Concealed ducted systems are where an energy model meets as-built reality, and the gap usually shows up as airflow that does not match the design. The Midea Medium Static Pressure Duct Fan Coil Unit is built to close that gap rather than pass it to the commissioning report. On AC models, water connections reverse from left to right on site; on DC models, external static pressure is selectable at 12, 30 or 50Pa through the PCB or wired controller. Return air draws from the rear or the bottom. When the duct run grows two extra bends or the riser lands on the wrong side, the unit is set to suit it, so no unit is left running against a resistance it was not configured for. One family spans 400-1200 CFM with cooling capacities from 2.35 to 13.78 kW across the AC and DC range.
At 241mm body height (261mm for DC) the chassis hides above standard ceiling grids, while three-row and four-row coil options match two-pipe or four-pipe hydraulics across new-build and retrofit work. The enlarged drain pan option is cheap insurance against the call-back that undoes a fit-out: condensation stains on a finished ceiling, and the tile and insulation that go to waste with them. The filter assembly extracts in multiple directions, so maintenance access works however the void was built, which keeps the unit at rated performance instead of slowly starving for air between service visits.
The DC inverter brushless range provides seven fan speeds for balancing each zone at commissioning, up to 30% lower fan energy, and native V8 controller integration for jobs pairing FCUs with Midea VRF outdoor systems. XYE and PQE ports simplify central control and Modbus RTU handover, so the ducted terminals report into the same monitoring platform as the rest of the plant. Standard supply is 220-240V / 1Ph / 50Hz; for export contracts Hongtai provides OEM/ODM support with custom voltages from 180-440V at 50/60Hz, project branding and protocol options. ERP and RoHS compliance is standard across the range.
Start with the duct layout and the metering requirement. Where runs are short and direct and 3-speed control is enough, the AC range is the rugged default, and its on-site left/right piping reversal is genuine site-proofing. Where duct layouts are complex, part-load hours dominate, or the project reports energy intensity by zone, specify the DC inverter brushless range: external static selectable at 12/30/50Pa, seven speeds for precise balancing, up to 30% fan energy saving, and native V8 integration for combined FCU and VRF tenders. Coil options, connections and service access are shared, so the motor choice changes the operating profile, not the installation.
A: On DC models the 12/30/50Pa setting is made at commissioning through the PCB or wired controller, so airflow is matched to the ductwork that was actually built. A unit configured to its real resistance runs at the speed it needs rather than compensating for a mismatch.
A: Yes. XYE ports handle central control and PQE ports provide Modbus RTU, and the range integrates natively with Midea V8 VRF systems, so ducted terminals hand over cleanly to the building's monitoring platform.
A: Up to 30% against the AC equivalent, helped by seven speeds that let each zone run at part load rather than a single fixed speed. Actual savings depend on duct resistance and the balancing set at commissioning.
A: Yes, on both AC and DC series, so a concealed ducted schedule can be submitted with the same compliance documentation as the rest of the terminal package.
A: In most cases yes. Selectable static pressure on DC models, rear or bottom return air, and left/right reversible water connections on AC models let the unit adapt to the existing network instead of the network being rebuilt.
| Parameter | AC Series | DC Series |
|---|---|---|
| Airflow Range | 400-1200 CFM | 400-1200 CFM |
| Cooling Capacity | 2.35-13.0 kW | 2.35-13.78 kW |
| Heating Capacity | 3.90-22.17 kW | 3.90-13.30 kW |
| Power Input | 36-221 W | 5-552 W |
| Sound Pressure Level (H) | 35-52 dB(A) | 29-58 dB(A) |
| Power Supply | 220-240V / 1Ph / 50Hz | 220-240V / 1Ph / 50Hz |
| Body Height | 241 mm | 261 mm |
| External Static Pressure | 12/30/50 Pa (customizable) | 12/30/50 Pa (adjustable) |
| Coil Rows | 3 / 4 | 3 / 4 |
| Max. Working Pressure | 1.6 MPa | 1.6 MPa |
| Motor Type | Low-noise 3-speed AC | DC Brushless |
| Pipe Connection | RC3/4" | RC3/4" |
| AEH Option | Available | Available |
| Pipe System | 2-pipe / 4-pipe | 2-pipe / 4-pipe |





energy efficient duct fan coil unit · selectable ESP duct FCU · DC ducted fan coil 30% saving · Modbus duct FCU · low carbon concealed FCU · ERP compliant duct fan coil · green building ducted terminal · V8 compatible energy efficient FCU
Concealed ducted systems are where an energy model meets as-built reality, and the gap usually shows up as airflow that does not match the design. The Midea Medium Static Pressure Duct Fan Coil Unit is built to close that gap rather than pass it to the commissioning report. On AC models, water connections reverse from left to right on site; on DC models, external static pressure is selectable at 12, 30 or 50Pa through the PCB or wired controller. Return air draws from the rear or the bottom. When the duct run grows two extra bends or the riser lands on the wrong side, the unit is set to suit it, so no unit is left running against a resistance it was not configured for. One family spans 400-1200 CFM with cooling capacities from 2.35 to 13.78 kW across the AC and DC range.
