logo
Products
PRODUCTS DETAILS
Home > Products >
Midea Compact Cassette FCU OEM 575 575mm for 585mm Grid Markets Drop In Compact Cassette FCU Fast Moving Retrofit Line

Midea Compact Cassette FCU OEM 575 575mm for 585mm Grid Markets Drop In Compact Cassette FCU Fast Moving Retrofit Line

Detail Information
Place of Origin
China
Brand Name
OEM;MIDEA
Certification
CB,ISO
Product Name:
Compact Four-way Cassette
Airflow Range:
400–600 CFM 400–600 CFM
Cooling Capacity:
3.0–4.5 KW 2.98–4.78 KW
Heating Capacity:
4.0–6.0 KW 2.73–5.76 KW
Power Input:
30–95 W 5–43 W
Sound Pressure Level (H):
36–45 DB(A) 30–43 DB(A)
Power Supply:
220–240V / 1Ph / 50Hz
Motor Type:
Low-noise 3-speed AC DC Brushless
Highlight:

Midea compact cassette FCU 575mm

,

OEM cassette FCU for 585mm grid

,

drop-in retrofit cassette FCU

Product Description
Product Overview

Replacement and refurbishment is the steadiest demand in the FCU trade: buildings age, tenants change, and every old cassette eventually comes down. The Midea Compact Four-way Cassette Fan Coil Unit is sized to own that demand — a 575×575mm body that drops straight into the standard 585mm ceiling grid used in commercial buildings worldwide, so one SKU serves retrofit business across your whole territory. Your trade customers pull the old unit, drop this one in, reconnect and commission: no grid cutting, no custom framing, no ceiling patching. With 400–600 CFM and cooling capacities from 2.98 to 4.78 kW across the AC and DC range, it covers the small-to-medium zones that fill most refurbishment order books.

At 204mm body height — just 198mm on 3rd Generation DC models — the unit clears shallow ceiling voids that defeat standard cassettes, which turns the orders your competitors cannot fulfil into your repeat business. The 500mm drain pump (1200mm on 3rd Gen) removes condensate without slope work or structural drainage changes, the integrated safety mesh protects technicians during filter service, and the standard 360° panel delivers even distribution with no vane balancing at commissioning. Fewer site complications for your customers means fewer support escalations for you.

The DC inverter brushless version draws as little as 5W at low speed and cuts fan energy by up to 30% — the premium tier your customers quote when a landlord is replacing a whole floor. Seven fan speeds via the KJR-75A controller tune each room at handover, and 2-pipe or 4-pipe factory versions match whatever hydraulics the existing building delivers. All models run on 220–240V / 1Ph / 50Hz, and Hongtai supports distribution partners with OEM/ODM customisation — your brand on the panel, custom voltages from 180–440V at 50/60Hz, and Modbus/BACnet protocols — plus steady spare-parts supply across your selling seasons.

Key Selling Points
  • 575 × 575mm Grid-Standard Sizing — One SKU serves the worldwide 585mm ceiling-grid replacement market; retrofit demand becomes your repeat business.
  • 204mm / 198mm Shallow-Void Height — Wins orders in older buildings where standard cassettes cannot go and competitors walk away.
  • 500mm / 1200mm Drain Pump — Condensate handled without slope work; fewer leak-related claims reaching your warranty desk.
  • Standard 360° Panel — Even distribution with no vane balancing; fewer commissioning disputes travelling back through your channel.
  • Integrated Safety Mesh — Protects technicians during filter service; a compliance-friendly detail your trade customers value.
  • DC from 5W Low-Speed Draw — Up to 30% energy saving gives your brand a premium tier with real margin headroom.
  • 2-Pipe and 4-Pipe Versions — One supplier covers both hydraulics markets without site modification.
  • OEM/ODM via Hongtai — Private label, custom voltage (180–440V, 50/60Hz) and spare-parts continuity for your territory.
AC vs DC — Which Should You Specify?

