Fresh air carries a load that no one budgets for. Outdoor air entering a building must be heated in winter and cooled and dehumidified in summer, and that load lands on the cooling and heating plant every hour the building is occupied. A heat recovery ventilator reduces it at source. Supply and exhaust air pass through a heat exchange core made of specially treated paper, transferring heat and moisture between the two streams without mixing them, so ventilation rates stay where the standard requires them while the plant load drops.
The DC Series is built around efficiency. Temperature efficiency peaks at 82.8% and enthalpy efficiency at 76.0% on the 1,000 m³/h size, with the full range spanning 75.5–87.4% and 69.4–80.6% across three fan speeds. Both the supply and exhaust fans are DC, holding input power as low as 70 W on the smallest size and limiting the parasitic penalty of ventilation itself. Eight ceiling-mounted sizes from 200 to 2,000 m³/h let one platform serve a whole ventilation schedule without mixing product families.
Compliance is part of the specification, not an afterthought. Every size meets ErP 2009/125/EC, (EU) 327/2011 and (EU) 1253/2014, and carries CE marking alongside ISO 9001, 14001 and 45001. An optional CO2 sensor converts the unit into demand-controlled ventilation, and the bypass damper provides free cooling whenever outdoor air is cooler than the room. The result is a ventilator that can be modelled accurately at tender stage and audited after handover.
On HRV-D1000, temperature efficiency is 82.8% at high speed, 84.0% at medium and 87.4% at low, and the same pattern holds across the range. With a fixed core, lower airflow means longer residence time and a larger share of heat transferred. A project that runs mostly at low speed will perform better than the headline figure suggests, not worse.
On the same model the gap is 6.8 points at high speed. In humid climates, enthalpy efficiency is the figure that belongs in the energy model, because dehumidification is where the summer load sits.
Selecting F7 on the supply side and M5 on the exhaust side raises filtration grade and adds static pressure, which the DC motors absorb. Efficiency data for both configurations is published in the engineering manual, so consultants can model either without applying a rule-of-thumb derating.
Basis: 1,000 m³/h at high speed, air density 1.2 kg/m³, specific heat 1.005 kJ/kg·K, sensible load only. Latent load in summer is additional and is carried by the enthalpy exchange.
| Condition | Load without recovery | Load at 82.8% recovery | Load saved |
|---|---|---|---|
| Winter, −5 °C outdoor, 20 °C indoor | 8.38 kW | 1.44 kW | 6.93 kW |
| Summer, 35 °C outdoor, 26 °C indoor | 3.01 kW | 0.52 kW | 2.50 kW |
At 2,000 operating hours a year, the winter case alone returns approximately 13,870 kWh. The unit draws 380 W at high speed. Figures are indicative and should be recalculated against project design temperatures and local energy prices.
| Model | Airflow | Input power (H/M/L) | Temp. efficiency (H/M/L) | Enthalpy efficiency (H/M/L) | Current | External static pressure | Sound pressure (H/M/L) |
|---|---|---|---|---|---|---|---|
| HRV-D200(B) | 200 m³/h | 70/45/25 W | 79.5/81.1/83.5% | 75.0/77.5/79.6% | 0.64 A | 100 Pa | 33/29.5/25.5 dB(A) |
| HRV-D300(B) | 300 m³/h | 100/55/35 W | 75.5/78.8/82.5% | 72.1/75.0/79.3% | 0.84 A | 90 Pa | 36.5/33.5/30 dB(A) |
| HRV-D400(B) | 400 m³/h | 110/70/40 W | 77.7/79.0/81.3% | 73.5/75.3/78.0% | 0.97 A | 100 Pa | 36.5/32/28 dB(A) |
| HRV-D500(B) | 500 m³/h | 150/95/50 W | 80.6/82.2/85.5% | 74.0/76.6/80.5% | 1.2 A | 90 Pa | 36/30.5/24.5 dB(A) |
| HRV-D800(B) | 800 m³/h | 320/170/80 W | 78.7/82.1/86.8% | 72.3/75.4/79.0% | 2.4 A | 140 Pa | 42/39/34 dB(A) |
| HRV-D1000(B) | 1,000 m³/h | 380/210/100 W | 82.8/84.0/87.4% | 76.0/76.0/80.1% | 2.9 A | 160 Pa | 44/39/33.5 dB(A) |
| HRV-D1500(B) | 1,500 m³/h | 680/320/200 W | 75.5/78.6/80.2% | 69.4/71.2/74.8% | 3.8 A | 180 Pa | 51.5/46.5/41.5 dB(A) |
| HRV-D2000(B) | 2,000 m³/h | 950/500/230 W | 77.2/79.5/83.4% | 74.7/77.0/80.6% | 5.7 A | 200 Pa | 53/48.5/42.5 dB(A) |
Notes: all models have three fan speeds; single values are measured at high speed. Sound pressure measured 1.5 m below the unit. Efficiency figures are with the standard G4 filter; F7 plus M5 data is published in the engineering manual. Operating range −7 °C to +43 °C, indoor humidity below 80%.
