logo
Products
PRODUCTS DETAILS
Home > Products >
Midea VC Max DOAS Hotel Fresh Air System for Superior Guest Room Air Quality The Invisible Upgrade Every Guest Notices: Cleaner Fresher More Comfortible Air

Midea VC Max DOAS Hotel Fresh Air System for Superior Guest Room Air Quality The Invisible Upgrade Every Guest Notices: Cleaner Fresher More Comfortible Air

Detail Information
Place of Origin
China
Brand Name
OEM;MIDEA
Certification
CB,ISO
Product Name:
VC Max (DOAS)
Capacity Range:
8 - 24 HP
Cooling Capacity:
1,500 - 10,000 M3/h
Energy Recovery:
High-efficiency Plate Heat Exchanger
Communication Protocol:
BACnet / Modbus RTU
Power Supply:
380-415V / 3Ph / 50Hz
Climate Rating:
T3 (55 Degrees Celsius)
Certifications CE, Eurovent, TUV SUD, ISO 9001/14001/45001:
CE, Eurovent, TUV SUD, ISO 9001/14001/45001
Highlight:

Midea VC Max fresh air system

,

DOAS hotel guest room ventilation

,

DC inverter VRF air quality

Product Description
Product Overview: Midea VC Max DOAS for Hotel Fresh Air

The Midea VC Max is a dedicated outdoor air processing system (DOAS) that transforms hotel indoor air quality from an afterthought into a competitive differentiator. With a capacity range of 8 to 24 HP, the VC Max conditions 100% outdoor air, removing humidity, filtering pollutants, and delivering a continuous supply of fresh, clean air to every connected guest room and public space. In an era where guests are increasingly aware of air quality and ventilation's role in health and wellbeing, the VC Max turns fresh air into a tangible, marketable guest experience advantage.

For hotel operators, the VC Max addresses one of the most common and persistent guest complaints: the stuffy, stale feeling that greets guests entering a room left unoccupied with the HVAC system in energy-saving mode. Traditional energy-saving strategies reduce or stop ventilation to save energy, but at the cost of air freshness. The VC Max solves this dilemma through energy recovery technology that pre-conditions incoming fresh air using the energy from exhaust air, delivering ventilation without the energy penalty that traditionally accompanies it.

The system's deep dehumidification capability is particularly valuable for hotels in tropical and coastal destinations where humidity, not temperature, is the primary source of guest discomfort. Rooms maintained at 24°C but at 70% relative humidity feel clammy and uncomfortable regardless of the thermostat setting. The VC Max removes moisture from incoming air, delivering supply air at comfortable humidity levels that make every room feel crisp, dry, and inviting from the moment guests walk in.

Key Features of the VC Max DOAS
1. 100% Outdoor Air Processing for Guest Room Freshness

Unlike conventional HVAC systems that recirculate indoor air with minimal fresh air introduction, the VC Max is designed to condition 100% outdoor air. Every liter of air delivered to guest rooms is drawn from outside, filtered, dehumidified or humidified as needed, and tempered to comfortable conditions before entering the space. This approach ensures that guest rooms never suffer from CO2 buildup, stale odors, or the accumulated VOCs that off-gas from furnishings in sealed environments.

For guests, the difference is immediately perceptible: the room feels fresh, as if a window is open, even in a sealed building. This sensation is particularly noticeable when entering a room after it has been unoccupied. Instead of the stale, stuffy greeting from a sealed room, guests encounter air that feels clean and invigorating, setting a positive tone for their entire stay and creating the kind of subtle comfort distinction that earns repeat bookings.

  • 100% outdoor air eliminates CO2 buildup in sealed guest rooms
  • Filtered supply air removes particulates, pollen, and urban pollutants
  • Consistent fresh air delivery prevents stale odors from furnishings and carpets
  • Noticeable freshness difference perceptible to guests immediately upon room entry
  • Positive first impression sets the tone for the entire guest stay experience
  • Differentiates the property from competitors using conventional recirculation systems
2. Deep Dehumidification for Tropical and Coastal Hotel Comfort

Temperature is only half the comfort equation. In tropical and coastal hotel markets, high humidity levels are the primary source of guest discomfort, creating the clammy, sticky feeling that makes guests turn the thermostat lower and lower without achieving satisfaction. The VC Max addresses humidity directly, removing moisture from incoming outdoor air to deliver supply air at humidity levels that keep rooms feeling crisp and dry even when outdoor humidity exceeds 80%.