Stock AC as the like-for-like replacement line: when your customers are swapping failed units against fixed budgets, it keeps the transaction simple and the price sharp. Stock DC as the upgrade line: from 5W at low speed, up to 30% less fan energy, seven speeds via the KJR-75A, and 198mm height on 3rd Generation models for the shallowest voids — the version your customers quote when an owner will live with the energy bills. Dimensions, grid fit and pipe connections are identical across both, so one parts stock and one installation method cover the whole line.

Applications
  1. Building Refurbishment Supply — Drop-in replacement keeps your customers' tenant disruption measured in hours, driving steady reorder cycles.
  2. Hotel Renovation Programmes — Compact height fits shallow guestroom-lobby ceilings; quiet DC operation protects guest experience.
  3. Healthcare Facility Upgrades — Safety mesh and low-noise DC models suit clinic and treatment-room compliance regimes.
  4. Office Tenant Fit-Out Distribution — Right-sized 400–600 CFM capacity covers the meeting rooms and small offices that fill fit-out schedules.
  5. Franchise and Chain Retail Rollouts — One standardised unit across every site simplifies your customers' procurement and your stock planning.
FAQ
Q: Is this compact cassette a viable volume line for a replacement-driven market?

A: Yes. The 575×575mm body is sized for the standard 585mm grid used in commercial buildings worldwide, so a single SKU addresses refurbishment and replacement demand across your territory without special-order variants.

Q: Can we order this line under our own brand?

A: Yes. Hongtai provides OEM/ODM support including private labelling and project branding, so the line ships under your distribution brand with documentation prepared for your market.

Q: Can voltage and frequency be matched to our national grid?

A: Standard supply is 220–240V / 1Ph / 50Hz. Hongtai's OEM/ODM programme supports custom voltages from 180–440V at 50/60Hz, covering most national grids for export orders.

Q: Are the certifications suitable for import into regulated markets?

A: The range carries CE marking, Eurovent certified performance, ERP and RoHS compliance, tested to GB/T 19232 — the export-oriented certification set. Share your local import requirements and Hongtai will align the shipment documentation.

Q: How should we tier AC and DC stock for our customers?

A: Hold AC for like-for-like swaps where budgets are fixed, and DC for whole-floor replacements where the owner pays the energy bills. Dimensions, grid fit and connections are identical, so both tiers sell through the same customer base with the same parts support.

Certifications & Standards
  • CE Marking — European conformity for safety and electromagnetic compatibility.
  • Eurovent Certified Performance — Third-party verified capacity and efficiency ratings.
  • ERP Compliant — Meets EU Energy-related Products Directive requirements.
  • RoHS Compliant — Restriction of Hazardous Substances directive conformance.
  • GB/T 19232 — Chinese national standard for fan coil unit performance testing.
Technical Specifications
Parameter AC Series DC Series
Airflow Range400–600 CFM400–600 CFM
Cooling Capacity3.0–4.5 kW2.98–4.78 kW
Heating Capacity4.0–6.0 kW2.73–5.76 kW
Power Input30–95 W5–43 W
Sound Pressure Level (H)36–45 dB(A)30–43 dB(A)
Power Supply220–240V / 1Ph / 50Hz220–240V / 1Ph / 50Hz
Drain Pump Head500 mm500 mm (1200 mm for 3rd Gen)
Body Height204 mm204 mm (198 mm for 3rd Gen)
Body Dimensions575×575 mm575×575 mm
Coil Rows22
Max. Working Pressure1.6 MPa1.6 MPa
Motor TypeLow-noise 3-speed ACDC Brushless
Pipe ConnectionG3/4"G3/4"
AEH OptionAvailableAvailable
Pipe System2-pipe / 4-pipe2-pipe / 4-pipe
Related Search Terms

compact cassette fan coil unit OEM · 575x575 cassette FCU manufacturer · 585mm grid cassette FCU wholesale · retrofit cassette FCU bulk supply · replacement cassette fan coil China · private label compact FCU exporter · shallow ceiling cassette FCU distributor · quiet DC cassette FCU wholesale

