logo
Products
PRODUCTS DETAILS
Home > Products >
Full DC Inverter VRF System 25-340kW Rotary 100 Indoor Units 1000m Piping

Full DC Inverter VRF System 25-340kW Rotary 100 Indoor Units 1000m Piping

MOQ: Negotiable
Price: Negotiable
Standard Packaging: Standard export packing
Delivery Period: Negotiable
Payment Method: TT
Supply Capacity: Negotiable
Detail Information
Place of Origin
China
Brand Name
Midea、Hongtai
Certification
CE, Eurovent
Model Number
HT-VRF rotary series
Product Name:
DC Inverter VRF System
Cooling Capacity:
25-340kW
Heating Capacity:
25-340kW
Compressor Type:
Rotary
Number Of Compressors:
1-2
Max Connectable Indoor Units:
100
Piping Length:
Up To 1000m
Max Elevation Difference:
110m
Refrigerant:
R410A
Power Supply:
3-phase, 380-415V, 50Hz
Highlight:

DC Inverter VRF 25-340kW

,

VRF system 100 indoor units

,

Rotary VRF 1000m piping

Product Description
Full DC Inverter VRF System Overview: 25–340kW Single Refrigerant Network

This full DC inverter VRF system covers the large system band from 25kW to 340kW within a single refrigerant network and connects up to 100 indoor units, making it the appropriate choice for buildings where a chiller would be oversized and a multi-split system unmanageable. One outdoor plant replaces a distributed set of small condensers, releasing facade space and converging maintenance on a single location.

Rotary compressors with DC inverter drive run the circuit, and a system uses one or two compressor modules depending on capacity. Inverter control holds evaporating and condensing pressure within a narrow band instead of swinging with on-off operation, so room temperature stays flat and the electrical demand curve is smoothed. The high COP of the platform converts directly into lower running cost for the owner.

Refrigerant piping extends to 1000m total length with a maximum elevation difference of 110m between the outdoor unit and the furthest indoor unit. That capability allows a single plant room to serve a multi-storey building including basements and roof-level mechanical spaces, and it removes the need for intermediate refrigerant risers that complicate both design and service.

The 3-stage backup function protects continuity of service. Module backup keeps the network alive if one outdoor module is isolated, compressor backup covers compressor failure within a module, and fan motor backup maintains heat rejection if a fan motor fails. Additional functions include all outdoor units cycling operation so that run hours equalise, and indoor and outdoor unit positioning, which sounds a buzzer on the addressed unit to speed up commissioning and fault finding.

Key Features of the DC Inverter VRF Platform
  • 25–340kW Single Network: replaces a chiller or many small splits with one centralised VRF plant.
  • 100 Connectable Indoor Units: covers large buildings with a single refrigerant and control system.
  • 1000m Piping and 110m Elevation: serves basements, roof plant and multi-storey risers from one plant room.
  • 3-Stage Backup Function: module, compressor and fan motor backup keep the system operational.
  • All Outdoor Units Cycle Operation: run hours equalise across modules, extending equipment lifespan.
  • Indoor and Outdoor Unit Positioning: built-in buzzer locates addressed units during commissioning and service.
Technical Specifications
Parameter Specification
Product NameDC Inverter VRF System
Cooling Capacity25–340kW
Heating Capacity25–340kW
Compressor TypeRotary
Number of Compressors1–2
Max Connectable Indoor Units100
Piping LengthUp to 1000m
Max Elevation Difference110m
Outdoor Unit TypesCompact, Modular
Control SystemCentralised control, individual control
RefrigerantR410A
Power Supply3-phase, 380–415V, 50Hz
Applications for Large-Scale VRF Installations

Office buildings, hotels, hospitals, shopping centres and mixed-use developments specify this capacity band when the design load sits between 25kW and 340kW. The 100 indoor unit connection limit allows a whole building to be served from one plant, with cassettes in public areas, ducted units in corridors and wall-mounted units in individual rooms.

Retrofit projects benefit from the 1000m piping allowance, because the new plant can be located where the old equipment stood while the existing ceiling and riser infrastructure is reused. Night mode reduces compressor and fan speed to lower noise by up to 10dB(A), which matters in residential neighbours of commercial buildings.

Packaging & Quality Assurance

Outdoor modules are fixed to plywood pallets with shock-absorbing blocks, refrigerant ports sealed and the coil face protected by a removable guard. Each carton includes a wiring diagram, refrigerant charge calculation sheet and installation manual, and units can be container-loaded upright with forklift access.

