At minus twenty degrees Celsius, a conventional heat pump loses both capacity and efficiency, and many machines stop delivering useful heat altogether. Enhanced Vapour Injection (EVI) changes that. By injecting intermediate-pressure vapour into the compression process, the EVI circuit lowers discharge temperature and increases mass flow through the evaporator, allowing the machine to keep producing hot water at an ambient temperature where a standard circuit would be operating outside its safe envelope.
This modular EVI heat pump chiller is rated with a COP of 3.27 in low ambient heating duty and is built for commercial buildings in cold climates where the heating season dominates the annual energy profile. Modules are networked in the same way as a cooling plant, so capacity can be staged to the load and a single module can be taken out of service for maintenance without interrupting the heating supply.
| Parameter | Specification |
|---|---|
| Heating Capacity | Available (heat pump models) |
| Heating Operating Range | -15 °C to 48 °C |
| COP | 3.2+ |
| Compressor | Scroll Compressor |
| Refrigerant | R410A |
| Power Supply | 380-415V / 3Ph / 50Hz |
| Type | Air Cooled |
| Sound Level | 70 dB(A) |
EVI heat pump chillers are specified for commercial buildings in northern China, Central Asia, Eastern Europe, Mongolia and northern Japan, where the winter design condition falls well below freezing. Typical applications include office buildings, hotels, schools, district heating substations and industrial processes that need hot water through the winter. They also suit rural and off-gas-grid developments where a boiler would require fuel deliveries that are expensive or unreliable.
Modules are shipped with the EVI circuit charged and pressure tested, the control parameters set for low ambient operation, and the drain paths protected against freezing during transport. A cold climate commissioning checklist covers defrost verification, low ambient start testing and the hot water set point schedule — the documentation most often requested by a cold climate client at handover.
For a cold climate owner, the decision usually comes down to two numbers: the ambient temperature at which the machine still produces heat, and the COP at that condition. Both are documented for this platform, which makes the comparison against a boiler plus chiller arrangement straightforward.
| MOQ: | Negotiable |
| Price: | Negotiable |
| Standard Packaging: | Export standard |
| Delivery Period: | Negotiable |
| Payment Method: | TT |
| Supply Capacity: | Negotiable |
At minus twenty degrees Celsius, a conventional heat pump loses both capacity and efficiency, and many machines stop delivering useful heat altogether. Enhanced Vapour Injection (EVI) changes that. By injecting intermediate-pressure vapour into the compression process, the EVI circuit lowers discharge temperature and increases mass flow through the evaporator, allowing the machine to keep producing hot water at an ambient temperature where a standard circuit would be operating outside its safe envelope.
This modular EVI heat pump chiller is rated with a COP of 3.27 in low ambient heating duty and is built for commercial buildings in cold climates where the heating season dominates the annual energy profile. Modules are networked in the same way as a cooling plant, so capacity can be staged to the load and a single module can be taken out of service for maintenance without interrupting the heating supply.
| Parameter | Specification |
|---|---|
| Heating Capacity | Available (heat pump models) |
| Heating Operating Range | -15 °C to 48 °C |
| COP | 3.2+ |
| Compressor | Scroll Compressor |
| Refrigerant | R410A |
| Power Supply | 380-415V / 3Ph / 50Hz |
| Type | Air Cooled |
| Sound Level | 70 dB(A) |
EVI heat pump chillers are specified for commercial buildings in northern China, Central Asia, Eastern Europe, Mongolia and northern Japan, where the winter design condition falls well below freezing. Typical applications include office buildings, hotels, schools, district heating substations and industrial processes that need hot water through the winter. They also suit rural and off-gas-grid developments where a boiler would require fuel deliveries that are expensive or unreliable.
Modules are shipped with the EVI circuit charged and pressure tested, the control parameters set for low ambient operation, and the drain paths protected against freezing during transport. A cold climate commissioning checklist covers defrost verification, low ambient start testing and the hot water set point schedule — the documentation most often requested by a cold climate client at handover.
For a cold climate owner, the decision usually comes down to two numbers: the ambient temperature at which the machine still produces heat, and the COP at that condition. Both are documented for this platform, which makes the comparison against a boiler plus chiller arrangement straightforward.