Ceiling voids are where ventilation projects fail. The unit itself is rarely the problem; the condensate line, the casing depth and the duct transitions are. The DC Series is laid out with that in mind. Eight models span 200 to 2,000 m³/h, with casing depths of 272 mm, 390 mm and 615 to 685 mm in three steps, so a coordination drawing can place the right box in the right void without redesigning the ceiling.
Six of the eight sizes need no condensate drain at all. The heat exchange core is made of specially treated paper that transfers moisture as vapour rather than condensing it, so sizes from 200 to 1,000 m³/h have no drain pan, no slope to design and no trap to prime. Only the 1,500 and 2,000 m³/h models require a PVC drain connection. On a project with dozens of units, that removes the single most common source of ceiling rework.
Integration follows the same logic. Round spigots from Φ144 to Φ244 mm on the small and mid sizes, rectangular 346×326 mm connections on the two largest, external static pressure from 90 to 200 Pa to cover real duct runs, single-phase 220-240 V power across the range, and a PQE port that interlocks the unit with Midea VRF indoor units. Centralised controllers and Modbus or BACnet gateways hand the whole floor to the BMS contractor in one package.
| Airflow | Models | Condensate Drain |
|---|---|---|
| 200–1,000 m³/h | HRV-D200, D300, D400, D500, D800, D1000 | Not required — moisture transfers through the paper core as vapour |
| 1,500–2,000 m³/h | HRV-D1500, D2000 | PVC drain connection required, with slope and trap |
| Airflow | Models | Casing Depth | Overall Dimensions (L × W × H) |
|---|---|---|---|
| 200–400 m³/h | HRV-D200, D300, D400 | 272 mm | 1195×801, 1195×914, 1276×1204 mm |
| 500–1,000 m³/h | HRV-D500, D800, D1000 | 390 mm | 1311×1106, 1311×1286, 1311×1526 mm |
| 1,500–2,000 m³/h | HRV-D1500, D2000 | 615–685 mm | 1740×1375, 1811×1575 mm |
Allow additional space for suspension rods, filter access and duct transitions. Filter replacement is from the service panel, so the access side must stay clear.
| Airflow | Spigot | External Static Pressure |
|---|---|---|
| 200–300 m³/h | Φ144 mm | 100 / 90 Pa |
| 400 m³/h | Φ198 mm | 100 Pa |
| 500–1,000 m³/h | Φ244 mm | 90 / 140 / 160 Pa |
| 1,500–2,000 m³/h | 346×326 mm | 180 / 200 Pa |
Static pressure figures are the available head at rated airflow. Deduct the resistance of filters, flexible connections, silencers, duct runs and grilles before confirming the design point. Where the duct run is long or heavily fitted, size the unit on the next model up rather than adding a booster.
| Model | Airflow | Dimensions L × W × H | Net / Gross Weight | Spigot | External Static Pressure | Current | Sound Pressure (H/M/L) |
|---|---|---|---|---|---|---|---|
| HRV-D200(B) | 200 m³/h | 1195×801×272 mm | 53.6 / 70.6 kg | Φ144 mm | 100 Pa | 0.64 A | 33/29.5/25.5 dB(A) |
| HRV-D300(B) | 300 m³/h | 1195×914×272 mm | 59 / 77 kg | Φ144 mm | 90 Pa | 0.84 A | 36.5/33.5/30 dB(A) |
| HRV-D400(B) | 400 m³/h | 1276×1204×272 mm | 71.5 / 91.5 kg | Φ198 mm | 100 Pa | 0.97 A | 36.5/32/28 dB(A) |
| HRV-D500(B) | 500 m³/h | 1311×1106×390 mm | 74.4 / 98.6 kg | Φ244 mm | 90 Pa | 1.2 A | 36/30.5/24.5 dB(A) |
| HRV-D800(B) | 800 m³/h | 1311×1286×390 mm | 80 / 104 kg | Φ244 mm | 140 Pa | 2.4 A | 42/39/34 dB(A) |
| HRV-D1000(B) | 1,000 m³/h | 1311×1526×390 mm | 90 / 112 kg | Φ244 mm | 160 Pa | 2.9 A | 44/39/33.5 dB(A) |
| HRV-D1500(B) | 1,500 m³/h | 1740×1375×615 mm | 181.5 / 213 kg | 346×326 mm | 180 Pa | 3.8 A | 51.5/46.5/41.5 dB(A) |
| HRV-D2000(B) | 2,000 m³/h | 1811×1575×685 mm | 208.5 / 245 kg | 346×326 mm | 200 Pa | 5.7 A | 53/48.5/42.5 dB(A) |
Notes: three fan speeds on all models, single values measured at high speed. Sound pressure measured 1.5 m below the unit. Operating range -7 °C to +43 °C, indoor humidity below 80%. Only HRV-D1500 and D2000 require a PVC drain. Power supply 220-240 V, single-phase, 50 Hz on all sizes.
