Tall buildings place unusual stress on a refrigerant system. Oil must return from the lowest indoor unit to a rooftop condensing unit dozens of floors above, while the liquid column has to remain stable in the opposite direction. This R410A full DC inverter VRF multi split unit is engineered for that exact duty, with a maximum elevation difference of 110 metres between the outdoor unit and the furthest indoor unit — enough for a building of roughly thirty storeys with the plant room on the roof.
Balancing is handled electronically. The outdoor unit monitors pressure at each branch and adjusts the electronic expansion valves, so indoor units on the top floor and indoor units in the basement receive the same evaporating condition even though the static head is completely different. Capacity covers the 25kW to 340kW range, with up to 100 indoor units connected to a single unit.
| Parameter | Specification |
|---|---|
| Cooling Capacity | 25–340kW |
| Heating Capacity | 25–340kW |
| Max. Elevation Difference | 110m |
| Refrigerant | R410A |
| Compressor Type | Rotary |
| Number of Compressors | 1–2 |
| Max. Number of Connectable Indoor Units | 100 |
| Power Supply | 3-phase, 380–415V, 50Hz |
This configuration is used in office towers, high rise residential developments, hotel towers and mixed use projects where the plant has to be concentrated at roof level for access and noise reasons. It is equally useful in basement plant rooms serving above ground floors, because the elevation margin in both directions is generous. Retrofit projects in existing towers benefit from the compact pipe envelope, which often allows the new system to be pulled through shafts that were originally sized for a different refrigerant.
Riser components are packed separately from the outdoor unit so that site teams can stage materials by floor. Branch joints, refnet headers, insulation and communication cable are supplied as a coordinated kit with a joint numbering plan that matches the riser drawing. Outdoor units travel on a steel framed pallet suitable for crane lifting onto a roof slab. Each consignment includes an oil balance commissioning procedure, a riser pressure calculation sheet and a wiring diagram with valve addresses pre-assigned.
Designers choose this platform when the building geometry makes a chilled water plant impractical, and when the client wants a system that can be commissioned floor by floor as the building becomes occupied rather than in a single pass at the end of construction.
| MOQ: | Negotiable |
| Price: | Negotiable |
| Standard Packaging: | Standard |
| Delivery Period: | Negotiable |
| Payment Method: | TT |
| Supply Capacity: | Negotiable |
Tall buildings place unusual stress on a refrigerant system. Oil must return from the lowest indoor unit to a rooftop condensing unit dozens of floors above, while the liquid column has to remain stable in the opposite direction. This R410A full DC inverter VRF multi split unit is engineered for that exact duty, with a maximum elevation difference of 110 metres between the outdoor unit and the furthest indoor unit — enough for a building of roughly thirty storeys with the plant room on the roof.
Balancing is handled electronically. The outdoor unit monitors pressure at each branch and adjusts the electronic expansion valves, so indoor units on the top floor and indoor units in the basement receive the same evaporating condition even though the static head is completely different. Capacity covers the 25kW to 340kW range, with up to 100 indoor units connected to a single unit.
| Parameter | Specification |
|---|---|
| Cooling Capacity | 25–340kW |
| Heating Capacity | 25–340kW |
| Max. Elevation Difference | 110m |
| Refrigerant | R410A |
| Compressor Type | Rotary |
| Number of Compressors | 1–2 |
| Max. Number of Connectable Indoor Units | 100 |
| Power Supply | 3-phase, 380–415V, 50Hz |
This configuration is used in office towers, high rise residential developments, hotel towers and mixed use projects where the plant has to be concentrated at roof level for access and noise reasons. It is equally useful in basement plant rooms serving above ground floors, because the elevation margin in both directions is generous. Retrofit projects in existing towers benefit from the compact pipe envelope, which often allows the new system to be pulled through shafts that were originally sized for a different refrigerant.
Riser components are packed separately from the outdoor unit so that site teams can stage materials by floor. Branch joints, refnet headers, insulation and communication cable are supplied as a coordinated kit with a joint numbering plan that matches the riser drawing. Outdoor units travel on a steel framed pallet suitable for crane lifting onto a roof slab. Each consignment includes an oil balance commissioning procedure, a riser pressure calculation sheet and a wiring diagram with valve addresses pre-assigned.
Designers choose this platform when the building geometry makes a chilled water plant impractical, and when the client wants a system that can be commissioned floor by floor as the building becomes occupied rather than in a single pass at the end of construction.