Midea VC Max DOAS 100 Outdoor Air for Hot Humid Climates Fresh Air That Arrives Dry Cool and Filtered

Midea VC Max DOAS 100 Outdoor Air for Hot Humid Climates Fresh Air That Arrives Dry Cool and Filtered

Detail Information
Place of Origin
China
Brand Name
OEM;MIDEA
Certification
CB,ISO
Product Name:
VC Max (DOAS)
Capacity Range:
8 - 24 HP
Fresh Air Volume:
1,500 - 10,000 M3/h
IEEREnergy Recovery:
High-efficiency Plate Heat Exchanger
Communication Protocol:
BACnet / Modbus RTU
Power Supply:
380-415V / 3Ph / 50Hz
Climate Rating:
T3 (55 Degrees Celsius)
Certifications CE, Eurovent, TUV SUD, ISO 9001/14001/45001:
CE, Eurovent, TUV SUD, ISO 9001/14001/45001
Highlight:

Midea VC Max DOAS outdoor air unit

,

DOAS for hot humid climates

,

DC Inverter VRF fresh air

Product Description
Product Overview: 100% Outdoor Air Dedicated System

The Midea VC Max is a dedicated outdoor air system (DOAS) covering 8 to 24 HP with a fresh air volume of 1,500 to 10,000 m³/h. It handles the part of HVAC design that VRF systems cannot: taking 100 percent outdoor air, removing its latent load, filtering it, and delivering it to occupied spaces at a condition that supports rather than fights the room system.

In hot and humid markets this is the component that determines whether a building feels comfortable. A coastal resort at 85 percent relative humidity, a Gulf city where summer dew points exceed 25°C, or a tropical office where the fresh air requirement is driven by occupancy all present the same problem: the outdoor air carries more moisture than the space can absorb. If that moisture is left to the room units, they run continuously at part load chasing a latent load they were not designed for, and the space feels cold and clammy at the same time.

The VC Max resolves that by separating the latent load from the sensible load. A high-efficiency plate heat exchanger recovers energy from the exhaust stream, deep dehumidification brings supply air below 40 percent relative humidity, and multi-stage filtration with a G4 pre-filter plus F7 or F9 final filter delivers air quality appropriate to the application. The room VRF system then handles only sensible cooling, at a higher evaporating temperature and a lower energy cost.

Key Features Deep Dive
1. One-Hundred-Percent Outdoor Air Processing

A dedicated outdoor air system does one job and does it completely: it takes outdoor air, conditions it, and delivers it. Unlike a mixed-air air handling unit that blends return air with fresh air and inherits the condition of both, the VC Max processes 100 percent outdoor air, so the supply condition is determined by design rather than by what happens to be returning from the space.

This separation gives the design engineer independent control over ventilation and temperature. Fresh air volumes can be set to meet occupancy requirements without affecting room temperature control, and room units can be sized for sensible load alone. In buildings with variable occupancy, from conference hotels to restaurants, that independence is what allows ventilation to track people while cooling tracks heat.

  • Processes 100 percent outdoor air with no return air mixing
  • Ventilation volume set independently of room cooling load
  • Supply air condition determined by design, not by return air state
  • Room units sized for sensible load only
  • Ventilation tracks occupancy independently of temperature control
  • Suited to buildings with highly variable occupancy patterns
2. Deep Dehumidification Below 40 Percent Supply RH

Latent load is the dominant comfort problem in humid climates, and it cannot be solved by making the air colder. A room unit that overcools to remove moisture produces a space that is simultaneously cold and humid, which occupants experience as uncomfortable regardless of the thermostat reading. The VC Max removes moisture directly, delivering supply air below 40 percent relative humidity.

The consequence for the room system is significant. When the outdoor air arrives dry, the room units no longer carry a latent load, so they can operate at a higher evaporating temperature and a lower compression ratio. That reduces energy consumption across the whole system, and it eliminates the condensation and microbial growth risk that comes from coils running continuously below dew point.

