Ceiling-mounted Heat Recovery ERV No condensate drain required VRF interlock bypass free cooling integration via Modbus BACnet gateway

Ceiling-mounted Heat Recovery ERV No condensate drain required VRF interlock bypass free cooling integration via Modbus BACnet gateway

Detail Information
Place of Origin
China
Brand Name
OEM;MIDEA
Certification
CB,ISO
Product Name:
Midea DC Series HRV
Airflow:
200 M³/h-2000 M³/h
Dimensions L X W X H:
1,195 X 801 X 272 Mm-1,811 X 1,575 X 685 Mm
Net / Gross Weight:
53.6 / 70.6 Kg-208.5 / 245 Kg
Spigot:
144 Mm-346 X 326 Mm
External Static Pressure:
100 Pa-200 Pa
Condensate Drain:
Not Required/PVC Required
Highlight:

Ceiling-mounted Heat Recovery ERV

,

No condensate drain ERV

,

VRF interlock ERV

Product Description
Ceiling-Mounted Heat Recovery ERV — No Condensate Drain Required, VRF Interlock, Bypass Free Cooling, Modbus & BACnet Gateway Integration

The drain pipe is the part that ruins the ceiling.

Ask an installer what they remember about a recovery ventilator and they will rarely mention efficiency. They will mention the drain.

A conventional heat exchanger condenses. Moisture from the exhaust stream collects on the core, drips into a pan, and the pan needs a slope, a trap, a route to a floor drain and, in most buildings, a hole in a ceiling that somebody has to justify to the architect. On a hotel floor with forty rooms, that is forty drainage points, forty chances for a blocked trap, and one leak that ends up on a guest's ceiling.

Six of the eight models in the DC series do not need a drain at all. That single fact changes how the equipment is installed, and it is worth understanding why it is possible rather than taking it on trust.

Why Six Models Need No Condensate Drain

The core is a chemically treated paper exchanger. Moisture passes through it as vapour rather than condensing on the surface, so the exhaust stream leaves carrying its humidity instead of depositing it inside the casing.

This works up to 1,000 m³/h. Above that, the physical scale of the core changes the behaviour and the 1,500 and 2,000 m³/h models require a PVC condensate connection.

The practical consequence is a ceiling void with no drain pipe, no trap, no slope and no fall to a floor drain. On the 200 to 1,000 m³/h models, installation reduces to three actions: hang the unit, connect the ducts, connect single-phase power. Nothing else needs to be coordinated with the drainage trade, and there is no trap to go dry in a building that sits empty over a holiday.

Casing Depth and What It Means for the Ceiling Void

Casing depth across the range runs from 272 mm to 685 mm, and it steps with airflow rather than staying constant.

Airflow band Models Casing depth
200 to 400 m³/h HRV-D200, D300, D400 272 mm
500 to 1,000 m³/h HRV-D500, D800, D1000 390 mm
1,500 to 2,000 m³/h HRV-D1500, D2000 615 to 685 mm

The 272 mm casing is the number that matters in residential and hotel work, where a suspended ceiling is often 300 mm below slab. Three models fit that void with clearance for the hangers. The 390 mm models suit a 450 mm ceiling or a service corridor, and the two largest units belong in a plant room rather than a corridor ceiling.

Length and width matter as much as depth on the larger units: the 2,000 m³/h model is 1,811 mm long and 1,575 mm wide, which is a plant room footprint, not a ceiling void. Check the access route before the unit arrives, not after.

Duct Connections and External Static Pressure

Duct spigot sizes step with airflow and are circular up to 1,000 m³/h, then rectangular.

Models Spigot
D200, D300 144 mm
D400 198 mm
D500, D800, D1000 244 mm
D1500, D2000 346 x 326 mm

External static pressure ranges from 90 Pa on the smaller units to 200 Pa on the 2,000 m³/h model. That is the budget available for ducts, bends, filters and grilles, and it is the number to design against. A unit selected on airflow alone, with a duct run that eats 180 Pa, will deliver less air than the schedule says and the installer will be the one explaining it.