Sizes from 200 to 1,000 m³/h need no drain at all, because the paper core transfers moisture as vapour. Only the 1,500 and 2,000 m³/h models require a PVC drain connection with slope and trap.
272 mm casing for HRV-D200, D300 and D400; 390 mm for D500, D800 and D1000; 615 to 685 mm for D1500 and D2000. Add clearance for suspension rods and filter access.
Φ144 mm on 200 and 300 m³/h, Φ198 mm on 400 m³/h, Φ244 mm on 500 to 1,000 m³/h, and rectangular 346×326 mm on 1,500 and 2,000 m³/h.
From 90 Pa on the smaller models to 200 Pa on HRV-D2000. Deduct filter, silencer, duct and grille resistance before confirming the design point.
The operating range is -7 °C to +43 °C for both outdoor and indoor air, with indoor humidity below 80%. Below that, plan pre-heating or a frost protection strategy at design stage.
The PQE port synchronises start and stop with Midea VRF indoor units. One KJR-27B/E controller can manage up to 16 units, and the CCM centralised controllers bring HRV and VRF onto one panel.
GW-MOD(A) for Modbus RTU and IMMP-BAC for BACnet are available as options. Specify the protocol at order stage so the gateway ships with the units rather than as a later retrofit.
ceiling heat recovery ventilator installation, hrv without drain pipe, slim hrv 272mm, erv duct connection sizes, hrv external static pressure, vrf interlock ventilation, bacnet hrv gateway, ceiling void hrv dimensions
Ceiling voids are where ventilation projects fail. The unit itself is rarely the problem; the condensate line, the casing depth and the duct transitions are. The DC Series is laid out with that in mind. Eight models span 200 to 2,000 m³/h, with casing depths of 272 mm, 390 mm and 615 to 685 mm in three steps, so a coordination drawing can place the right box in the right void without redesigning the ceiling.
Six of the eight sizes need no condensate drain at all. The heat exchange core is made of specially treated paper that transfers moisture as vapour rather than condensing it, so sizes from 200 to 1,000 m³/h have no drain pan, no slope to design and no trap to prime. Only the 1,500 and 2,000 m³/h models require a PVC drain connection. On a project with dozens of units, that removes the single most common source of ceiling rework.
Integration follows the same logic. Round spigots from Φ144 to Φ244 mm on the small and mid sizes, rectangular 346×326 mm connections on the two largest, external static pressure from 90 to 200 Pa to cover real duct runs, single-phase 220-240 V power across the range, and a PQE port that interlocks the unit with Midea VRF indoor units. Centralised controllers and Modbus or BACnet gateways hand the whole floor to the BMS contractor in one package.
| Airflow | Models | Condensate Drain |
|---|---|---|
| 200–1,000 m³/h | HRV-D200, D300, D400, D500, D800, D1000 | Not required — moisture transfers through the paper core as vapour |
| 1,500–2,000 m³/h | HRV-D1500, D2000 | PVC drain connection required, with slope and trap |
| Airflow | Models | Casing Depth | Overall Dimensions (L × W × H) |
|---|---|---|---|
| 200–400 m³/h | HRV-D200, D300, D400 | 272 mm | 1195×801, 1195×914, 1276×1204 mm |
| 500–1,000 m³/h | HRV-D500, D800, D1000 | 390 mm | 1311×1106, 1311×1286, 1311×1526 mm |
| 1,500–2,000 m³/h | HRV-D1500, D2000 | 615–685 mm | 1740×1375, 1811×1575 mm |
Allow additional space for suspension rods, filter access and duct transitions. Filter replacement is from the service panel, so the access side must stay clear.
