Midea Wall FCU Left Right or Rear Piping 0 10V BMS Input 10W Low Speed 27 dB Quiet

Midea Wall FCU Left Right or Rear Piping 0 10V BMS Input 10W Low Speed 27 dB Quiet

Detail Information
Place of Origin
China
Brand Name
OEM;MIDEA
Certification
CB,ISO
Product Name:
Wall FCU
Airflow Range:
300–600 CFM 300–600 CFM
Cooling Capacity:
1.94–4.61 KW 2.70–4.87 KW
Heating Capacity:
2.34–4.55 KW 2.94–6.31 KW
Power Input:
31–72 W 10–38 W
Sound Pressure Level (H):
30–40 DB(A) 27–44 DB(A)
Power Supply:
220–240V / 1Ph / 50Hz
Motor Type:
Low-noise 3-speed AC
Highlight:

Midea FCU 0-10V BMS input

,

FCU left right rear piping

,

10W low speed 27 dB FCU

Product Description
Product Overview

Some buildings cannot accommodate a concealed terminal at all: heritage conversions, mid-rise walk-ups, budget hotels and school blocks built without suspended ceilings. A wall mounted fan coil is the only viable option in those cases, and it is usually specified late, under pressure, and without the coordination attention the rest of the system received. The Midea Wall Mounted Fan Coil Unit is designed to be specified properly in that situation — left, right or rear water connections match wherever the existing risers actually run, the unit mounts directly to the wall with no ceiling interface, and the family covers 300–600 CFM and 1.94–4.87 kW of cooling across the combined AC and DC range, with Eurovent-certified performance behind the selection.

The internal design is aimed at the criteria a design engineer is asked to defend: a cross-flow fan and two-row coil in a body that mounts without penetrating the ceiling membrane, G1/2"–G3/4" connections and a 1.6 MPa maximum working pressure inside normal practice, and sound pressure from 30 dB(A) on AC and from 27 dB(A) on DC — the band that makes a guestroom or consulting room submission credible. The oscillating louver addresses draught complaints at the design stage rather than after handover, the display shutoff keeps sleeping areas dark, and the front panel removes without tools so the maintenance strategy does not depend on a specialist visit.

Controls are where this unit is most often underestimated: 0–10V input and output is built in for direct integration with a building management system, which suits a schedule written around analogue modulation, and Hongtai supports OEM/ODM control protocols including Modbus RTU and BACnet where the specification calls for them. The DC inverter brushless version draws 10W at low speed and reduces fan energy by up to 30%, with seven speeds through the KJR-75A controller for room-by-room balance. Two panel designs, A Type and P Type, allow the interior finish to be resolved without changing the terminal unit behind it, and all models run on 220–240V / 1Ph / 50Hz.

Key Selling Points
  • No Ceiling Interface — The terminal mounts directly to the wall, so buildings without suspended ceilings can be served without altering the structure or the finishes.
  • Left, Right or Rear Piping — Three pipe orientations within one unit, so the riser position does not dictate the equipment selection.
  • 0–10V Input and Output as Standard — Direct analogue integration with a building management system, with Modbus RTU and BACnet available through Hongtai for protocol-based schedules.
  • From 27 dB(A) on the DC Tier — Supports guestroom, consulting room and classroom acoustic criteria without secondary attenuation.
  • 10W at Low Speed (DC) — Up to 30% lower fan energy, which matters where rooms run continuously.
  • Cross-Flow Fan with Two-Row Coil — Even discharge across the room face with a coil depth that suits standard chilled and low-temperature hot water.
  • A Type / P Type Panels — The interior finish is resolved without a change to the terminal unit, the connections or the schedule.
  • Tool-Free Front Access — Filter service is a short visit rather than a maintenance event, which protects the O&M strategy.
  • AEH Option 750–900 W (AC) — Electric auxiliary heating where the heating source is not water-based.
AC vs DC — Which Should You Specify?