  • Supply air delivered below 40 percent relative humidity
  • Latent load removed at the source rather than by overcooling
  • Room units operate at higher evaporating temperature
  • Lower compression ratio and reduced system energy consumption
  • No continuous coil operation below dew point in occupied spaces
  • Consistent comfort in tropical and coastal conditions
3. High-Efficiency Plate Heat Exchanger Energy Recovery

Ventilation is expensive when the outdoor air is at 45°C and 80 percent relative humidity. Every cubic metre brought in has to be cooled and dried, and every cubic metre exhausted carries conditioned energy out of the building. The VC Max recovers that energy through a high-efficiency plate heat exchanger, transferring heat and moisture between the exhaust and supply streams.

In hot and humid climates, total energy recovery rather than sensible-only recovery is what makes the economics work. Moisture transfer reduces the latent load that the cooling coil must handle, which reduces both coil depth and refrigeration capacity. The result is a smaller, cheaper unit delivering the same supply air condition, with lower operating cost across the life of the system.

  • High-efficiency plate heat exchanger for heat and moisture transfer
  • Total energy recovery suited to humid climate operation
  • Reduced latent load on the cooling coil
  • Smaller refrigeration capacity for the same supply condition
  • Lower ventilation energy cost across the system life
  • Supports green building certification energy targets
4. Multi-Stage Filtration with G4, F7, and F9 Options

Outdoor air in hot-climate cities carries dust, sand, and combustion particulate, and in coastal locations it carries salt aerosol. The VC Max uses multi-stage filtration with a G4 pre-filter protecting the coil and heat exchanger, followed by an F7 or F9 final filter appropriate to the application's air quality requirement.

Filter selection is a design decision rather than a fixed specification. A retail or office application may be adequately served by G4 plus F7, while a healthcare or food service application may require F9 final filtration. Because the filtration stage is separate from the room units, filter changes are concentrated in one accessible location rather than distributed across dozens of indoor units.

  • G4 pre-filter protecting coil and heat exchanger
  • F7 or F9 final filter selected to application requirement
  • Multi-stage arrangement extending filter life
  • Centralised filter maintenance in one accessible unit
  • Suitable for dusty, sandy, and coastal air conditions
  • Supports indoor air quality targets in commercial buildings
5. T3 Rating for High-Ambient Ventilation Duty

A dedicated outdoor air unit works with the harshest air the building sees, because it takes the full outdoor condition rather than a mixture. At 50°C ambient and high humidity, the refrigeration circuit is operating at the top of its envelope continuously. The VC Max is rated T3 for operation up to 55°C ambient.

This matters for reliability rather than for marketing. A unit that protects itself by reducing output in extreme heat delivers less fresh air exactly when occupancy and outdoor temperature peak together, which is when ventilation is most needed. Full-capacity operation at design ambient means the specified fresh air volume is the delivered fresh air volume.

  • T3 rated for operation up to 55°C ambient
  • Full capacity maintained at design outdoor conditions
  • Designed for continuous duty on 100 percent outdoor air
  • No ventilation shortfall during peak heat periods
  • Reliable operation in desert, tropical, and coastal climates
  • Consistent supply conditions regardless of outdoor extremes
6. BACnet and Modbus Integration for Centralised Control

The VC Max integrates with building management systems through BACnet and Modbus RTU, allowing fresh air volumes, supply conditions, and filter status to be monitored and adjusted centrally. In a building with multiple air handling units serving different zones, that centralised visibility is what makes ventilation management practical.

Coordination with the room VRF system happens at the BMS level: the outdoor air unit maintains the ventilation and latent load, the room units maintain temperature, and the building management system balances the two against occupancy schedules. Filter differential pressure monitoring provides advance warning of loading, so replacement is scheduled rather than reactive.

