Ceiling Heat Recovery Ventilator Six Sizes Without a Drain 272 mm Slim HRV Three Models for 300 mm Ceiling Voids HRV Installation Spigot Sizes Static Pressure and Drains

Ceiling Heat Recovery Ventilator Six Sizes Without a Drain 272 mm Slim HRV Three Models for 300 mm Ceiling Voids HRV Installation Spigot Sizes Static Pressure and Drains

Detail Information
Place of Origin
China
Brand Name
OEM;MIDEA
Certification
CB,ISO
Product Name:
Midea DC Series HRV
Airflow:
200 M³/h-2000 M³/h
Dimensions L X W X H:
1,195 X 801 X 272 Mm-1,811 X 1,575 X 685 Mm
Net / Gross Weight:
53.6 / 70.6 Kg-208.5 / 245 Kg
Spigot:
144 Mm-346 X 326 Mm
External Static Pressure:
100 Pa-200 Pa
Condensate Drain:
Not Required/PVC Required
Highlight:

Slim ceiling HRV ventilator

,

Drainless HRV six sizes

,

HRV for 300 mm ceiling voids

Product Description
Product Overview: Ceiling Heat Recovery Ventilators Built Around the Ceiling Void

Ceiling voids are where ventilation projects fail. The unit itself is rarely the problem; the condensate line, the casing depth and the duct transitions are. The DC Series is laid out with that in mind. Eight models span 200 to 2,000 m³/h, with casing depths of 272 mm, 390 mm and 615 to 685 mm in three steps, so a coordination drawing can place the right box in the right void without redesigning the ceiling.

Six of the eight sizes need no condensate drain at all. The heat exchange core is made of specially treated paper that transfers moisture as vapour rather than condensing it, so sizes from 200 to 1,000 m³/h have no drain pan, no slope to design and no trap to prime. Only the 1,500 and 2,000 m³/h models require a PVC drain connection. On a project with dozens of units, that removes the single most common source of ceiling rework.

Integration follows the same logic. Round spigots from Φ144 to Φ244 mm on the small and mid sizes, rectangular 346×326 mm connections on the two largest, external static pressure from 90 to 200 Pa to cover real duct runs, single-phase 220-240 V power across the range, and a PQE port that interlocks the unit with Midea VRF indoor units. Centralised controllers and Modbus or BACnet gateways hand the whole floor to the BMS contractor in one package.

Key Selling Points
  • No Drain on Six of Eight Sizes — 200 to 1,000 m³/h models need no condensate line; only 1,500 and 2,000 m³/h require PVC drainage.
  • 272 mm Casing on Three Models — HRV-D200, D300 and D400 fit 300 mm ceiling voids; 390 mm for 500 to 1,000 m³/h; 615 to 685 mm for the two largest.
  • Four Spigot Sizes Across the Range — Φ144, Φ198 and Φ244 mm round connections plus 346×326 mm rectangular on the large models.
  • External Static Pressure 90–200 Pa — Enough head for real duct runs and grille pressure drops without oversizing the fan.
  • Single-Phase Power Throughout — 220-240 V, 50 Hz, 3-core 2.5 mm² cable on all eight sizes; no three-phase supply to arrange.
  • Bypass Damper for Free Cooling — Fresh air routes around the core when outdoor temperature is lower, with no compressor runtime.
  • VRF Interlock via PQE Port — Start and stop synchronised with Midea VRF indoor units; one controller can manage up to 16 units.
  • BMS Handover Ready — GW-MOD(A) for Modbus and IMMP-BAC for BACnet, plus CCM-180A/WS(A) and CCM-270B/WS(A) centralised controllers.
Drain Requirements by Size
Airflow Models Condensate Drain
200–1,000 m³/h HRV-D200, D300, D400, D500, D800, D1000 Not required — moisture transfers through the paper core as vapour
1,500–2,000 m³/h HRV-D1500, D2000 PVC drain connection required, with slope and trap
Casing Depth and Ceiling Void
Airflow Models Casing Depth Overall Dimensions (L × W × H)
200–400 m³/h HRV-D200, D300, D400 272 mm 1195×801, 1195×914, 1276×1204 mm
500–1,000 m³/h HRV-D500, D800, D1000 390 mm 1311×1106, 1311×1286, 1311×1526 mm
1,500–2,000 m³/h HRV-D1500, D2000 615–685 mm 1740×1375, 1811×1575 mm

Allow additional space for suspension rods, filter access and duct transitions. Filter replacement is from the service panel, so the access side must stay clear.