Where rooms are occupied for a few hours a day and the schedule is capital-cost driven, the AC three-speed version meets the duty with the simplest control interface. Where the space runs continuously — guestrooms, serviced apartments, dormitories — the DC inverter brushless version is the better case: 10W at low speed, up to 30% lower fan energy and 27 dB(A) at the quiet end, all with the same wall-mounting method, the same three piping directions and the same panel options. Because the mounting and hydraulic interfaces are identical, the motor decision can be taken at tender stage without revisiting the wall and riser coordination.

Applications
  1. Heritage and Conversion Projects — Comfort delivered where ceiling alteration is restricted by structure, consent or listing.
  2. Budget Hotels and Serviced Apartments — Fast installation and low DC running cost suit thin-margin hospitality operation.
  3. Residential Walk-Ups and Mid-Rise Blocks — Surface mounting serves apartments with no suspended ceiling provision.
  4. Classrooms and Dormitories — Robust, low-maintenance terminals for institutional occupancy patterns.
  5. Clinics and Consulting Rooms — Wall mounting avoids penetrating ceiling membranes in clinical and diagnostic spaces.
Frequently Asked Questions
Q: How does 0–10V integration compare with a Modbus or BACnet schedule?

A: 0–10V input and output is integral to the unit and suits a controls specification written around analogue modulation of the terminal. Where the schedule requires a digital protocol, Hongtai supports OEM/ODM configurations including Modbus RTU and BACnet, so the point of integration can be stated explicitly in the specification rather than resolved on site.

Q: What wall construction and clearances should the specification require?

A: The unit is a surface-mounted item, so the specification should require a structural or suitably framed wall capable of carrying the unit and its connections, with the service and air-path clearances given in the installation manual. Because there is no ceiling interface, the ceiling zone can be released for other services.

Q: Is electric heating available across the whole range?

A: The electric auxiliary heating option of 750–900W applies to the AC models; the DC range is specified without it. Where a heating requirement exists in a room served by the DC tier, it should be met from the water circuit and the coil duty checked accordingly.

Q: Can the DC tier meet a guestroom acoustic criterion?

A: The DC range starts at 27 dB(A), which is normally acceptable for guestrooms and consulting rooms when the unit is sized so that the design duty sits below maximum speed. Sound pressure figures should be quoted at the operating speed assumed in the design, not at the minimum.

Q: When should the A Type or P Type panel be selected?

A: The panel is a finish decision taken with the interior designer; both mount on the same terminal unit and do not change capacity, connections or controls. Selecting the panel late does not reopen the equipment order, which is useful where the interior package is procured separately.

Certifications & Standards
  • CE Marking — European conformity for safety and electromagnetic compatibility.
  • Eurovent Certified Performance — Third-party verified capacity and efficiency ratings.
  • ERP Compliant — Meets EU Energy-related Products Directive requirements.
  • RoHS Compliant — Restriction of Hazardous Substances directive conformance.
  • GB/T 19232 — Chinese national standard for fan coil unit performance testing.
Technical Specifications
Parameter AC Series DC Series
Airflow Range300–600 CFM300–600 CFM
Cooling Capacity1.94–4.61 kW2.70–4.87 kW
Heating Capacity2.34–4.55 kW2.94–6.31 kW
Power Input31–72 W10–38 W
Sound Pressure Level (H)30–40 dB(A)27–44 dB(A)
Power Supply220–240V / 1Ph / 50Hz220–240V / 1Ph / 50Hz
Fan TypeCross-flow fanCross-flow fan
Coil Rows22
Max. Working Pressure1.6 MPa1.6 MPa
Motor TypeLow-noise 3-speed ACDC Brushless
Pipe ConnectionG1/2"–G3/4"G1/2"–G3/4"
AEH Option750–900 W—
Panel OptionsA Type / P TypeA Type / P Type
Related Search Terms

wall mounted fan coil unit specification · surface mounted FCU no ceiling · wall FCU 0–10V BMS · retrofit fan coil left right rear piping · quiet wall fan coil for hotel room · Eurovent certified wall FCU · DC wall mounted fan coil 10W · fan coil for heritage building

