logo
Products
PRODUCTS DETAILS
Home > Products >
One Way Cassette FCU Project Supply 153mm Slim for Corridors DC One Way Cassette FCU for Tenders 30 Lower Fan Energy Cost

One Way Cassette FCU Project Supply 153mm Slim for Corridors DC One Way Cassette FCU for Tenders 30 Lower Fan Energy Cost

Detail Information
Place of Origin
China
Brand Name
OEM;MIDEA
Certification
CB,ISO
Product Name:
One Way Cassette FCU
Airflow Range:
300–400 CFM 300–600 CFM
Cooling Capacity:
3.04–3.79 KW 2.65–5.20 KW
Heating Capacity:
5.13–6.41 KW 3.15–5.75 KW
Power Input:
32–40 W 14–38 W
Sound Pressure Level (H):
36–37 DB(A) 33.5–44.6 DB(A)
Power Supply:
220–240V / 1Ph / 50Hz
Motor Type:
Low-noise 3-speed AC DC Brushless
Highlight:

slim one way cassette FCU

,

DC one way cassette FCU

,

low fan energy FCU

Product Description
Product Overview: One-Way Cassette FCU for Corridor Project Supply

Corridor zones appear on every floor of the bill of quantities, and they punish fragmented buying: different units for hallways, lobbies and entryways mean more suppliers, more SKUs and more spare-parts categories to manage for the life of the building. The Midea One-way Cassette Fan Coil Unit consolidates all of it into one family. A 153mm chassis slides into the narrow ceiling voids above corridors, lobbies and room entryways where standard cassettes simply do not fit, and the single-direction discharge throws conditioned air along the hallway instead of fighting the walls. With cooling capacities from 2.65 to 5.20 kW across the combined AC and DC range, one product family covers hotel corridors, office hallways, apartment foyers and retail perimeters — one supplier, one purchase order, one documentation set.

The built-in 750mm condensate pump is a procurement detail as much as an engineering one: no external pumps to source, no condensate accessories line item, and no water-damage rectification budget after handover. Units connect to a standard 220-240V / 1Ph / 50Hz circuit, and both motor tiers share the same body dimensions and G1/2" pipe connections — so AC and DC models are interchangeable on the schedule, and the spare-parts list stays short for the maintenance contractor who inherits the building.

Choose the DC version — a DC inverter brushless motor with seven fan speeds via the KJR-75A wired controller — and the units you hand over draw as little as 14W, cut fan energy by up to 30% and run 2-5 dB(A) quieter than the AC equivalent: the lifecycle-cost argument that gets owner sign-off on a modest premium. Power-off memory restores settings after outages, the washable filter pulls out from below in seconds, and the certification set — CE, Eurovent, ERP, RoHS, GB/T 19232 — is assembled for first-pass tender review. Hongtai backs every project with OEM/ODM support — custom voltages from 180-440V at 50/60Hz, project branding, Modbus RTU and BACnet protocols — plus dependable spare-parts supply long after handover.

Key Selling Points
  • One Family Covers Every Corridor Zone — AC 300-400 / DC 300-600 CFM and 2.65-5.20 kW span hallways, lobbies and perimeters from a single line on the purchase order.
  • 153mm Ultra-Slim Body — Fits narrow corridor ceiling voids; fewer design-driven re-procurement loops when drawings meet reality.
  • Built-In 750mm Drain Pump — No external pumps or condensate accessories to source; the leak-risk rectification budget disappears.
  • AC/DC Mix in One Purchase Order — Match the project budget structure: AC where capital cost rules, DC where lifecycle cost is evaluated.
  • Lifecycle Savings Built In (DC) — From 14W draw, up to 30% lower fan energy and 2-5 dB(A) quieter operation; an efficiency story owners approve.
  • Tender-Ready Certification Set — CE, Eurovent, ERP, RoHS and GB/T 19232 documentation passes consultant review the first time.
  • Shared Spares Across the Range — Same body, same G1/2" connections, same filters; a shorter spare-parts list for the maintenance phase.
  • OEM/ODM Project Support via Hongtai — Custom voltage (180-440V, 50/60Hz), branding and BMS protocols; one supplier from quotation to handover.
AC vs DC — Which Should You Specify?

