Heat Recovery Ventilator 82.8% Efficiency 70W Minimum Input Energy Efficient Ventilation for Offices Schools and Hotels

Heat Recovery Ventilator 82.8% Efficiency 70W Minimum Input Energy Efficient Ventilation for Offices Schools and Hotels

Detail Information
Place of Origin
China
Brand Name
OEM;MIDEA
Certification
CB,ISO
Product Name:
Midea DC Series HRV
Airflow:
200 M³/h-2000 M³/h
Dimensions L X W X H:
1,195 X 801 X 272 Mm-1,811 X 1,575 X 685 Mm
Net / Gross Weight:
53.6 / 70.6 Kg-208.5 / 245 Kg
Spigot:
144 Mm-346 X 326 Mm
External Static Pressure:
100 Pa-200 Pa
Condensate Drain:
Not Required/PVC Required
Highlight:

Heat Recovery Ventilator 82.8% Efficiency

,

70W Energy Efficient Ventilation

,

Ventilation for Offices Schools Hotels

Product Description
Product Overview: DC Series Heat Recovery Ventilator

Fresh air carries a load that no one budgets for. Outdoor air entering a building must be heated in winter and cooled and dehumidified in summer, and that load lands on the cooling and heating plant every hour the building is occupied. A heat recovery ventilator reduces it at source. Supply and exhaust air pass through a heat exchange core made of specially treated paper, transferring heat and moisture between the two streams without mixing them, so ventilation rates stay where the standard requires them while the plant load drops.

The DC Series is built around efficiency. Temperature efficiency peaks at 82.8% and enthalpy efficiency at 76.0% on the 1,000 m³/h size, with the full range spanning 75.5–87.4% and 69.4–80.6% across three fan speeds. Both the supply and exhaust fans are DC, holding input power as low as 70 W on the smallest size and limiting the parasitic penalty of ventilation itself. Eight ceiling-mounted sizes from 200 to 2,000 m³/h let one platform serve a whole ventilation schedule without mixing product families.

Compliance is part of the specification, not an afterthought. Every size meets ErP 2009/125/EC, (EU) 327/2011 and (EU) 1253/2014, and carries CE marking alongside ISO 9001, 14001 and 45001. An optional CO2 sensor converts the unit into demand-controlled ventilation, and the bypass damper provides free cooling whenever outdoor air is cooler than the room. The result is a ventilator that can be modelled accurately at tender stage and audited after handover.

Key Selling Points
  • Up to 82.8% Temperature Efficiency — Specially treated paper core transfers heat and moisture between air streams without mixing; peak 76.0% enthalpy efficiency.
  • Lowest Input Power 70 W — Full DC motors on both supply and exhaust sides; the 200 m³/h size draws 70/45/25 W at high, medium and low speed.
  • ErP 2009/125/EC Compliant — Meets the EU Ecodesign framework for energy-related products across all eight sizes.
  • (EU) 327/2011 Compliant — Fan efficiency declared at the actual operating point, as the regulation requires, not at a best point on the curve.
  • (EU) 1253/2014 Compliant — Ventilation unit energy consumption limits and product information requirements met.
  • Efficiency Rises at Low Speed — 82.8% at high speed, 84.0% at medium and 87.4% at low on the 1,000 m³/h size; annual efficiency beats the headline figure when the unit modulates.
  • CO2 Demand Control — Optional sensor steps fan speed at four thresholds: off below 450 ppm, low at 550, medium at 800, high at 1,000 ppm.
  • Bypass Free Cooling — Damper routes fresh air around the core when outdoor temperature is lower, removing compressor load in shoulder seasons.
How to Read the Efficiency Figures
Low speed is more efficient than high speed

On HRV-D1000, temperature efficiency is 82.8% at high speed, 84.0% at medium and 87.4% at low, and the same pattern holds across the range. With a fixed core, lower airflow means longer residence time and a larger share of heat transferred. A project that runs mostly at low speed will perform better than the headline figure suggests, not worse.

Temperature efficiency and enthalpy efficiency differ by the latent load

On the same model the gap is 6.8 points at high speed. In humid climates, enthalpy efficiency is the figure that belongs in the energy model, because dehumidification is where the summer load sits.

