Full DC Heat Recovery Ventilator max temperature efficiency up to 82 minimum power 70W Compliant with ErP and EU 327 2011 airflow range 200 2000

Full DC Heat Recovery Ventilator max temperature efficiency up to 82 minimum power 70W Compliant with ErP and EU 327 2011 airflow range 200 2000

Detail Information
Place of Origin
China
Brand Name
OEM;MIDEA
Certification
CB,ISO
Product Name:
Midea DC Series HRV
Airflow:
200 M³/h-2000 M³/h
Dimensions L X W X H:
1,195 X 801 X 272 Mm-1,811 X 1,575 X 685 Mm
Net / Gross Weight:
53.6 / 70.6 Kg-208.5 / 245 Kg
Spigot:
144 Mm-346 X 326 Mm
External Static Pressure:
100 Pa-200 Pa
Condensate Drain:
Not Required/PVC Required
Highlight:

DC heat recovery ventilator

,

82% temperature efficiency ventilator

,

ErP compliant 70W ventilator

Product Description
Full DC Heat Recovery Ventilator — 200 to 2,000 m³/h

Maximum temperature efficiency up to 82.8%, minimum input power 70 W, compliant with ErP 2009/125/EC and (EU) 327/2011.

Airflow range: 200–2,000 m³/h Temp. efficiency up to 82.8% Min. input power: 70 W Full DC supply & exhaust fans CE · ErP · ISO 9001/14001/45001
Fresh Air Is a Line Item Nobody Budgets For

Every building has to bring in outdoor air. The moment it does, the air conditioning system inherits a load it never asked for: in winter that air has to be heated, in summer it has to be cooled and dehumidified, and the bill arrives every hour the building is occupied.

For a 1,000 m³/h system running between 20 °C indoors and −5 °C outdoors, that load is 8.38 kW of heating before a single person walks into the room. Nothing is wrong with the equipment. The load is simply the cost of ventilation.

A heat recovery ventilator takes most of that cost back. Two air streams, supply and exhaust, pass through a treated paper core without mixing. Heat and moisture move from the warmer stream to the colder one. The ventilation rate stays exactly where the standard requires it, and the load the cooling or heating plant has to cover drops sharply.

This is the part that matters commercially: recovery efficiency is not a comfort feature. It is a reduction in connected load, in plant capacity and in the operating budget — and it is measurable before the equipment is ordered.

What 82.8 Percent Actually Buys You

Take the same 1,000 m³/h system, HRV-D1000 at high speed, and run the numbers on both sides of the year.

Condition Load without recovery Load with 82.8% recovery Saved
Winter, −5 °C outdoor, 20 °C indoor 8.38 kW 1.44 kW 6.93 kW
Summer, 35 °C outdoor, 26 °C indoor 3.01 kW 0.52 kW 2.50 kW

Basis: air density 1.2 kg/m³, specific heat 1.005 kJ/kg·K, sensible only. Latent load in summer is additional and is carried by the enthalpy exchange.

At 2,000 operating hours a year, the winter case alone returns roughly 13,870 kWh. At an industrial electricity price of EUR 0.15 per kWh, that is about EUR 2,080 a year from one ventilator. The unit draws 380 W at high speed. It is not a close comparison.

Three things drive that number, and they are worth checking separately when you compare products.

  • The core. Temperature efficiency peaks at 82.8 percent on the 1,000 m³/h model, with enthalpy efficiency at 76.0 percent. The core is a chemically treated paper exchanger, which is why moisture moves as vapour rather than condensing into a drain pan.
  • The motors. Both the supply and exhaust fans are DC. Minimum input across the range is 70 W on the 200 m³/h model, and every model meets ErP 2009/125/EC and (EU) 327/2011. A DC fan also holds efficiency better at part load, which matters because most of the year the unit is not running at high speed.
  • The control. Efficiency at full speed is a laboratory number. Efficiency across a year is a control question, covered below.
Reading the Efficiency Figures Correctly

Three notes that most datasheets leave out.