This deep dehumidification capability has a cascading benefit for the hotel. When humidity is controlled at the source through the DOAS system, guest room VRF units do not need to overwork to remove latent moisture loads. They can operate at their most efficient setpoints, focusing on sensible temperature control while the VC Max handles the latent load. This division of labor improves the efficiency of both systems and creates a more comfortable room environment than either system could achieve independently.

  • Deep dehumidification removes moisture from incoming air regardless of outdoor humidity
  • Rooms feel crisp and dry even when outdoor relative humidity exceeds 80%
  • Eliminates the clammy discomfort that drives guests to over-cool their rooms
  • Reduces latent load on guest room VRF units, improving their operating efficiency
  • Prevents condensation, mold growth, and musty odors in guest rooms and linens
  • Creates a perceptible comfort advantage in tropical and coastal hotel destinations

The dehumidification advantage also protects the hotel's physical assets. High humidity accelerates the deterioration of furnishings, damages electronics, promotes mold growth in bathrooms and linens, and creates the musty odors that guests associate with poorly maintained properties. By maintaining supply air at low humidity levels, the VC Max extends the service life of room interiors, protects guest belongings from moisture damage, and ensures that every room smells fresh and clean regardless of outdoor weather conditions.

3. Energy Recovery Reducing Fresh Air Ventilation Costs

Ventilating with 100% outdoor air is energy-intensive because every cubic meter of incoming air must be cooled, dehumidified, heated, or humidified to indoor conditions. Without energy recovery, the ventilation energy cost would make the VC Max uneconomical for most hotel applications. The system's high-efficiency energy recovery core changes this equation entirely.

The energy recovery core transfers thermal energy from the exhaust air stream to the incoming fresh air stream, pre-conditioning the outdoor air before it reaches the cooling or heating coil. In cooling mode, the cool exhaust air pre-cools the hot incoming outdoor air, reducing the cooling coil's workload by up to 50%. In heating mode, the warm exhaust air pre-heats the cold incoming air with similar efficiency gains. The result is full fresh air ventilation at a fraction of the energy cost, making the VC Max an economically viable solution even for budget-conscious hotel operators.

  • Energy recovery core transfers thermal energy from exhaust to incoming fresh air
  • Pre-conditioning reduces cooling or heating coil workload by up to 50%
  • Full fresh air ventilation delivered at a fraction of the energy cost without recovery
  • Cooling mode energy savings are most significant in hot, humid climate hotel markets
  • Heating mode energy recovery provides substantial savings in cold climate applications
  • Makes 100% outdoor air ventilation economically viable for all hotel segments
4. Supporting Green Hotel and Healthy Building Certifications

As the hospitality industry embraces sustainability and guest health commitments, green building certifications such as LEED, WELL, Green Key, and local eco-label programs have become important differentiators for hotels seeking to attract environmentally conscious travelers and corporate clients with sustainability procurement policies. The VC Max directly supports multiple certification criteria across these programs.

The system's energy recovery capability contributes to energy performance credits. Its 100% outdoor air delivery supports indoor environmental quality requirements for ventilation rates. Advanced filtration options address air quality standards for particulate removal. Hotels pursuing green certifications can document the VC Max's contribution to specific credit categories, accelerating the certification process and strengthening the hotel's sustainability narrative for marketing and public relations purposes.

  • Directly supports LEED, WELL, Green Key, and local eco-label certification criteria
  • Energy recovery contributes to energy performance and efficiency credits
  • 100% outdoor air delivery meets ventilation rate requirements
  • Advanced filtration options address indoor air quality particulate standards
  • Documentation support accelerates green certification application processes
  • Sustainability narrative strengthens hotel marketing to eco-conscious travelers and corporate clients
5. Differentiated Air Quality for Public Areas and Guest Zones

Not all hotel spaces have the same air quality requirements. A busy hotel lobby with continuous foot traffic, a packed restaurant during dinner service, and a conference room with fifty attendees all generate different contamination loads and ventilation demands. The VC Max system supports zone-level air quality management that tailors fresh air delivery to each area's specific needs.

High-traffic public areas receive elevated ventilation rates to handle the increased CO2 and odor loads from dense occupant presence. Guest room floors receive steady, moderate ventilation rates optimized for comfort and efficiency. Spa and fitness areas receive enhanced ventilation and dehumidification to manage moisture loads. This differentiated approach ensures that every area of the hotel has the appropriate air quality for its function, creating a consistently positive experience whether guests are in the lobby, the restaurant, or retiring to their rooms.

