logo
Products
PRODUCTS DETAILS
Home > Products >
Medium Static Duct FCU Concealed Quiet and Easy to Service Reversible Piping Duct FCU Fewer Surprises Behind the Ceiling

Medium Static Duct FCU Concealed Quiet and Easy to Service Reversible Piping Duct FCU Fewer Surprises Behind the Ceiling

Detail Information
Place of Origin
China
Brand Name
OEM;MIDEA
Certification
CB,ISO
Product Name:
Medium Static Duct FCU
Airflow Range:
400–1200 CFM 400–1200 CFM
Cooling Capacity:
2.35–13.0 KW 2.35–13.78 KW
Heating Capacity:
3.90–22.17 KW 3.90–13.30 KW
Power Input:
36–221 W 5–552 W
Sound Pressure Level (H):
35–52 DB(A) 29–58 DB(A)
Power Supply:
220–240V / 1Ph / 50Hz
Motor Type:
Low-noise 3-speed AC DC Brushless
Highlight:

Medium Static Duct FCU

,

Concealed Quiet Duct FCU

,

Reversible Piping Duct FCU

Product Description
Product Overview

Concealed ducted fan coil units serve the spaces occupants judge most harshly — guestrooms, offices, clinics — precisely because nobody sees them until something goes wrong: a drip on the ceiling, a rattle at night, a stuffy room at the end of a long duct run. The Midea Medium Static Pressure Duct Fan Coil Unit is engineered to design those failures out. On AC models, water connections reverse from left to right on site; on DC models, external static pressure is selectable at 12, 30 or 50Pa via the PCB or wired controller. Return air draws from the rear or the bottom. Units adapt to as-built reality instead of forcing compromises that surface later as faults. One family spans 400–1200 CFM with cooling capacities from 2.35 to 13.78 kW across the AC and DC range.

At 241mm body height (261mm for DC), the chassis hides above standard ceiling grids, while three-row and four-row coil options match two-pipe or four-pipe hydraulics across the building. The enlarged drain pan option is low-cost insurance against the leak every facility manager dreads: condensation staining a finished ceiling and flooding the helpdesk with work orders. And because the filter assembly extracts in multiple directions, maintenance access works however the ceiling void ended up being built — your team services every unit quickly instead of inventing an access solution on every visit.

The DC inverter brushless range provides seven fan speeds for precise airflow balancing — rooms neither stuffy nor draughty, which means fewer comfort calls — plus up to 30% lower fan energy and native V8 controller integration for estates pairing FCUs with Midea VRF outdoor systems. XYE and PQE ports put central control and Modbus RTU within easy reach, so unit status lands on your central monitoring screen rather than on a clipboard round. Standard supply is 220–240V / 1Ph / 50Hz; for properties on other grids, Hongtai provides OEM/ODM support with custom voltages from 180–440V at 50/60Hz, project branding and protocol options.

Key Selling Points
  • Site-Reversible Water Connections (AC) — Units adapt to as-built riser positions, so installation compromises never become your maintenance problem.
  • Selectable ESP 12/30/50Pa (DC) — Airflow matched to the real ductwork at commissioning; no chronically under-ventilated rooms.
  • Rear or Bottom Return Air — Return path suits the actual void; no custom plenums to inspect and repair later.
  • Enlarged Drain Pan Option — Low-cost insurance against the ceiling-stain leaks that flood the helpdesk.
  • Seven-Speed DC Balancing — Rooms tuned precisely between stuffy and draughty; fewer comfort complaints.
  • Multi-Direction Filter Extraction — Filter access however the void was built; service visits stay short and predictable.
  • V8 Integration, XYE / PQE Ports — Native VRF pairing plus central control and Modbus RTU visibility on one screen.
  • Up To 30% Lower Fan Energy (DC) — Direct electricity savings across the concealed fleet.
  • OEM/ODM via Hongtai — Custom voltage (180–440V, 50/60Hz), branding, protocols and long-term spares support.
AC vs DC — Which Should You Specify?