Low speed is more efficient than high speed

On HRV-D1000, temperature efficiency is 82.8 percent at high speed, 84.0 at medium and 87.4 at low. The same pattern holds across the range. This is normal for a fixed core: at lower airflow, the air spends longer in the exchanger and transfers a larger share of its heat. If a project runs mostly at low speed, the annual efficiency is better than the headline figure, not worse.

Temperature efficiency and enthalpy efficiency are not the same number

The gap between them is the latent load. On the same model the gap is 6.8 points at high speed. In a humid climate, enthalpy efficiency is the figure that belongs in the calculation, because dehumidification is where the summer load actually sits.

The figures are measured with the standard G4 filter fitted

Selecting F7 on the supply side and M5 on the exhaust side raises filtration but adds static pressure. The DC motors absorb that, and the efficiency data for both configurations is published in the engineering manual, so a consultant can model either without applying a rule-of-thumb derating.

Three Compliance Anchors

For a European project, the equipment has to answer three separate regulations, and they are often confused with each other.

  • ErP 2009/125/EC is the Ecodesign framework directive. It sets the principle that energy-related products must meet minimum efficiency requirements to be placed on the market.
  • (EU) 327/2011 is the implementing regulation for fans. It sets minimum fan efficiency and, critically, requires the fan's efficiency to be declared at its actual operating point rather than at a best point on the curve.
  • (EU) 1253/2014 is the implementing regulation for ventilation units. It sets specific energy consumption limits for residential and non-residential ventilation units and defines the information that must be supplied with the product.

The DC series is compliant with all three, and holds CE marking along with ISO 9001, ISO 14001 and ISO 45001.

What this means in practice: the unit can be specified into a European project without a derogation, and the efficiency figures you put in the energy model are the ones the manufacturer declares, not an estimate.

Where the Annual Saving Actually Comes From

Recovery efficiency is only half the story. The other half is how often the unit runs at full speed when it does not need to.

  • CO₂ demand control. With the optional CO₂ sensor, the unit switches between four thresholds: it stops below 450 ppm, runs low at 550 ppm, medium at 800 ppm and high at 1,000 ppm. A meeting room at 9 am and the same room at 6 pm are not the same ventilation problem, and a constant-volume system treats them identically.
  • Bypass free cooling. When outdoor temperature is below indoor temperature, the bypass damper opens and incoming air skips the core entirely. In shoulder seasons, that is free cooling with no compressor running. It costs nothing to operate and it is the single most underused feature in recovery ventilation.
  • Scheduling. The WDC-120G/WK(A) controller adds weekly scheduling and delayed shutdown, so the unit does not run through an empty building at weekends.

A system with 82.8 percent recovery running at full speed 24 hours a day will be beaten on annual consumption by a system with 76 percent recovery that modulates. Recovery efficiency sets the ceiling. Control determines where on that ceiling you actually operate.

Efficiency Data — All Eight Models
Model Airflow Input power (H/M/L) Temp. efficiency (H/M/L) Enthalpy efficiency (H/M/L) Current External static pressure Sound pressure (H/M/L)
HRV-D200(B) 200 m³/h 70/45/25 W 79.5/81.1/83.5% 75.0/77.5/79.6% 0.64 A 100 Pa 33/29.5/25.5 dB(A)
HRV-D300(B) 300 m³/h 100/55/35 W 75.5/78.8/82.5% 72.1/75.0/79.3% 0.84 A 90 Pa 36.5/33.5/30 dB(A)
HRV-D400(B) 400 m³/h 110/70/40 W 77.7/79.0/81.3% 73.5/75.3/78.0% 0.97 A 100 Pa 36.5/32/28 dB(A)
HRV-D500(B) 500 m³/h 150/95/50 W 80.6/82.2/85.5% 74.0/76.6/80.5% 1.2 A 90 Pa 36/30.5/24.5 dB(A)
HRV-D800(B) 800 m³/h 320/170/80 W 78.7/82.1/86.8% 72.3/75.4/79.0% 2.4 A 140 Pa 42/39/34 dB(A)
HRV-D1000(B) 1,000 m³/h 380/210/100 W 82.8/84.0/87.4% 76.0/76.0/80.1% 2.9 A 160 Pa 44/39/33.5 dB(A)
HRV-D1500(B) 1,500 m³/h 680/320/200 W 75.5/78.6/80.2% 69.4/71.2/74.8% 3.8 A 180 Pa 51.5/46.5/41.5 dB(A)
HRV-D2000(B) 2,000 m³/h 950/500/230 W 77.2/79.5/83.4% 74.7/77.0/80.6% 5.7 A 200 Pa 53/48.5/42.5 dB(A)

