R410A Full DC Inverter VRF Multi Split Unit 110m Elevation Difference High Rise Buildings

R410A Full DC Inverter VRF Multi Split Unit 110m Elevation Difference High Rise Buildings

MOQ: Negotiable
Price: Negotiable
Standard Packaging: Standard
Delivery Period: Negotiable
Payment Method: TT
Supply Capacity: Negotiable
Detail Information
Place of Origin
China
Brand Name
midea、Hongtai HVAC
Certification
CE, Eurovent
Cooling Capacity:
25-340kW
Heating Capacity:
25-340kW
Max. Elevation Difference:
110m
Refrigerant:
R410A
Compressor Type:
Rotary
Number Of Compressors:
1-2
Max. Number Of Connectable Indoor Units:
100
Power Supply:
3-phase, 380-415V, 50Hz
Highlight:

R410A DC Inverter VRF

,

VRF for high rise buildings

,

Multi split unit 110m elevation

Product Description
R410A Full DC Inverter VRF Multi Split Unit for High Rise Buildings

Tall buildings place unusual stress on a refrigerant system. Oil must return from the lowest indoor unit to a rooftop condensing unit dozens of floors above, while the liquid column has to remain stable in the opposite direction. This R410A full DC inverter VRF multi split unit is engineered for that exact duty, with a maximum elevation difference of 110 metres between the outdoor unit and the furthest indoor unit — enough for a building of roughly thirty storeys with the plant room on the roof.

Balancing is handled electronically. The outdoor unit monitors pressure at each branch and adjusts the electronic expansion valves, so indoor units on the top floor and indoor units in the basement receive the same evaporating condition even though the static head is completely different. Capacity covers the 25kW to 340kW range, with up to 100 indoor units connected to a single unit.

Key Features of the High Rise VRF System
  • 110m Elevation Difference: Refrigerant lines can travel the full height of a high rise building from a single rooftop plant area, avoiding intermediate plant rooms that would consume lettable area.
  • Oil Return Management: An integrated oil return cycle and dedicated separation technology keep the compressor lubricated even when the riser is long and some indoor units operate very rarely.
  • Electronic Branch Balancing: Expansion valves adjust continuously to compensate for the static head of the riser, so capacity is not concentrated on the lower floors.
  • Long Total Pipe Length: The system supports the long total piping lengths demanded by large floor plates, allowing the condensing unit position to be chosen for maintenance access rather than proximity.
  • Full DC Inverter Control: Compressor, fan and expansion components are inverter driven for stable control across a wide load range.
  • R410A Refrigerant: Compact pipe diameters simplify the riser design and reduce the structural load of pipework in existing shafts.
Technical Specifications
Parameter Specification
Cooling Capacity 25–340kW
Heating Capacity 25–340kW
Max. Elevation Difference 110m
Refrigerant R410A
Compressor Type Rotary
Number of Compressors 1–2
Max. Number of Connectable Indoor Units 100
Power Supply 3-phase, 380–415V, 50Hz
Applications for VRF Multi Split Systems

This configuration is used in office towers, high rise residential developments, hotel towers and mixed use projects where the plant has to be concentrated at roof level for access and noise reasons. It is equally useful in basement plant rooms serving above ground floors, because the elevation margin in both directions is generous. Retrofit projects in existing towers benefit from the compact pipe envelope, which often allows the new system to be pulled through shafts that were originally sized for a different refrigerant.

Packaging & Quality Assurance

Riser components are packed separately from the outdoor unit so that site teams can stage materials by floor. Branch joints, refnet headers, insulation and communication cable are supplied as a coordinated kit with a joint numbering plan that matches the riser drawing. Outdoor units travel on a steel framed pallet suitable for crane lifting onto a roof slab. Each consignment includes an oil balance commissioning procedure, a riser pressure calculation sheet and a wiring diagram with valve addresses pre-assigned.

Designers choose this platform when the building geometry makes a chilled water plant impractical, and when the client wants a system that can be commissioned floor by floor as the building becomes occupied rather than in a single pass at the end of construction.