All models carry three fan speeds, so a marginal duct run can be recovered by moving up a speed. It costs power, not rework.

Bypass Damper and the Cold Weather Limit

The bypass damper opens when outdoor temperature is below indoor temperature, sending incoming air around the core instead of through it. In shoulder seasons this provides free cooling with no compressor running.

The operating range is -7 °C to +43 °C outdoor and indoor, with indoor humidity below 80 percent. Below -7 °C, the unit is outside its declared envelope, and projects in colder climates need a pre-heat strategy rather than a bigger ventilator. This is a design decision, not an installation detail, and it is better settled at tender stage.

Electrical Supply and OEM Voltage Options

Every model is single-phase 220 to 240 V, 50 Hz, with a 3-core 2.5 mm² supply cable. Current draw runs from 0.64 A on the 200 m³/h model to 5.7 A on the 2,000 m³/h model, so a single dedicated circuit covers the smaller units and the largest ones need their own.

For export projects on other grid standards, the manufacturer supports OEM/ODM voltage customisation from 180 to 440 V at 50 or 60 Hz. That is a factory option, not a field modification, and it needs to be specified on the order.

VRF Interlock and BMS Communication

This is where a ventilator stops being a standalone box and becomes part of a system.

PQE Port

The unit interlocks with Midea VRF indoor units and starts and stops with the air conditioning. When the floor is unoccupied and the VRF is off, the ventilator follows. That single link removes most of the wasted running hours on a typical office floor.

Controllers

The KJR-27B/E wall controller covers five modes, four fan speeds including a sleep setting, and a timer, with up to 16 units on one controller. The WDC-120G/WK(A) adds CO2 display, filter status, group control, weekly scheduling, VRF interlock and delayed shutdown.

Central Control

CCM-180A/WS(A) and CCM-270B/WS(A) bring ventilation and VRF under one interface across floors.

BMS Gateways

GW-MOD(A) delivers Modbus and IMMP-BAC delivers BACnet. Both present the unit as a clean set of points to the building management contractor, rather than as a proprietary device that needs a separate front end.

For a controls contractor, the useful question is not whether the unit supports a protocol but whether the point list is complete at handover. Confirm the gateway model on the order, because it is a factory-fitted option and not something that can be added later without a return visit.

Commissioning Sequence
  1. Confirm the unit is level and the hangers are rated for the operating weight, not the net weight. Gross weight on the 2,000 m³/h model is 245 kg.
  2. Check the duct connections are sealed before the ceiling closes. Access panels on both filter sides are the point most often forgotten.
  3. Power up and confirm fan rotation and the three speed steps at the controller.
  4. Verify the bypass damper travels fully open and fully closed. A damper that only half opens reads as a control fault later.
  5. Set the CO2 thresholds if the sensor is fitted: 450 ppm stop, 550 low, 800 medium, 1,000 high.
  6. Confirm the BMS points read correctly at the head end before handover, not after.
Five Installation Mistakes Worth Avoiding
  • Selecting on airflow without checking static pressure. The duct run decides whether the unit delivers its nominal air.
  • Mounting a 390 mm unit in a 300 mm void. Depth steps with airflow. Check the model, not the series.
  • Forgetting the 1,500 and 2,000 m³/h units need a drain. Six models do not. Two do, and those two are the ones that end up in plant rooms where the drain is easy to miss.
  • Assuming the gateway is included. Modbus and BACnet interfaces are factory options. Specifying them after the order is placed means a second shipment.
  • Closing the ceiling before the filters are checked. Both filter banks need access. Filter replacement is a routine task, not a service call.
Installation Data for All Eight Models
Model Airflow Dimensions L x W x H Net / gross weight Spigot External static pressure Condensate drain
HRV-D200(B) 200 m³/h 1,195 x 801 x 272 mm 53.6 / 70.6 kg 144 mm 100 Pa Not required
HRV-D300(B) 300 m³/h 1,195 x 914 x 272 mm 59 / 77 kg 144 mm 90 Pa Not required
HRV-D400(B) 400 m³/h 1,276 x 1,204 x 272 mm 71.5 / 91.5 kg 198 mm 100 Pa Not required
HRV-D500(B) 500 m³/h 1,311 x 1,106 x 390 mm 74.4 / 98.6 kg 244 mm 90 Pa Not required
HRV-D800(B) 800 m³/h 1,311 x 1,286 x 390 mm 80 / 104 kg 244 mm 140 Pa Not required
HRV-D1000(B) 1,000 m³/h 1,311 x 1,526 x 390 mm 90 / 112 kg 244 mm 160 Pa Not required
HRV-D1500(B) 1,500 m³/h 1,740 x 1,375 x 615 mm 181.5 / 213 kg 346 x 326 mm 180 Pa PVC required
HRV-D2000(B) 2,000 m³/h 1,811 x 1,575 x 685 mm 208.5 / 245 kg 346 x 326 mm 200 Pa PVC required