Notes: all models have three fan speeds; the single values in the table are measured at high speed. Sound pressure is measured 1.5 m below the unit. Efficiency figures are with the standard G4 filter; F7 plus M5 data is in the engineering manual. Operating range −7 °C to +43 °C, indoor humidity below 80 percent.

Certification

CE. ErP 2009/125/EC. (EU) 327/2011. (EU) 1253/2014. ISO 9001, ISO 14001, ISO 45001.

Specify It Into Your Project

Send us the airflow requirement, the outdoor design temperature and the destination country. We will return the model, the recovery efficiency at your operating point and the calculated reduction in connected load, in a format you can drop into your energy model.

Full DC heat recovery ventilator unit exterior view showing supply and exhaust connections
Full DC heat recovery ventilator — exterior view.
Heat recovery ventilator treated paper enthalpy exchange core and DC fan assembly detail
Chemically treated paper enthalpy exchange core and DC fan assembly.
Products
PRODUCTS DETAILS
Full DC Heat Recovery Ventilator max temperature efficiency up to 82 minimum power 70W Compliant with ErP and EU 327 2011 airflow range 200 2000
Detail Information
Place of Origin
China
Brand Name
OEM;MIDEA
Certification
CB,ISO
Product Name:
Midea DC Series HRV
Airflow:
200 M³/h-2000 M³/h
Dimensions L X W X H:
1,195 X 801 X 272 Mm-1,811 X 1,575 X 685 Mm
Net / Gross Weight:
53.6 / 70.6 Kg-208.5 / 245 Kg
Spigot:
144 Mm-346 X 326 Mm
External Static Pressure:
100 Pa-200 Pa
Condensate Drain:
Not Required/PVC Required
Highlight

DC heat recovery ventilator

,

82% temperature efficiency ventilator

,

ErP compliant 70W ventilator

Product Description
Full DC Heat Recovery Ventilator — 200 to 2,000 m³/h

Maximum temperature efficiency up to 82.8%, minimum input power 70 W, compliant with ErP 2009/125/EC and (EU) 327/2011.

Airflow range: 200–2,000 m³/h Temp. efficiency up to 82.8% Min. input power: 70 W Full DC supply & exhaust fans CE · ErP · ISO 9001/14001/45001
Fresh Air Is a Line Item Nobody Budgets For

Every building has to bring in outdoor air. The moment it does, the air conditioning system inherits a load it never asked for: in winter that air has to be heated, in summer it has to be cooled and dehumidified, and the bill arrives every hour the building is occupied.

For a 1,000 m³/h system running between 20 °C indoors and −5 °C outdoors, that load is 8.38 kW of heating before a single person walks into the room. Nothing is wrong with the equipment. The load is simply the cost of ventilation.

A heat recovery ventilator takes most of that cost back. Two air streams, supply and exhaust, pass through a treated paper core without mixing. Heat and moisture move from the warmer stream to the colder one. The ventilation rate stays exactly where the standard requires it, and the load the cooling or heating plant has to cover drops sharply.

This is the part that matters commercially: recovery efficiency is not a comfort feature. It is a reduction in connected load, in plant capacity and in the operating budget — and it is measurable before the equipment is ordered.

What 82.8 Percent Actually Buys You

Take the same 1,000 m³/h system, HRV-D1000 at high speed, and run the numbers on both sides of the year.

Condition Load without recovery Load with 82.8% recovery Saved
Winter, −5 °C outdoor, 20 °C indoor 8.38 kW 1.44 kW 6.93 kW
Summer, 35 °C outdoor, 26 °C indoor 3.01 kW 0.52 kW 2.50 kW

Basis: air density 1.2 kg/m³, specific heat 1.005 kJ/kg·K, sensible only. Latent load in summer is additional and is carried by the enthalpy exchange.