For budget-led packages where 3-speed control meets the specification, the AC version holds the initial procurement cost down and keeps spares universal across the job. Where the owner's evaluation weighs running cost — hotel corridors and residential work especially — the DC inverter brushless version earns its premium: seven speeds for precise balancing at commissioning, up to 30% lower fan energy, and 2-5 dB(A) quieter operation. Both share the same 153mm body, 750mm pump and G1/2" connections, so you can mix motor tiers across zones within one order without multiplying SKUs or spares.

Applications
  1. Hotel Corridor Packages — Slim bodies run the full length of guestroom corridors; quiet DC models protect guest sleep quality and brand standards.
  2. Office Hallways and Lift Lobbies — Directional airflow conditions circulation zones efficiently without oversized capacity.
  3. Apartment Entry Halls — Compact profile preserves ceiling height in residential corridors, foyers and lift approaches.
  4. Retail Perimeter Zones — Single-direction discharge sweeps along shopfronts and display glazing without dead spots.
  5. Hospital Ward Corridors — Low-noise DC operation and tool-free filter service suit healthcare maintenance regimes.
Frequently Asked Questions
Q: Can this one series cover every corridor zone across the whole project?

A: Yes. With AC 300-400 CFM and DC 300-600 CFM tiers delivering 2.65-5.20 kW of cooling, the family covers hotel corridors, office hallways, apartment foyers and retail perimeters — consolidating what is usually several suppliers into one purchase order and one documentation set.

Q: Is the certification documentation complete enough for tender submission?

A: The range carries CE Marking, Eurovent Certified Performance, ERP and RoHS compliance, and GB/T 19232 national-standard testing — the document set consultants and design institutes routinely require, ready for first-pass review.

Q: Do AC and DC versions share spare parts?

A: They share the same 153mm body, the same 750mm drain pump and the same G1/2" pipe connections, so the spare-parts list for the maintenance phase stays short even when a project mixes both motor tiers.

Q: What power supply do the units need, and what about export grids?

A: Standard supply is 220-240V / 1Ph / 50Hz. For projects on other grids, Hongtai supports OEM/ODM custom voltages from 180-440V at 50/60Hz under the same project supply arrangement.

Q: Does the condensate pump need to be purchased separately?

A: No. A 750mm-lift drain pump is built in as standard on every unit — there is no separate pump line item, no accessory sourcing, and no compatibility risk between components.

Certifications & Standards
  • CE Marking — European conformity for safety and electromagnetic compatibility.
  • Eurovent Certified Performance — Third-party verified capacity and efficiency ratings.
  • ERP Compliant — Meets EU Energy-related Products Directive requirements.
  • RoHS Compliant — Restriction of Hazardous Substances directive conformance.
  • GB/T 19232 — Chinese national standard for fan coil unit performance testing.
Technical Specifications
Parameter AC Series DC Series
Airflow Range300-400 CFM300-600 CFM
Cooling Capacity3.04-3.79 kW2.65-5.20 kW
Heating Capacity5.13-6.41 kW3.15-5.75 kW
Power Input32-40 W14-38 W
Sound Pressure Level (H)36-37 dB(A)33.5-44.6 dB(A)
Power Supply220-240V / 1Ph / 50Hz220-240V / 1Ph / 50Hz
Drain Pump Head750 mm750 mm
Body Height153 mm153 mm
Coil Rows22
Max. Working Pressure1.6 MPa1.6 MPa
Motor TypeLow-noise 3-speed ACDC Brushless
Pipe ConnectionG1/2"G1/2"
Product Gallery
Related Search Terms

one way cassette FCU bulk purchase corridor fan coil unit project supply fan coil tender specification 153mm slim cassette FCU quotation fan coil unit lifecycle cost cassette FCU CE Eurovent certified hotel corridor FCU procurement OEM fan coil unit supplier