Duct Connections and External Static Pressure
Airflow Spigot External Static Pressure
200–300 m³/h Φ144 mm 100 / 90 Pa
400 m³/h Φ198 mm 100 Pa
500–1,000 m³/h Φ244 mm 90 / 140 / 160 Pa
1,500–2,000 m³/h 346×326 mm 180 / 200 Pa

Static pressure figures are the available head at rated airflow. Deduct the resistance of filters, flexible connections, silencers, duct runs and grilles before confirming the design point. Where the duct run is long or heavily fitted, size the unit on the next model up rather than adding a booster.

Electrical Requirements
  • Supply: single-phase 220-240 V, 50 Hz on all eight sizes.
  • Cable: 3-core 2.5 mm².
  • Current: 0.64 A on HRV-D200 up to 5.7 A on HRV-D2000.
  • Controller wiring: low-voltage control cable from the wired controller to the unit; one KJR-27B/E controller can run up to 16 units.
  • Isolation: local isolator adjacent to the unit, accessible from the access panel.
Control, Interlock and BMS Integration
  • KJR-27B/E wired controller — Five modes, four fan speeds including sleep, timer on/off; one controller for up to 16 units.
  • WDC-120G/WK(A) wired controller — Adds CO2 display, filter indicator, group control, weekly timer, VRF interlock, delayed shutdown and parameter query.
  • PQE port — Interlocks the HRV with Midea VRF indoor units so ventilation follows air conditioning.
  • CCM-180A/WS(A) and CCM-270B/WS(A) — Centralised panels managing HRV and VRF together by floor and zone.
  • GW-MOD(A) / IMMP-BAC — Modbus RTU and BACnet gateways for BMS handover.
  • Optional CO2 sensor — Four thresholds: stop below 450 ppm, low at 550, medium at 800, high at 1,000 ppm.
Installation Sequence
  1. Check the void against the drawing — Confirm casing depth plus suspension and access clearance before the unit is lifted.
  2. Set the suspension — Threaded rods at the four hanger points, unit level in both axes; allow for filter removal on the service side.
  3. Connect the ducts — Round spigots with flexible connectors at the unit to isolate vibration; rectangular transitions on the large models.
  4. Confirm the drain decision — Sizes up to 1,000 m³/h need no drain; 1,500 and 2,000 m³/h need PVC with slope and trap.
  5. Wire power and control — Single-phase 220-240 V, 3-core 2.5 mm², local isolator, control cable to the controller position.
  6. Commission — Set airflow at each terminal, verify bypass operation against outdoor temperature, test the interlock and log the static pressure at the design point.
Maintenance
  • Filters — G4 standard on both streams, washable or vacuum-cleanable; F7 supply and M5 exhaust optional.
  • Heat exchange core — Vacuum approximately every two years; never wash with water.
  • Fans — Inspect every six months.
  • Filter reminder — The built-in differential pressure sensor flags replacement on the controller before airflow drops.
  • Access — Service panel must remain reachable after the ceiling is closed; plan the access hatch at coordination stage.
Technical Data
Model Airflow Dimensions L × W × H Net / Gross Weight Spigot External Static Pressure Current Sound Pressure (H/M/L)
HRV-D200(B) 200 m³/h 1195×801×272 mm 53.6 / 70.6 kg Φ144 mm 100 Pa 0.64 A 33/29.5/25.5 dB(A)
HRV-D300(B) 300 m³/h 1195×914×272 mm 59 / 77 kg Φ144 mm 90 Pa 0.84 A 36.5/33.5/30 dB(A)
HRV-D400(B) 400 m³/h 1276×1204×272 mm 71.5 / 91.5 kg Φ198 mm 100 Pa 0.97 A 36.5/32/28 dB(A)
HRV-D500(B) 500 m³/h 1311×1106×390 mm 74.4 / 98.6 kg Φ244 mm 90 Pa 1.2 A 36/30.5/24.5 dB(A)
HRV-D800(B) 800 m³/h 1311×1286×390 mm 80 / 104 kg Φ244 mm 140 Pa 2.4 A 42/39/34 dB(A)
HRV-D1000(B) 1,000 m³/h 1311×1526×390 mm 90 / 112 kg Φ244 mm 160 Pa 2.9 A 44/39/33.5 dB(A)
HRV-D1500(B) 1,500 m³/h 1740×1375×615 mm 181.5 / 213 kg 346×326 mm 180 Pa 3.8 A 51.5/46.5/41.5 dB(A)
HRV-D2000(B) 2,000 m³/h 1811×1575×685 mm 208.5 / 245 kg 346×326 mm 200 Pa 5.7 A 53/48.5/42.5 dB(A)

Notes: three fan speeds on all models, single values measured at high speed. Sound pressure measured 1.5 m below the unit. Operating range -7 °C to +43 °C, indoor humidity below 80%. Only HRV-D1500 and D2000 require a PVC drain. Power supply 220-240 V, single-phase, 50 Hz on all sizes.

