Ceiling voids are shrinking. Lighting tracks, sprinkler mains, cable trays and fire dampers all compete for the same two hundred millimetres above the ceiling line, and in many refurbishments the residual space will not accept a conventional cassette body. This one way cassette fan coil unit addresses that reality with a body only 153 millimetres deep, allowing it to sit in a shallow ceiling zone while still delivering air in a single controlled direction along the room.
Because the discharge is one directional, the unit is normally positioned along the perimeter wall or above the window line, where the air stream can blanket the glazing and intercept the solar gain before it reaches the occupants. That placement reduces draught complaints compared with a four way cassette mounted in the middle of a narrow room, and it keeps the ceiling visually clean because the panel reads as a slim linear slot rather than a large square grille.
| Parameter | Specification |
|---|---|
| Air Flow | 250–600 CFM |
| Cooling Capacity | 1.94–4.61 kW |
| Heating Capacity | 2.34–4.55 kW |
| Unit Height | 153 mm |
| Power Supply | 220–240V / 1Ph / 50Hz |
| Number of Fan Speeds | 3 |
| Coil Type | Copper Tube and Aluminum Fin |
| Sound Level | 23–52 dB(A) |
Single direction cassettes are chosen for hotel guest room entries, corridors, small offices, treatment rooms and retail units with narrow floor plates where a four way cassette would blow directly onto staff or customers. They are also used above full height glazing in atrium and lobby areas where the air stream has to protect the glass from condensation. In residential projects the unit suits bedrooms and study rooms where the ceiling void is limited and the owner wants a discreet linear diffuser appearance.
The panel and the chassis are packed in separate cartons so that the chassis can be installed and pressure tested before the finished ceiling is closed. Coil connections are sealed with plastic caps and the drain outlet is protected by a plug. Each unit carries a factory test label with the tested airflow and static pressure, and the shipment includes a panel cut out template to help the ceiling contractor set out the opening accurately.
Where a standard cassette simply does not fit, the alternative is usually a ducted unit with a separate grille, which costs more in materials and installation time. This unit closes that gap with a one piece solution that still looks like a designed ceiling element.
| MOQ: | Negotiable |
| Price: | Negotiable |
| Standard Packaging: | Standard |
| Delivery Period: | Negotiable |
| Payment Method: | TT |
| Supply Capacity: | Negotiable |
Ceiling voids are shrinking. Lighting tracks, sprinkler mains, cable trays and fire dampers all compete for the same two hundred millimetres above the ceiling line, and in many refurbishments the residual space will not accept a conventional cassette body. This one way cassette fan coil unit addresses that reality with a body only 153 millimetres deep, allowing it to sit in a shallow ceiling zone while still delivering air in a single controlled direction along the room.
Because the discharge is one directional, the unit is normally positioned along the perimeter wall or above the window line, where the air stream can blanket the glazing and intercept the solar gain before it reaches the occupants. That placement reduces draught complaints compared with a four way cassette mounted in the middle of a narrow room, and it keeps the ceiling visually clean because the panel reads as a slim linear slot rather than a large square grille.
| Parameter | Specification |
|---|---|
| Air Flow | 250–600 CFM |
| Cooling Capacity | 1.94–4.61 kW |
| Heating Capacity | 2.34–4.55 kW |
| Unit Height | 153 mm |
| Power Supply | 220–240V / 1Ph / 50Hz |
| Number of Fan Speeds | 3 |
| Coil Type | Copper Tube and Aluminum Fin |
| Sound Level | 23–52 dB(A) |
Single direction cassettes are chosen for hotel guest room entries, corridors, small offices, treatment rooms and retail units with narrow floor plates where a four way cassette would blow directly onto staff or customers. They are also used above full height glazing in atrium and lobby areas where the air stream has to protect the glass from condensation. In residential projects the unit suits bedrooms and study rooms where the ceiling void is limited and the owner wants a discreet linear diffuser appearance.
The panel and the chassis are packed in separate cartons so that the chassis can be installed and pressure tested before the finished ceiling is closed. Coil connections are sealed with plastic caps and the drain outlet is protected by a plug. Each unit carries a factory test label with the tested airflow and static pressure, and the shipment includes a panel cut out template to help the ceiling contractor set out the opening accurately.
Where a standard cassette simply does not fit, the alternative is usually a ducted unit with a separate grille, which costs more in materials and installation time. This unit closes that gap with a one piece solution that still looks like a designed ceiling element.