When the diffuser is far from the plant area, a low static pressure unit will not deliver. This medium static pressure duct fan coil covers 70 to 100 Pascals of external static pressure — enough for a longer distribution run, a sound attenuator and a return plenum with a filter, while staying within a chassis size that still fits a normal ceiling void. It is the middle ground between a short-run concealed unit and a full high static ducted machine.
The coil is a copper tube and aluminium fin assembly with hydrophilic treatment, matched to the airflow so that the leaving air temperature stays consistent across the face of the coil. At medium static pressure the fan runs at a higher speed than a low pressure unit, so the casing is stiffened and the fan is balanced to keep vibration and structure-borne noise under control — an important detail when the unit sits above a meeting room.
| Parameter | Specification |
|---|---|
| Static Pressure | 70–100 Pa |
| Air Flow | 300–1500 CFM |
| Cooling Capacity | 2.35–13.0 kW |
| Heating Capacity | 3.90–22.17 kW |
| Power Supply | 220–240V / 1Ph / 50Hz |
| Coil Type | Copper Tube and Aluminum Fin |
| Number of Fan Speeds | 3 |
| Sound Level | 35–61 dB(A) |
Medium static pressure units are specified for hotel corridor systems, office floors with a central plant room, lecture theatres with a rear plant zone, and retail units where the diffusers sit well away from the ceiling void over the unit. They also suit schools and clinics where a filtered return is required and the filter box adds resistance that a low pressure unit could not overcome. In renovation work they can often reuse an existing duct layout that was designed for a higher pressure machine.
Fan decks are locked for transport and the coil face is protected by a rigid shield. Duct spigots are capped and the drain outlet is plugged. Optional attenuators, plenums and filters are supplied as matched accessories. Each unit is supplied with a static pressure table and a commissioning record form, so the balancing engineer can document the measured airflow and the fan speed setting used at handover.
The practical argument for specifying the correct static pressure is energy and acoustics. A unit running at the right point on its curve uses less fan power and produces less noise than one pushed beyond its design range to reach a distant diffuser.
| MOQ: | Negotiable |
| Price: | Negotiable |
| Standard Packaging: | Standard |
| Delivery Period: | Negotiable |
| Payment Method: | TT |
| Supply Capacity: | Negotiable |
When the diffuser is far from the plant area, a low static pressure unit will not deliver. This medium static pressure duct fan coil covers 70 to 100 Pascals of external static pressure — enough for a longer distribution run, a sound attenuator and a return plenum with a filter, while staying within a chassis size that still fits a normal ceiling void. It is the middle ground between a short-run concealed unit and a full high static ducted machine.
The coil is a copper tube and aluminium fin assembly with hydrophilic treatment, matched to the airflow so that the leaving air temperature stays consistent across the face of the coil. At medium static pressure the fan runs at a higher speed than a low pressure unit, so the casing is stiffened and the fan is balanced to keep vibration and structure-borne noise under control — an important detail when the unit sits above a meeting room.
| Parameter | Specification |
|---|---|
| Static Pressure | 70–100 Pa |
| Air Flow | 300–1500 CFM |
| Cooling Capacity | 2.35–13.0 kW |
| Heating Capacity | 3.90–22.17 kW |
| Power Supply | 220–240V / 1Ph / 50Hz |
| Coil Type | Copper Tube and Aluminum Fin |
| Number of Fan Speeds | 3 |
| Sound Level | 35–61 dB(A) |
Medium static pressure units are specified for hotel corridor systems, office floors with a central plant room, lecture theatres with a rear plant zone, and retail units where the diffusers sit well away from the ceiling void over the unit. They also suit schools and clinics where a filtered return is required and the filter box adds resistance that a low pressure unit could not overcome. In renovation work they can often reuse an existing duct layout that was designed for a higher pressure machine.
Fan decks are locked for transport and the coil face is protected by a rigid shield. Duct spigots are capped and the drain outlet is plugged. Optional attenuators, plenums and filters are supplied as matched accessories. Each unit is supplied with a static pressure table and a commissioning record form, so the balancing engineer can document the measured airflow and the fan speed setting used at handover.
The practical argument for specifying the correct static pressure is energy and acoustics. A unit running at the right point on its curve uses less fan power and produces less noise than one pushed beyond its design range to reach a distant diffuser.