Frequently Asked Questions
Does the unit need a condensate drain?

Sizes from 200 to 1,000 m³/h need no drain at all, because the paper core transfers moisture as vapour. Only the 1,500 and 2,000 m³/h models require a PVC drain connection with slope and trap.

What ceiling depth do I need?

272 mm casing for HRV-D200, D300 and D400; 390 mm for D500, D800 and D1000; 615 to 685 mm for D1500 and D2000. Add clearance for suspension rods and filter access.

What duct sizes does the range use?

Φ144 mm on 200 and 300 m³/h, Φ198 mm on 400 m³/h, Φ244 mm on 500 to 1,000 m³/h, and rectangular 346×326 mm on 1,500 and 2,000 m³/h.

How much static pressure is available?

From 90 Pa on the smaller models to 200 Pa on HRV-D2000. Deduct filter, silencer, duct and grille resistance before confirming the design point.

Can it run in cold climates?

The operating range is -7 °C to +43 °C for both outdoor and indoor air, with indoor humidity below 80%. Below that, plan pre-heating or a frost protection strategy at design stage.

How does it interlock with a VRF system?

The PQE port synchronises start and stop with Midea VRF indoor units. One KJR-27B/E controller can manage up to 16 units, and the CCM centralised controllers bring HRV and VRF onto one panel.

Is the BMS gateway included?

GW-MOD(A) for Modbus RTU and IMMP-BAC for BACnet are available as options. Specify the protocol at order stage so the gateway ships with the units rather than as a later retrofit.

Product Gallery
Related Search Terms

ceiling heat recovery ventilator installation, hrv without drain pipe, slim hrv 272mm, erv duct connection sizes, hrv external static pressure, vrf interlock ventilation, bacnet hrv gateway, ceiling void hrv dimensions

Products
PRODUCTS DETAILS
Ceiling Heat Recovery Ventilator Six Sizes Without a Drain 272 mm Slim HRV Three Models for 300 mm Ceiling Voids HRV Installation Spigot Sizes Static Pressure and Drains
Detail Information
Place of Origin
China
Brand Name
OEM;MIDEA
Certification
CB,ISO
Product Name:
Midea DC Series HRV
Airflow:
200 M³/h-2000 M³/h
Dimensions L X W X H:
1,195 X 801 X 272 Mm-1,811 X 1,575 X 685 Mm
Net / Gross Weight:
53.6 / 70.6 Kg-208.5 / 245 Kg
Spigot:
144 Mm-346 X 326 Mm
External Static Pressure:
100 Pa-200 Pa
Condensate Drain:
Not Required/PVC Required
Highlight

Slim ceiling HRV ventilator

,

Drainless HRV six sizes

,

HRV for 300 mm ceiling voids

Product Description
Product Overview: Ceiling Heat Recovery Ventilators Built Around the Ceiling Void

Ceiling voids are where ventilation projects fail. The unit itself is rarely the problem; the condensate line, the casing depth and the duct transitions are. The DC Series is laid out with that in mind. Eight models span 200 to 2,000 m³/h, with casing depths of 272 mm, 390 mm and 615 to 685 mm in three steps, so a coordination drawing can place the right box in the right void without redesigning the ceiling.

Six of the eight sizes need no condensate drain at all. The heat exchange core is made of specially treated paper that transfers moisture as vapour rather than condensing it, so sizes from 200 to 1,000 m³/h have no drain pan, no slope to design and no trap to prime. Only the 1,500 and 2,000 m³/h models require a PVC drain connection. On a project with dozens of units, that removes the single most common source of ceiling rework.

Integration follows the same logic. Round spigots from Φ144 to Φ244 mm on the small and mid sizes, rectangular 346×326 mm connections on the two largest, external static pressure from 90 to 200 Pa to cover real duct runs, single-phase 220-240 V power across the range, and a PQE port that interlocks the unit with Midea VRF indoor units. Centralised controllers and Modbus or BACnet gateways hand the whole floor to the BMS contractor in one package.