| Airflow | Spigot | External Static Pressure |
|---|---|---|
| 200–300 m³/h | Φ144 mm | 100 / 90 Pa |
| 400 m³/h | Φ198 mm | 100 Pa |
| 500–1,000 m³/h | Φ244 mm | 90 / 140 / 160 Pa |
| 1,500–2,000 m³/h | 346×326 mm | 180 / 200 Pa |
Static pressure figures are the available head at rated airflow. Deduct the resistance of filters, flexible connections, silencers, duct runs and grilles before confirming the design point. Where the duct run is long or heavily fitted, size the unit on the next model up rather than adding a booster.
| Model | Airflow | Dimensions L × W × H | Net / Gross Weight | Spigot | External Static Pressure | Current | Sound Pressure (H/M/L) |
|---|---|---|---|---|---|---|---|
| HRV-D200(B) | 200 m³/h | 1195×801×272 mm | 53.6 / 70.6 kg | Φ144 mm | 100 Pa | 0.64 A | 33/29.5/25.5 dB(A) |
| HRV-D300(B) | 300 m³/h | 1195×914×272 mm | 59 / 77 kg | Φ144 mm | 90 Pa | 0.84 A | 36.5/33.5/30 dB(A) |
| HRV-D400(B) | 400 m³/h | 1276×1204×272 mm | 71.5 / 91.5 kg | Φ198 mm | 100 Pa | 0.97 A | 36.5/32/28 dB(A) |
| HRV-D500(B) | 500 m³/h | 1311×1106×390 mm | 74.4 / 98.6 kg | Φ244 mm | 90 Pa | 1.2 A | 36/30.5/24.5 dB(A) |
| HRV-D800(B) | 800 m³/h | 1311×1286×390 mm | 80 / 104 kg | Φ244 mm | 140 Pa | 2.4 A | 42/39/34 dB(A) |
| HRV-D1000(B) | 1,000 m³/h | 1311×1526×390 mm | 90 / 112 kg | Φ244 mm | 160 Pa | 2.9 A | 44/39/33.5 dB(A) |
| HRV-D1500(B) | 1,500 m³/h | 1740×1375×615 mm | 181.5 / 213 kg | 346×326 mm | 180 Pa | 3.8 A | 51.5/46.5/41.5 dB(A) |
| HRV-D2000(B) | 2,000 m³/h | 1811×1575×685 mm | 208.5 / 245 kg | 346×326 mm | 200 Pa | 5.7 A | 53/48.5/42.5 dB(A) |
Notes: three fan speeds on all models, single values measured at high speed. Sound pressure measured 1.5 m below the unit. Operating range -7 °C to +43 °C, indoor humidity below 80%. Only HRV-D1500 and D2000 require a PVC drain. Power supply 220-240 V, single-phase, 50 Hz on all sizes.
Sizes from 200 to 1,000 m³/h need no drain at all, because the paper core transfers moisture as vapour. Only the 1,500 and 2,000 m³/h models require a PVC drain connection with slope and trap.
272 mm casing for HRV-D200, D300 and D400; 390 mm for D500, D800 and D1000; 615 to 685 mm for D1500 and D2000. Add clearance for suspension rods and filter access.
Φ144 mm on 200 and 300 m³/h, Φ198 mm on 400 m³/h, Φ244 mm on 500 to 1,000 m³/h, and rectangular 346×326 mm on 1,500 and 2,000 m³/h.
From 90 Pa on the smaller models to 200 Pa on HRV-D2000. Deduct filter, silencer, duct and grille resistance before confirming the design point.
The operating range is -7 °C to +43 °C for both outdoor and indoor air, with indoor humidity below 80%. Below that, plan pre-heating or a frost protection strategy at design stage.
The PQE port synchronises start and stop with Midea VRF indoor units. One KJR-27B/E controller can manage up to 16 units, and the CCM centralised controllers bring HRV and VRF onto one panel.
GW-MOD(A) for Modbus RTU and IMMP-BAC for BACnet are available as options. Specify the protocol at order stage so the gateway ships with the units rather than as a later retrofit.
ceiling heat recovery ventilator installation, hrv without drain pipe, slim hrv 272mm, erv duct connection sizes, hrv external static pressure, vrf interlock ventilation, bacnet hrv gateway, ceiling void hrv dimensions