutions on every visit.
The DC inverter brushless range provides seven fan speeds for precise airflow balancing at commissioning, up to 30% lower fan energy, and native V8 controller integration for jobs pairing FCUs with Midea VRF outdoor systems. XYE and PQE ports simplify central control and Modbus RTU handover to the BMS contractor. Standard supply is 220–240V / 1Ph / 50Hz; for export contracts, Hongtai provides OEM/ODM support with custom voltages from 180–440V at 50/60Hz, project branding and protocol options.
| Parameter | AC Series | DC Series |
|---|---|---|
| Airflow Range | 400–1200 CFM | 400–1200 CFM |
| Cooling Capacity | 2.35–13.0 kW | 2.35–13.78 kW |
| Heating Capacity | 3.90–22.17 kW | 3.90–13.30 kW |
| Power Input | 36–221 W | 5–552 W |
| Sound Pressure Level (H) | 35–52 dB(A) | 29–58 dB(A) |
| Power Supply | 220–240V / 1Ph / 50Hz | 220–240V / 1Ph / 50Hz |
| Body Height | 241 mm | 261 mm |
| External Static Pressure | 12/30/50 Pa (customizable) | 12/30/50 Pa (adjustable) |
| Coil Rows | 3 / 4 | 3 / 4 |
| Max. Working Pressure | 1.6 MPa | 1.6 MPa |
| Motor Type | Low-noise 3-speed AC | DC Brushless |
| Pipe Connection | RC3/4" | RC3/4" |
| AEH Option | Available | Available |
| Pipe System | 2-pipe / 4-pipe | 2-pipe / 4-pipe |