A four pipe fan coil unit connects to two separate water circuits — one chilled and one hot — so the coil can cool or heat without waiting for a central plant to change over. In practice, a room on the shaded side of a building can be heated in the morning while a room on the sunny side is being cooled in the afternoon, using the same unit and the same control interface. This cassette version brings that capability into a ceiling grid installation with an integrated drain pump lifting condensate up to 750 millimetres.
The four pipe arrangement is common in hotels, hospitals and premium office buildings where the client wants individual room control independent of a seasonal changeover. The cassette format keeps the ceiling clean, and the pump removes the constraint of a continuous fall on the drain line — often the detail that decides whether a ceiling void can accommodate a cassette at all.
| Fluid | Chilled Water / Hot Water |
|---|---|
| Cooling Capacity | 1.58–8.25 kW |
| Heating Capacity | 1.77–8.50 kW |
| Drain Pump Head | 500–750 mm |
| Air Flow | 250–600 CFM |
| Power Supply | 220–240V / 1Ph / 50Hz |
| Coil Type | Copper Tube and Aluminum Fin |
| Water Connection | G1/2 – G3/4 inch |
Four pipe cassettes are specified for hotel guest rooms, hospital wards and consulting suites, premium office tenancies, and residential apartments in buildings with a central plant that supplies both chilled and hot water year round. They are particularly useful on multi-aspect floor plates, where solar gain differs between the east and west facades and a two pipe system would force the whole floor into one mode. In mixed-use buildings they let retail and office zones run on different schedules without a plant changeover.
The cassette and panel are packed separately to protect the finished surface, and the drain pump is secured with a transport clip that must be removed before commissioning. Water connections are capped and labelled so that chilled and hot circuits cannot be confused on site. A commissioning sheet covers pump lift verification, valve labelling and mode changeover testing, which shortens the witness testing required by hotel and hospital clients.
The operational benefit is flexibility. A four pipe system lets a building respond to individual room conditions instead of a building-wide season — exactly what hotel and healthcare operators need from their HVAC plant.
| MOQ: | Negotiable |
| Price: | Negotiable |
| Standard Packaging: | Standard |
| Delivery Period: | Negotiable |
| Payment Method: | TT |
| Supply Capacity: | Negotiable |
A four pipe fan coil unit connects to two separate water circuits — one chilled and one hot — so the coil can cool or heat without waiting for a central plant to change over. In practice, a room on the shaded side of a building can be heated in the morning while a room on the sunny side is being cooled in the afternoon, using the same unit and the same control interface. This cassette version brings that capability into a ceiling grid installation with an integrated drain pump lifting condensate up to 750 millimetres.
The four pipe arrangement is common in hotels, hospitals and premium office buildings where the client wants individual room control independent of a seasonal changeover. The cassette format keeps the ceiling clean, and the pump removes the constraint of a continuous fall on the drain line — often the detail that decides whether a ceiling void can accommodate a cassette at all.
| Fluid | Chilled Water / Hot Water |
|---|---|
| Cooling Capacity | 1.58–8.25 kW |
| Heating Capacity | 1.77–8.50 kW |
| Drain Pump Head | 500–750 mm |
| Air Flow | 250–600 CFM |
| Power Supply | 220–240V / 1Ph / 50Hz |
| Coil Type | Copper Tube and Aluminum Fin |
| Water Connection | G1/2 – G3/4 inch |
Four pipe cassettes are specified for hotel guest rooms, hospital wards and consulting suites, premium office tenancies, and residential apartments in buildings with a central plant that supplies both chilled and hot water year round. They are particularly useful on multi-aspect floor plates, where solar gain differs between the east and west facades and a two pipe system would force the whole floor into one mode. In mixed-use buildings they let retail and office zones run on different schedules without a plant changeover.
The cassette and panel are packed separately to protect the finished surface, and the drain pump is secured with a transport clip that must be removed before commissioning. Water connections are capped and labelled so that chilled and hot circuits cannot be confused on site. A commissioning sheet covers pump lift verification, valve labelling and mode changeover testing, which shortens the witness testing required by hotel and hospital clients.
The operational benefit is flexibility. A four pipe system lets a building respond to individual room conditions instead of a building-wide season — exactly what hotel and healthcare operators need from their HVAC plant.