All figures are measured with the standard G4 filter fitted

Selecting F7 on the supply side and M5 on the exhaust side raises filtration grade and adds static pressure, which the DC motors absorb. Efficiency data for both configurations is published in the engineering manual, so consultants can model either without applying a rule-of-thumb derating.

Energy Reference Calculation

Basis: 1,000 m³/h at high speed, air density 1.2 kg/m³, specific heat 1.005 kJ/kg·K, sensible load only. Latent load in summer is additional and is carried by the enthalpy exchange.

Condition Load without recovery Load at 82.8% recovery Load saved
Winter, −5 °C outdoor, 20 °C indoor 8.38 kW 1.44 kW 6.93 kW
Summer, 35 °C outdoor, 26 °C indoor 3.01 kW 0.52 kW 2.50 kW

At 2,000 operating hours a year, the winter case alone returns approximately 13,870 kWh. The unit draws 380 W at high speed. Figures are indicative and should be recalculated against project design temperatures and local energy prices.

Compliance and Standards
  • CE — EU safety and electromagnetic compatibility.
  • ErP 2009/125/EC — Ecodesign framework for energy-related products.
  • (EU) 327/2011 — Fan efficiency, declared at the actual operating point.
  • (EU) 1253/2014 — Ventilation units, energy consumption limits and information requirements.
  • ISO 9001 / 14001 / 45001 — Quality, environmental and occupational health and safety management.
Energy-Saving Configurations
  • CO2 demand control — Optional sensor with four thresholds: stop below 450 ppm, low at 550 ppm, medium at 800 ppm, high at 1,000 ppm. Ventilation follows occupancy instead of running at constant volume.
  • Bypass free cooling — When outdoor temperature is below indoor temperature, incoming air bypasses the core entirely, providing cooling with no compressor runtime.
  • Weekly scheduling — The WDC-120G/WK(A) controller adds weekly timers and delayed shutdown, preventing operation in unoccupied buildings.
  • VRF interlock — The PQE port synchronises start and stop with Midea VRF indoor units, removing wasted running hours on unoccupied floors.
Technical Data
Model Airflow Input power (H/M/L) Temp. efficiency (H/M/L) Enthalpy efficiency (H/M/L) Current External static pressure Sound pressure (H/M/L)
HRV-D200(B) 200 m³/h 70/45/25 W 79.5/81.1/83.5% 75.0/77.5/79.6% 0.64 A 100 Pa 33/29.5/25.5 dB(A)
HRV-D300(B) 300 m³/h 100/55/35 W 75.5/78.8/82.5% 72.1/75.0/79.3% 0.84 A 90 Pa 36.5/33.5/30 dB(A)
HRV-D400(B) 400 m³/h 110/70/40 W 77.7/79.0/81.3% 73.5/75.3/78.0% 0.97 A 100 Pa 36.5/32/28 dB(A)
HRV-D500(B) 500 m³/h 150/95/50 W 80.6/82.2/85.5% 74.0/76.6/80.5% 1.2 A 90 Pa 36/30.5/24.5 dB(A)
HRV-D800(B) 800 m³/h 320/170/80 W 78.7/82.1/86.8% 72.3/75.4/79.0% 2.4 A 140 Pa 42/39/34 dB(A)
HRV-D1000(B) 1,000 m³/h 380/210/100 W 82.8/84.0/87.4% 76.0/76.0/80.1% 2.9 A 160 Pa 44/39/33.5 dB(A)
HRV-D1500(B) 1,500 m³/h 680/320/200 W 75.5/78.6/80.2% 69.4/71.2/74.8% 3.8 A 180 Pa 51.5/46.5/41.5 dB(A)
HRV-D2000(B) 2,000 m³/h 950/500/230 W 77.2/79.5/83.4% 74.7/77.0/80.6% 5.7 A 200 Pa 53/48.5/42.5 dB(A)

Notes: all models have three fan speeds; single values are measured at high speed. Sound pressure measured 1.5 m below the unit. Efficiency figures are with the standard G4 filter; F7 plus M5 data is published in the engineering manual. Operating range −7 °C to +43 °C, indoor humidity below 80%.

