| MOQ: | Negotiable |
| Price: | Negotiable |
| Standard Packaging: | Standard |
| Delivery Period: | Negotiable |
| Payment Method: | TT |
| Supply Capacity: | Negotiable |
Projects in the Gulf and other 60Hz markets cannot simply reuse a 50Hz specification. Compressor speed, fan motor windings, control logic and protection thresholds must all be matched to a 60Hz supply, and cooling duty has to hold up when rooftop ambient temperatures far exceed temperate-climate design assumptions. This 60Hz DC inverter VRF air conditioner is configured for that environment, with a 25kW to 340kW capacity window and support for up to 100 connected indoor units.
Protection logic is written for sustained high-ambient operation. The outdoor fan modulates with condenser pressure, and the inverter limits compressor speed only when pressure approaches the upper boundary — so capacity is preserved as long as possible instead of being cut early. Combined with R410A refrigerant and a generously sized coil, the unit maintains stable condensing conditions through the hottest part of the day.
| Cooling Capacity | 25–340kW |
|---|---|
| Heating Capacity | 25–340kW |
| Power Supply | 3-phase, 380–415V, 60Hz |
| Refrigerant | R410A |
| Compressor Type | Rotary |
| Max. Number of Connectable Indoor Units | 100 |
| Indoor Unit Types | Ceiling Cassette, Ducted, Floor Standing, Wall Mounted, Floor Ceiling |
| Place of Origin | China |
This configuration is prepared for commercial buildings, staff accommodation blocks, schools, clinics and retail developments in 60Hz markets where the cooling season dominates the operating year. Long horizontal pipe runs are typical in low-rise developments with a central plant area, and the compact R410A pipe envelope keeps those runs manageable. In projects with a mix of accommodation and public space, the same outdoor unit can serve ducted units in corridors, cassettes in public rooms and wall-mounted units in smaller bedrooms.
Units are packed for sea freight with a sealed electrical enclosure, desiccant and corner protection, and the packing is rated for the container dwell time typical of regional logistics. Each shipment includes a 60Hz-specific wiring diagram, a protection parameter table and a commissioning record. Coil cleaning instructions are provided in English and Arabic on request, and a scheduled maintenance kit with coil cleaner, filter spares and fan motor brushes can be added to the order.
Contractors appreciate receiving a unit that is already set up for the local supply frequency, since site modifications are the most common cause of warranty disputes. Owners appreciate a system that keeps cooling through the peak of the day without resorting to oversized plant.
| MOQ: | Negotiable |
| Price: | Negotiable |
| Standard Packaging: | Standard |
| Delivery Period: | Negotiable |
| Payment Method: | TT |
| Supply Capacity: | Negotiable |
Projects in the Gulf and other 60Hz markets cannot simply reuse a 50Hz specification. Compressor speed, fan motor windings, control logic and protection thresholds must all be matched to a 60Hz supply, and cooling duty has to hold up when rooftop ambient temperatures far exceed temperate-climate design assumptions. This 60Hz DC inverter VRF air conditioner is configured for that environment, with a 25kW to 340kW capacity window and support for up to 100 connected indoor units.
Protection logic is written for sustained high-ambient operation. The outdoor fan modulates with condenser pressure, and the inverter limits compressor speed only when pressure approaches the upper boundary — so capacity is preserved as long as possible instead of being cut early. Combined with R410A refrigerant and a generously sized coil, the unit maintains stable condensing conditions through the hottest part of the day.
| Cooling Capacity | 25–340kW |
|---|---|
| Heating Capacity | 25–340kW |
| Power Supply | 3-phase, 380–415V, 60Hz |
| Refrigerant | R410A |
| Compressor Type | Rotary |
| Max. Number of Connectable Indoor Units | 100 |
| Indoor Unit Types | Ceiling Cassette, Ducted, Floor Standing, Wall Mounted, Floor Ceiling |
| Place of Origin | China |
This configuration is prepared for commercial buildings, staff accommodation blocks, schools, clinics and retail developments in 60Hz markets where the cooling season dominates the operating year. Long horizontal pipe runs are typical in low-rise developments with a central plant area, and the compact R410A pipe envelope keeps those runs manageable. In projects with a mix of accommodation and public space, the same outdoor unit can serve ducted units in corridors, cassettes in public rooms and wall-mounted units in smaller bedrooms.
Units are packed for sea freight with a sealed electrical enclosure, desiccant and corner protection, and the packing is rated for the container dwell time typical of regional logistics. Each shipment includes a 60Hz-specific wiring diagram, a protection parameter table and a commissioning record. Coil cleaning instructions are provided in English and Arabic on request, and a scheduled maintenance kit with coil cleaner, filter spares and fan motor brushes can be added to the order.
Contractors appreciate receiving a unit that is already set up for the local supply frequency, since site modifications are the most common cause of warranty disputes. Owners appreciate a system that keeps cooling through the peak of the day without resorting to oversized plant.