Products
PRODUCTS DETAILS
Midea Compact Cassette FCU OEM 575 575mm for 585mm Grid Markets Drop In Compact Cassette FCU Fast Moving Retrofit Line
Detail Information
Place of Origin
China
Brand Name
OEM;MIDEA
Certification
CB,ISO
Product Name:
Compact Four-way Cassette
Airflow Range:
400–600 CFM 400–600 CFM
Cooling Capacity:
3.0–4.5 KW 2.98–4.78 KW
Heating Capacity:
4.0–6.0 KW 2.73–5.76 KW
Power Input:
30–95 W 5–43 W
Sound Pressure Level (H):
36–45 DB(A) 30–43 DB(A)
Power Supply:
220–240V / 1Ph / 50Hz
Motor Type:
Low-noise 3-speed AC DC Brushless
Highlight

Midea compact cassette FCU 575mm

,

OEM cassette FCU for 585mm grid

,

drop-in retrofit cassette FCU

Product Description
Product Overview

Replacement and refurbishment is the steadiest demand in the FCU trade: buildings age, tenants change, and every old cassette eventually comes down. The Midea Compact Four-way Cassette Fan Coil Unit is sized to own that demand — a 575×575mm body that drops straight into the standard 585mm ceiling grid used in commercial buildings worldwide, so one SKU serves retrofit business across your whole territory. Your trade customers pull the old unit, drop this one in, reconnect and commission: no grid cutting, no custom framing, no ceiling patching. With 400–600 CFM and cooling capacities from 2.98 to 4.78 kW across the AC and DC range, it covers the small-to-medium zones that fill most refurbishment order books.

At 204mm body height — just 198mm on 3rd Generation DC models — the unit clears shallow ceiling voids that defeat standard cassettes, which turns the orders your competitors cannot fulfil into your repeat business. The 500mm drain pump (1200mm on 3rd Gen) removes condensate without slope work or structural drainage changes, the integrated safety mesh protects technicians during filter service, and the standard 360° panel delivers even distribution with no vane balancing at commissioning. Fewer site complications for your customers means fewer support escalations for you.

The DC inverter brushless version draws as little as 5W at low speed and cuts fan energy by up to 30% — the premium tier your customers quote when a landlord is replacing a whole floor. Seven fan speeds via the KJR-75A controller tune each room at handover, and 2-pipe or 4-pipe factory versions match whatever hydraulics the existing building delivers. All models run on 220–240V / 1Ph / 50Hz, and Hongtai supports distribution partners with OEM/ODM customisation — your brand on the panel, custom voltages from 180–440V at 50/60Hz, and Modbus/BACnet protocols — plus steady spare-parts supply across your selling seasons.

Key Selling Points
  • 575 × 575mm Grid-Standard Sizing — One SKU serves the worldwide 585mm ceiling-grid replacement market; retrofit demand becomes your repeat business.
  • 204mm / 198mm Shallow-Void Height — Wins orders in older buildings where standard cassettes cannot go and competitors walk away.
  • 500mm / 1200mm Drain Pump — Condensate handled without slope work; fewer leak-related claims reaching your warranty desk.
  • Standard 360° Panel — Even distribution with no vane balancing; fewer commissioning disputes travelling back through your channel.
  • Integrated Safety Mesh — Protects technicians during filter service; a compliance-friendly detail your trade customers value.
  • DC from 5W Low-Speed Draw — Up to 30% energy saving gives your brand a premium tier with real margin headroom.
  • 2-Pipe and 4-Pipe Versions — One supplier covers both hydraulics markets without site modification.
  • OEM/ODM via Hongtai — Private label, custom voltage (180–440V, 50/60Hz) and spare-parts continuity for your territory.
AC vs DC — Which Should You Specify?

Stock AC as the like-for-like replacement line: when your customers are swapping failed units against fixed budgets, it keeps the transaction simple and the price sharp. Stock DC as the upgrade line: from 5W at low speed, up to 30% less fan energy, seven speeds via the KJR-75A, and 198mm height on 3rd Generation models for the shallowest voids — the version your customers quote when an owner will live with the energy bills. Dimensions, grid fit and pipe connections are identical across both, so one parts stock and one installation method cover the whole line.