Products
PRODUCTS DETAILS
One Way Cassette FCU Project Supply 153mm Slim for Corridors DC One Way Cassette FCU for Tenders 30 Lower Fan Energy Cost
Detail Information
Place of Origin
China
Brand Name
OEM;MIDEA
Certification
CB,ISO
Product Name:
One Way Cassette FCU
Airflow Range:
300–400 CFM 300–600 CFM
Cooling Capacity:
3.04–3.79 KW 2.65–5.20 KW
Heating Capacity:
5.13–6.41 KW 3.15–5.75 KW
Power Input:
32–40 W 14–38 W
Sound Pressure Level (H):
36–37 DB(A) 33.5–44.6 DB(A)
Power Supply:
220–240V / 1Ph / 50Hz
Motor Type:
Low-noise 3-speed AC DC Brushless
Highlight

slim one way cassette FCU

,

DC one way cassette FCU

,

low fan energy FCU

Product Description
Product Overview: One-Way Cassette FCU for Corridor Project Supply

Corridor zones appear on every floor of the bill of quantities, and they punish fragmented buying: different units for hallways, lobbies and entryways mean more suppliers, more SKUs and more spare-parts categories to manage for the life of the building. The Midea One-way Cassette Fan Coil Unit consolidates all of it into one family. A 153mm chassis slides into the narrow ceiling voids above corridors, lobbies and room entryways where standard cassettes simply do not fit, and the single-direction discharge throws conditioned air along the hallway instead of fighting the walls. With cooling capacities from 2.65 to 5.20 kW across the combined AC and DC range, one product family covers hotel corridors, office hallways, apartment foyers and retail perimeters — one supplier, one purchase order, one documentation set.

The built-in 750mm condensate pump is a procurement detail as much as an engineering one: no external pumps to source, no condensate accessories line item, and no water-damage rectification budget after handover. Units connect to a standard 220-240V / 1Ph / 50Hz circuit, and both motor tiers share the same body dimensions and G1/2" pipe connections — so AC and DC models are interchangeable on the schedule, and the spare-parts list stays short for the maintenance contractor who inherits the building.

Choose the DC version — a DC inverter brushless motor with seven fan speeds via the KJR-75A wired controller — and the units you hand over draw as little as 14W, cut fan energy by up to 30% and run 2-5 dB(A) quieter than the AC equivalent: the lifecycle-cost argument that gets owner sign-off on a modest premium. Power-off memory restores settings after outages, the washable filter pulls out from below in seconds, and the certification set — CE, Eurovent, ERP, RoHS, GB/T 19232 — is assembled for first-pass tender review. Hongtai backs every project with OEM/ODM support — custom voltages from 180-440V at 50/60Hz, project branding, Modbus RTU and BACnet protocols — plus dependable spare-parts supply long after handover.

Key Selling Points
  • One Family Covers Every Corridor Zone — AC 300-400 / DC 300-600 CFM and 2.65-5.20 kW span hallways, lobbies and perimeters from a single line on the purchase order.
  • 153mm Ultra-Slim Body — Fits narrow corridor ceiling voids; fewer design-driven re-procurement loops when drawings meet reality.
  • Built-In 750mm Drain Pump — No external pumps or condensate accessories to source; the leak-risk rectification budget disappears.
  • AC/DC Mix in One Purchase Order — Match the project budget structure: AC where capital cost rules, DC where lifecycle cost is evaluated.
  • Lifecycle Savings Built In (DC) — From 14W draw, up to 30% lower fan energy and 2-5 dB(A) quieter operation; an efficiency story owners approve.
  • Tender-Ready Certification Set — CE, Eurovent, ERP, RoHS and GB/T 19232 documentation passes consultant review the first time.
  • Shared Spares Across the Range — Same body, same G1/2" connections, same filters; a shorter spare-parts list for the maintenance phase.
  • OEM/ODM Project Support via Hongtai — Custom voltage (180-440V, 50/60Hz), branding and BMS protocols; one supplier from quotation to handover.
AC vs DC — Which Should You Specify?