It means 82.8% of the temperature difference between exhaust and fresh air is transferred to the incoming stream. For a 1,000 m³/h system at 20 °C indoors and −5 °C outdoors, the heating load on the fresh air drops from 8.38 kW to 1.44 kW.
With a fixed core, lower airflow gives the air more time in the exchanger, so a larger share of heat transfers. On HRV-D1000 the figure rises from 82.8% at high speed to 87.4% at low.
Temperature efficiency for sensible calculations, enthalpy efficiency where latent load matters. In humid climates, use enthalpy efficiency, because dehumidification dominates the summer load.
All eight sizes meet ErP 2009/125/EC, (EU) 327/2011 and (EU) 1253/2014, and carry CE marking with ISO 9001, 14001 and 45001.
With the standard G4 filter on both air streams. Data for the F7 supply and M5 exhaust configuration is published in the engineering manual, so no manual derating is needed.
Savings depend on occupancy profile. A meeting room used eight hours a day does not need design airflow for the other sixteen, and the four CO2 thresholds let the unit match actual use rather than design peak.
Single-phase 220–240 V, 50 Hz, 3-core 2.5 mm² cable across the range. For export projects, OEM/ODM voltage customisation from 180–440 V at 50/60 Hz is available from the factory.
Fresh air carries a load that no one budgets for. Outdoor air entering a building must be heated in winter and cooled and dehumidified in summer, and that load lands on the cooling and heating plant every hour the building is occupied. A heat recovery ventilator reduces it at source. Supply and exhaust air pass through a heat exchange core made of specially treated paper, transferring heat and moisture between the two streams without mixing them, so ventilation rates stay where the standard requires them while the plant load drops.
The DC Series is built around efficiency. Temperature efficiency peaks at 82.8% and enthalpy efficiency at 76.0% on the 1,000 m³/h size, with the full range spanning 75.5–87.4% and 69.4–80.6% across three fan speeds. Both the supply and exhaust fans are DC, holding input power as low as 70 W on the smallest size and limiting the parasitic penalty of ventilation itself. Eight ceiling-mounted sizes from 200 to 2,000 m³/h let one platform serve a whole ventilation schedule without mixing product families.
Compliance is part of the specification, not an afterthought. Every size meets ErP 2009/125/EC, (EU) 327/2011 and (EU) 1253/2014, and carries CE marking alongside ISO 9001, 14001 and 45001. An optional CO2 sensor converts the unit into demand-controlled ventilation, and the bypass damper provides free cooling whenever outdoor air is cooler than the room. The result is a ventilator that can be modelled accurately at tender stage and audited after handover.
On HRV-D1000, temperature efficiency is 82.8% at high speed, 84.0% at medium and 87.4% at low, and the same pattern holds across the range. With a fixed core, lower airflow means longer residence time and a larger share of heat transferred. A project that runs mostly at low speed will perform better than the headline figure suggests, not worse.
On the same model the gap is 6.8 points at high speed. In humid climates, enthalpy efficiency is the figure that belongs in the energy model, because dehumidification is where the summer load sits.
Selecting F7 on the supply side and M5 on the exhaust side raises filtration grade and adds static pressure, which the DC motors absorb. Efficiency data for both configurations is published in the engineering manual, so consultants can model either without applying a rule-of-thumb derating.