Frequently Asked Questions
What does 82.8% temperature efficiency mean in practice?

It means 82.8% of the temperature difference between exhaust and fresh air is transferred to the incoming stream. For a 1,000 m³/h system at 20 °C indoors and −5 °C outdoors, the heating load on the fresh air drops from 8.38 kW to 1.44 kW.

Why is efficiency higher at low speed?

With a fixed core, lower airflow gives the air more time in the exchanger, so a larger share of heat transfers. On HRV-D1000 the figure rises from 82.8% at high speed to 87.4% at low.

Which figure should go into my energy model, temperature or enthalpy efficiency?

Temperature efficiency for sensible calculations, enthalpy efficiency where latent load matters. In humid climates, use enthalpy efficiency, because dehumidification dominates the summer load.

Does the unit comply with European energy regulations?

All eight sizes meet ErP 2009/125/EC, (EU) 327/2011 and (EU) 1253/2014, and carry CE marking with ISO 9001, 14001 and 45001.

Is the efficiency data measured with standard or upgraded filters?

With the standard G4 filter on both air streams. Data for the F7 supply and M5 exhaust configuration is published in the engineering manual, so no manual derating is needed.

How much does demand control save compared with constant volume?

Savings depend on occupancy profile. A meeting room used eight hours a day does not need design airflow for the other sixteen, and the four CO2 thresholds let the unit match actual use rather than design peak.

What is the power supply?

Single-phase 220–240 V, 50 Hz, 3-core 2.5 mm² cable across the range. For export projects, OEM/ODM voltage customisation from 180–440 V at 50/60 Hz is available from the factory.

Related Search Terms
  • energy recovery ventilation efficiency
  • heat recovery ventilator ErP
  • HRV temperature efficiency
  • DC ERV power consumption
  • CO2 demand control ventilation
  • ERV energy saving calculation
  • EU 327/2011 fan efficiency
  • heat recovery ventilator power consumption
DC Series heat recovery ventilator unit with specially treated paper heat exchange core for energy-efficient ventilation
Ceiling-mounted DC heat recovery ventilator showing supply and exhaust fan configuration and bypass damper
Products
PRODUCTS DETAILS
Heat Recovery Ventilator 82.8% Efficiency 70W Minimum Input Energy Efficient Ventilation for Offices Schools and Hotels
Detail Information
Place of Origin
China
Brand Name
OEM;MIDEA
Certification
CB,ISO
Product Name:
Midea DC Series HRV
Airflow:
200 M³/h-2000 M³/h
Dimensions L X W X H:
1,195 X 801 X 272 Mm-1,811 X 1,575 X 685 Mm
Net / Gross Weight:
53.6 / 70.6 Kg-208.5 / 245 Kg
Spigot:
144 Mm-346 X 326 Mm
External Static Pressure:
100 Pa-200 Pa
Condensate Drain:
Not Required/PVC Required
Highlight

Heat Recovery Ventilator 82.8% Efficiency

,

70W Energy Efficient Ventilation

,

Ventilation for Offices Schools Hotels

Product Description
Product Overview: DC Series Heat Recovery Ventilator

Fresh air carries a load that no one budgets for. Outdoor air entering a building must be heated in winter and cooled and dehumidified in summer, and that load lands on the cooling and heating plant every hour the building is occupied. A heat recovery ventilator reduces it at source. Supply and exhaust air pass through a heat exchange core made of specially treated paper, transferring heat and moisture between the two streams without mixing them, so ventilation rates stay where the standard requires them while the plant load drops.

The DC Series is built around efficiency. Temperature efficiency peaks at 82.8% and enthalpy efficiency at 76.0% on the 1,000 m³/h size, with the full range spanning 75.5–87.4% and 69.4–80.6% across three fan speeds. Both the supply and exhaust fans are DC, holding input power as low as 70 W on the smallest size and limiting the parasitic penalty of ventilation itself. Eight ceiling-mounted sizes from 200 to 2,000 m³/h let one platform serve a whole ventilation schedule without mixing product families.