For budget-led packages where 3-speed control meets the specification, the AC version holds the initial procurement cost down and keeps spares universal across the job. Where the owner's evaluation weighs running cost — hotel corridors and residential work especially — the DC inverter brushless version earns its premium: seven speeds for precise balancing at commissioning, up to 30% lower fan energy, and 2-5 dB(A) quieter operation. Both share the same 153mm body, 750mm pump and G1/2" connections, so you can mix motor tiers across zones within one order without multiplying SKUs or spares.

Applications
  1. Hotel Corridor Packages — Slim bodies run the full length of guestroom corridors; quiet DC models protect guest sleep quality and brand standards.
  2. Office Hallways and Lift Lobbies — Directional airflow conditions circulation zones efficiently without oversized capacity.
  3. Apartment Entry Halls — Compact profile preserves ceiling height in residential corridors, foyers and lift approaches.
  4. Retail Perimeter Zones — Single-direction discharge sweeps along shopfronts and display glazing without dead spots.
  5. Hospital Ward Corridors — Low-noise DC operation and tool-free filter service suit healthcare maintenance regimes.
Frequently Asked Questions
Q: Can this one series cover every corridor zone across the whole project?

A: Yes. With AC 300-400 CFM and DC 300-600 CFM tiers delivering 2.65-5.20 kW of cooling, the family covers hotel corridors, office hallways, apartment foyers and retail perimeters — consolidating what is usually several suppliers into one purchase order and one documentation set.

Q: Is the certification documentation complete enough for tender submission?

A: The range carries CE Marking, Eurovent Certified Performance, ERP and RoHS compliance, and GB/T 19232 national-standard testing — the document set consultants and design institutes routinely require, ready for first-pass review.

Q: Do AC and DC versions share spare parts?

A: They share the same 153mm body, the same 750mm drain pump and the same G1/2" pipe connections, so the spare-parts list for the maintenance phase stays short even when a project mixes both motor tiers.

Q: What power supply do the units need, and what about export grids?

A: Standard supply is 220-240V / 1Ph / 50Hz. For projects on other grids, Hongtai supports OEM/ODM custom voltages from 180-440V at 50/60Hz under the same project supply arrangement.

Q: Does the condensate pump need to be purchased separately?

A: No. A 750mm-lift drain pump is built in as standard on every unit — there is no separate pump line item, no accessory sourcing, and no compatibility risk between components.

Certifications & Standards
  • CE Marking — European conformity for safety and electromagnetic compatibility.
  • Eurovent Certified Performance — Third-party verified capacity and efficiency ratings.
  • ERP Compliant — Meets EU Energy-related Products Directive requirements.
  • RoHS Compliant — Restriction of Hazardous Substances directive conformance.
  • GB/T 19232 — Chinese national standard for fan coil unit performance testing.
Technical Specifications
Parameter AC Series DC Series
Airflow Range300-400 CFM300-600 CFM
Cooling Capacity3.04-3.79 kW2.65-5.20 kW
Heating Capacity5.13-6.41 kW3.15-5.75 kW
Power Input32-40 W14-38 W
Sound Pressure Level (H)36-37 dB(A)33.5-44.6 dB(A)
Power Supply220-240V / 1Ph / 50Hz220-240V / 1Ph / 50Hz
Drain Pump Head750 mm750 mm
Body Height153 mm153 mm
Coil Rows22
Max. Working Pressure1.6 MPa1.6 MPa
Motor TypeLow-noise 3-speed ACDC Brushless
Pipe ConnectionG1/2"G1/2"
Product Gallery
Related Search Terms

one way cassette FCU bulk purchase corridor fan coil unit project supply fan coil tender specification 153mm slim cassette FCU quotation fan coil unit lifecycle cost cassette FCU CE Eurovent certified hotel corridor FCU procurement OEM fan coil unit supplier

Sitemap |  Privacy Policy | China Good Quality DC Inverter VRF Supplier. Copyright © 2024-2026 Henan Hongtai HVAC Equipment Co., Ltd. . All Rights Reserved.