Concealed duct fan coil units are the workhorse of commercial fit-outs. Installed above the ceiling and out of sight, they connect to a duct network that delivers air through diffusers positioned where the room actually needs it. This horizontal model covers 200 to 1400 CFM with an external static pressure range of 12 to 50 Pascals — enough for a short distribution run with two or three diffusers and a return plenum without resorting to a larger, noisier cabinet.
Because the terminal is invisible, the design effort moves into the duct layout, and that is where this unit earns its keep. The discharge spigot is positioned to suit a straight run, the return is sized for a filter plenum, and the fan curve is published so the consultant can verify the operating point rather than guessing at it. The result is a system that meets the design airflow at the diffuser instead of falling short because the static pressure was underestimated.
| Parameter | Specification |
|---|---|
| Air Flow | 200–1400 CFM |
| External Static Pressure | 12–50 Pa |
| Cooling Capacity | 1.58–8.25 kW |
| Heating Capacity | 1.77–8.50 kW |
| Power Supply | 220–240V / 1Ph / 50Hz |
| Coil Type | Copper Tube and Aluminum Fin |
| Return Air Plenum | Optional |
| Sound Level | 28–50 dB(A) |
Ducted units are used wherever the air terminal should not be visible: hotel corridors, office suites, retail back-of-house, clinic corridors, and classroom blocks with a central ceiling void. They are also the practical solution for long narrow rooms where a cassette would not throw far enough, and for spaces with a bulkhead or a perimeter trough that can hide the unit but not a cassette panel. Because the discharge can be split, one unit can serve two adjacent rooms with independent diffusers.
Units are shipped with the fan deck locked, coil faces protected, and spigots capped to keep debris out during construction. Optional plenums and filters are packed as matched accessories in the same shipment so the installer does not have to fabricate a return box on site. A fan curve and a static pressure table are supplied with each unit, and the commissioning sheet records the measured airflow at each diffuser for the handover file.
The measurable benefit is fewer call-backs. When the static pressure is published and the coil is matched to the airflow, the system commissioned on site behaves as designed instead of being throttled to compensate for a mismatch.
| MOQ: | Negotiable |
| Price: | Negotiable |
| Standard Packaging: | Standard |
| Delivery Period: | Negotiable |
| Payment Method: | TT |
| Supply Capacity: | Negotiable |
Concealed duct fan coil units are the workhorse of commercial fit-outs. Installed above the ceiling and out of sight, they connect to a duct network that delivers air through diffusers positioned where the room actually needs it. This horizontal model covers 200 to 1400 CFM with an external static pressure range of 12 to 50 Pascals — enough for a short distribution run with two or three diffusers and a return plenum without resorting to a larger, noisier cabinet.
Because the terminal is invisible, the design effort moves into the duct layout, and that is where this unit earns its keep. The discharge spigot is positioned to suit a straight run, the return is sized for a filter plenum, and the fan curve is published so the consultant can verify the operating point rather than guessing at it. The result is a system that meets the design airflow at the diffuser instead of falling short because the static pressure was underestimated.
| Parameter | Specification |
|---|---|
| Air Flow | 200–1400 CFM |
| External Static Pressure | 12–50 Pa |
| Cooling Capacity | 1.58–8.25 kW |
| Heating Capacity | 1.77–8.50 kW |
| Power Supply | 220–240V / 1Ph / 50Hz |
| Coil Type | Copper Tube and Aluminum Fin |
| Return Air Plenum | Optional |
| Sound Level | 28–50 dB(A) |
Ducted units are used wherever the air terminal should not be visible: hotel corridors, office suites, retail back-of-house, clinic corridors, and classroom blocks with a central ceiling void. They are also the practical solution for long narrow rooms where a cassette would not throw far enough, and for spaces with a bulkhead or a perimeter trough that can hide the unit but not a cassette panel. Because the discharge can be split, one unit can serve two adjacent rooms with independent diffusers.
Units are shipped with the fan deck locked, coil faces protected, and spigots capped to keep debris out during construction. Optional plenums and filters are packed as matched accessories in the same shipment so the installer does not have to fabricate a return box on site. A fan curve and a static pressure table are supplied with each unit, and the commissioning sheet records the measured airflow at each diffuser for the handover file.
The measurable benefit is fewer call-backs. When the static pressure is published and the coil is matched to the airflow, the system commissioned on site behaves as designed instead of being throttled to compensate for a mismatch.