The AC range is the robust default for standard duct runs where 3-speed control is adequate — and its on-site left/right piping reversal quietly prevents future maintenance headaches. Where noise ratings are written into the SLA, or energy performance is audited, choose the DC inverter brushless range: external static selectable at 12/30/50Pa via PCB or wired controller, seven-speed balancing, up to 30% fan energy saving and native V8 integration. Coil options, connections and service access are shared across both, so maintenance procedures and spares stay identical.

Applications
  1. Hotel Guestroom Ceilings — Quiet DC units above the corridor ceiling; filter service from the room side.
  2. Office Floors with Concealed Services — Hidden units preserve ceiling aesthetics; central monitoring flags issues early.
  3. Hospital and Clinic Areas — Optional filtration and low-noise DC models suit clinical duty cycles.
  4. Retail Units Behind Bulkheads — Multi-branch ducting serves sales floors from concealed positions.
  5. Apartments and Serviced Suites — Flexible connections cover varied flat layouts with one unit family.
Frequently Asked Questions
Q: Rooms at the end of long duct runs are always stuffy — can that be fixed?

A: That pattern usually means the static pressure was never matched to the ductwork. On DC models you select 12/30/50Pa at commissioning to match the as-built ducts — 50Pa handles long runs with multiple bends, so distant rooms finally receive design airflow.

Q: How do we reach the filter when the ceiling void is tight?

A: The filter assembly extracts in multiple directions, so service access works however the void was built. Your team spends minutes per unit instead of improvising access on every visit.

Q: Can these units report status to our BMS?

A: Yes. XYE and PQE ports handle central control and Modbus RTU respectively, and the range integrates natively with Midea V8 systems — so run status and faults reach your central dashboard instead of waiting for a complaint.

Q: What protects finished ceilings from condensate leaks?

A: Specify the enlarged drain pan option — low-cost insurance against the leak that stains ceilings, damages interiors and triggers emergency call-outs.

Q: What routine maintenance does a concealed unit need?

A: Regular filter cleaning plus an annual coil and drain check keeps the unit at rated performance. Multi-direction filter extraction keeps each visit short, whichever way the void was built.

Certifications & Standards
  • CE Marking — European conformity for safety and electromagnetic compatibility.
  • Eurovent Certified Performance — Third-party verified capacity and efficiency ratings.
  • ERP Compliant — Meets EU Energy-related Products Directive requirements.
  • RoHS Compliant — Restriction of Hazardous Substances directive conformance.
  • GB/T 19232 — Chinese national standard for fan coil unit performance testing.
Technical Specifications
Parameter AC Series DC Series
Airflow Range400–1200 CFM400–1200 CFM
Cooling Capacity2.35–13.0 kW2.35–13.78 kW
Heating Capacity3.90–22.17 kW3.90–13.30 kW
Power Input36–221 W5–552 W
Sound Pressure Level (H)35–52 dB(A)29–58 dB(A)
Power Supply220–240V / 1Ph / 50Hz220–240V / 1Ph / 50Hz
Body Height241 mm261 mm
External Static Pressure12/30/50 Pa (customizable)12/30/50 Pa (adjustable)
Coil Rows3 / 43 / 4
Max. Working Pressure1.6 MPa1.6 MPa
Motor TypeLow-noise 3-speed ACDC Brushless
Pipe ConnectionRC3/4"RC3/4"
AEH OptionAvailableAvailable
Pipe System2-pipe / 4-pipe2-pipe / 4-pipe
Related Search Terms

medium static duct fan coil maintenance · concealed FCU filter access · duct fan coil selectable 12/30/50Pa · quiet ducted FCU for guestrooms · fan coil BMS Modbus monitoring · duct FCU enlarged drain pan leak protection · reversible piping fan coil unit · energy efficient duct FCU 30%