  • Zone-level air quality management tailors fresh air delivery to each area's needs
  • High-traffic public areas receive elevated ventilation for CO2 and odor control
  • Guest room floors receive moderate steady ventilation optimized for comfort and efficiency
  • Spa and fitness zones receive enhanced dehumidification for moisture load management
  • Differentiated approach ensures appropriate air quality for each functional area
  • Consistently positive guest experience across all hotel zones and public spaces
6. Hygienic Design and Advanced Filtration for Guest Health Protection

Post-pandemic guests are more aware of air quality and its relationship to health than ever before. Hotels that can demonstrate proactive air quality management gain a trust advantage with health-conscious travelers. The VC Max features a hygienic interior design with smooth, cleanable surfaces and anti-bacterial coil coatings that resist microbial growth on the moist surfaces inherent in air handling equipment.

Multi-stage filtration options allow hotels to select the level of air cleaning appropriate for their market positioning. Standard filters capture dust and large particulates. Enhanced filtration options capture fine particulates down to PM2.5 levels, addressing urban air quality concerns. For hotels in markets with seasonal air quality challenges such as wildfire smoke or dust storms, the highest filtration tier delivers visible, measurable air quality improvement that guests can see and appreciate, turning a health concern into a competitive advantage.

  • Hygienic interior design with smooth, cleanable surfaces prevents contamination buildup
  • Anti-bacterial coil coatings resist microbial growth on moisture-prone surfaces
  • Multi-stage filtration options from standard dust capture to PM2.5 fine particulate removal
  • Addresses urban air quality concerns including pollen, smoke, and dust storm events
  • Visible air quality improvement becomes a marketable guest health benefit
  • Post-pandemic health-conscious travelers recognize and reward proactive air quality management

Hotels that invest in the VC Max's advanced filtration and hygienic design gain a powerful marketing narrative. Guest-facing communications highlighting filtered fresh air, anti-bacterial coil protection, and continuous ventilation differentiate the property on online booking platforms where health and safety filters are increasingly prominent. Corporate travel departments evaluating hotel options for their employees increasingly prioritize properties that can demonstrate verified air quality management, making the VC Max an investment in both guest health and revenue generation.

Technical Specifications
Parameter Specification
Model SeriesVC Max (DOAS)
BrandMidea / Hongtai
Capacity Range8 – 24 HP
Fresh Air Volume1,500 – 10,000 m³/h
FunctionDedicated Outdoor Air Processing (100% OA)
Energy RecoveryHigh-efficiency plate heat exchanger
Dehumidification CapacityDeep dehumidification to below 40% RH supply
FiltrationMulti-stage: G4 pre-filter + F7/F9 final filter
Climate RatingT3 (55°C)
Communication ProtocolBACnet / Modbus RTU
Power Supply380–415V / 3Ph / 50Hz
Warranty5 Years
OriginChina
CertificationsCE, Eurovent, TUV SUD, ISO 9001/14001/45001
Applications
  • Luxury Hotel Guest Room Ventilation: Delivering continuous fresh air to guest rooms for premium comfort and a health-conscious guest experience.
  • Hotel Lobby and Public Area Air Quality: Managing ventilation for high-occupancy public spaces with variable foot traffic throughout the day.
  • Tropical Resort Dehumidification: Deep humidity control for coastal and tropical hotel destinations where moisture is the primary comfort challenge.
  • Conference and Convention Hotels: Enhanced ventilation for ballrooms and meeting rooms hosting dense occupant loads during events.
  • Green Hotel Certification Projects: Supporting LEED, WELL, or Green Key certification through energy recovery and outdoor air delivery.
  • Health and Wellness Resort Spas: Specialized ventilation and dehumidification for spa, hammam, and wellness areas with high moisture generation.
Certifications & Standards
  • CE Certified for European Market Compliance
  • Eurovent Certified Performance for Air Handling Units
  • TUV SUD Tested and Certified
  • ISO 9001 Quality Management System
  • ISO 14001 Environmental Management System
  • ISO 45001 Occupational Health and Safety Management System
  • T3 Tropical Climate Rating for Extreme Temperature Operation
  • Compliant with International Ventilation and Indoor Air Quality Standards
Product Gallery
Products
PRODUCTS DETAILS
Midea VC Max DOAS Hotel Fresh Air System for Superior Guest Room Air Quality The Invisible Upgrade Every Guest Notices: Cleaner Fresher More Comfortible Air
Detail Information
Place of Origin
China
Brand Name
OEM;MIDEA
Certification
CB,ISO
Product Name:
VC Max (DOAS)
Capacity Range:
8 - 24 HP
Cooling Capacity:
1,500 - 10,000 M3/h
Energy Recovery:
High-efficiency Plate Heat Exchanger
Communication Protocol:
BACnet / Modbus RTU
Power Supply:
380-415V / 3Ph / 50Hz
Climate Rating:
T3 (55 Degrees Celsius)
Certifications CE, Eurovent, TUV SUD, ISO 9001/14001/45001:
CE, Eurovent, TUV SUD, ISO 9001/14001/45001
Highlight