Products
PRODUCTS DETAILS
Midea Wall FCU Left Right or Rear Piping 0 10V BMS Input 10W Low Speed 27 dB Quiet
Detail Information
Place of Origin
China
Brand Name
OEM;MIDEA
Certification
CB,ISO
Product Name:
Wall FCU
Airflow Range:
300–600 CFM 300–600 CFM
Cooling Capacity:
1.94–4.61 KW 2.70–4.87 KW
Heating Capacity:
2.34–4.55 KW 2.94–6.31 KW
Power Input:
31–72 W 10–38 W
Sound Pressure Level (H):
30–40 DB(A) 27–44 DB(A)
Power Supply:
220–240V / 1Ph / 50Hz
Motor Type:
Low-noise 3-speed AC
Highlight

Midea FCU 0-10V BMS input

,

FCU left right rear piping

,

10W low speed 27 dB FCU

Product Description
Product Overview

Some buildings cannot accommodate a concealed terminal at all: heritage conversions, mid-rise walk-ups, budget hotels and school blocks built without suspended ceilings. A wall mounted fan coil is the only viable option in those cases, and it is usually specified late, under pressure, and without the coordination attention the rest of the system received. The Midea Wall Mounted Fan Coil Unit is designed to be specified properly in that situation — left, right or rear water connections match wherever the existing risers actually run, the unit mounts directly to the wall with no ceiling interface, and the family covers 300–600 CFM and 1.94–4.87 kW of cooling across the combined AC and DC range, with Eurovent-certified performance behind the selection.

The internal design is aimed at the criteria a design engineer is asked to defend: a cross-flow fan and two-row coil in a body that mounts without penetrating the ceiling membrane, G1/2"–G3/4" connections and a 1.6 MPa maximum working pressure inside normal practice, and sound pressure from 30 dB(A) on AC and from 27 dB(A) on DC — the band that makes a guestroom or consulting room submission credible. The oscillating louver addresses draught complaints at the design stage rather than after handover, the display shutoff keeps sleeping areas dark, and the front panel removes without tools so the maintenance strategy does not depend on a specialist visit.

Controls are where this unit is most often underestimated: 0–10V input and output is built in for direct integration with a building management system, which suits a schedule written around analogue modulation, and Hongtai supports OEM/ODM control protocols including Modbus RTU and BACnet where the specification calls for them. The DC inverter brushless version draws 10W at low speed and reduces fan energy by up to 30%, with seven speeds through the KJR-75A controller for room-by-room balance. Two panel designs, A Type and P Type, allow the interior finish to be resolved without changing the terminal unit behind it, and all models run on 220–240V / 1Ph / 50Hz.

Key Selling Points
  • No Ceiling Interface — The terminal mounts directly to the wall, so buildings without suspended ceilings can be served without altering the structure or the finishes.
  • Left, Right or Rear Piping — Three pipe orientations within one unit, so the riser position does not dictate the equipment selection.
  • 0–10V Input and Output as Standard — Direct analogue integration with a building management system, with Modbus RTU and BACnet available through Hongtai for protocol-based schedules.
  • From 27 dB(A) on the DC Tier — Supports guestroom, consulting room and classroom acoustic criteria without secondary attenuation.
  • 10W at Low Speed (DC) — Up to 30% lower fan energy, which matters where rooms run continuously.
  • Cross-Flow Fan with Two-Row Coil — Even discharge across the room face with a coil depth that suits standard chilled and low-temperature hot water.
  • A Type / P Type Panels — The interior finish is resolved without a change to the terminal unit, the connections or the schedule.
  • Tool-Free Front Access — Filter service is a short visit rather than a maintenance event, which protects the O&M strategy.
  • AEH Option 750–900 W (AC) — Electric auxiliary heating where the heating source is not water-based.
AC vs DC — Which Should You Specify?