Compliance is part of the specification, not an afterthought. Every size meets ErP 2009/125/EC, (EU) 327/2011 and (EU) 1253/2014, and carries CE marking alongside ISO 9001, 14001 and 45001. An optional CO2 sensor converts the unit into demand-controlled ventilation, and the bypass damper provides free cooling whenever outdoor air is cooler than the room. The result is a ventilator that can be modelled accurately at tender stage and audited after handover.

Key Selling Points
  • Up to 82.8% Temperature Efficiency — Specially treated paper core transfers heat and moisture between air streams without mixing; peak 76.0% enthalpy efficiency.
  • Lowest Input Power 70 W — Full DC motors on both supply and exhaust sides; the 200 m³/h size draws 70/45/25 W at high, medium and low speed.
  • ErP 2009/125/EC Compliant — Meets the EU Ecodesign framework for energy-related products across all eight sizes.
  • (EU) 327/2011 Compliant — Fan efficiency declared at the actual operating point, as the regulation requires, not at a best point on the curve.
  • (EU) 1253/2014 Compliant — Ventilation unit energy consumption limits and product information requirements met.
  • Efficiency Rises at Low Speed — 82.8% at high speed, 84.0% at medium and 87.4% at low on the 1,000 m³/h size; annual efficiency beats the headline figure when the unit modulates.
  • CO2 Demand Control — Optional sensor steps fan speed at four thresholds: off below 450 ppm, low at 550, medium at 800, high at 1,000 ppm.
  • Bypass Free Cooling — Damper routes fresh air around the core when outdoor temperature is lower, removing compressor load in shoulder seasons.
How to Read the Efficiency Figures
Low speed is more efficient than high speed

On HRV-D1000, temperature efficiency is 82.8% at high speed, 84.0% at medium and 87.4% at low, and the same pattern holds across the range. With a fixed core, lower airflow means longer residence time and a larger share of heat transferred. A project that runs mostly at low speed will perform better than the headline figure suggests, not worse.

Temperature efficiency and enthalpy efficiency differ by the latent load

On the same model the gap is 6.8 points at high speed. In humid climates, enthalpy efficiency is the figure that belongs in the energy model, because dehumidification is where the summer load sits.

All figures are measured with the standard G4 filter fitted

Selecting F7 on the supply side and M5 on the exhaust side raises filtration grade and adds static pressure, which the DC motors absorb. Efficiency data for both configurations is published in the engineering manual, so consultants can model either without applying a rule-of-thumb derating.

Energy Reference Calculation

Basis: 1,000 m³/h at high speed, air density 1.2 kg/m³, specific heat 1.005 kJ/kg·K, sensible load only. Latent load in summer is additional and is carried by the enthalpy exchange.

Condition Load without recovery Load at 82.8% recovery Load saved
Winter, −5 °C outdoor, 20 °C indoor 8.38 kW 1.44 kW 6.93 kW
Summer, 35 °C outdoor, 26 °C indoor 3.01 kW 0.52 kW 2.50 kW

At 2,000 operating hours a year, the winter case alone returns approximately 13,870 kWh. The unit draws 380 W at high speed. Figures are indicative and should be recalculated against project design temperatures and local energy prices.