  • BACnet and Modbus RTU protocol support
  • Centralised monitoring of supply conditions and fresh air volume
  • Coordination with room VRF systems at BMS level
  • Filter status monitoring for planned replacement
  • Operating data available for energy reporting
  • Remote adjustment of ventilation schedules by zone
Technical Specifications
Model SeriesVC Max (DOAS)
BrandMidea / Hongtai
Capacity Range8 - 24 HP
Fresh Air Volume1,500 - 10,000 m³/h
FunctionDedicated Outdoor Air Processing (100% OA)
Energy RecoveryHigh-efficiency plate heat exchanger
Dehumidification CapacityDeep dehumidification to below 40% RH supply
FiltrationMulti-stage: G4 pre-filter + F7/F9 final filter
Climate RatingT3 (55 degrees Celsius)
Communication ProtocolBACnet / Modbus RTU
Power Supply380-415V / 3Ph / 50Hz
Warranty5 Years
OriginChina
CertificationsCE, Eurovent, TUV SUD, ISO 9001/14001/45001
Applications
  • Coastal and Island Resorts: Hospitality projects where high humidity and salt air make latent load control the primary comfort challenge
  • Gulf and North African Commercial Buildings: Offices and retail centres where summer dew points exceed the capacity of room units to handle moisture
  • Tropical Office and Mixed-Use Developments: Buildings with high occupancy density requiring ventilation independent of temperature control
  • Hot-Climate Healthcare Facilities: Clinical spaces requiring filtered, dehumidified outdoor air with controlled supply conditions
  • Food Service and Hospitality Kitchens: Premises with high moisture generation needing dedicated outdoor air treatment
  • Green Building Certification Projects: Developments pursuing energy targets that require heat recovery on ventilation air
Certifications & Standards
  • CE Certified for European Market Compliance
  • Eurovent Certified Performance for Air Handling Units
  • TUV SUD Tested and Certified
  • ISO 9001 Quality Management System
  • ISO 14001 Environmental Management System
  • ISO 45001 Occupational Health and Safety Management System
  • T3 Tropical Climate Rating for Extreme Temperature Operation
  • Compliant with International Ventilation and Indoor Air Quality Standards
Products
PRODUCTS DETAILS
Midea VC Max DOAS 100 Outdoor Air for Hot Humid Climates Fresh Air That Arrives Dry Cool and Filtered
Detail Information
Place of Origin
China
Brand Name
OEM;MIDEA
Certification
CB,ISO
Product Name:
VC Max (DOAS)
Capacity Range:
8 - 24 HP
Fresh Air Volume:
1,500 - 10,000 M3/h
IEEREnergy Recovery:
High-efficiency Plate Heat Exchanger
Communication Protocol:
BACnet / Modbus RTU
Power Supply:
380-415V / 3Ph / 50Hz
Climate Rating:
T3 (55 Degrees Celsius)
Certifications CE, Eurovent, TUV SUD, ISO 9001/14001/45001:
CE, Eurovent, TUV SUD, ISO 9001/14001/45001
Highlight

Midea VC Max DOAS outdoor air unit

,

DOAS for hot humid climates

,

DC Inverter VRF fresh air

Product Description
Product Overview: 100% Outdoor Air Dedicated System

The Midea VC Max is a dedicated outdoor air system (DOAS) covering 8 to 24 HP with a fresh air volume of 1,500 to 10,000 m³/h. It handles the part of HVAC design that VRF systems cannot: taking 100 percent outdoor air, removing its latent load, filtering it, and delivering it to occupied spaces at a condition that supports rather than fights the room system.

In hot and humid markets this is the component that determines whether a building feels comfortable. A coastal resort at 85 percent relative humidity, a Gulf city where summer dew points exceed 25°C, or a tropical office where the fresh air requirement is driven by occupancy all present the same problem: the outdoor air carries more moisture than the space can absorb. If that moisture is left to the room units, they run continuously at part load chasing a latent load they were not designed for, and the space feels cold and clammy at the same time.

