The V8 Pro sits between the flagship and economy tiers of our full DC inverter VRF range, and it is the model most consultants specify when a project needs both capacity density and predictable operating cost. One module delivers 8–36HP, and modules combine transparently up to 108HP with a combination ratio of 50%–130%, expandable to 200% in specific conditions. A single system can address up to 64 indoor units, covering a complete mid-rise office floor plate or a full hotel wing.
Duty cycling technology is the signature of this platform. The controller rotates the lead module on a scheduled basis so that run hours distribute evenly across the plant. Compressors, fans and inverters therefore age at the same rate, maintenance windows can be planned for the whole bank instead of one unit at a time, and standby modules remain genuinely exercised rather than sitting idle for years and failing on first start.
Heating performance extends well into cold climates. The system keeps producing usable heating capacity at low ambient temperatures with intelligent defrost logic that reads outdoor coil conditions instead of simply reacting on a timer, so defrost cycles are shorter and less frequent. Seasonal figures of SEER 5.80–7.55 and SCOP 4.25–4.48 are achieved across the capacity range, not only at nominal conditions.
Commissioning is simplified by automatic addressing and a self-diagnostic routine that verifies communication, sensor wiring and refrigerant charge before the system is handed over. Technicians can read module status, pressure and temperature data from the wired controller or the centralised monitoring platform.
| Parameter | Specification |
|---|---|
| Product Name | V8 Pro VRF System |
| Capacity Range | 8–108HP combinable / 8–36HP individual unit |
| Cooling Capacity | 25.2–90kW (individual unit) |
| Heating Capacity | 27–100kW (individual unit) |
| SEER | 5.80–7.55 |
| SCOP | 4.25–4.48 |
| Max Connected Indoor Units | 64 units |
| Refrigerant | R410A |
| Power Supply | 380–415V / 3Ph / 50Hz |
| External Static Pressure | 0–120Pa adjustable |
| Combination Ratio | 50%–130% (up to 200% in specific conditions) |
| Low Ambient Heating | Stable operation in cold climate conditions |
Typical installations include mid-rise office buildings, hotels, serviced apartments, schools and outpatient clinics where the plant runs long hours and maintenance access is limited. Duty cycling means the facilities team can service one module during working hours while the others carry the load, avoiding weekend shutdowns.
The platform also suits staged developments. A first phase can be commissioned with two or three modules and the remaining capacity added later against the same pipework and control network, which keeps capital spending aligned with occupancy.
Modules are shipped upright on reinforced pallets with corner protectors, refrigerant service ports capped and sealed, and a wiring diagram plus commissioning checklist in each carton. Crates are sized for standard 20ft and 40ft containers with forklift access on all four sides.
| MOQ: | Negotiable |
| Price: | Negotiable |
| Standard Packaging: | Standard export packing |
| Delivery Period: | Negotiable |
| Payment Method: | TT |
| Supply Capacity: | Negotiable |
The V8 Pro sits between the flagship and economy tiers of our full DC inverter VRF range, and it is the model most consultants specify when a project needs both capacity density and predictable operating cost. One module delivers 8–36HP, and modules combine transparently up to 108HP with a combination ratio of 50%–130%, expandable to 200% in specific conditions. A single system can address up to 64 indoor units, covering a complete mid-rise office floor plate or a full hotel wing.
Duty cycling technology is the signature of this platform. The controller rotates the lead module on a scheduled basis so that run hours distribute evenly across the plant. Compressors, fans and inverters therefore age at the same rate, maintenance windows can be planned for the whole bank instead of one unit at a time, and standby modules remain genuinely exercised rather than sitting idle for years and failing on first start.
Heating performance extends well into cold climates. The system keeps producing usable heating capacity at low ambient temperatures with intelligent defrost logic that reads outdoor coil conditions instead of simply reacting on a timer, so defrost cycles are shorter and less frequent. Seasonal figures of SEER 5.80–7.55 and SCOP 4.25–4.48 are achieved across the capacity range, not only at nominal conditions.
Commissioning is simplified by automatic addressing and a self-diagnostic routine that verifies communication, sensor wiring and refrigerant charge before the system is handed over. Technicians can read module status, pressure and temperature data from the wired controller or the centralised monitoring platform.
| Parameter | Specification |
|---|---|
| Product Name | V8 Pro VRF System |
| Capacity Range | 8–108HP combinable / 8–36HP individual unit |
| Cooling Capacity | 25.2–90kW (individual unit) |
| Heating Capacity | 27–100kW (individual unit) |
| SEER | 5.80–7.55 |
| SCOP | 4.25–4.48 |
| Max Connected Indoor Units | 64 units |
| Refrigerant | R410A |
| Power Supply | 380–415V / 3Ph / 50Hz |
| External Static Pressure | 0–120Pa adjustable |
| Combination Ratio | 50%–130% (up to 200% in specific conditions) |
| Low Ambient Heating | Stable operation in cold climate conditions |
Typical installations include mid-rise office buildings, hotels, serviced apartments, schools and outpatient clinics where the plant runs long hours and maintenance access is limited. Duty cycling means the facilities team can service one module during working hours while the others carry the load, avoiding weekend shutdowns.
The platform also suits staged developments. A first phase can be commissioned with two or three modules and the remaining capacity added later against the same pipework and control network, which keeps capital spending aligned with occupancy.
Modules are shipped upright on reinforced pallets with corner protectors, refrigerant service ports capped and sealed, and a wiring diagram plus commissioning checklist in each carton. Crates are sized for standard 20ft and 40ft containers with forklift access on all four sides.