Applications
  1. Building Refurbishment Supply — Drop-in replacement keeps your customers' tenant disruption measured in hours, driving steady reorder cycles.
  2. Hotel Renovation Programmes — Compact height fits shallow guestroom-lobby ceilings; quiet DC operation protects guest experience.
  3. Healthcare Facility Upgrades — Safety mesh and low-noise DC models suit clinic and treatment-room compliance regimes.
  4. Office Tenant Fit-Out Distribution — Right-sized 400–600 CFM capacity covers the meeting rooms and small offices that fill fit-out schedules.
  5. Franchise and Chain Retail Rollouts — One standardised unit across every site simplifies your customers' procurement and your stock planning.
FAQ
Q: Is this compact cassette a viable volume line for a replacement-driven market?

A: Yes. The 575×575mm body is sized for the standard 585mm grid used in commercial buildings worldwide, so a single SKU addresses refurbishment and replacement demand across your territory without special-order variants.

Q: Can we order this line under our own brand?

A: Yes. Hongtai provides OEM/ODM support including private labelling and project branding, so the line ships under your distribution brand with documentation prepared for your market.

Q: Can voltage and frequency be matched to our national grid?

A: Standard supply is 220–240V / 1Ph / 50Hz. Hongtai's OEM/ODM programme supports custom voltages from 180–440V at 50/60Hz, covering most national grids for export orders.

Q: Are the certifications suitable for import into regulated markets?

A: The range carries CE marking, Eurovent certified performance, ERP and RoHS compliance, tested to GB/T 19232 — the export-oriented certification set. Share your local import requirements and Hongtai will align the shipment documentation.

Q: How should we tier AC and DC stock for our customers?

A: Hold AC for like-for-like swaps where budgets are fixed, and DC for whole-floor replacements where the owner pays the energy bills. Dimensions, grid fit and connections are identical, so both tiers sell through the same customer base with the same parts support.

Certifications & Standards
  • CE Marking — European conformity for safety and electromagnetic compatibility.
  • Eurovent Certified Performance — Third-party verified capacity and efficiency ratings.
  • ERP Compliant — Meets EU Energy-related Products Directive requirements.
  • RoHS Compliant — Restriction of Hazardous Substances directive conformance.
  • GB/T 19232 — Chinese national standard for fan coil unit performance testing.
Technical Specifications
Parameter AC Series DC Series
Airflow Range400–600 CFM400–600 CFM
Cooling Capacity3.0–4.5 kW2.98–4.78 kW
Heating Capacity4.0–6.0 kW2.73–5.76 kW
Power Input30–95 W5–43 W
Sound Pressure Level (H)36–45 dB(A)30–43 dB(A)
Power Supply220–240V / 1Ph / 50Hz220–240V / 1Ph / 50Hz
Drain Pump Head500 mm500 mm (1200 mm for 3rd Gen)
Body Height204 mm204 mm (198 mm for 3rd Gen)
Body Dimensions575×575 mm575×575 mm
Coil Rows22
Max. Working Pressure1.6 MPa1.6 MPa
Motor TypeLow-noise 3-speed ACDC Brushless
Pipe ConnectionG3/4"G3/4"
AEH OptionAvailableAvailable
Pipe System2-pipe / 4-pipe2-pipe / 4-pipe
Related Search Terms

compact cassette fan coil unit OEM · 575x575 cassette FCU manufacturer · 585mm grid cassette FCU wholesale · retrofit cassette FCU bulk supply · replacement cassette fan coil China · private label compact FCU exporter · shallow ceiling cassette FCU distributor · quiet DC cassette FCU wholesale

Sitemap |  Privacy Policy | China Good Quality DC Inverter VRF Supplier. Copyright © 2024-2026 Henan Hongtai HVAC Equipment Co., Ltd. . All Rights Reserved.
+86 18703827920