Key Selling Points
  • No Drain on Six of Eight Sizes — 200 to 1,000 m³/h models need no condensate line; only 1,500 and 2,000 m³/h require PVC drainage.
  • 272 mm Casing on Three Models — HRV-D200, D300 and D400 fit 300 mm ceiling voids; 390 mm for 500 to 1,000 m³/h; 615 to 685 mm for the two largest.
  • Four Spigot Sizes Across the Range — Φ144, Φ198 and Φ244 mm round connections plus 346×326 mm rectangular on the large models.
  • External Static Pressure 90–200 Pa — Enough head for real duct runs and grille pressure drops without oversizing the fan.
  • Single-Phase Power Throughout — 220-240 V, 50 Hz, 3-core 2.5 mm² cable on all eight sizes; no three-phase supply to arrange.
  • Bypass Damper for Free Cooling — Fresh air routes around the core when outdoor temperature is lower, with no compressor runtime.
  • VRF Interlock via PQE Port — Start and stop synchronised with Midea VRF indoor units; one controller can manage up to 16 units.
  • BMS Handover Ready — GW-MOD(A) for Modbus and IMMP-BAC for BACnet, plus CCM-180A/WS(A) and CCM-270B/WS(A) centralised controllers.
Drain Requirements by Size
Airflow Models Condensate Drain
200–1,000 m³/h HRV-D200, D300, D400, D500, D800, D1000 Not required — moisture transfers through the paper core as vapour
1,500–2,000 m³/h HRV-D1500, D2000 PVC drain connection required, with slope and trap
Casing Depth and Ceiling Void
Airflow Models Casing Depth Overall Dimensions (L × W × H)
200–400 m³/h HRV-D200, D300, D400 272 mm 1195×801, 1195×914, 1276×1204 mm
500–1,000 m³/h HRV-D500, D800, D1000 390 mm 1311×1106, 1311×1286, 1311×1526 mm
1,500–2,000 m³/h HRV-D1500, D2000 615–685 mm 1740×1375, 1811×1575 mm

Allow additional space for suspension rods, filter access and duct transitions. Filter replacement is from the service panel, so the access side must stay clear.

Duct Connections and External Static Pressure
Airflow Spigot External Static Pressure
200–300 m³/h Φ144 mm 100 / 90 Pa
400 m³/h Φ198 mm 100 Pa
500–1,000 m³/h Φ244 mm 90 / 140 / 160 Pa
1,500–2,000 m³/h 346×326 mm 180 / 200 Pa

Static pressure figures are the available head at rated airflow. Deduct the resistance of filters, flexible connections, silencers, duct runs and grilles before confirming the design point. Where the duct run is long or heavily fitted, size the unit on the next model up rather than adding a booster.