At 241mm body height (261mm for DC) the chassis hides above standard ceiling grids, while three-row and four-row coil options match two-pipe or four-pipe hydraulics across new-build and retrofit work. The enlarged drain pan option is cheap insurance against the call-back that undoes a fit-out: condensation stains on a finished ceiling, and the tile and insulation that go to waste with them. The filter assembly extracts in multiple directions, so maintenance access works however the void was built, which keeps the unit at rated performance instead of slowly starving for air between service visits.
The DC inverter brushless range provides seven fan speeds for balancing each zone at commissioning, up to 30% lower fan energy, and native V8 controller integration for jobs pairing FCUs with Midea VRF outdoor systems. XYE and PQE ports simplify central control and Modbus RTU handover, so the ducted terminals report into the same monitoring platform as the rest of the plant. Standard supply is 220-240V / 1Ph / 50Hz; for export contracts Hongtai provides OEM/ODM support with custom voltages from 180-440V at 50/60Hz, project branding and protocol options. ERP and RoHS compliance is standard across the range.
Start with the duct layout and the metering requirement. Where runs are short and direct and 3-speed control is enough, the AC range is the rugged default, and its on-site left/right piping reversal is genuine site-proofing. Where duct layouts are complex, part-load hours dominate, or the project reports energy intensity by zone, specify the DC inverter brushless range: external static selectable at 12/30/50Pa, seven speeds for precise balancing, up to 30% fan energy saving, and native V8 integration for combined FCU and VRF tenders. Coil options, connections and service access are shared, so the motor choice changes the operating profile, not the installation.
A: On DC models the 12/30/50Pa setting is made at commissioning through the PCB or wired controller, so airflow is matched to the ductwork that was actually built. A unit configured to its real resistance runs at the speed it needs rather than compensating for a mismatch.
A: Yes. XYE ports handle central control and PQE ports provide Modbus RTU, and the range integrates natively with Midea V8 VRF systems, so ducted terminals hand over cleanly to the building's monitoring platform.
A: Up to 30% against the AC equivalent, helped by seven speeds that let each zone run at part load rather than a single fixed speed. Actual savings depend on duct resistance and the balancing set at commissioning.
A: Yes, on both AC and DC series, so a concealed ducted schedule can be submitted with the same compliance documentation as the rest of the terminal package.
A: In most cases yes. Selectable static pressure on DC models, rear or bottom return air, and left/right reversible water connections on AC models let the unit adapt to the existing network instead of the network being rebuilt.
| Parameter | AC Series | DC Series |
|---|---|---|
| Airflow Range | 400-1200 CFM | 400-1200 CFM |
| Cooling Capacity | 2.35-13.0 kW | 2.35-13.78 kW |
| Heating Capacity | 3.90-22.17 kW | 3.90-13.30 kW |
| Power Input | 36-221 W | 5-552 W |
| Sound Pressure Level (H) | 35-52 dB(A) | 29-58 dB(A) |
| Power Supply | 220-240V / 1Ph / 50Hz | 220-240V / 1Ph / 50Hz |
| Body Height | 241 mm | 261 mm |
| External Static Pressure | 12/30/50 Pa (customizable) | 12/30/50 Pa (adjustable) |
| Coil Rows | 3 / 4 | 3 / 4 |
| Max. Working Pressure | 1.6 MPa | 1.6 MPa |
| Motor Type | Low-noise 3-speed AC | DC Brushless |
| Pipe Connection | RC3/4" | RC3/4" |
| AEH Option | Available | Available |
| Pipe System | 2-pipe / 4-pipe | 2-pipe / 4-pipe |





energy efficient duct fan coil unit · selectable ESP duct FCU · DC ducted fan coil 30% saving · Modbus duct FCU · low carbon concealed FCU · ERP compliant duct fan coil · green building ducted terminal · V8 compatible energy efficient FCU