A modular DC inverter VRF system treats the rooftop plant as a small fleet of identical outdoor units rather than a single machine. This approach matters when a building is completed in phases, when a developer wants to defer capital expenditure until a tenant signs, or when the roof slab is only accessible through a narrow service lift. Each module can be lifted, commissioned and put into service independently, and additional modules can be added later on the same refrigerant and communication network.
Each module uses full DC inverter control with rotary compressors, R410A refrigerant and a 25kW to 340kW combined capacity window across the modular range, addressing up to 100 indoor units in total. Because capacity is added in steps, the operating modules can be concentrated around the actual load, which keeps part load efficiency high in buildings that fill up over several years.
| Parameter | Specification |
|---|---|
| Cooling Capacity | 25–340kW |
| Heating Capacity | 25–340kW |
| Compressor Type | Rotary |
| Refrigerant | R410A |
| Number of Compressors | 1–2 |
| Max. Number of Connectable Indoor Units | 100 |
| Indoor Unit Types | Ceiling Cassette, Ducted, Floor Standing, Wall Mounted, Floor Ceiling |
| Power Supply | 3-phase, 380–415V, 50Hz |
Modular configurations are usually chosen for speculative office developments, phased residential projects, retail parks and educational campuses where buildings are added over time. The approach also fits renovation work in occupied buildings, because one module can be installed and connected while the rest of the building continues to operate on the existing plant. Buildings with a highly variable occupancy pattern, such as conference centres and training facilities, gain from being able to run a small number of modules at efficient part load outside event days.
Each module is packed in its own crate with independent lifting points, a moisture barrier and a shock indicator. The internal piping of modules is tested at the factory and the interconnecting pipe kits are supplied in a matched set with a joint numbering plan. Commissioning documentation covers module address setting, capacity staging and the load sharing sequence, so the building operator understands which module runs first and why. Factory test reports and refrigerant charge records are included with every shipment.
For a developer the appeal is financial control: plant is purchased when it is needed, not at practical completion. For the operator the appeal is resilience, because the failure of one module reduces capacity rather than shutting the building down.
| MOQ: | Negotiable |
| Price: | Negotiable |
| Standard Packaging: | Standard |
| Delivery Period: | Negotiable |
| Payment Method: | TT |
| Supply Capacity: | Negotiable |
A modular DC inverter VRF system treats the rooftop plant as a small fleet of identical outdoor units rather than a single machine. This approach matters when a building is completed in phases, when a developer wants to defer capital expenditure until a tenant signs, or when the roof slab is only accessible through a narrow service lift. Each module can be lifted, commissioned and put into service independently, and additional modules can be added later on the same refrigerant and communication network.
Each module uses full DC inverter control with rotary compressors, R410A refrigerant and a 25kW to 340kW combined capacity window across the modular range, addressing up to 100 indoor units in total. Because capacity is added in steps, the operating modules can be concentrated around the actual load, which keeps part load efficiency high in buildings that fill up over several years.
| Parameter | Specification |
|---|---|
| Cooling Capacity | 25–340kW |
| Heating Capacity | 25–340kW |
| Compressor Type | Rotary |
| Refrigerant | R410A |
| Number of Compressors | 1–2 |
| Max. Number of Connectable Indoor Units | 100 |
| Indoor Unit Types | Ceiling Cassette, Ducted, Floor Standing, Wall Mounted, Floor Ceiling |
| Power Supply | 3-phase, 380–415V, 50Hz |
Modular configurations are usually chosen for speculative office developments, phased residential projects, retail parks and educational campuses where buildings are added over time. The approach also fits renovation work in occupied buildings, because one module can be installed and connected while the rest of the building continues to operate on the existing plant. Buildings with a highly variable occupancy pattern, such as conference centres and training facilities, gain from being able to run a small number of modules at efficient part load outside event days.
Each module is packed in its own crate with independent lifting points, a moisture barrier and a shock indicator. The internal piping of modules is tested at the factory and the interconnecting pipe kits are supplied in a matched set with a joint numbering plan. Commissioning documentation covers module address setting, capacity staging and the load sharing sequence, so the building operator understands which module runs first and why. Factory test reports and refrigerant charge records are included with every shipment.
For a developer the appeal is financial control: plant is purchased when it is needed, not at practical completion. For the operator the appeal is resilience, because the failure of one module reduces capacity rather than shutting the building down.