logo
Products
PRODUCTS DETAILS
Home > Products >
Midea 150Pa High Static Duct FCU Fewer Units Fewer Failure Points High Capacity 400 1800 CFM Duct FCU Shrinks the Asset Register

Midea 150Pa High Static Duct FCU Fewer Units Fewer Failure Points High Capacity 400 1800 CFM Duct FCU Shrinks the Asset Register

Detail Information
Place of Origin
China
Brand Name
OEM;MIDEA
Certification
CB,ISO
Product Name:
High Static Duct FCU
Airflow Range:
400–1800 CFM
Cooling Capacity:
6.6–19.9 KW
Heating Capacity:
9.7–30.0 KW
Power Input:
285–950 W
Sound Pressure Level (H):
49–61 DB(A)
Power Supply:
220–240V / 1Ph / 50Hz
Motor Type:
Low-noise 3-speed AC
Highlight:

Midea 150Pa High Static Duct FCU

,

400-1800 CFM Duct FCU

,

Fewer Failure Points Duct FCU

Product Description
Product Overview: High Static Pressure Duct Fan Coil Unit

Every fan coil on your asset register is a recurring cost line: a filter to clean, a drain pan to check, a motor that will one day need attention, a control node to keep online. The Midea High Static Pressure Duct Fan Coil Unit shrinks that register directly — 150Pa of external static pressure drives conditioned air through long, complex duct networks, so a single 400–1800 CFM unit delivering 6.6–19.9 kW of cooling covers floor areas that would otherwise need two or three smaller machines. Fewer units means fewer filters, fewer drain points, fewer motors and fewer control nodes — and the planned maintenance schedule shortens in proportion, year after year.

Leak risk concentrates where equipment count concentrates, which is why the drainage design matters as much as the airflow. The dual-seal drain pan with standard extended pan provides layered protection against the leak that damages finished interiors, closes a sales floor or ward, and fills your week with emergency work orders. The four-speed motor's super-high boost tier delivers fast pull-down on demand — essential for venues that run on event schedules, where conditioning an empty hall all day is money straight out of the operations budget. When service time comes, the single-screw filter release gives tool-free access in minutes per unit, keeping PPM visits short across a large estate.

Water connections reverse left or right to match riser positions without re-piping — a detail that also future-proofs the asset against plant-room changes. Configurable electric auxiliary heating from 5000–9500W covers supplementary or peak heating loads without oversizing the base unit. BMS and Modbus integration comes via the FCU KIT, bringing run status and fault alerts for the whole fleet onto one central screen. Standard supply is 220–240V / 1Ph / 50Hz, with OEM/ODM custom voltage (180–440V, 50/60Hz) and branding support available through Hongtai for export projects.

Key Selling Points
  • 150Pa External Static PressureOne unit serves areas that would otherwise take two or three — fewer assets to maintain.
  • 400–1800 CFM High CapacityA shorter asset register: fewer filters, drain points, motors and control nodes.
  • Dual-Seal Drain Pan SystemLayered leak protection for finished interiors and your helpdesk.
  • Standard Extended Drain PanCondensate protection built in from day one; no aftermarket add-ons to manage.
  • Four-Speed Motor with Super-High BoostFast pull-down for event-driven venues; avoids wasteful all-day runtime.
  • Single-Screw Filter ReleaseTool-free access keeps PPM visits to minutes per unit.
  • Reversible Water ConnectionsFuture riser or plant-room changes do not strand the asset.
  • Configurable AEH 5000–9500WSupplementary heating matched to load; no oversized base units wasting energy.
  • BMS / Modbus via FCU KITWhole-fleet status and fault alerts on one central monitoring screen.
Sizing & Selection Notes

Start with the asset register, not the room count. Where duct runs are long, branched or heavily bent, specify the 150Pa class from the outset — undersized static surfaces years later as chronic under-ventilation complaints that no amount of maintenance can fix. Then consolidate: with 6.6–19.9 kW per unit, one machine typically replaces two or three smaller FCUs on open floor plates, cutting filters, drain points and control nodes from your PPM schedule in one move. Finally, size auxiliary electric heating from the 5000–9500W option band to the actual winter load rather than oversizing the base unit. Hongtai's technical team can check selections against your drawings before procurement commits.

Applications
  1. Shopping Malls and Department Stores — Fewer high-capacity units simplify maintenance across large retail floor plates.
  2. Airport and Rail Terminals — 150Pa static pressure overcomes complex routing in high-ceiling public concourses.
  3. Exhibition and Convention Halls — Boost mode matches event schedules instead of conditioning empty space all day.
  4. Large Open-Plan Offices — Consolidated equipment count reduces plant space and planned maintenance workload.
  5. Hospital Inpatient Floors — Ducted delivery with optional filtration meets clinical standards at manageable unit counts.
Frequently Asked Questions
Q: Our mall has chronically stuffy zones at the ends of long duct runs — will this fix them?