Products
PRODUCTS DETAILS
R410A Full DC Inverter VRF Multi Split Unit 110m Elevation Difference High Rise Buildings
MOQ: Negotiable
Price: Negotiable
Standard Packaging: Standard
Delivery Period: Negotiable
Payment Method: TT
Supply Capacity: Negotiable
Detail Information
Place of Origin
China
Brand Name
midea、Hongtai HVAC
Certification
CE, Eurovent
Cooling Capacity:
25-340kW
Heating Capacity:
25-340kW
Max. Elevation Difference:
110m
Refrigerant:
R410A
Compressor Type:
Rotary
Number Of Compressors:
1-2
Max. Number Of Connectable Indoor Units:
100
Power Supply:
3-phase, 380-415V, 50Hz
Minimum Order Quantity:
Negotiable
Price:
Negotiable
Packaging Details:
Standard
Delivery Time:
Negotiable
Payment Terms:
TT
Supply Ability:
Negotiable
Highlight

R410A DC Inverter VRF

,

VRF for high rise buildings

,

Multi split unit 110m elevation

Product Description
R410A Full DC Inverter VRF Multi Split Unit for High Rise Buildings

Tall buildings place unusual stress on a refrigerant system. Oil must return from the lowest indoor unit to a rooftop condensing unit dozens of floors above, while the liquid column has to remain stable in the opposite direction. This R410A full DC inverter VRF multi split unit is engineered for that exact duty, with a maximum elevation difference of 110 metres between the outdoor unit and the furthest indoor unit — enough for a building of roughly thirty storeys with the plant room on the roof.

Balancing is handled electronically. The outdoor unit monitors pressure at each branch and adjusts the electronic expansion valves, so indoor units on the top floor and indoor units in the basement receive the same evaporating condition even though the static head is completely different. Capacity covers the 25kW to 340kW range, with up to 100 indoor units connected to a single unit.

Key Features of the High Rise VRF System
  • 110m Elevation Difference: Refrigerant lines can travel the full height of a high rise building from a single rooftop plant area, avoiding intermediate plant rooms that would consume lettable area.
  • Oil Return Management: An integrated oil return cycle and dedicated separation technology keep the compressor lubricated even when the riser is long and some indoor units operate very rarely.
  • Electronic Branch Balancing: Expansion valves adjust continuously to compensate for the static head of the riser, so capacity is not concentrated on the lower floors.
  • Long Total Pipe Length: The system supports the long total piping lengths demanded by large floor plates, allowing the condensing unit position to be chosen for maintenance access rather than proximity.
  • Full DC Inverter Control: Compressor, fan and expansion components are inverter driven for stable control across a wide load range.
  • R410A Refrigerant: Compact pipe diameters simplify the riser design and reduce the structural load of pipework in existing shafts.
Technical Specifications
Parameter Specification
Cooling Capacity 25–340kW
Heating Capacity 25–340kW
Max. Elevation Difference 110m
Refrigerant R410A
Compressor Type Rotary
Number of Compressors 1–2
Max. Number of Connectable Indoor Units 100
Power Supply 3-phase, 380–415V, 50Hz
Applications for VRF Multi Split Systems

This configuration is used in office towers, high rise residential developments, hotel towers and mixed use projects where the plant has to be concentrated at roof level for access and noise reasons. It is equally useful in basement plant rooms serving above ground floors, because the elevation margin in both directions is generous. Retrofit projects in existing towers benefit from the compact pipe envelope, which often allows the new system to be pulled through shafts that were originally sized for a different refrigerant.

Packaging & Quality Assurance

Riser components are packed separately from the outdoor unit so that site teams can stage materials by floor. Branch joints, refnet headers, insulation and communication cable are supplied as a coordinated kit with a joint numbering plan that matches the riser drawing. Outdoor units travel on a steel framed pallet suitable for crane lifting onto a roof slab. Each consignment includes an oil balance commissioning procedure, a riser pressure calculation sheet and a wiring diagram with valve addresses pre-assigned.

Designers choose this platform when the building geometry makes a chilled water plant impractical, and when the client wants a system that can be commissioned floor by floor as the building becomes occupied rather than in a single pass at the end of construction.