Compliance and Standards
  • CE — EU safety and electromagnetic compatibility.
  • ErP 2009/125/EC — Ecodesign framework for energy-related products.
  • (EU) 327/2011 — Fan efficiency, declared at the actual operating point.
  • (EU) 1253/2014 — Ventilation units, energy consumption limits and information requirements.
  • ISO 9001 / 14001 / 45001 — Quality, environmental and occupational health and safety management.
Energy-Saving Configurations
  • CO2 demand control — Optional sensor with four thresholds: stop below 450 ppm, low at 550 ppm, medium at 800 ppm, high at 1,000 ppm. Ventilation follows occupancy instead of running at constant volume.
  • Bypass free cooling — When outdoor temperature is below indoor temperature, incoming air bypasses the core entirely, providing cooling with no compressor runtime.
  • Weekly scheduling — The WDC-120G/WK(A) controller adds weekly timers and delayed shutdown, preventing operation in unoccupied buildings.
  • VRF interlock — The PQE port synchronises start and stop with Midea VRF indoor units, removing wasted running hours on unoccupied floors.
Technical Data
Model Airflow Input power (H/M/L) Temp. efficiency (H/M/L) Enthalpy efficiency (H/M/L) Current External static pressure Sound pressure (H/M/L)
HRV-D200(B) 200 m³/h 70/45/25 W 79.5/81.1/83.5% 75.0/77.5/79.6% 0.64 A 100 Pa 33/29.5/25.5 dB(A)
HRV-D300(B) 300 m³/h 100/55/35 W 75.5/78.8/82.5% 72.1/75.0/79.3% 0.84 A 90 Pa 36.5/33.5/30 dB(A)
HRV-D400(B) 400 m³/h 110/70/40 W 77.7/79.0/81.3% 73.5/75.3/78.0% 0.97 A 100 Pa 36.5/32/28 dB(A)
HRV-D500(B) 500 m³/h 150/95/50 W 80.6/82.2/85.5% 74.0/76.6/80.5% 1.2 A 90 Pa 36/30.5/24.5 dB(A)
HRV-D800(B) 800 m³/h 320/170/80 W 78.7/82.1/86.8% 72.3/75.4/79.0% 2.4 A 140 Pa 42/39/34 dB(A)
HRV-D1000(B) 1,000 m³/h 380/210/100 W 82.8/84.0/87.4% 76.0/76.0/80.1% 2.9 A 160 Pa 44/39/33.5 dB(A)
HRV-D1500(B) 1,500 m³/h 680/320/200 W 75.5/78.6/80.2% 69.4/71.2/74.8% 3.8 A 180 Pa 51.5/46.5/41.5 dB(A)
HRV-D2000(B) 2,000 m³/h 950/500/230 W 77.2/79.5/83.4% 74.7/77.0/80.6% 5.7 A 200 Pa 53/48.5/42.5 dB(A)

Notes: all models have three fan speeds; single values are measured at high speed. Sound pressure measured 1.5 m below the unit. Efficiency figures are with the standard G4 filter; F7 plus M5 data is published in the engineering manual. Operating range −7 °C to +43 °C, indoor humidity below 80%.

Frequently Asked Questions
What does 82.8% temperature efficiency mean in practice?

It means 82.8% of the temperature difference between exhaust and fresh air is transferred to the incoming stream. For a 1,000 m³/h system at 20 °C indoors and −5 °C outdoors, the heating load on the fresh air drops from 8.38 kW to 1.44 kW.

Why is efficiency higher at low speed?

With a fixed core, lower airflow gives the air more time in the exchanger, so a larger share of heat transfers. On HRV-D1000 the figure rises from 82.8% at high speed to 87.4% at low.

Which figure should go into my energy model, temperature or enthalpy efficiency?

Temperature efficiency for sensible calculations, enthalpy efficiency where latent load matters. In humid climates, use enthalpy efficiency, because dehumidification dominates the summer load.

Does the unit comply with European energy regulations?

All eight sizes meet ErP 2009/125/EC, (EU) 327/2011 and (EU) 1253/2014, and carry CE marking with ISO 9001, 14001 and 45001.

Is the efficiency data measured with standard or upgraded filters?

With the standard G4 filter on both air streams. Data for the F7 supply and M5 exhaust configuration is published in the engineering manual, so no manual derating is needed.

How much does demand control save compared with constant volume?

Savings depend on occupancy profile. A meeting room used eight hours a day does not need design airflow for the other sixteen, and the four CO2 thresholds let the unit match actual use rather than design peak.

What is the power supply?

Single-phase 220–240 V, 50 Hz, 3-core 2.5 mm² cable across the range. For export projects, OEM/ODM voltage customisation from 180–440 V at 50/60 Hz is available from the factory.

Related Search Terms
  • energy recovery ventilation efficiency
  • heat recovery ventilator ErP
  • HRV temperature efficiency
  • DC ERV power consumption
  • CO2 demand control ventilation
  • ERV energy saving calculation
  • EU 327/2011 fan efficiency
  • heat recovery ventilator power consumption
DC Series heat recovery ventilator unit with specially treated paper heat exchange core for energy-efficient ventilation
Ceiling-mounted DC heat recovery ventilator showing supply and exhaust fan configuration and bypass damper