A: That pattern almost always points to undersized static pressure. At 150Pa, one unit pushes design airflow through long, branched networks that starve standard 12–50Pa models — reaching the zones your current fleet cannot serve properly.

Q: How does a high-static unit reduce our maintenance workload?

A: Arithmetic. One 400–1800 CFM unit routinely replaces two or three smaller FCUs per zone, so filters, drain points, motors and control nodes drop in proportion — and every future PPM visit covers more floor area per stop.

Q: What protects finished interiors from condensate leaks?

A: A dual-seal drain pan plus a standard extended pan — layered protection engineered to prevent the leak that closes a sales floor, damages a fit-out and dominates your work-order queue for a week.

Q: Can we see unit status centrally?

A: Yes. BMS and Modbus integration via the FCU KIT brings run status and fault alerts onto your central monitoring screen, so problems surface before occupants report them.

Q: Is there a DC motor version of this range?

A: This high-static range uses a robust AC four-speed motor with a super-high boost tier for fast pull-down. Where DC efficiency is the priority on standard duct runs, the Medium Static Pressure DC range offers seven-speed brushless control.

Certifications & Standards
  • CE Marking — European conformity for safety and electromagnetic compatibility.
  • Eurovent Certified Performance — Third-party verified capacity and efficiency ratings.
  • ERP Compliant — Meets EU Energy-related Products Directive requirements.
  • RoHS Compliant — Restriction of Hazardous Substances directive conformance.
  • GB/T 19232 — Chinese national standard for fan coil unit performance testing.
Technical Specifications
Parameter Specification
Airflow Range400–1800 CFM
Cooling Capacity6.6–19.9 kW
Heating Capacity9.7–30.0 kW
Power Input285–950 W
Sound Pressure Level (H)49–61 dB(A)
Power Supply220–240V / 1Ph / 50Hz
External Static Pressure150 Pa
Body Height400 mm
Coil Rows2–3
Max. Working Pressure1.6 MPa
Motor TypeLow-noise 3-speed AC
Pipe ConnectionRC3/4"
Drain ConnectionZG5/4"
AEH Option5000–9500 W
Pipe System2-pipe
Product Gallery
Related Search Terms
  • high static pressure duct fan coil 150Pa
  • large area fan coil fewer units
  • mall air conditioning maintenance cost
  • duct FCU dual seal drain pan
  • high capacity ducted FCU 1800 CFM
  • fan coil BMS central monitoring
  • exhibition hall FCU fast pull-down
  • commercial fan coil lifecycle cost
Products
PRODUCTS DETAILS
Midea 150Pa High Static Duct FCU Fewer Units Fewer Failure Points High Capacity 400 1800 CFM Duct FCU Shrinks the Asset Register
Detail Information
Place of Origin
China
Brand Name
OEM;MIDEA
Certification
CB,ISO
Product Name:
High Static Duct FCU
Airflow Range:
400–1800 CFM
Cooling Capacity:
6.6–19.9 KW
Heating Capacity:
9.7–30.0 KW
Power Input:
285–950 W
Sound Pressure Level (H):
49–61 DB(A)
Power Supply:
220–240V / 1Ph / 50Hz
Motor Type:
Low-noise 3-speed AC
Highlight

Midea 150Pa High Static Duct FCU

,

400-1800 CFM Duct FCU

,

Fewer Failure Points Duct FCU

Product Description
Product Overview: High Static Pressure Duct Fan Coil Unit

Every fan coil on your asset register is a recurring cost line: a filter to clean, a drain pan to check, a motor that will one day need attention, a control node to keep online. The Midea High Static Pressure Duct Fan Coil Unit shrinks that register directly — 150Pa of external static pressure drives conditioned air through long, complex duct networks, so a single 400–1800 CFM unit delivering 6.6–19.9 kW of cooling covers floor areas that would otherwise need two or three smaller machines. Fewer units means fewer filters, fewer drain points, fewer motors and fewer control nodes — and the planned maintenance schedule shortens in proportion, year after year.

Leak risk concentrates where equipment count concentrates, which is why the drainage design matters as much as the airflow. The dual-seal drain pan with standard extended pan provides layered protection against the leak that damages finished interiors, closes a sales floor or ward, and fills your week with emergency work orders. The four-speed motor's super-high boost tier delivers fast pull-down on demand — essential for venues that run on event schedules, where conditioning an empty hall all day is money straight out of the operations budget. When service time comes, the single-screw filter release gives tool-free access in minutes per unit, keeping PPM visits short across a large estate.

Water connections reverse left or right to match riser positions without re-piping — a detail that also future-proofs the asset against plant-room changes. Configurable electric auxiliary heating from 5000–9500W covers supplementary or peak heating loads without oversizing the base unit. BMS and Modbus integration comes via the FCU KIT, bringing run status and fault alerts for the whole fleet onto one central screen. Standard supply is 220–240V / 1Ph / 50Hz, with OEM/ODM custom voltage (180–440V, 50/60Hz) and branding support available through Hongtai for export projects.

