The Midea DC Series HRV is an eight-model heat recovery ventilator range (200–2,000 m³/h) engineered for commercial fresh-air ventilation. Its chemically treated paper core recovers both sensible and latent heat, cutting ventilation energy loss while eliminating the need for drain piping. Full DC inverter fans, four operating modes, G4 filtration and a differential-pressure filter alert come standard; optional F7/M5 filters, CO₂ sensing, centralized control and BMS gateways cover a wide range of project requirements.
| Place of Origin | China |
|---|---|
| Brand Name | Midea / Hongtai (OEM & ODM available) |
| Product Name | DC Series HRV (Heat Recovery Ventilator) |
| Model Range | HRV-D200 / D300 / D400 / D500 / D800 / D1000 / D1500 / D2000 (B and A series) |
| Air Volume | 200 – 2,000 m³/h (8 models) |
| Power Supply | 1-phase, 220–240V~50Hz (B series) / 220–240V~50/60Hz (A series) |
| Certification | CB, ISO; complies with EU 1253/2014, ErP 2009/125/EC, EU 327/2011 |
| Core Technology | Sensible & latent heat recovery with chemically treated high-efficiency paper core |
| Fan | Full DC inverter fan motors, 3-speed adjustable (Hi / Med / Low) |
| Filtration | Standard G4; optional F7 (supply) + M5 (exhaust) |
| Operating Ambient | −7℃ to +43℃; room humidity below 80% |
| Controller | Wired controller (optional); centralized controller & BMS gateway supported |
| Highlights | Up to 87.4% temperature efficiency · No drain piping needed · Free-cooling mode · CO₂ / differential-pressure sensor ready |
The Midea DC Series HRV (Heat Recovery Ventilator) delivers fresh-air ventilation with built-in heat recovery for commercial buildings. A chemically treated, high-efficiency paper core transfers both sensible and latent heat between the incoming outdoor air and the outgoing exhaust air — cooling and dehumidifying incoming air in summer, and pre-warming it in winter. The result is fresh indoor air with greatly reduced energy loss and smaller room-temperature fluctuations.
Covering a capacity range from 200 to 2,000 m³/h across eight models, the series uses full DC inverter fan motors that meet EU and ErP regulations. A slim, compact cabinet makes installation easy, while no drain piping is required thanks to simultaneous sensible and latent heat transfer at the heat exchanger.
Standard features include a G4 dust filter, a built-in differential-pressure sensor that reminds users to replace the filter, and four operating modes. Optional F7/M5 filters, a CO₂ sensor, centralized control and BMS gateways let the unit adapt to a wide range of project requirements.
The DC Series HRV combines high-efficiency heat recovery, low-energy DC fans and flexible filtration and control options in one compact cabinet. The following capabilities can be specified to match different building types and indoor-air-quality requirements.
All parameters below are measured at high (H) fan speed with the standard G4 filter; sound pressure is measured 1.5 m below the unit. "H/M/L" = High / Medium / Low.
| Parameter | HRV-D200(B) | HRV-D300(B) | HRV-D400(B) | HRV-D500(B) |
|---|---|---|---|---|
| Power supply | 1-phase 220–240V~50Hz | 1-phase 220–240V~50Hz | 1-phase 220–240V~50Hz | 1-phase 220–240V~50Hz |
| Input power H/M/L (W) | 70/45/25 | 100/55/35 | 110/70/40 | 150/95/50 |
| Nominal temperature efficiency H/M/L (%) | 79.5/81.1/83.5 | 75.5/78.8/82.5 | 77.7/79.0/81.3 | 80.6/82.2/85.5 |
| Nominal enthalpy efficiency H/M/L (%) | 75.0/77.5/79.6 | 72.1/75.0/79.3 | 73.5/75.3/78.0 | 74.0/76.6/80.5 |
| Current (A) | 0.64 | 0.84 | 0.97 | 1.2 |
| Indoor external static pressure, H+G4 (Pa) | 100 | 90 | 100 | 90 |
| Nominal air flow (m³/h) | 200 | 300 | 400 | 500 |
| Sound pressure H/M/L dB(A) | 33/29.5/25.5 | 36.5/33.5/30 | 36.5/32/28 | 36/30.5/24.5 |
| Sound power dB | 45 | 48 | 48 | 50 |
| Net dimension L×W×H (mm) | 1195×801×272 | 1195×914×272 | 1276×1204×272 | 1311×1106×390 |
| Packing size L×W×H (mm) | 1275×880×420 | 1275×994×420 | 1360×1284×420 | 1390×1244×540 |
| Net/gross weight (kg) | 53.6/70.6 | 59/77 | 71.5/91.5 | 74.4/98.6 |
| Fresh air diameter (mm) | Φ144 | Φ144 | Φ198 | Φ244 |
| Parameter | HRV-D800(B) | HRV-D1000(B) | HRV-D1500(B) | HRV-D2000(B) |
|---|---|---|---|---|
| Power supply | 1-phase 220–240V~50Hz | 1-phase 220–240V~50Hz | 1-phase 220–240V~50Hz | 1-phase 220–240V~50Hz |
