Cascaded Air Cooled Chiller 2240 kW 256 Modules N+1 Redundancy Modular Plant Design

Cascaded Air Cooled Chiller 2240 kW 256 Modules N+1 Redundancy Modular Plant Design

MOQ: Negotiable
Price: Negotiable
Standard Packaging: Export standard
Delivery Period: Negotiable
Payment Method: TT
Supply Capacity: Negotiable
Detail Information
Place of Origin
China
Brand Name
midea、Hongtai HVAC
Certification
CE, AHRI 550/590
Maximum Cascaded Capacity:
2,240 KW
Maximum Module Count:
256 Units
Redundancy:
N+1 / N+2 Configurable
Compressor:
Scroll Compressor
Refrigerant:
R410A
Power Supply:
380-415V / 3Ph / 50Hz
Capacity Control:
IDV Variable Capacity
Type:
Air Cooled
Highlight:

Cascaded Air Cooled Chiller 2240 kW

,

Modular Air Cooled Chiller N+1 Redundancy

,

256 Module Modular Chiller Plant Design

Product Description
Cascaded Modular Air-Cooled Chiller Plant Overview

Very large cooling loads once demanded very large machines, along with the lifting, rigging and single-point-of-failure consequences that follow. A cascaded modular plant takes the opposite approach: individual modules are networked together so total installed capacity can reach 2,240 kilowatts across as many as 256 units, while each module remains a standard, replaceable package that can be delivered through a normal service lift.

The cascade controller treats the group as one plant. It stages modules in and out according to the aggregate load, rotates the lead module to equalise running hours, and holds the configured redundancy so that a module under maintenance does not reduce available capacity below the design requirement. Because control is distributed across the network rather than concentrated in one large machine, a single module failure becomes a maintenance item rather than a building event.

Key Features of the Cascaded Chiller Plant
  • Up to 2,240 kW Cascaded Capacity: Total plant capacity scales to very large loads while every module remains a standard package that is easy to transport and replace.
  • 256-Module Network: The cascade controller handles large module counts without a central proprietary controller that would become a single point of failure.
  • N+1 and N+2 Redundancy: Redundancy can be configured at the design stage to match building criticality, which is difficult with a small number of large machines.
  • Automatic Lead Rotation: The controller rotates the lead module so running hours are equalised and no single module wears out ahead of the rest.
  • Stagewise Loading: Modules start in sequence as the load rises, so the running plant always sits close to its efficient operating band.
  • Standard Module Package: Because each module is a standard product, spare parts holding and swap-out maintenance are straightforward.
Technical Specifications
Parameter Specification
Maximum Cascaded Capacity 2,240 kW
Maximum Module Count 256 units
Redundancy N+1 / N+2 configurable
Compressor Scroll Compressor
Refrigerant R410A
Power Supply 380-415V / 3Ph / 50Hz
Capacity Control IDV Variable Capacity
Type Air Cooled
Applications for Cascaded Modular Cooling Plants

Cascaded modular plants are used in district cooling substations, large shopping centres, airport support buildings, data centre cooling and industrial facilities where the load is high and the availability requirement is strict. They also suit campuses where cooling demand grows building by building, because modules can be added to the network without replacing the plant or rewriting the control strategy. Where roof space is limited, modules can be arranged in rows with the cascade controller managing staging across the whole group.

Packaging & Quality Assurance

Modules ship as standard packages on export pallets with coils protected and fan decks braced. The cascade controller, network cable and address plan are supplied as a coordinated kit, with a wiring diagram that maps each module to its address and its position in the staging sequence. Commissioning support covers network addressing, redundancy configuration and the load sharing test — the part of a large plant that most often delays handover.

The business case for a cascaded plant is resilience. A building with two large chillers loses half its capacity when one machine stops; a building with twenty modules loses five percent, and the controller can often absorb even that within the redundancy allowance.

