Export projects frequently require the same chiller in two electrical variants, since contractors work across markets with different supply frequencies. This modular chiller is available in both 50Hz and 60Hz configurations across a 60 to 250 kilowatt capacity range, with the compressor drive, fan motors and control parameters matched to the destination network rather than adapted on site.
The plant is built from scroll compressor modules using R410A refrigerant and is intended for commercial cooling duty in buildings where the load varies through the day. Modules are added to match the design load, so a 250 kilowatt requirement can be met by a combination of smaller modules running in sequence rather than one large machine operating at a poor part load ratio for most of the year.
| Cooling Capacity Range | 75-180 kW |
|---|---|
| Compressor | Scroll Compressor |
| Refrigerant | R410A |
| Frequency | 60 Hz |
| Optional Power Supply | 380V-460V 50/60Hz |
| Type | Air Cooled |
| Sound Level | 70 dB(A) |
| COP | 3.2+ |
This configuration is used by contractors and trading companies supplying projects in Africa, the Middle East, Southeast Asia and Latin America, where the same building design is repeated across countries with different supply frequencies. Typical applications include hotels, office buildings, clinics, food processing facilities and shopping centres. Because the modules are standard packages, a distributor can hold a small stock of one size and cover a range of project loads by combining them.
Modules are packed for sea freight on export pallets with coil protection, braced fan decks and sealed electrical enclosures. The nameplate and the wiring diagram are matched to the ordered frequency variant, and a label on the crate identifies the configuration so that mixed shipments cannot be installed incorrectly. Performance tables at the project ambient condition and a commissioning record form are included.
For an exporter, a factory configured frequency variant removes the most common source of warranty dispute on HVAC equipment shipped to a different market. For the end user, it means the capacity on the nameplate is the capacity delivered on site.
| MOQ: | Negotiable |
| Price: | Negotiable |
| Standard Packaging: | Export standard |
| Delivery Period: | Negotiable |
| Payment Method: | TT |
| Supply Capacity: | Negotiable |
Export projects frequently require the same chiller in two electrical variants, since contractors work across markets with different supply frequencies. This modular chiller is available in both 50Hz and 60Hz configurations across a 60 to 250 kilowatt capacity range, with the compressor drive, fan motors and control parameters matched to the destination network rather than adapted on site.
The plant is built from scroll compressor modules using R410A refrigerant and is intended for commercial cooling duty in buildings where the load varies through the day. Modules are added to match the design load, so a 250 kilowatt requirement can be met by a combination of smaller modules running in sequence rather than one large machine operating at a poor part load ratio for most of the year.
| Cooling Capacity Range | 75-180 kW |
|---|---|
| Compressor | Scroll Compressor |
| Refrigerant | R410A |
| Frequency | 60 Hz |
| Optional Power Supply | 380V-460V 50/60Hz |
| Type | Air Cooled |
| Sound Level | 70 dB(A) |
| COP | 3.2+ |
This configuration is used by contractors and trading companies supplying projects in Africa, the Middle East, Southeast Asia and Latin America, where the same building design is repeated across countries with different supply frequencies. Typical applications include hotels, office buildings, clinics, food processing facilities and shopping centres. Because the modules are standard packages, a distributor can hold a small stock of one size and cover a range of project loads by combining them.
Modules are packed for sea freight on export pallets with coil protection, braced fan decks and sealed electrical enclosures. The nameplate and the wiring diagram are matched to the ordered frequency variant, and a label on the crate identifies the configuration so that mixed shipments cannot be installed incorrectly. Performance tables at the project ambient condition and a commissioning record form are included.