Commercial projects rarely fail because of capacity; they fail because of coordination. This three phase DC inverter VRF air conditioning system is built around that reality. The 380-415V three phase supply, 25-340kW capacity range and 100 connectable indoor units give the consulting engineer a single refrigerant platform that can be scheduled early in the design process and still be trimmed to the final tenant layout months later.
All modulation happens on the refrigerant side. The outdoor unit adjusts compressor speed and fan speed together, which keeps condensing pressure stable when the ambient temperature climbs and keeps the suction pressure stable when only a handful of indoor units are running. Because the electrical demand follows the real load instead of the installed tonnage, the supply authority connection and the building transformer allowance are easier to justify in the electrical design report.
| Parameter | Specification |
|---|---|
| Cooling Capacity | 25-340kW |
| Heating Capacity | 25-340kW |
| Power Supply | 3-phase, 380-415V, 50Hz |
| Refrigerant | R410A |
| Compressor Type | Rotary |
| Number of Compressors | 1-2 |
| Max. Number of Connectable Indoor Units | 100 |
| Indoor Unit Types | Ceiling Cassette, Ducted, Floor Standing, Wall Mounted, Floor Ceiling |
Typical installations are commercial offices, banks, clinics, showrooms and mid size shopping centres where three phase power is already available at the roof plant area. Consulting engineers specify this arrangement when the tenant fit out is not yet frozen, because indoor units can be added or relocated inside the allowed connection ratio without touching the outdoor unit. Distribution warehouses with attached office pods, car showrooms with high glazing loads and restaurants with extract dominated kitchens also benefit from the fast reaction of inverter control when loads change abruptly during the day.
Units are delivered with lifting eyes, base rails and a nitrogen charge holding pressure that is verified before dispatch. Each consignment includes a packing list, wiring diagram, refrigerant charge table and commissioning sheet. Pipe kits, branch joints and communication cable are supplied as optional line items to match the bill of quantities. The factory performs a leak test, an electrical safety test and a functional run test on every unit, and quality records are retained for traceability. Standard sea worthy packing is used for container shipments, and export crating can be upgraded for long inland haulage on request.
For contractors, the advantage is predictable installation: one three phase feed, one communication bus and one commissioning routine regardless of the final room count. For owners, the advantage is a system that keeps working efficiently as the building changes hands or tenancies are subdivided.
| MOQ: | Negotiable |
| Price: | Negotiable |
| Standard Packaging: | Standard |
| Delivery Period: | Negotiable |
| Payment Method: | TT |
| Supply Capacity: | Negotiable |
Commercial projects rarely fail because of capacity; they fail because of coordination. This three phase DC inverter VRF air conditioning system is built around that reality. The 380-415V three phase supply, 25-340kW capacity range and 100 connectable indoor units give the consulting engineer a single refrigerant platform that can be scheduled early in the design process and still be trimmed to the final tenant layout months later.
All modulation happens on the refrigerant side. The outdoor unit adjusts compressor speed and fan speed together, which keeps condensing pressure stable when the ambient temperature climbs and keeps the suction pressure stable when only a handful of indoor units are running. Because the electrical demand follows the real load instead of the installed tonnage, the supply authority connection and the building transformer allowance are easier to justify in the electrical design report.
| Parameter | Specification |
|---|---|
| Cooling Capacity | 25-340kW |
| Heating Capacity | 25-340kW |
| Power Supply | 3-phase, 380-415V, 50Hz |
| Refrigerant | R410A |
| Compressor Type | Rotary |
| Number of Compressors | 1-2 |
| Max. Number of Connectable Indoor Units | 100 |
| Indoor Unit Types | Ceiling Cassette, Ducted, Floor Standing, Wall Mounted, Floor Ceiling |
Typical installations are commercial offices, banks, clinics, showrooms and mid size shopping centres where three phase power is already available at the roof plant area. Consulting engineers specify this arrangement when the tenant fit out is not yet frozen, because indoor units can be added or relocated inside the allowed connection ratio without touching the outdoor unit. Distribution warehouses with attached office pods, car showrooms with high glazing loads and restaurants with extract dominated kitchens also benefit from the fast reaction of inverter control when loads change abruptly during the day.
Units are delivered with lifting eyes, base rails and a nitrogen charge holding pressure that is verified before dispatch. Each consignment includes a packing list, wiring diagram, refrigerant charge table and commissioning sheet. Pipe kits, branch joints and communication cable are supplied as optional line items to match the bill of quantities. The factory performs a leak test, an electrical safety test and a functional run test on every unit, and quality records are retained for traceability. Standard sea worthy packing is used for container shipments, and export crating can be upgraded for long inland haulage on request.
For contractors, the advantage is predictable installation: one three phase feed, one communication bus and one commissioning routine regardless of the final room count. For owners, the advantage is a system that keeps working efficiently as the building changes hands or tenancies are subdivided.