Products
PRODUCTS DETAILS
Cascaded Air Cooled Chiller 2240 kW 256 Modules N+1 Redundancy Modular Plant Design
MOQ: Negotiable
Price: Negotiable
Standard Packaging: Export standard
Delivery Period: Negotiable
Payment Method: TT
Supply Capacity: Negotiable
Detail Information
Place of Origin
China
Brand Name
midea、Hongtai HVAC
Certification
CE, AHRI 550/590
Maximum Cascaded Capacity:
2,240 KW
Maximum Module Count:
256 Units
Redundancy:
N+1 / N+2 Configurable
Compressor:
Scroll Compressor
Refrigerant:
R410A
Power Supply:
380-415V / 3Ph / 50Hz
Capacity Control:
IDV Variable Capacity
Type:
Air Cooled
Minimum Order Quantity:
Negotiable
Price:
Negotiable
Packaging Details:
Export standard
Delivery Time:
Negotiable
Payment Terms:
TT
Supply Ability:
Negotiable
Highlight

Cascaded Air Cooled Chiller 2240 kW

,

Modular Air Cooled Chiller N+1 Redundancy

,

256 Module Modular Chiller Plant Design

Product Description
Cascaded Modular Air-Cooled Chiller Plant Overview

Very large cooling loads once demanded very large machines, along with the lifting, rigging and single-point-of-failure consequences that follow. A cascaded modular plant takes the opposite approach: individual modules are networked together so total installed capacity can reach 2,240 kilowatts across as many as 256 units, while each module remains a standard, replaceable package that can be delivered through a normal service lift.

The cascade controller treats the group as one plant. It stages modules in and out according to the aggregate load, rotates the lead module to equalise running hours, and holds the configured redundancy so that a module under maintenance does not reduce available capacity below the design requirement. Because control is distributed across the network rather than concentrated in one large machine, a single module failure becomes a maintenance item rather than a building event.

Key Features of the Cascaded Chiller Plant
  • Up to 2,240 kW Cascaded Capacity: Total plant capacity scales to very large loads while every module remains a standard package that is easy to transport and replace.
  • 256-Module Network: The cascade controller handles large module counts without a central proprietary controller that would become a single point of failure.
  • N+1 and N+2 Redundancy: Redundancy can be configured at the design stage to match building criticality, which is difficult with a small number of large machines.
  • Automatic Lead Rotation: The controller rotates the lead module so running hours are equalised and no single module wears out ahead of the rest.
  • Stagewise Loading: Modules start in sequence as the load rises, so the running plant always sits close to its efficient operating band.
  • Standard Module Package: Because each module is a standard product, spare parts holding and swap-out maintenance are straightforward.
Technical Specifications
Parameter Specification
Maximum Cascaded Capacity 2,240 kW
Maximum Module Count 256 units
Redundancy N+1 / N+2 configurable
Compressor Scroll Compressor
Refrigerant R410A
Power Supply 380-415V / 3Ph / 50Hz
Capacity Control IDV Variable Capacity
Type Air Cooled
Applications for Cascaded Modular Cooling Plants

Cascaded modular plants are used in district cooling substations, large shopping centres, airport support buildings, data centre cooling and industrial facilities where the load is high and the availability requirement is strict. They also suit campuses where cooling demand grows building by building, because modules can be added to the network without replacing the plant or rewriting the control strategy. Where roof space is limited, modules can be arranged in rows with the cascade controller managing staging across the whole group.

Packaging & Quality Assurance

Modules ship as standard packages on export pallets with coils protected and fan decks braced. The cascade controller, network cable and address plan are supplied as a coordinated kit, with a wiring diagram that maps each module to its address and its position in the staging sequence. Commissioning support covers network addressing, redundancy configuration and the load sharing test — the part of a large plant that most often delays handover.

The business case for a cascaded plant is resilience. A building with two large chillers loses half its capacity when one machine stops; a building with twenty modules loses five percent, and the controller can often absorb even that within the redundancy allowance.