Key Selling Points
  • 150Pa External Static PressureOne unit serves areas that would otherwise take two or three — fewer assets to maintain.
  • 400–1800 CFM High CapacityA shorter asset register: fewer filters, drain points, motors and control nodes.
  • Dual-Seal Drain Pan SystemLayered leak protection for finished interiors and your helpdesk.
  • Standard Extended Drain PanCondensate protection built in from day one; no aftermarket add-ons to manage.
  • Four-Speed Motor with Super-High BoostFast pull-down for event-driven venues; avoids wasteful all-day runtime.
  • Single-Screw Filter ReleaseTool-free access keeps PPM visits to minutes per unit.
  • Reversible Water ConnectionsFuture riser or plant-room changes do not strand the asset.
  • Configurable AEH 5000–9500WSupplementary heating matched to load; no oversized base units wasting energy.
  • BMS / Modbus via FCU KITWhole-fleet status and fault alerts on one central monitoring screen.
Sizing & Selection Notes

Start with the asset register, not the room count. Where duct runs are long, branched or heavily bent, specify the 150Pa class from the outset — undersized static surfaces years later as chronic under-ventilation complaints that no amount of maintenance can fix. Then consolidate: with 6.6–19.9 kW per unit, one machine typically replaces two or three smaller FCUs on open floor plates, cutting filters, drain points and control nodes from your PPM schedule in one move. Finally, size auxiliary electric heating from the 5000–9500W option band to the actual winter load rather than oversizing the base unit. Hongtai's technical team can check selections against your drawings before procurement commits.

Applications
  1. Shopping Malls and Department Stores — Fewer high-capacity units simplify maintenance across large retail floor plates.
  2. Airport and Rail Terminals — 150Pa static pressure overcomes complex routing in high-ceiling public concourses.
  3. Exhibition and Convention Halls — Boost mode matches event schedules instead of conditioning empty space all day.
  4. Large Open-Plan Offices — Consolidated equipment count reduces plant space and planned maintenance workload.
  5. Hospital Inpatient Floors — Ducted delivery with optional filtration meets clinical standards at manageable unit counts.
Frequently Asked Questions
Q: Our mall has chronically stuffy zones at the ends of long duct runs — will this fix them?

A: That pattern almost always points to undersized static pressure. At 150Pa, one unit pushes design airflow through long, branched networks that starve standard 12–50Pa models — reaching the zones your current fleet cannot serve properly.

Q: How does a high-static unit reduce our maintenance workload?

A: Arithmetic. One 400–1800 CFM unit routinely replaces two or three smaller FCUs per zone, so filters, drain points, motors and control nodes drop in proportion — and every future PPM visit covers more floor area per stop.

Q: What protects finished interiors from condensate leaks?

A: A dual-seal drain pan plus a standard extended pan — layered protection engineered to prevent the leak that closes a sales floor, damages a fit-out and dominates your work-order queue for a week.

Q: Can we see unit status centrally?

A: Yes. BMS and Modbus integration via the FCU KIT brings run status and fault alerts onto your central monitoring screen, so problems surface before occupants report them.

Q: Is there a DC motor version of this range?

A: This high-static range uses a robust AC four-speed motor with a super-high boost tier for fast pull-down. Where DC efficiency is the priority on standard duct runs, the Medium Static Pressure DC range offers seven-speed brushless control.

Certifications & Standards
  • CE Marking — European conformity for safety and electromagnetic compatibility.
  • Eurovent Certified Performance — Third-party verified capacity and efficiency ratings.
  • ERP Compliant — Meets EU Energy-related Products Directive requirements.
  • RoHS Compliant — Restriction of Hazardous Substances directive conformance.
  • GB/T 19232 — Chinese national standard for fan coil unit performance testing.
Technical Specifications
Parameter Specification
Airflow Range400–1800 CFM
Cooling Capacity6.6–19.9 kW
Heating Capacity9.7–30.0 kW
Power Input285–950 W
Sound Pressure Level (H)49–61 dB(A)
Power Supply220–240V / 1Ph / 50Hz
External Static Pressure150 Pa
Body Height400 mm
Coil Rows2–3
Max. Working Pressure1.6 MPa
Motor TypeLow-noise 3-speed AC
Pipe ConnectionRC3/4"
Drain ConnectionZG5/4"
AEH Option5000–9500 W
Pipe System2-pipe
Product Gallery
Related Search Terms
  • high static pressure duct fan coil 150Pa
  • large area fan coil fewer units
  • mall air conditioning maintenance cost
  • duct FCU dual seal drain pan
  • high capacity ducted FCU 1800 CFM
  • fan coil BMS central monitoring
  • exhibition hall FCU fast pull-down
  • commercial fan coil lifecycle cost
Sitemap |  Privacy Policy | China Good Quality DC Inverter VRF Supplier. Copyright © 2024-2026 Henan Hongtai HVAC Equipment Co., Ltd. . All Rights Reserved.