Refurbishment is the largest sustainability lever most portfolios still have, and the barrier is rarely ambition: it is that pulling an old cassette usually drags ceiling work, waste and programme with it. The Midea Compact Four-way Cassette Fan Coil Unit removes that barrier. A 575×575mm body drops straight into the standard 585mm ceiling grid used in commercial buildings worldwide, so the replacement is a swap rather than a construction event, with no grid cutting, no custom framing and no ceiling patching. Across the AC and DC range it covers 400-600 CFM and 2.98 to 4.78 kW of cooling, which is the capacity band most retrofit schedules of rates are actually made of.
At 204mm body height, and just 198mm on 3rd Generation DC models, the unit clears shallow voids that defeat standard cassettes, which is often the difference between a fabric-first retrofit and a ceiling rebuild. The 500mm drain pump (1200mm on 3rd Gen) removes condensate without slope work or structural drainage changes, and the integrated safety mesh protects technicians during filter service. The standard 360° panel delivers even distribution with no vane balancing at commissioning, so one less task sits between installation and a verified, balanced zone.
The DC inverter brushless version draws as little as 5W at low speed and cuts fan energy by up to 30%, which is the figure that turns a whole-floor replacement from a maintenance line into an energy project. Seven fan speeds via the KJR-75A controller let each room be balanced to its real load at handover, and 2-pipe or 4-pipe factory versions match whatever hydraulics the existing building provides, so no additional plant is introduced. All models run on standard 220-240V / 1Ph / 50Hz, and Hongtai supports chain-wide rollouts with OEM/ODM customisation covering custom voltages from 180-440V at 50/60Hz, project branding, and Modbus or BACnet protocols, plus steady spare-parts supply across the contract period. ERP and RoHS compliance is standard.
The AC version is the like-for-like swap: same day, same grid, lowest unit cost, and the right answer where the replacement budget is fixed by an insurance claim or a short refurbishment window. Where the owner will live with the energy bills, and especially where the building is being measured against a consumption baseline, the DC inverter brushless version is the stronger case: from 5W at low speed, up to 30% less fan energy, 2–5 dB(A) quieter, seven speeds via the KJR-75A, and 198mm height on 3rd Generation models for the shallowest voids. Dimensions, grid fit and pipe connections are identical, so both install the same way and the decision never touches the programme.
Fan energy falls by up to 30% against the AC equivalent, and the DC range draws as little as 5W at low speed. The saving scales with the number of units replaced and their running hours, so a floor of small zones benefits most.
Yes. ERP compliance covers the EU Energy-related Products Directive requirements and RoHS covers hazardous-substance restriction, on both AC and DC series, so a single certification file supports a multi-site replacement programme.
That is what the 575×575mm body is for. It drops into the standard 585mm grid, so the old unit comes out, the new one goes into the same opening, and the ceiling is left intact with no material sent to waste.
5W on the DC range at minimum speed, against a 5-43W band across the DC series and 30-95W for AC. Minimum-speed operation is where continuously occupied small zones spend most of their hours.
Yes. The DC range runs from 30 dB(A) at high speed down to near-inaudible levels at lower speeds, 2–5 dB(A) below the AC equivalent, which lets guestrooms and clinics stay on low speed without complaints.
| Parameter | AC Series | DC Series |
|---|---|---|
| Airflow Range | 400-600 CFM | 400-600 CFM |
| Cooling Capacity | 3.0-4.5 kW | 2.98-4.78 kW |
| Heating Capacity | 4.0-6.0 kW | 2.73-5.76 kW |
| Power Input | 30-95 W | 5-43 W |
| Sound Pressure Level (H) | 36-45 dB(A) | 30-43 dB(A) |
| Power Supply | 220-240V / 1Ph / 50Hz | 220-240V / 1Ph / 50Hz |
| Drain Pump Head | 500 mm | 500 mm (1200 mm for 3rd Gen) |
| Body Height | 204 mm | 204 mm (198 mm for 3rd Gen) |
| Body Dimensions | 575×575 mm | 575×575 mm |
| Coil Rows | 2 | 2 |
| Max. Working Pressure | 1.6 MPa | 1.6 MPa |
| Motor Type | Low-noise 3-speed AC | DC Brushless |
| Pipe Connection | G3/4" | G3/4" |
| AEH Option | Available | Available |
| Pipe System | 2-pipe / 4-pipe | 2-pipe / 4-pipe |
Refurbishment is the largest sustainability lever most portfolios still have, and the barrier is rarely ambition: it is that pulling an old cassette usually drags ceiling work, waste and programme with it. The Midea Compact Four-way Cassette Fan Coil Unit removes that barrier. A 575×575mm body drops straight into the standard 585mm ceiling grid used in commercial buildings worldwide, so the replacement is a swap rather than a construction event, with no grid cutting, no custom framing and no ceiling patching. Across the AC and DC range it covers 400-600 CFM and 2.98 to 4.78 kW of cooling, which is the capacity band most retrofit schedules of rates are actually made of.