All models: single-phase 220 to 240 V, 50 Hz, 3-core 2.5 mm² supply cable. Operating range -7 °C to +43 °C, indoor humidity below 80 percent.

Maintenance Overview

Filters wash or vacuum clean. The core should be vacuumed roughly every two years and must never be washed with water, because the treatment that allows vapour transfer is not designed to survive it. Fans are checked every six months. A differential pressure sensor monitors filter resistance and raises a reminder through the controller before airflow drops, so the schedule is driven by condition rather than by calendar.

Get the Installation Right the First Time

Send us the ceiling void depth, the duct route and the destination country. We will confirm the model, the spigot size, the static pressure margin and whether the gateway you need is factory-fitted, before the order is placed.

Ceiling-mounted heat recovery ERV unit exterior view showing casing and duct spigot connections Heat recovery ventilator internal core and filter access panel detail for maintenance
Products
PRODUCTS DETAILS
Ceiling-mounted Heat Recovery ERV No condensate drain required VRF interlock bypass free cooling integration via Modbus BACnet gateway
Detail Information
Place of Origin
China
Brand Name
OEM;MIDEA
Certification
CB,ISO
Product Name:
Midea DC Series HRV
Airflow:
200 M³/h-2000 M³/h
Dimensions L X W X H:
1,195 X 801 X 272 Mm-1,811 X 1,575 X 685 Mm
Net / Gross Weight:
53.6 / 70.6 Kg-208.5 / 245 Kg
Spigot:
144 Mm-346 X 326 Mm
External Static Pressure:
100 Pa-200 Pa
Condensate Drain:
Not Required/PVC Required
Highlight

Ceiling-mounted Heat Recovery ERV

,

No condensate drain ERV

,

VRF interlock ERV

Product Description
Ceiling-Mounted Heat Recovery ERV — No Condensate Drain Required, VRF Interlock, Bypass Free Cooling, Modbus & BACnet Gateway Integration

The drain pipe is the part that ruins the ceiling.

Ask an installer what they remember about a recovery ventilator and they will rarely mention efficiency. They will mention the drain.

A conventional heat exchanger condenses. Moisture from the exhaust stream collects on the core, drips into a pan, and the pan needs a slope, a trap, a route to a floor drain and, in most buildings, a hole in a ceiling that somebody has to justify to the architect. On a hotel floor with forty rooms, that is forty drainage points, forty chances for a blocked trap, and one leak that ends up on a guest's ceiling.

Six of the eight models in the DC series do not need a drain at all. That single fact changes how the equipment is installed, and it is worth understanding why it is possible rather than taking it on trust.

Why Six Models Need No Condensate Drain

The core is a chemically treated paper exchanger. Moisture passes through it as vapour rather than condensing on the surface, so the exhaust stream leaves carrying its humidity instead of depositing it inside the casing.

