| MOQ: | Negotiable |
| Price: | Negotiable |
| Standard Packaging: | Standard |
| Delivery Period: | Negotiable |
| Payment Method: | TT |
| Supply Capacity: | Negotiable |
Compact does not have to mean compromised. This four way cassette fan coil unit uses a shortened chassis and a tighter fan deck so the body fits into ceiling zones where a full size cassette would clash with beams or duct risers, while keeping the four sided air distribution that makes cassette units so effective in square rooms. The airflow range runs from 250 to 600 CFM, covering small offices and meeting rooms up to larger open bays.
The hydronic coil is built from copper tubes mechanically expanded into aluminium fins, with hydrophilic fin treatment on the air side. That combination gives predictable heat transfer at low water temperatures, which matters in projects connected to a heat pump or a low temperature chiller where the supply water is not as cold as a traditional chiller plant would provide. Three fan speeds allow the installer to trade air movement against sound level in each room.
| Parameter | Specification |
|---|---|
| Air Flow | 250-600 CFM |
| Cooling Capacity | 1.58-8.25 kW |
| Heating Capacity | 1.77-8.50 kW |
| Coil Type | Copper Tube And Aluminum Fin |
| Coil Configuration | 3-row / 4-row |
| Power Supply | 220-240V/1Ph/50Hz |
| Number of Fan Speeds | 3 |
| Water Connection | G1/2 - G3/4 inch |
The compact cassette is specified for cellular offices, hotel meeting rooms, clinic examination rooms, small shops and apartments where the ceiling zone is tight but the room still needs an even, four sided air pattern. It is also a good fit for corridors that widen into a lobby, because the four way discharge avoids the dead spots that a single directional unit creates in an L shaped space. Projects using low temperature hydronic systems, such as air source heat pump installations, benefit from the coil geometry.
Units are packed with the panel in a separate carton and the coil face protected by a removable shield. Water connections are capped and the drain pan is supplied with a protective insert that must be removed before commissioning. Each carton carries a unit label with the tested airflow, cooling capacity and coil row configuration, so the site team can match the unit to the schedule without opening the panel.
The value of this model is coordination. A compact cassette that still performs like a full size unit reduces the number of clashes found during ceiling coordination, which is where most of the delay in a fit out programme actually comes from.
| MOQ: | Negotiable |
| Price: | Negotiable |
| Standard Packaging: | Standard |
| Delivery Period: | Negotiable |
| Payment Method: | TT |
| Supply Capacity: | Negotiable |
Compact does not have to mean compromised. This four way cassette fan coil unit uses a shortened chassis and a tighter fan deck so the body fits into ceiling zones where a full size cassette would clash with beams or duct risers, while keeping the four sided air distribution that makes cassette units so effective in square rooms. The airflow range runs from 250 to 600 CFM, covering small offices and meeting rooms up to larger open bays.
The hydronic coil is built from copper tubes mechanically expanded into aluminium fins, with hydrophilic fin treatment on the air side. That combination gives predictable heat transfer at low water temperatures, which matters in projects connected to a heat pump or a low temperature chiller where the supply water is not as cold as a traditional chiller plant would provide. Three fan speeds allow the installer to trade air movement against sound level in each room.
| Parameter | Specification |
|---|---|
| Air Flow | 250-600 CFM |
| Cooling Capacity | 1.58-8.25 kW |
| Heating Capacity | 1.77-8.50 kW |
| Coil Type | Copper Tube And Aluminum Fin |
| Coil Configuration | 3-row / 4-row |
| Power Supply | 220-240V/1Ph/50Hz |
| Number of Fan Speeds | 3 |
| Water Connection | G1/2 - G3/4 inch |
The compact cassette is specified for cellular offices, hotel meeting rooms, clinic examination rooms, small shops and apartments where the ceiling zone is tight but the room still needs an even, four sided air pattern. It is also a good fit for corridors that widen into a lobby, because the four way discharge avoids the dead spots that a single directional unit creates in an L shaped space. Projects using low temperature hydronic systems, such as air source heat pump installations, benefit from the coil geometry.
Units are packed with the panel in a separate carton and the coil face protected by a removable shield. Water connections are capped and the drain pan is supplied with a protective insert that must be removed before commissioning. Each carton carries a unit label with the tested airflow, cooling capacity and coil row configuration, so the site team can match the unit to the schedule without opening the panel.
The value of this model is coordination. A compact cassette that still performs like a full size unit reduces the number of clashes found during ceiling coordination, which is where most of the delay in a fit out programme actually comes from.