| Input power H/M/L (W) | 320/170/80 | 380/210/100 | 680/320/200 | 950/500/230 |
| Nominal temperature efficiency H/M/L (%) | 78.7/82.1/86.8 | 82.8/84.0/87.4 | 75.5/78.6/80.2 | 77.2/79.5/83.4 |
| Nominal enthalpy efficiency H/M/L (%) | 72.3/75.4/79.0 | 76.0/76.0/80.1 | 69.4/71.2/74.8 | 74.7/77.0/80.6 |
| Current (A) | 2.4 | 2.9 | 3.8 | 5.7 |
| Indoor external static pressure, H+G4 (Pa) | 140 | 160 | 180 | 200 |
| Nominal air flow (m³/h) | 800 | 1,000 | 1,500 | 2,000 |
| Sound pressure H/M/L dB(A) | 42/39/34 | 44/39/33.5 | 51.5/46.5/41.5 | 53/48.5/42.5 |
| Sound power dB | 55 | 54 | 69 | 70 |
| Net dimension L×W×H (mm) | 1311×1286×390 | 1311×1526×390 | 1740×1375×615 | 1811×1575×685 |
| Packing size L×W×H (mm) | 1390×1424×540 | 1390×1670×540 | 1830×1520×770 | 1900×1720×845 |
| Net/gross weight (kg) | 80/104 | 90/112 | 181.5/213 | 208.5/245 |
| Fresh air diameter (mm) | Φ244 | Φ244 | 346×326 | 346×326 |
| Item | D200 | D300 | D400 | D500 | D800 | D1000 | D1500 | D2000 |
|---|---|---|---|---|---|---|---|---|
| MCA (A) | 1.3 | 1.7 | 2.0 | 2.5 | 5.0 | 6.0 | 8.0 | 10.0 |
| MFA (A) | 10 | 10 | 10 | 16 | 16 | 16 | 30 | 30 |
MCA = Minimum Circuit Amps; MFA = Maximum Fuse Amps.
| Item | Limit |
|---|---|
| Outdoor air temperature | −7℃ ~ +43℃ |
| Room temperature | −7℃ ~ +43℃ |
| Room humidity | Below 80% (higher may cause condensation or water blown from the outlet) |
Publishing note: The two HRV manuals list CB and ISO certifications and EU/ErP regulatory compliance. The separate "CE / TÜV / RoHS / ISO 9001 / 14001 / 45001" list seen on the V8 EasyFit page is not stated for HRV in these manuals — confirm the exact certificate scope with the factory before adding it to a live listing.
The Midea DC Series HRV is an eight-model heat recovery ventilator range (200–2,000 m³/h) engineered for commercial fresh-air ventilation. Its chemically treated paper core recovers both sensible and latent heat, cutting ventilation energy loss while eliminating the need for drain piping. Full DC inverter fans, four operating modes, G4 filtration and a differential-pressure filter alert come standard; optional F7/M5 filters, CO₂ sensing, centralized control and BMS gateways cover a wide range of project requirements.
| Place of Origin | China |
|---|---|
| Brand Name | Midea / Hongtai (OEM & ODM available) |
| Product Name | DC Series HRV (Heat Recovery Ventilator) |
| Model Range | HRV-D200 / D300 / D400 / D500 / D800 / D1000 / D1500 / D2000 (B and A series) |
| Air Volume | 200 – 2,000 m³/h (8 models) |
| Power Supply | 1-phase, 220–240V~50Hz (B series) / 220–240V~50/60Hz (A series) |
| Certification | CB, ISO; complies with EU 1253/2014, ErP 2009/125/EC, EU 327/2011 |
| Core Technology | Sensible & latent heat recovery with chemically treated high-efficiency paper core |
| Fan | Full DC inverter fan motors, 3-speed adjustable (Hi / Med / Low) |
| Filtration | Standard G4; optional F7 (supply) + M5 (exhaust) |
| Operating Ambient | −7℃ to +43℃; room humidity below 80% |
| Controller | Wired controller (optional); centralized controller & BMS gateway supported |
| Highlights | Up to 87.4% temperature efficiency · No drain piping needed · Free-cooling mode · CO₂ / differential-pressure sensor ready |
The Midea DC Series HRV (Heat Recovery Ventilator) delivers fresh-air ventilation with built-in heat recovery for commercial buildings. A chemically treated, high-efficiency paper core transfers both sensible and latent heat between the incoming outdoor air and the outgoing exhaust air — cooling and dehumidifying incoming air in summer, and pre-warming it in winter. The result is fresh indoor air with greatly reduced energy loss and smaller room-temperature fluctuations.
Covering a capacity range from 200 to 2,000 m³/h across eight models, the series uses full DC inverter fan motors that meet EU and ErP regulations. A slim, compact cabinet makes installation easy, while no drain piping is required thanks to simultaneous sensible and latent heat transfer at the heat exchanger.
Standard features include a G4 dust filter, a built-in differential-pressure sensor that reminds users to replace the filter, and four operating modes. Optional F7/M5 filters, a CO₂ sensor, centralized control and BMS gateways let the unit adapt to a wide range of project requirements.