The VC Max resolves that by separating the latent load from the sensible load. A high-efficiency plate heat exchanger recovers energy from the exhaust stream, deep dehumidification brings supply air below 40 percent relative humidity, and multi-stage filtration with a G4 pre-filter plus F7 or F9 final filter delivers air quality appropriate to the application. The room VRF system then handles only sensible cooling, at a higher evaporating temperature and a lower energy cost.

Key Features Deep Dive
1. One-Hundred-Percent Outdoor Air Processing

A dedicated outdoor air system does one job and does it completely: it takes outdoor air, conditions it, and delivers it. Unlike a mixed-air air handling unit that blends return air with fresh air and inherits the condition of both, the VC Max processes 100 percent outdoor air, so the supply condition is determined by design rather than by what happens to be returning from the space.

This separation gives the design engineer independent control over ventilation and temperature. Fresh air volumes can be set to meet occupancy requirements without affecting room temperature control, and room units can be sized for sensible load alone. In buildings with variable occupancy, from conference hotels to restaurants, that independence is what allows ventilation to track people while cooling tracks heat.

  • Processes 100 percent outdoor air with no return air mixing
  • Ventilation volume set independently of room cooling load
  • Supply air condition determined by design, not by return air state
  • Room units sized for sensible load only
  • Ventilation tracks occupancy independently of temperature control
  • Suited to buildings with highly variable occupancy patterns
2. Deep Dehumidification Below 40 Percent Supply RH

Latent load is the dominant comfort problem in humid climates, and it cannot be solved by making the air colder. A room unit that overcools to remove moisture produces a space that is simultaneously cold and humid, which occupants experience as uncomfortable regardless of the thermostat reading. The VC Max removes moisture directly, delivering supply air below 40 percent relative humidity.

The consequence for the room system is significant. When the outdoor air arrives dry, the room units no longer carry a latent load, so they can operate at a higher evaporating temperature and a lower compression ratio. That reduces energy consumption across the whole system, and it eliminates the condensation and microbial growth risk that comes from coils running continuously below dew point.

  • Supply air delivered below 40 percent relative humidity
  • Latent load removed at the source rather than by overcooling
  • Room units operate at higher evaporating temperature
  • Lower compression ratio and reduced system energy consumption
  • No continuous coil operation below dew point in occupied spaces
  • Consistent comfort in tropical and coastal conditions
3. High-Efficiency Plate Heat Exchanger Energy Recovery

Ventilation is expensive when the outdoor air is at 45°C and 80 percent relative humidity. Every cubic metre brought in has to be cooled and dried, and every cubic metre exhausted carries conditioned energy out of the building. The VC Max recovers that energy through a high-efficiency plate heat exchanger, transferring heat and moisture between the exhaust and supply streams.

In hot and humid climates, total energy recovery rather than sensible-only recovery is what makes the economics work. Moisture transfer reduces the latent load that the cooling coil must handle, which reduces both coil depth and refrigeration capacity. The result is a smaller, cheaper unit delivering the same supply air condition, with lower operating cost across the life of the system.

  • High-efficiency plate heat exchanger for heat and moisture transfer
  • Total energy recovery suited to humid climate operation
  • Reduced latent load on the cooling coil
  • Smaller refrigeration capacity for the same supply condition
  • Lower ventilation energy cost across the system life
  • Supports green building certification energy targets
4. Multi-Stage Filtration with G4, F7, and F9 Options

Outdoor air in hot-climate cities carries dust, sand, and combustion particulate, and in coastal locations it carries salt aerosol. The VC Max uses multi-stage filtration with a G4 pre-filter protecting the coil and heat exchanger, followed by an F7 or F9 final filter appropriate to the application's air quality requirement.

Filter selection is a design decision rather than a fixed specification. A retail or office application may be adequately served by G4 plus F7, while a healthcare or food service application may require F9 final filtration. Because the filtration stage is separate from the room units, filter changes are concentrated in one accessible location rather than distributed across dozens of indoor units.