Electrical Requirements
  • Supply: single-phase 220-240 V, 50 Hz on all eight sizes.
  • Cable: 3-core 2.5 mm².
  • Current: 0.64 A on HRV-D200 up to 5.7 A on HRV-D2000.
  • Controller wiring: low-voltage control cable from the wired controller to the unit; one KJR-27B/E controller can run up to 16 units.
  • Isolation: local isolator adjacent to the unit, accessible from the access panel.
Control, Interlock and BMS Integration
  • KJR-27B/E wired controller — Five modes, four fan speeds including sleep, timer on/off; one controller for up to 16 units.
  • WDC-120G/WK(A) wired controller — Adds CO2 display, filter indicator, group control, weekly timer, VRF interlock, delayed shutdown and parameter query.
  • PQE port — Interlocks the HRV with Midea VRF indoor units so ventilation follows air conditioning.
  • CCM-180A/WS(A) and CCM-270B/WS(A) — Centralised panels managing HRV and VRF together by floor and zone.
  • GW-MOD(A) / IMMP-BAC — Modbus RTU and BACnet gateways for BMS handover.
  • Optional CO2 sensor — Four thresholds: stop below 450 ppm, low at 550, medium at 800, high at 1,000 ppm.
Installation Sequence
  1. Check the void against the drawing — Confirm casing depth plus suspension and access clearance before the unit is lifted.
  2. Set the suspension — Threaded rods at the four hanger points, unit level in both axes; allow for filter removal on the service side.
  3. Connect the ducts — Round spigots with flexible connectors at the unit to isolate vibration; rectangular transitions on the large models.
  4. Confirm the drain decision — Sizes up to 1,000 m³/h need no drain; 1,500 and 2,000 m³/h need PVC with slope and trap.
  5. Wire power and control — Single-phase 220-240 V, 3-core 2.5 mm², local isolator, control cable to the controller position.
  6. Commission — Set airflow at each terminal, verify bypass operation against outdoor temperature, test the interlock and log the static pressure at the design point.
Maintenance
  • Filters — G4 standard on both streams, washable or vacuum-cleanable; F7 supply and M5 exhaust optional.
  • Heat exchange core — Vacuum approximately every two years; never wash with water.
  • Fans — Inspect every six months.
  • Filter reminder — The built-in differential pressure sensor flags replacement on the controller before airflow drops.
  • Access — Service panel must remain reachable after the ceiling is closed; plan the access hatch at coordination stage.
Technical Data
Model Airflow Dimensions L × W × H Net / Gross Weight Spigot External Static Pressure Current Sound Pressure (H/M/L)
HRV-D200(B) 200 m³/h 1195×801×272 mm 53.6 / 70.6 kg Φ144 mm 100 Pa 0.64 A 33/29.5/25.5 dB(A)
HRV-D300(B) 300 m³/h 1195×914×272 mm 59 / 77 kg Φ144 mm 90 Pa 0.84 A 36.5/33.5/30 dB(A)
HRV-D400(B) 400 m³/h 1276×1204×272 mm 71.5 / 91.5 kg Φ198 mm 100 Pa 0.97 A 36.5/32/28 dB(A)
HRV-D500(B) 500 m³/h 1311×1106×390 mm 74.4 / 98.6 kg Φ244 mm 90 Pa 1.2 A 36/30.5/24.5 dB(A)
HRV-D800(B) 800 m³/h 1311×1286×390 mm 80 / 104 kg Φ244 mm 140 Pa 2.4 A 42/39/34 dB(A)
HRV-D1000(B) 1,000 m³/h 1311×1526×390 mm 90 / 112 kg Φ244 mm 160 Pa 2.9 A 44/39/33.5 dB(A)
HRV-D1500(B) 1,500 m³/h 1740×1375×615 mm 181.5 / 213 kg 346×326 mm 180 Pa 3.8 A 51.5/46.5/41.5 dB(A)
HRV-D2000(B) 2,000 m³/h 1811×1575×685 mm 208.5 / 245 kg 346×326 mm 200 Pa 5.7 A 53/48.5/42.5 dB(A)

Notes: three fan speeds on all models, single values measured at high speed. Sound pressure measured 1.5 m below the unit. Operating range -7 °C to +43 °C, indoor humidity below 80%. Only HRV-D1500 and D2000 require a PVC drain. Power supply 220-240 V, single-phase, 50 Hz on all sizes.

Frequently Asked Questions
Does the unit need a condensate drain?

Sizes from 200 to 1,000 m³/h need no drain at all, because the paper core transfers moisture as vapour. Only the 1,500 and 2,000 m³/h models require a PVC drain connection with slope and trap.

What ceiling depth do I need?

272 mm casing for HRV-D200, D300 and D400; 390 mm for D500, D800 and D1000; 615 to 685 mm for D1500 and D2000. Add clearance for suspension rods and filter access.

What duct sizes does the range use?

Φ144 mm on 200 and 300 m³/h, Φ198 mm on 400 m³/h, Φ244 mm on 500 to 1,000 m³/h, and rectangular 346×326 mm on 1,500 and 2,000 m³/h.

How much static pressure is available?

From 90 Pa on the smaller models to 200 Pa on HRV-D2000. Deduct filter, silencer, duct and grille resistance before confirming the design point.

Can it run in cold climates?

The operating range is -7 °C to +43 °C for both outdoor and indoor air, with indoor humidity below 80%. Below that, plan pre-heating or a frost protection strategy at design stage.

How does it interlock with a VRF system?

The PQE port synchronises start and stop with Midea VRF indoor units. One KJR-27B/E controller can manage up to 16 units, and the CCM centralised controllers bring HRV and VRF onto one panel.

Is the BMS gateway included?

GW-MOD(A) for Modbus RTU and IMMP-BAC for BACnet are available as options. Specify the protocol at order stage so the gateway ships with the units rather than as a later retrofit.

Product Gallery
Related Search Terms

ceiling heat recovery ventilator installation, hrv without drain pipe, slim hrv 272mm, erv duct connection sizes, hrv external static pressure, vrf interlock ventilation, bacnet hrv gateway, ceiling void hrv dimensions