Chiller noise complaints rarely come from full load operation, because full load usually coincides with the noisiest part of the day. They come from part load running at night, when the building is quiet, the ambient noise floor drops, and a fan deck two floors below a bedroom window becomes audible. This modular chiller is specified with a 65 dB(A) part load sound level — the condition that actually determines whether a rooftop plant is acceptable in a residential or hotel context.
Acoustic performance is achieved through the fan and coil arrangement rather than through add-on enclosures. Low speed fan operation at part load, a fan deck layout that avoids tonal noise, and a compressor mounting arrangement that limits structure-borne vibration together bring the measured level down without blocking the airflow the condenser needs. For sites with a strict boundary limit, an optional noise reduction package can lower the level by a further 5 to 10 dB(A).
| Parameter | Specification |
|---|---|
| Part-Load Noise | 65 dB(A) |
| Sound Level | 70 dB(A) |
| Noise Reduction Option | 5–10 dB(A) |
| Compressor | Scroll Compressor |
| Refrigerant | R410A |
| Power Supply | 380–415V / 3Ph / 50Hz |
| Type | Air Cooled |
| Cooling Operating Range | 0 °C to 48 °C |
Low noise modular chillers are specified for hotels with rooftop plant above guest floors, residential towers with a podium plant deck, hospitals with wards near the plant area, and office buildings in dense urban blocks where the boundary is close to neighbouring windows. They also suit mixed-use developments where the acoustic assessment is part of the planning consent, because the part load figure can be entered directly into the noise model rather than estimated.
Modules ship with the fan decks braced, coils protected, and the acoustic treatment secured for transport. Where the optional noise package is ordered, the additional panels are packed separately with a fitting drawing. A sound pressure data sheet at the reference distance — measured at both part load and full load — is supplied with each consignment so that the acoustic consultant can verify the installation against the planning condition.
| MOQ: | Negotiable |
| Price: | Negotiable |
| Standard Packaging: | Export standard |
| Delivery Period: | Negotiable |
| Payment Method: | TT |
| Supply Capacity: | Negotiable |
Chiller noise complaints rarely come from full load operation, because full load usually coincides with the noisiest part of the day. They come from part load running at night, when the building is quiet, the ambient noise floor drops, and a fan deck two floors below a bedroom window becomes audible. This modular chiller is specified with a 65 dB(A) part load sound level — the condition that actually determines whether a rooftop plant is acceptable in a residential or hotel context.
Acoustic performance is achieved through the fan and coil arrangement rather than through add-on enclosures. Low speed fan operation at part load, a fan deck layout that avoids tonal noise, and a compressor mounting arrangement that limits structure-borne vibration together bring the measured level down without blocking the airflow the condenser needs. For sites with a strict boundary limit, an optional noise reduction package can lower the level by a further 5 to 10 dB(A).
| Parameter | Specification |
|---|---|
| Part-Load Noise | 65 dB(A) |
| Sound Level | 70 dB(A) |
| Noise Reduction Option | 5–10 dB(A) |
| Compressor | Scroll Compressor |
| Refrigerant | R410A |
| Power Supply | 380–415V / 3Ph / 50Hz |
| Type | Air Cooled |
| Cooling Operating Range | 0 °C to 48 °C |
Low noise modular chillers are specified for hotels with rooftop plant above guest floors, residential towers with a podium plant deck, hospitals with wards near the plant area, and office buildings in dense urban blocks where the boundary is close to neighbouring windows. They also suit mixed-use developments where the acoustic assessment is part of the planning consent, because the part load figure can be entered directly into the noise model rather than estimated.
Modules ship with the fan decks braced, coils protected, and the acoustic treatment secured for transport. Where the optional noise package is ordered, the additional panels are packed separately with a fitting drawing. A sound pressure data sheet at the reference distance — measured at both part load and full load — is supplied with each consignment so that the acoustic consultant can verify the installation against the planning condition.