The DC Series HRV combines high-efficiency heat recovery, low-energy DC fans and flexible filtration and control options in one compact cabinet. The following capabilities can be specified to match different building types and indoor-air-quality requirements.
All parameters below are measured at high (H) fan speed with the standard G4 filter; sound pressure is measured 1.5 m below the unit. "H/M/L" = High / Medium / Low.
| Parameter | HRV-D200(B) | HRV-D300(B) | HRV-D400(B) | HRV-D500(B) |
|---|---|---|---|---|
| Power supply | 1-phase 220–240V~50Hz | 1-phase 220–240V~50Hz | 1-phase 220–240V~50Hz | 1-phase 220–240V~50Hz |
| Input power H/M/L (W) | 70/45/25 | 100/55/35 | 110/70/40 | 150/95/50 |
| Nominal temperature efficiency H/M/L (%) | 79.5/81.1/83.5 | 75.5/78.8/82.5 | 77.7/79.0/81.3 | 80.6/82.2/85.5 |
| Nominal enthalpy efficiency H/M/L (%) | 75.0/77.5/79.6 | 72.1/75.0/79.3 | 73.5/75.3/78.0 | 74.0/76.6/80.5 |
| Current (A) | 0.64 | 0.84 | 0.97 | 1.2 |
| Indoor external static pressure, H+G4 (Pa) | 100 | 90 | 100 | 90 |
| Nominal air flow (m³/h) | 200 | 300 | 400 | 500 |
| Sound pressure H/M/L dB(A) | 33/29.5/25.5 | 36.5/33.5/30 | 36.5/32/28 | 36/30.5/24.5 |
| Sound power dB | 45 | 48 | 48 | 50 |
| Net dimension L×W×H (mm) | 1195×801×272 | 1195×914×272 | 1276×1204×272 | 1311×1106×390 |
| Packing size L×W×H (mm) | 1275×880×420 | 1275×994×420 | 1360×1284×420 | 1390×1244×540 |
| Net/gross weight (kg) | 53.6/70.6 | 59/77 | 71.5/91.5 | 74.4/98.6 |
| Fresh air diameter (mm) | Φ144 | Φ144 | Φ198 | Φ244 |
| Parameter | HRV-D800(B) | HRV-D1000(B) | HRV-D1500(B) | HRV-D2000(B) |
|---|---|---|---|---|
| Power supply | 1-phase 220–240V~50Hz | 1-phase 220–240V~50Hz | 1-phase 220–240V~50Hz | 1-phase 220–240V~50Hz |
| Input power H/M/L (W) | 320/170/80 | 380/210/100 | 680/320/200 | 950/500/230 |
| Nominal temperature efficiency H/M/L (%) | 78.7/82.1/86.8 | 82.8/84.0/87.4 | 75.5/78.6/80.2 | 77.2/79.5/83.4 |
| Nominal enthalpy efficiency H/M/L (%) | 72.3/75.4/79.0 | 76.0/76.0/80.1 | 69.4/71.2/74.8 | 74.7/77.0/80.6 |
| Current (A) | 2.4 | 2.9 | 3.8 | 5.7 |
| Indoor external static pressure, H+G4 (Pa) | 140 | 160 | 180 | 200 |
| Nominal air flow (m³/h) | 800 | 1,000 | 1,500 | 2,000 |
| Sound pressure H/M/L dB(A) | 42/39/34 | 44/39/33.5 | 51.5/46.5/41.5 | 53/48.5/42.5 |
| Sound power dB | 55 | 54 | 69 | 70 |
| Net dimension L×W×H (mm) | 1311×1286×390 | 1311×1526×390 | 1740×1375×615 | 1811×1575×685 |
| Packing size L×W×H (mm) | 1390×1424×540 | 1390×1670×540 | 1830×1520×770 | 1900×1720×845 |
| Net/gross weight (kg) | 80/104 | 90/112 | 181.5/213 | 208.5/245 |
| Fresh air diameter (mm) | Φ244 | Φ244 | 346×326 | 346×326 |
| Item | D200 | D300 | D400 | D500 | D800 | D1000 | D1500 | D2000 |
|---|---|---|---|---|---|---|---|---|
| MCA (A) | 1.3 | 1.7 | 2.0 | 2.5 | 5.0 | 6.0 | 8.0 | 10.0 |
| MFA (A) | 10 | 10 | 10 | 16 | 16 | 16 | 30 | 30 |
MCA = Minimum Circuit Amps; MFA = Maximum Fuse Amps.
| Item | Limit |
|---|---|
| Outdoor air temperature | −7℃ ~ +43℃ |
| Room temperature | −7℃ ~ +43℃ |
| Room humidity | Below 80% (higher may cause condensation or water blown from the outlet) |
Publishing note: The two HRV manuals list CB and ISO certifications and EU/ErP regulatory compliance. The separate "CE / TÜV / RoHS / ISO 9001 / 14001 / 45001" list seen on the V8 EasyFit page is not stated for HRV in these manuals — confirm the exact certificate scope with the factory before adding it to a live listing.