Midea VC Max fresh air system

,

DOAS hotel guest room ventilation

,

DC inverter VRF air quality

Product Description
Product Overview: Midea VC Max DOAS for Hotel Fresh Air

The Midea VC Max is a dedicated outdoor air processing system (DOAS) that transforms hotel indoor air quality from an afterthought into a competitive differentiator. With a capacity range of 8 to 24 HP, the VC Max conditions 100% outdoor air, removing humidity, filtering pollutants, and delivering a continuous supply of fresh, clean air to every connected guest room and public space. In an era where guests are increasingly aware of air quality and ventilation's role in health and wellbeing, the VC Max turns fresh air into a tangible, marketable guest experience advantage.

For hotel operators, the VC Max addresses one of the most common and persistent guest complaints: the stuffy, stale feeling that greets guests entering a room left unoccupied with the HVAC system in energy-saving mode. Traditional energy-saving strategies reduce or stop ventilation to save energy, but at the cost of air freshness. The VC Max solves this dilemma through energy recovery technology that pre-conditions incoming fresh air using the energy from exhaust air, delivering ventilation without the energy penalty that traditionally accompanies it.

The system's deep dehumidification capability is particularly valuable for hotels in tropical and coastal destinations where humidity, not temperature, is the primary source of guest discomfort. Rooms maintained at 24°C but at 70% relative humidity feel clammy and uncomfortable regardless of the thermostat setting. The VC Max removes moisture from incoming air, delivering supply air at comfortable humidity levels that make every room feel crisp, dry, and inviting from the moment guests walk in.

Key Features of the VC Max DOAS
1. 100% Outdoor Air Processing for Guest Room Freshness

Unlike conventional HVAC systems that recirculate indoor air with minimal fresh air introduction, the VC Max is designed to condition 100% outdoor air. Every liter of air delivered to guest rooms is drawn from outside, filtered, dehumidified or humidified as needed, and tempered to comfortable conditions before entering the space. This approach ensures that guest rooms never suffer from CO2 buildup, stale odors, or the accumulated VOCs that off-gas from furnishings in sealed environments.

For guests, the difference is immediately perceptible: the room feels fresh, as if a window is open, even in a sealed building. This sensation is particularly noticeable when entering a room after it has been unoccupied. Instead of the stale, stuffy greeting from a sealed room, guests encounter air that feels clean and invigorating, setting a positive tone for their entire stay and creating the kind of subtle comfort distinction that earns repeat bookings.

  • 100% outdoor air eliminates CO2 buildup in sealed guest rooms
  • Filtered supply air removes particulates, pollen, and urban pollutants
  • Consistent fresh air delivery prevents stale odors from furnishings and carpets
  • Noticeable freshness difference perceptible to guests immediately upon room entry
  • Positive first impression sets the tone for the entire guest stay experience
  • Differentiates the property from competitors using conventional recirculation systems
2. Deep Dehumidification for Tropical and Coastal Hotel Comfort

Temperature is only half the comfort equation. In tropical and coastal hotel markets, high humidity levels are the primary source of guest discomfort, creating the clammy, sticky feeling that makes guests turn the thermostat lower and lower without achieving satisfaction. The VC Max addresses humidity directly, removing moisture from incoming outdoor air to deliver supply air at humidity levels that keep rooms feeling crisp and dry even when outdoor humidity exceeds 80%.