At 204mm body height, and just 198mm on 3rd Generation DC models, the unit clears shallow voids that defeat standard cassettes, which is often the difference between a fabric-first retrofit and a ceiling rebuild. The 500mm drain pump (1200mm on 3rd Gen) removes condensate without slope work or structural drainage changes, and the integrated safety mesh protects technicians during filter service. The standard 360° panel delivers even distribution with no vane balancing at commissioning, so one less task sits between installation and a verified, balanced zone.
The DC inverter brushless version draws as little as 5W at low speed and cuts fan energy by up to 30%, which is the figure that turns a whole-floor replacement from a maintenance line into an energy project. Seven fan speeds via the KJR-75A controller let each room be balanced to its real load at handover, and 2-pipe or 4-pipe factory versions match whatever hydraulics the existing building provides, so no additional plant is introduced. All models run on standard 220-240V / 1Ph / 50Hz, and Hongtai supports chain-wide rollouts with OEM/ODM customisation covering custom voltages from 180-440V at 50/60Hz, project branding, and Modbus or BACnet protocols, plus steady spare-parts supply across the contract period. ERP and RoHS compliance is standard.
The AC version is the like-for-like swap: same day, same grid, lowest unit cost, and the right answer where the replacement budget is fixed by an insurance claim or a short refurbishment window. Where the owner will live with the energy bills, and especially where the building is being measured against a consumption baseline, the DC inverter brushless version is the stronger case: from 5W at low speed, up to 30% less fan energy, 2–5 dB(A) quieter, seven speeds via the KJR-75A, and 198mm height on 3rd Generation models for the shallowest voids. Dimensions, grid fit and pipe connections are identical, so both install the same way and the decision never touches the programme.
Fan energy falls by up to 30% against the AC equivalent, and the DC range draws as little as 5W at low speed. The saving scales with the number of units replaced and their running hours, so a floor of small zones benefits most.
Yes. ERP compliance covers the EU Energy-related Products Directive requirements and RoHS covers hazardous-substance restriction, on both AC and DC series, so a single certification file supports a multi-site replacement programme.
That is what the 575×575mm body is for. It drops into the standard 585mm grid, so the old unit comes out, the new one goes into the same opening, and the ceiling is left intact with no material sent to waste.
5W on the DC range at minimum speed, against a 5-43W band across the DC series and 30-95W for AC. Minimum-speed operation is where continuously occupied small zones spend most of their hours.
Yes. The DC range runs from 30 dB(A) at high speed down to near-inaudible levels at lower speeds, 2–5 dB(A) below the AC equivalent, which lets guestrooms and clinics stay on low speed without complaints.
| Parameter | AC Series | DC Series |
|---|---|---|
| Airflow Range | 400-600 CFM | 400-600 CFM |
| Cooling Capacity | 3.0-4.5 kW | 2.98-4.78 kW |
| Heating Capacity | 4.0-6.0 kW | 2.73-5.76 kW |
| Power Input | 30-95 W | 5-43 W |
| Sound Pressure Level (H) | 36-45 dB(A) | 30-43 dB(A) |
| Power Supply | 220-240V / 1Ph / 50Hz | 220-240V / 1Ph / 50Hz |
| Drain Pump Head | 500 mm | 500 mm (1200 mm for 3rd Gen) |
| Body Height | 204 mm | 204 mm (198 mm for 3rd Gen) |
| Body Dimensions | 575×575 mm | 575×575 mm |
| Coil Rows | 2 | 2 |
| Max. Working Pressure | 1.6 MPa | 1.6 MPa |
| Motor Type | Low-noise 3-speed AC | DC Brushless |
| Pipe Connection | G3/4" | G3/4" |
| AEH Option | Available | Available |
| Pipe System | 2-pipe / 4-pipe | 2-pipe / 4-pipe |