Products
PRODUCTS DETAILS
Full DC Inverter VRF System 25-340kW Rotary 100 Indoor Units 1000m Piping
MOQ: Negotiable
Price: Negotiable
Standard Packaging: Standard export packing
Delivery Period: Negotiable
Payment Method: TT
Supply Capacity: Negotiable
Detail Information
Place of Origin
China
Brand Name
Midea、Hongtai
Certification
CE, Eurovent
Model Number
HT-VRF rotary series
Product Name:
DC Inverter VRF System
Cooling Capacity:
25-340kW
Heating Capacity:
25-340kW
Compressor Type:
Rotary
Number Of Compressors:
1-2
Max Connectable Indoor Units:
100
Piping Length:
Up To 1000m
Max Elevation Difference:
110m
Refrigerant:
R410A
Power Supply:
3-phase, 380-415V, 50Hz
Minimum Order Quantity:
Negotiable
Price:
Negotiable
Packaging Details:
Standard export packing
Delivery Time:
Negotiable
Payment Terms:
TT
Supply Ability:
Negotiable
Highlight

DC Inverter VRF 25-340kW

,

VRF system 100 indoor units

,

Rotary VRF 1000m piping

Product Description
Full DC Inverter VRF System Overview: 25–340kW Single Refrigerant Network

This full DC inverter VRF system covers the large system band from 25kW to 340kW within a single refrigerant network and connects up to 100 indoor units, making it the appropriate choice for buildings where a chiller would be oversized and a multi-split system unmanageable. One outdoor plant replaces a distributed set of small condensers, releasing facade space and converging maintenance on a single location.

Rotary compressors with DC inverter drive run the circuit, and a system uses one or two compressor modules depending on capacity. Inverter control holds evaporating and condensing pressure within a narrow band instead of swinging with on-off operation, so room temperature stays flat and the electrical demand curve is smoothed. The high COP of the platform converts directly into lower running cost for the owner.

Refrigerant piping extends to 1000m total length with a maximum elevation difference of 110m between the outdoor unit and the furthest indoor unit. That capability allows a single plant room to serve a multi-storey building including basements and roof-level mechanical spaces, and it removes the need for intermediate refrigerant risers that complicate both design and service.

The 3-stage backup function protects continuity of service. Module backup keeps the network alive if one outdoor module is isolated, compressor backup covers compressor failure within a module, and fan motor backup maintains heat rejection if a fan motor fails. Additional functions include all outdoor units cycling operation so that run hours equalise, and indoor and outdoor unit positioning, which sounds a buzzer on the addressed unit to speed up commissioning and fault finding.

Key Features of the DC Inverter VRF Platform
  • 25–340kW Single Network: replaces a chiller or many small splits with one centralised VRF plant.
  • 100 Connectable Indoor Units: covers large buildings with a single refrigerant and control system.
  • 1000m Piping and 110m Elevation: serves basements, roof plant and multi-storey risers from one plant room.
  • 3-Stage Backup Function: module, compressor and fan motor backup keep the system operational.
  • All Outdoor Units Cycle Operation: run hours equalise across modules, extending equipment lifespan.
  • Indoor and Outdoor Unit Positioning: built-in buzzer locates addressed units during commissioning and service.
Technical Specifications
Parameter Specification
Product NameDC Inverter VRF System
Cooling Capacity25–340kW
Heating Capacity25–340kW
Compressor TypeRotary
Number of Compressors1–2
Max Connectable Indoor Units100
Piping LengthUp to 1000m
Max Elevation Difference110m
Outdoor Unit TypesCompact, Modular
Control SystemCentralised control, individual control
RefrigerantR410A
Power Supply3-phase, 380–415V, 50Hz
Applications for Large-Scale VRF Installations

Office buildings, hotels, hospitals, shopping centres and mixed-use developments specify this capacity band when the design load sits between 25kW and 340kW. The 100 indoor unit connection limit allows a whole building to be served from one plant, with cassettes in public areas, ducted units in corridors and wall-mounted units in individual rooms.

Retrofit projects benefit from the 1000m piping allowance, because the new plant can be located where the old equipment stood while the existing ceiling and riser infrastructure is reused. Night mode reduces compressor and fan speed to lower noise by up to 10dB(A), which matters in residential neighbours of commercial buildings.

Packaging & Quality Assurance

Outdoor modules are fixed to plywood pallets with shock-absorbing blocks, refrigerant ports sealed and the coil face protected by a removable guard. Each carton includes a wiring diagram, refrigerant charge calculation sheet and installation manual, and units can be container-loaded upright with forklift access.

Sitemap |  Privacy Policy | China Good Quality DC Inverter VRF Supplier. Copyright © 2024-2026 Henan Hongtai HVAC Equipment Co., Ltd. . All Rights Reserved.
+86 18703827920