This deep dehumidification capability has a cascading benefit for the hotel. When humidity is controlled at the source through the DOAS system, guest room VRF units do not need to overwork to remove latent moisture loads. They can operate at their most efficient setpoints, focusing on sensible temperature control while the VC Max handles the latent load. This division of labor improves the efficiency of both systems and creates a more comfortable room environment than either system could achieve independently.

  • Deep dehumidification removes moisture from incoming air regardless of outdoor humidity
  • Rooms feel crisp and dry even when outdoor relative humidity exceeds 80%
  • Eliminates the clammy discomfort that drives guests to over-cool their rooms
  • Reduces latent load on guest room VRF units, improving their operating efficiency
  • Prevents condensation, mold growth, and musty odors in guest rooms and linens
  • Creates a perceptible comfort advantage in tropical and coastal hotel destinations

The dehumidification advantage also protects the hotel's physical assets. High humidity accelerates the deterioration of furnishings, damages electronics, promotes mold growth in bathrooms and linens, and creates the musty odors that guests associate with poorly maintained properties. By maintaining supply air at low humidity levels, the VC Max extends the service life of room interiors, protects guest belongings from moisture damage, and ensures that every room smells fresh and clean regardless of outdoor weather conditions.

3. Energy Recovery Reducing Fresh Air Ventilation Costs

Ventilating with 100% outdoor air is energy-intensive because every cubic meter of incoming air must be cooled, dehumidified, heated, or humidified to indoor conditions. Without energy recovery, the ventilation energy cost would make the VC Max uneconomical for most hotel applications. The system's high-efficiency energy recovery core changes this equation entirely.

The energy recovery core transfers thermal energy from the exhaust air stream to the incoming fresh air stream, pre-conditioning the outdoor air before it reaches the cooling or heating coil. In cooling mode, the cool exhaust air pre-cools the hot incoming outdoor air, reducing the cooling coil's workload by up to 50%. In heating mode, the warm exhaust air pre-heats the cold incoming air with similar efficiency gains. The result is full fresh air ventilation at a fraction of the energy cost, making the VC Max an economically viable solution even for budget-conscious hotel operators.

  • Energy recovery core transfers thermal energy from exhaust to incoming fresh air
  • Pre-conditioning reduces cooling or heating coil workload by up to 50%
  • Full fresh air ventilation delivered at a fraction of the energy cost without recovery
  • Cooling mode energy savings are most significant in hot, humid climate hotel markets
  • Heating mode energy recovery provides substantial savings in cold climate applications
  • Makes 100% outdoor air ventilation economically viable for all hotel segments
4. Supporting Green Hotel and Healthy Building Certifications

As the hospitality industry embraces sustainability and guest health commitments, green building certifications such as LEED, WELL, Green Key, and local eco-label programs have become important differentiators for hotels seeking to attract environmentally conscious travelers and corporate clients with sustainability procurement policies. The VC Max directly supports multiple certification criteria across these programs.

The system's energy recovery capability contributes to energy performance credits. Its 100% outdoor air delivery supports indoor environmental quality requirements for ventilation rates. Advanced filtration options address air quality standards for particulate removal. Hotels pursuing green certifications can document the VC Max's contribution to specific credit categories, accelerating the certification process and strengthening the hotel's sustainability narrative for marketing and public relations purposes.

  • Directly supports LEED, WELL, Green Key, and local eco-label certification criteria
  • Energy recovery contributes to energy performance and efficiency credits
  • 100% outdoor air delivery meets ventilation rate requirements
  • Advanced filtration options address indoor air quality particulate standards
  • Documentation support accelerates green certification application processes
  • Sustainability narrative strengthens hotel marketing to eco-conscious travelers and corporate clients
5. Differentiated Air Quality for Public Areas and Guest Zones

Not all hotel spaces have the same air quality requirements. A busy hotel lobby with continuous foot traffic, a packed restaurant during dinner service, and a conference room with fifty attendees all generate different contamination loads and ventilation demands. The VC Max system supports zone-level air quality management that tailors fresh air delivery to each area's specific needs.

High-traffic public areas receive elevated ventilation rates to handle the increased CO2 and odor loads from dense occupant presence. Guest room floors receive steady, moderate ventilation rates optimized for comfort and efficiency. Spa and fitness areas receive enhanced ventilation and dehumidification to manage moisture loads. This differentiated approach ensures that every area of the hotel has the appropriate air quality for its function, creating a consistently positive experience whether guests are in the lobby, the restaurant, or retiring to their rooms.

