A heat pump modular chiller removes an entire plant from a building. The same modules that produce chilled water in summer reverse to produce hot water in winter, so there is no separate boiler, no gas supply, no flue and no burner maintenance contract. This version uses 35 to 130 kilowatt modules with a heating operating range down to minus 15 degrees Celsius ambient, which covers the winter conditions of a large part of Europe, northern China and the high altitude regions of the Middle East.
The refrigerant circuit is arranged so that the reversing valve and the defrost logic work with the scroll compressors rather than against them. Defrost is initiated from measured coil conditions, which keeps the cycle short and avoids the long interruptions in heating output that occur when defrost is driven by a fixed timer. Because each module defrosts independently, the plant as a whole never stops heating while one module is in defrost.
| Cooling Capacity per Module | 35-130 kW |
|---|---|
| Heating Capacity per Module | 35-130 kW |
| Heating Operating Range | -15 °C to 48 °C |
| Compressor | Scroll Compressor |
| Refrigerant | R410A |
| Power Supply | 380-415V / 3Ph / 50Hz |
| Type | Air Cooled |
| Sound Level | 70 dB(A) |
Heat pump modular chillers are used in hotels, office buildings, schools, clinics and residential developments where a gas connection is unavailable or where the client wants to electrify the heating load. They also suit retrofit projects in buildings that currently run a boiler and a chiller separately, because the water distribution network can often be reused with only the plant room modified. In regions with a long heating season and mild summers, the same modules carry most of the annual load in heating mode.
Modules are shipped with the reversing valve and control parameters set for the destination market, and the refrigerant circuit is charged and pressure tested before dispatch. Coil faces are protected and fan decks braced for transport. A commissioning checklist covers defrost parameter verification, water flow balancing in both modes and the changeover sequence, which keeps the handover test short and repeatable.
For an owner, the value is one plant, one service contract and one set of spare parts across both seasons. For a consultant, the value is a heating source that does not need a gas riser or a flue through the roof slab.
| MOQ: | Negotiable |
| Price: | Negotiable |
| Standard Packaging: | Export standard |
| Delivery Period: | Negotiable |
| Payment Method: | TT |
| Supply Capacity: | Negotiable |
A heat pump modular chiller removes an entire plant from a building. The same modules that produce chilled water in summer reverse to produce hot water in winter, so there is no separate boiler, no gas supply, no flue and no burner maintenance contract. This version uses 35 to 130 kilowatt modules with a heating operating range down to minus 15 degrees Celsius ambient, which covers the winter conditions of a large part of Europe, northern China and the high altitude regions of the Middle East.
The refrigerant circuit is arranged so that the reversing valve and the defrost logic work with the scroll compressors rather than against them. Defrost is initiated from measured coil conditions, which keeps the cycle short and avoids the long interruptions in heating output that occur when defrost is driven by a fixed timer. Because each module defrosts independently, the plant as a whole never stops heating while one module is in defrost.
| Cooling Capacity per Module | 35-130 kW |
|---|---|
| Heating Capacity per Module | 35-130 kW |
| Heating Operating Range | -15 °C to 48 °C |
| Compressor | Scroll Compressor |
| Refrigerant | R410A |
| Power Supply | 380-415V / 3Ph / 50Hz |
| Type | Air Cooled |
| Sound Level | 70 dB(A) |
Heat pump modular chillers are used in hotels, office buildings, schools, clinics and residential developments where a gas connection is unavailable or where the client wants to electrify the heating load. They also suit retrofit projects in buildings that currently run a boiler and a chiller separately, because the water distribution network can often be reused with only the plant room modified. In regions with a long heating season and mild summers, the same modules carry most of the annual load in heating mode.
Modules are shipped with the reversing valve and control parameters set for the destination market, and the refrigerant circuit is charged and pressure tested before dispatch. Coil faces are protected and fan decks braced for transport. A commissioning checklist covers defrost parameter verification, water flow balancing in both modes and the changeover sequence, which keeps the handover test short and repeatable.
For an owner, the value is one plant, one service contract and one set of spare parts across both seasons. For a consultant, the value is a heating source that does not need a gas riser or a flue through the roof slab.