Where rooms are occupied for a few hours a day and the schedule is capital-cost driven, the AC three-speed version meets the duty with the simplest control interface. Where the space runs continuously — guestrooms, serviced apartments, dormitories — the DC inverter brushless version is the better case: 10W at low speed, up to 30% lower fan energy and 27 dB(A) at the quiet end, all with the same wall-mounting method, the same three piping directions and the same panel options. Because the mounting and hydraulic interfaces are identical, the motor decision can be taken at tender stage without revisiting the wall and riser coordination.

Applications
  1. Heritage and Conversion Projects — Comfort delivered where ceiling alteration is restricted by structure, consent or listing.
  2. Budget Hotels and Serviced Apartments — Fast installation and low DC running cost suit thin-margin hospitality operation.
  3. Residential Walk-Ups and Mid-Rise Blocks — Surface mounting serves apartments with no suspended ceiling provision.
  4. Classrooms and Dormitories — Robust, low-maintenance terminals for institutional occupancy patterns.
  5. Clinics and Consulting Rooms — Wall mounting avoids penetrating ceiling membranes in clinical and diagnostic spaces.
Frequently Asked Questions
Q: How does 0–10V integration compare with a Modbus or BACnet schedule?

A: 0–10V input and output is integral to the unit and suits a controls specification written around analogue modulation of the terminal. Where the schedule requires a digital protocol, Hongtai supports OEM/ODM configurations including Modbus RTU and BACnet, so the point of integration can be stated explicitly in the specification rather than resolved on site.

Q: What wall construction and clearances should the specification require?

A: The unit is a surface-mounted item, so the specification should require a structural or suitably framed wall capable of carrying the unit and its connections, with the service and air-path clearances given in the installation manual. Because there is no ceiling interface, the ceiling zone can be released for other services.

Q: Is electric heating available across the whole range?

A: The electric auxiliary heating option of 750–900W applies to the AC models; the DC range is specified without it. Where a heating requirement exists in a room served by the DC tier, it should be met from the water circuit and the coil duty checked accordingly.

Q: Can the DC tier meet a guestroom acoustic criterion?

A: The DC range starts at 27 dB(A), which is normally acceptable for guestrooms and consulting rooms when the unit is sized so that the design duty sits below maximum speed. Sound pressure figures should be quoted at the operating speed assumed in the design, not at the minimum.

Q: When should the A Type or P Type panel be selected?

A: The panel is a finish decision taken with the interior designer; both mount on the same terminal unit and do not change capacity, connections or controls. Selecting the panel late does not reopen the equipment order, which is useful where the interior package is procured separately.

Certifications & Standards
  • CE Marking — European conformity for safety and electromagnetic compatibility.
  • Eurovent Certified Performance — Third-party verified capacity and efficiency ratings.
  • ERP Compliant — Meets EU Energy-related Products Directive requirements.
  • RoHS Compliant — Restriction of Hazardous Substances directive conformance.
  • GB/T 19232 — Chinese national standard for fan coil unit performance testing.
Technical Specifications
Parameter AC Series DC Series
Airflow Range300–600 CFM300–600 CFM
Cooling Capacity1.94–4.61 kW2.70–4.87 kW
Heating Capacity2.34–4.55 kW2.94–6.31 kW
Power Input31–72 W10–38 W
Sound Pressure Level (H)30–40 dB(A)27–44 dB(A)
Power Supply220–240V / 1Ph / 50Hz220–240V / 1Ph / 50Hz
Fan TypeCross-flow fanCross-flow fan
Coil Rows22
Max. Working Pressure1.6 MPa1.6 MPa
Motor TypeLow-noise 3-speed ACDC Brushless
Pipe ConnectionG1/2"–G3/4"G1/2"–G3/4"
AEH Option750–900 W—
Panel OptionsA Type / P TypeA Type / P Type
Related Search Terms

wall mounted fan coil unit specification · surface mounted FCU no ceiling · wall FCU 0–10V BMS · retrofit fan coil left right rear piping · quiet wall fan coil for hotel room · Eurovent certified wall FCU · DC wall mounted fan coil 10W · fan coil for heritage building