Products
PRODUCTS DETAILS
Medium Static Duct FCU Concealed Quiet and Easy to Service Reversible Piping Duct FCU Fewer Surprises Behind the Ceiling
Detail Information
Place of Origin
China
Brand Name
OEM;MIDEA
Certification
CB,ISO
Product Name:
Medium Static Duct FCU
Airflow Range:
400–1200 CFM 400–1200 CFM
Cooling Capacity:
2.35–13.0 KW 2.35–13.78 KW
Heating Capacity:
3.90–22.17 KW 3.90–13.30 KW
Power Input:
36–221 W 5–552 W
Sound Pressure Level (H):
35–52 DB(A) 29–58 DB(A)
Power Supply:
220–240V / 1Ph / 50Hz
Motor Type:
Low-noise 3-speed AC DC Brushless
Highlight

Medium Static Duct FCU

,

Concealed Quiet Duct FCU

,

Reversible Piping Duct FCU

Product Description
Product Overview

Concealed ducted fan coil units serve the spaces occupants judge most harshly — guestrooms, offices, clinics — precisely because nobody sees them until something goes wrong: a drip on the ceiling, a rattle at night, a stuffy room at the end of a long duct run. The Midea Medium Static Pressure Duct Fan Coil Unit is engineered to design those failures out. On AC models, water connections reverse from left to right on site; on DC models, external static pressure is selectable at 12, 30 or 50Pa via the PCB or wired controller. Return air draws from the rear or the bottom. Units adapt to as-built reality instead of forcing compromises that surface later as faults. One family spans 400–1200 CFM with cooling capacities from 2.35 to 13.78 kW across the AC and DC range.

At 241mm body height (261mm for DC), the chassis hides above standard ceiling grids, while three-row and four-row coil options match two-pipe or four-pipe hydraulics across the building. The enlarged drain pan option is low-cost insurance against the leak every facility manager dreads: condensation staining a finished ceiling and flooding the helpdesk with work orders. And because the filter assembly extracts in multiple directions, maintenance access works however the ceiling void ended up being built — your team services every unit quickly instead of inventing an access solution on every visit.

The DC inverter brushless range provides seven fan speeds for precise airflow balancing — rooms neither stuffy nor draughty, which means fewer comfort calls — plus up to 30% lower fan energy and native V8 controller integration for estates pairing FCUs with Midea VRF outdoor systems. XYE and PQE ports put central control and Modbus RTU within easy reach, so unit status lands on your central monitoring screen rather than on a clipboard round. Standard supply is 220–240V / 1Ph / 50Hz; for properties on other grids, Hongtai provides OEM/ODM support with custom voltages from 180–440V at 50/60Hz, project branding and protocol options.

Key Selling Points
  • Site-Reversible Water Connections (AC) — Units adapt to as-built riser positions, so installation compromises never become your maintenance problem.
  • Selectable ESP 12/30/50Pa (DC) — Airflow matched to the real ductwork at commissioning; no chronically under-ventilated rooms.
  • Rear or Bottom Return Air — Return path suits the actual void; no custom plenums to inspect and repair later.
  • Enlarged Drain Pan Option — Low-cost insurance against the ceiling-stain leaks that flood the helpdesk.
  • Seven-Speed DC Balancing — Rooms tuned precisely between stuffy and draughty; fewer comfort complaints.
  • Multi-Direction Filter Extraction — Filter access however the void was built; service visits stay short and predictable.
  • V8 Integration, XYE / PQE Ports — Native VRF pairing plus central control and Modbus RTU visibility on one screen.
  • Up To 30% Lower Fan Energy (DC) — Direct electricity savings across the concealed fleet.
  • OEM/ODM via Hongtai — Custom voltage (180–440V, 50/60Hz), branding, protocols and long-term spares support.
AC vs DC — Which Should You Specify?