  • Zone-level air quality management tailors fresh air delivery to each area's needs
  • High-traffic public areas receive elevated ventilation for CO2 and odor control
  • Guest room floors receive moderate steady ventilation optimized for comfort and efficiency
  • Spa and fitness zones receive enhanced dehumidification for moisture load management
  • Differentiated approach ensures appropriate air quality for each functional area
  • Consistently positive guest experience across all hotel zones and public spaces
6. Hygienic Design and Advanced Filtration for Guest Health Protection

Post-pandemic guests are more aware of air quality and its relationship to health than ever before. Hotels that can demonstrate proactive air quality management gain a trust advantage with health-conscious travelers. The VC Max features a hygienic interior design with smooth, cleanable surfaces and anti-bacterial coil coatings that resist microbial growth on the moist surfaces inherent in air handling equipment.

Multi-stage filtration options allow hotels to select the level of air cleaning appropriate for their market positioning. Standard filters capture dust and large particulates. Enhanced filtration options capture fine particulates down to PM2.5 levels, addressing urban air quality concerns. For hotels in markets with seasonal air quality challenges such as wildfire smoke or dust storms, the highest filtration tier delivers visible, measurable air quality improvement that guests can see and appreciate, turning a health concern into a competitive advantage.

  • Hygienic interior design with smooth, cleanable surfaces prevents contamination buildup
  • Anti-bacterial coil coatings resist microbial growth on moisture-prone surfaces
  • Multi-stage filtration options from standard dust capture to PM2.5 fine particulate removal
  • Addresses urban air quality concerns including pollen, smoke, and dust storm events
  • Visible air quality improvement becomes a marketable guest health benefit
  • Post-pandemic health-conscious travelers recognize and reward proactive air quality management

Hotels that invest in the VC Max's advanced filtration and hygienic design gain a powerful marketing narrative. Guest-facing communications highlighting filtered fresh air, anti-bacterial coil protection, and continuous ventilation differentiate the property on online booking platforms where health and safety filters are increasingly prominent. Corporate travel departments evaluating hotel options for their employees increasingly prioritize properties that can demonstrate verified air quality management, making the VC Max an investment in both guest health and revenue generation.

Technical Specifications
Parameter Specification
Model SeriesVC Max (DOAS)
BrandMidea / Hongtai
Capacity Range8 – 24 HP
Fresh Air Volume1,500 – 10,000 m³/h
FunctionDedicated Outdoor Air Processing (100% OA)
Energy RecoveryHigh-efficiency plate heat exchanger
Dehumidification CapacityDeep dehumidification to below 40% RH supply
FiltrationMulti-stage: G4 pre-filter + F7/F9 final filter
Climate RatingT3 (55°C)
Communication ProtocolBACnet / Modbus RTU
Power Supply380–415V / 3Ph / 50Hz
Warranty5 Years
OriginChina
CertificationsCE, Eurovent, TUV SUD, ISO 9001/14001/45001
Applications
  • Luxury Hotel Guest Room Ventilation: Delivering continuous fresh air to guest rooms for premium comfort and a health-conscious guest experience.
  • Hotel Lobby and Public Area Air Quality: Managing ventilation for high-occupancy public spaces with variable foot traffic throughout the day.
  • Tropical Resort Dehumidification: Deep humidity control for coastal and tropical hotel destinations where moisture is the primary comfort challenge.
  • Conference and Convention Hotels: Enhanced ventilation for ballrooms and meeting rooms hosting dense occupant loads during events.
  • Green Hotel Certification Projects: Supporting LEED, WELL, or Green Key certification through energy recovery and outdoor air delivery.
  • Health and Wellness Resort Spas: Specialized ventilation and dehumidification for spa, hammam, and wellness areas with high moisture generation.
Certifications & Standards
  • CE Certified for European Market Compliance
  • Eurovent Certified Performance for Air Handling Units
  • TUV SUD Tested and Certified
  • ISO 9001 Quality Management System
  • ISO 14001 Environmental Management System
  • ISO 45001 Occupational Health and Safety Management System
  • T3 Tropical Climate Rating for Extreme Temperature Operation
  • Compliant with International Ventilation and Indoor Air Quality Standards
Product Gallery
Sitemap |  Privacy Policy | China Good Quality DC Inverter VRF Supplier. Copyright © 2024-2026 Henan Hongtai HVAC Equipment Co., Ltd. . All Rights Reserved.
+86 18703827920