Large floor plates and long duct runs demand a different class of fan coil. This high static pressure ducted unit delivers up to 200 Pascals of external static pressure with an airflow range of 800 to 2400 CFM — the territory of ballrooms, lecture theatres, large retail halls and open plan floors where air must travel through substantial ductwork before reaching the occupied zone.
At this pressure the mechanical design of the unit matters as much as the fan curve. The casing is a rigid frame with removable panels, the fan is a double inlet centrifugal assembly balanced at the factory, and the motor is mounted on a resilient base so that vibration does not travel into the building structure. The coil is sized for the full airflow so that the leaving air temperature remains stable even when the system is balanced down to a lower operating point.
| Air Flow | 800–2400 CFM |
|---|---|
| Static Pressure | Max. 200 Pa |
| Cooling Capacity | 2.35–13.0 kW |
| Heating Capacity | 3.90–22.17 kW |
| Power Supply | 220–240V / 1Ph / 50Hz |
| Coil Type | Copper Tube and Aluminum Fin |
| Max. Working Pressure | 1.6 MPa |
| Water Connection | G3/4 inch |
High static ducted units are used in function halls, auditoria, cinema foyers, large retail floors, factory offices and airport support buildings where the air handling position is remote from the occupied area. They also suit projects that need a high grade filtration section in the duct run, because the additional resistance is within the capability of the fan. Where a building has an existing duct network from a previous installation, this class of unit can often be matched to it without redesign.
Units are shipped on a reinforced pallet with the fan deck locked and the coil connections capped. Because of the size, lifting points are marked on the frame and a lifting plan is supplied with the first unit of each size. Optional filter sections and attenuators are packed as separate modules with matching flange drilling so that the assembly can be bolted together on site without modification.
For a consulting engineer the key advantage is margin. A unit with published performance at 200 Pascals allows for real world duct leakage and filter loading without the airflow collapsing in the second year of operation.
| MOQ: | Negotiable |
| Price: | Negotiable |
| Standard Packaging: | Standard |
| Delivery Period: | Negotiable |
| Payment Method: | TT |
| Supply Capacity: | Negotiable |
Large floor plates and long duct runs demand a different class of fan coil. This high static pressure ducted unit delivers up to 200 Pascals of external static pressure with an airflow range of 800 to 2400 CFM — the territory of ballrooms, lecture theatres, large retail halls and open plan floors where air must travel through substantial ductwork before reaching the occupied zone.
At this pressure the mechanical design of the unit matters as much as the fan curve. The casing is a rigid frame with removable panels, the fan is a double inlet centrifugal assembly balanced at the factory, and the motor is mounted on a resilient base so that vibration does not travel into the building structure. The coil is sized for the full airflow so that the leaving air temperature remains stable even when the system is balanced down to a lower operating point.
| Air Flow | 800–2400 CFM |
|---|---|
| Static Pressure | Max. 200 Pa |
| Cooling Capacity | 2.35–13.0 kW |
| Heating Capacity | 3.90–22.17 kW |
| Power Supply | 220–240V / 1Ph / 50Hz |
| Coil Type | Copper Tube and Aluminum Fin |
| Max. Working Pressure | 1.6 MPa |
| Water Connection | G3/4 inch |
High static ducted units are used in function halls, auditoria, cinema foyers, large retail floors, factory offices and airport support buildings where the air handling position is remote from the occupied area. They also suit projects that need a high grade filtration section in the duct run, because the additional resistance is within the capability of the fan. Where a building has an existing duct network from a previous installation, this class of unit can often be matched to it without redesign.
Units are shipped on a reinforced pallet with the fan deck locked and the coil connections capped. Because of the size, lifting points are marked on the frame and a lifting plan is supplied with the first unit of each size. Optional filter sections and attenuators are packed as separate modules with matching flange drilling so that the assembly can be bolted together on site without modification.
For a consulting engineer the key advantage is margin. A unit with published performance at 200 Pascals allows for real world duct leakage and filter loading without the airflow collapsing in the second year of operation.