  • G4 pre-filter protecting coil and heat exchanger
  • F7 or F9 final filter selected to application requirement
  • Multi-stage arrangement extending filter life
  • Centralised filter maintenance in one accessible unit
  • Suitable for dusty, sandy, and coastal air conditions
  • Supports indoor air quality targets in commercial buildings
5. T3 Rating for High-Ambient Ventilation Duty

A dedicated outdoor air unit works with the harshest air the building sees, because it takes the full outdoor condition rather than a mixture. At 50°C ambient and high humidity, the refrigeration circuit is operating at the top of its envelope continuously. The VC Max is rated T3 for operation up to 55°C ambient.

This matters for reliability rather than for marketing. A unit that protects itself by reducing output in extreme heat delivers less fresh air exactly when occupancy and outdoor temperature peak together, which is when ventilation is most needed. Full-capacity operation at design ambient means the specified fresh air volume is the delivered fresh air volume.

  • T3 rated for operation up to 55°C ambient
  • Full capacity maintained at design outdoor conditions
  • Designed for continuous duty on 100 percent outdoor air
  • No ventilation shortfall during peak heat periods
  • Reliable operation in desert, tropical, and coastal climates
  • Consistent supply conditions regardless of outdoor extremes
6. BACnet and Modbus Integration for Centralised Control

The VC Max integrates with building management systems through BACnet and Modbus RTU, allowing fresh air volumes, supply conditions, and filter status to be monitored and adjusted centrally. In a building with multiple air handling units serving different zones, that centralised visibility is what makes ventilation management practical.

Coordination with the room VRF system happens at the BMS level: the outdoor air unit maintains the ventilation and latent load, the room units maintain temperature, and the building management system balances the two against occupancy schedules. Filter differential pressure monitoring provides advance warning of loading, so replacement is scheduled rather than reactive.

  • BACnet and Modbus RTU protocol support
  • Centralised monitoring of supply conditions and fresh air volume
  • Coordination with room VRF systems at BMS level
  • Filter status monitoring for planned replacement
  • Operating data available for energy reporting
  • Remote adjustment of ventilation schedules by zone
Technical Specifications
Model SeriesVC Max (DOAS)
BrandMidea / Hongtai
Capacity Range8 - 24 HP
Fresh Air Volume1,500 - 10,000 m³/h
FunctionDedicated Outdoor Air Processing (100% OA)
Energy RecoveryHigh-efficiency plate heat exchanger
Dehumidification CapacityDeep dehumidification to below 40% RH supply
FiltrationMulti-stage: G4 pre-filter + F7/F9 final filter
Climate RatingT3 (55 degrees Celsius)
Communication ProtocolBACnet / Modbus RTU
Power Supply380-415V / 3Ph / 50Hz
Warranty5 Years
OriginChina
CertificationsCE, Eurovent, TUV SUD, ISO 9001/14001/45001
Applications
  • Coastal and Island Resorts: Hospitality projects where high humidity and salt air make latent load control the primary comfort challenge
  • Gulf and North African Commercial Buildings: Offices and retail centres where summer dew points exceed the capacity of room units to handle moisture
  • Tropical Office and Mixed-Use Developments: Buildings with high occupancy density requiring ventilation independent of temperature control
  • Hot-Climate Healthcare Facilities: Clinical spaces requiring filtered, dehumidified outdoor air with controlled supply conditions
  • Food Service and Hospitality Kitchens: Premises with high moisture generation needing dedicated outdoor air treatment
  • Green Building Certification Projects: Developments pursuing energy targets that require heat recovery on ventilation air
Certifications & Standards
  • CE Certified for European Market Compliance
  • Eurovent Certified Performance for Air Handling Units
  • TUV SUD Tested and Certified
  • ISO 9001 Quality Management System
  • ISO 14001 Environmental Management System
  • ISO 45001 Occupational Health and Safety Management System
  • T3 Tropical Climate Rating for Extreme Temperature Operation
  • Compliant with International Ventilation and Indoor Air Quality Standards