This works up to 1,000 m³/h. Above that, the physical scale of the core changes the behaviour and the 1,500 and 2,000 m³/h models require a PVC condensate connection.

The practical consequence is a ceiling void with no drain pipe, no trap, no slope and no fall to a floor drain. On the 200 to 1,000 m³/h models, installation reduces to three actions: hang the unit, connect the ducts, connect single-phase power. Nothing else needs to be coordinated with the drainage trade, and there is no trap to go dry in a building that sits empty over a holiday.

Casing Depth and What It Means for the Ceiling Void

Casing depth across the range runs from 272 mm to 685 mm, and it steps with airflow rather than staying constant.

Airflow band Models Casing depth
200 to 400 m³/h HRV-D200, D300, D400 272 mm
500 to 1,000 m³/h HRV-D500, D800, D1000 390 mm
1,500 to 2,000 m³/h HRV-D1500, D2000 615 to 685 mm

The 272 mm casing is the number that matters in residential and hotel work, where a suspended ceiling is often 300 mm below slab. Three models fit that void with clearance for the hangers. The 390 mm models suit a 450 mm ceiling or a service corridor, and the two largest units belong in a plant room rather than a corridor ceiling.

Length and width matter as much as depth on the larger units: the 2,000 m³/h model is 1,811 mm long and 1,575 mm wide, which is a plant room footprint, not a ceiling void. Check the access route before the unit arrives, not after.

Duct Connections and External Static Pressure

Duct spigot sizes step with airflow and are circular up to 1,000 m³/h, then rectangular.

Models Spigot
D200, D300 144 mm
D400 198 mm
D500, D800, D1000 244 mm
D1500, D2000 346 x 326 mm

External static pressure ranges from 90 Pa on the smaller units to 200 Pa on the 2,000 m³/h model. That is the budget available for ducts, bends, filters and grilles, and it is the number to design against. A unit selected on airflow alone, with a duct run that eats 180 Pa, will deliver less air than the schedule says and the installer will be the one explaining it.

All models carry three fan speeds, so a marginal duct run can be recovered by moving up a speed. It costs power, not rework.

Bypass Damper and the Cold Weather Limit

The bypass damper opens when outdoor temperature is below indoor temperature, sending incoming air around the core instead of through it. In shoulder seasons this provides free cooling with no compressor running.

The operating range is -7 °C to +43 °C outdoor and indoor, with indoor humidity below 80 percent. Below -7 °C, the unit is outside its declared envelope, and projects in colder climates need a pre-heat strategy rather than a bigger ventilator. This is a design decision, not an installation detail, and it is better settled at tender stage.

Electrical Supply and OEM Voltage Options

Every model is single-phase 220 to 240 V, 50 Hz, with a 3-core 2.5 mm² supply cable. Current draw runs from 0.64 A on the 200 m³/h model to 5.7 A on the 2,000 m³/h model, so a single dedicated circuit covers the smaller units and the largest ones need their own.

For export projects on other grid standards, the manufacturer supports OEM/ODM voltage customisation from 180 to 440 V at 50 or 60 Hz. That is a factory option, not a field modification, and it needs to be specified on the order.

VRF Interlock and BMS Communication

This is where a ventilator stops being a standalone box and becomes part of a system.

PQE Port

The unit interlocks with Midea VRF indoor units and starts and stops with the air conditioning. When the floor is unoccupied and the VRF is off, the ventilator follows. That single link removes most of the wasted running hours on a typical office floor.

Controllers

The KJR-27B/E wall controller covers five modes, four fan speeds including a sleep setting, and a timer, with up to 16 units on one controller. The WDC-120G/WK(A) adds CO2 display, filter status, group control, weekly scheduling, VRF interlock and delayed shutdown.

Central Control

CCM-180A/WS(A) and CCM-270B/WS(A) bring ventilation and VRF under one interface across floors.