Basis: 1,000 m³/h at high speed, air density 1.2 kg/m³, specific heat 1.005 kJ/kg·K, sensible load only. Latent load in summer is additional and is carried by the enthalpy exchange.
| Condition | Load without recovery | Load at 82.8% recovery | Load saved |
|---|---|---|---|
| Winter, −5 °C outdoor, 20 °C indoor | 8.38 kW | 1.44 kW | 6.93 kW |
| Summer, 35 °C outdoor, 26 °C indoor | 3.01 kW | 0.52 kW | 2.50 kW |
At 2,000 operating hours a year, the winter case alone returns approximately 13,870 kWh. The unit draws 380 W at high speed. Figures are indicative and should be recalculated against project design temperatures and local energy prices.
| Model | Airflow | Input power (H/M/L) | Temp. efficiency (H/M/L) | Enthalpy efficiency (H/M/L) | Current | External static pressure | Sound pressure (H/M/L) |
|---|---|---|---|---|---|---|---|
| HRV-D200(B) | 200 m³/h | 70/45/25 W | 79.5/81.1/83.5% | 75.0/77.5/79.6% | 0.64 A | 100 Pa | 33/29.5/25.5 dB(A) |
| HRV-D300(B) | 300 m³/h | 100/55/35 W | 75.5/78.8/82.5% | 72.1/75.0/79.3% | 0.84 A | 90 Pa | 36.5/33.5/30 dB(A) |
| HRV-D400(B) | 400 m³/h | 110/70/40 W | 77.7/79.0/81.3% | 73.5/75.3/78.0% | 0.97 A | 100 Pa | 36.5/32/28 dB(A) |
| HRV-D500(B) | 500 m³/h | 150/95/50 W | 80.6/82.2/85.5% | 74.0/76.6/80.5% | 1.2 A | 90 Pa | 36/30.5/24.5 dB(A) |
| HRV-D800(B) | 800 m³/h | 320/170/80 W | 78.7/82.1/86.8% | 72.3/75.4/79.0% | 2.4 A | 140 Pa | 42/39/34 dB(A) |
| HRV-D1000(B) | 1,000 m³/h | 380/210/100 W | 82.8/84.0/87.4% | 76.0/76.0/80.1% | 2.9 A | 160 Pa | 44/39/33.5 dB(A) |
| HRV-D1500(B) | 1,500 m³/h | 680/320/200 W | 75.5/78.6/80.2% | 69.4/71.2/74.8% | 3.8 A | 180 Pa | 51.5/46.5/41.5 dB(A) |
| HRV-D2000(B) | 2,000 m³/h | 950/500/230 W | 77.2/79.5/83.4% | 74.7/77.0/80.6% | 5.7 A | 200 Pa | 53/48.5/42.5 dB(A) |
Notes: all models have three fan speeds; single values are measured at high speed. Sound pressure measured 1.5 m below the unit. Efficiency figures are with the standard G4 filter; F7 plus M5 data is published in the engineering manual. Operating range −7 °C to +43 °C, indoor humidity below 80%.
It means 82.8% of the temperature difference between exhaust and fresh air is transferred to the incoming stream. For a 1,000 m³/h system at 20 °C indoors and −5 °C outdoors, the heating load on the fresh air drops from 8.38 kW to 1.44 kW.
With a fixed core, lower airflow gives the air more time in the exchanger, so a larger share of heat transfers. On HRV-D1000 the figure rises from 82.8% at high speed to 87.4% at low.
Temperature efficiency for sensible calculations, enthalpy efficiency where latent load matters. In humid climates, use enthalpy efficiency, because dehumidification dominates the summer load.
All eight sizes meet ErP 2009/125/EC, (EU) 327/2011 and (EU) 1253/2014, and carry CE marking with ISO 9001, 14001 and 45001.
With the standard G4 filter on both air streams. Data for the F7 supply and M5 exhaust configuration is published in the engineering manual, so no manual derating is needed.
Savings depend on occupancy profile. A meeting room used eight hours a day does not need design airflow for the other sixteen, and the four CO2 thresholds let the unit match actual use rather than design peak.
Single-phase 220–240 V, 50 Hz, 3-core 2.5 mm² cable across the range. For export projects, OEM/ODM voltage customisation from 180–440 V at 50/60 Hz is available from the factory.