The AC range is the robust default for standard duct runs where 3-speed control is adequate — and its on-site left/right piping reversal quietly prevents future maintenance headaches. Where noise ratings are written into the SLA, or energy performance is audited, choose the DC inverter brushless range: external static selectable at 12/30/50Pa via PCB or wired controller, seven-speed balancing, up to 30% fan energy saving and native V8 integration. Coil options, connections and service access are shared across both, so maintenance procedures and spares stay identical.

Applications
  1. Hotel Guestroom Ceilings — Quiet DC units above the corridor ceiling; filter service from the room side.
  2. Office Floors with Concealed Services — Hidden units preserve ceiling aesthetics; central monitoring flags issues early.
  3. Hospital and Clinic Areas — Optional filtration and low-noise DC models suit clinical duty cycles.
  4. Retail Units Behind Bulkheads — Multi-branch ducting serves sales floors from concealed positions.
  5. Apartments and Serviced Suites — Flexible connections cover varied flat layouts with one unit family.
Frequently Asked Questions
Q: Rooms at the end of long duct runs are always stuffy — can that be fixed?

A: That pattern usually means the static pressure was never matched to the ductwork. On DC models you select 12/30/50Pa at commissioning to match the as-built ducts — 50Pa handles long runs with multiple bends, so distant rooms finally receive design airflow.

Q: How do we reach the filter when the ceiling void is tight?

A: The filter assembly extracts in multiple directions, so service access works however the void was built. Your team spends minutes per unit instead of improvising access on every visit.

Q: Can these units report status to our BMS?

A: Yes. XYE and PQE ports handle central control and Modbus RTU respectively, and the range integrates natively with Midea V8 systems — so run status and faults reach your central dashboard instead of waiting for a complaint.

Q: What protects finished ceilings from condensate leaks?

A: Specify the enlarged drain pan option — low-cost insurance against the leak that stains ceilings, damages interiors and triggers emergency call-outs.

Q: What routine maintenance does a concealed unit need?

A: Regular filter cleaning plus an annual coil and drain check keeps the unit at rated performance. Multi-direction filter extraction keeps each visit short, whichever way the void was built.

Certifications & Standards
  • CE Marking — European conformity for safety and electromagnetic compatibility.
  • Eurovent Certified Performance — Third-party verified capacity and efficiency ratings.
  • ERP Compliant — Meets EU Energy-related Products Directive requirements.
  • RoHS Compliant — Restriction of Hazardous Substances directive conformance.
  • GB/T 19232 — Chinese national standard for fan coil unit performance testing.
Technical Specifications
Parameter AC Series DC Series
Airflow Range400–1200 CFM400–1200 CFM
Cooling Capacity2.35–13.0 kW2.35–13.78 kW
Heating Capacity3.90–22.17 kW3.90–13.30 kW
Power Input36–221 W5–552 W
Sound Pressure Level (H)35–52 dB(A)29–58 dB(A)
Power Supply220–240V / 1Ph / 50Hz220–240V / 1Ph / 50Hz
Body Height241 mm261 mm
External Static Pressure12/30/50 Pa (customizable)12/30/50 Pa (adjustable)
Coil Rows3 / 43 / 4
Max. Working Pressure1.6 MPa1.6 MPa
Motor TypeLow-noise 3-speed ACDC Brushless
Pipe ConnectionRC3/4"RC3/4"
AEH OptionAvailableAvailable
Pipe System2-pipe / 4-pipe2-pipe / 4-pipe
Related Search Terms

medium static duct fan coil maintenance · concealed FCU filter access · duct fan coil selectable 12/30/50Pa · quiet ducted FCU for guestrooms · fan coil BMS Modbus monitoring · duct FCU enlarged drain pan leak protection · reversible piping fan coil unit · energy efficient duct FCU 30%

Sitemap |  Privacy Policy | China Good Quality DC Inverter VRF Supplier. Copyright © 2024-2026 Henan Hongtai HVAC Equipment Co., Ltd. . All Rights Reserved.