BMS Gateways

GW-MOD(A) delivers Modbus and IMMP-BAC delivers BACnet. Both present the unit as a clean set of points to the building management contractor, rather than as a proprietary device that needs a separate front end.

For a controls contractor, the useful question is not whether the unit supports a protocol but whether the point list is complete at handover. Confirm the gateway model on the order, because it is a factory-fitted option and not something that can be added later without a return visit.

Commissioning Sequence
  1. Confirm the unit is level and the hangers are rated for the operating weight, not the net weight. Gross weight on the 2,000 m³/h model is 245 kg.
  2. Check the duct connections are sealed before the ceiling closes. Access panels on both filter sides are the point most often forgotten.
  3. Power up and confirm fan rotation and the three speed steps at the controller.
  4. Verify the bypass damper travels fully open and fully closed. A damper that only half opens reads as a control fault later.
  5. Set the CO2 thresholds if the sensor is fitted: 450 ppm stop, 550 low, 800 medium, 1,000 high.
  6. Confirm the BMS points read correctly at the head end before handover, not after.
Five Installation Mistakes Worth Avoiding
  • Selecting on airflow without checking static pressure. The duct run decides whether the unit delivers its nominal air.
  • Mounting a 390 mm unit in a 300 mm void. Depth steps with airflow. Check the model, not the series.
  • Forgetting the 1,500 and 2,000 m³/h units need a drain. Six models do not. Two do, and those two are the ones that end up in plant rooms where the drain is easy to miss.
  • Assuming the gateway is included. Modbus and BACnet interfaces are factory options. Specifying them after the order is placed means a second shipment.
  • Closing the ceiling before the filters are checked. Both filter banks need access. Filter replacement is a routine task, not a service call.
Installation Data for All Eight Models
Model Airflow Dimensions L x W x H Net / gross weight Spigot External static pressure Condensate drain
HRV-D200(B) 200 m³/h 1,195 x 801 x 272 mm 53.6 / 70.6 kg 144 mm 100 Pa Not required
HRV-D300(B) 300 m³/h 1,195 x 914 x 272 mm 59 / 77 kg 144 mm 90 Pa Not required
HRV-D400(B) 400 m³/h 1,276 x 1,204 x 272 mm 71.5 / 91.5 kg 198 mm 100 Pa Not required
HRV-D500(B) 500 m³/h 1,311 x 1,106 x 390 mm 74.4 / 98.6 kg 244 mm 90 Pa Not required
HRV-D800(B) 800 m³/h 1,311 x 1,286 x 390 mm 80 / 104 kg 244 mm 140 Pa Not required
HRV-D1000(B) 1,000 m³/h 1,311 x 1,526 x 390 mm 90 / 112 kg 244 mm 160 Pa Not required
HRV-D1500(B) 1,500 m³/h 1,740 x 1,375 x 615 mm 181.5 / 213 kg 346 x 326 mm 180 Pa PVC required
HRV-D2000(B) 2,000 m³/h 1,811 x 1,575 x 685 mm 208.5 / 245 kg 346 x 326 mm 200 Pa PVC required

All models: single-phase 220 to 240 V, 50 Hz, 3-core 2.5 mm² supply cable. Operating range -7 °C to +43 °C, indoor humidity below 80 percent.

Maintenance Overview

Filters wash or vacuum clean. The core should be vacuumed roughly every two years and must never be washed with water, because the treatment that allows vapour transfer is not designed to survive it. Fans are checked every six months. A differential pressure sensor monitors filter resistance and raises a reminder through the controller before airflow drops, so the schedule is driven by condition rather than by calendar.

Get the Installation Right the First Time

Send us the ceiling void depth, the duct route and the destination country. We will confirm the model, the spigot size, the static pressure margin and whether the gateway you need is factory-fitted, before the order is placed.

Ceiling-mounted heat recovery ERV unit exterior view showing casing and duct spigot connections Heat recovery ventilator internal core and filter access panel detail for maintenance