At 2,000 operating hours a year, the winter case alone returns roughly 13,870 kWh. At an industrial electricity price of EUR 0.15 per kWh, that is about EUR 2,080 a year from one ventilator. The unit draws 380 W at high speed. It is not a close comparison.

Three things drive that number, and they are worth checking separately when you compare products.

  • The core. Temperature efficiency peaks at 82.8 percent on the 1,000 m³/h model, with enthalpy efficiency at 76.0 percent. The core is a chemically treated paper exchanger, which is why moisture moves as vapour rather than condensing into a drain pan.
  • The motors. Both the supply and exhaust fans are DC. Minimum input across the range is 70 W on the 200 m³/h model, and every model meets ErP 2009/125/EC and (EU) 327/2011. A DC fan also holds efficiency better at part load, which matters because most of the year the unit is not running at high speed.
  • The control. Efficiency at full speed is a laboratory number. Efficiency across a year is a control question, covered below.
Reading the Efficiency Figures Correctly

Three notes that most datasheets leave out.

Low speed is more efficient than high speed

On HRV-D1000, temperature efficiency is 82.8 percent at high speed, 84.0 at medium and 87.4 at low. The same pattern holds across the range. This is normal for a fixed core: at lower airflow, the air spends longer in the exchanger and transfers a larger share of its heat. If a project runs mostly at low speed, the annual efficiency is better than the headline figure, not worse.

Temperature efficiency and enthalpy efficiency are not the same number

The gap between them is the latent load. On the same model the gap is 6.8 points at high speed. In a humid climate, enthalpy efficiency is the figure that belongs in the calculation, because dehumidification is where the summer load actually sits.

The figures are measured with the standard G4 filter fitted

Selecting F7 on the supply side and M5 on the exhaust side raises filtration but adds static pressure. The DC motors absorb that, and the efficiency data for both configurations is published in the engineering manual, so a consultant can model either without applying a rule-of-thumb derating.

Three Compliance Anchors

For a European project, the equipment has to answer three separate regulations, and they are often confused with each other.

  • ErP 2009/125/EC is the Ecodesign framework directive. It sets the principle that energy-related products must meet minimum efficiency requirements to be placed on the market.
  • (EU) 327/2011 is the implementing regulation for fans. It sets minimum fan efficiency and, critically, requires the fan's efficiency to be declared at its actual operating point rather than at a best point on the curve.
  • (EU) 1253/2014 is the implementing regulation for ventilation units. It sets specific energy consumption limits for residential and non-residential ventilation units and defines the information that must be supplied with the product.

The DC series is compliant with all three, and holds CE marking along with ISO 9001, ISO 14001 and ISO 45001.

What this means in practice: the unit can be specified into a European project without a derogation, and the efficiency figures you put in the energy model are the ones the manufacturer declares, not an estimate.

Where the Annual Saving Actually Comes From

Recovery efficiency is only half the story. The other half is how often the unit runs at full speed when it does not need to.

  • CO₂ demand control. With the optional CO₂ sensor, the unit switches between four thresholds: it stops below 450 ppm, runs low at 550 ppm, medium at 800 ppm and high at 1,000 ppm. A meeting room at 9 am and the same room at 6 pm are not the same ventilation problem, and a constant-volume system treats them identically.
  • Bypass free cooling. When outdoor temperature is below indoor temperature, the bypass damper opens and incoming air skips the core entirely. In shoulder seasons, that is free cooling with no compressor running. It costs nothing to operate and it is the single most underused feature in recovery ventilation.
  • Scheduling. The WDC-120G/WK(A) controller adds weekly scheduling and delayed shutdown, so the unit does not run through an empty building at weekends.

A system with 82.8 percent recovery running at full speed 24 hours a day will be beaten on annual consumption by a system with 76 percent recovery that modulates. Recovery efficiency sets the ceiling. Control determines where on that ceiling you actually operate.

Efficiency Data — All Eight Models
Model Airflow Input power (H/M/L) Temp. efficiency (H/M/L) Enthalpy efficiency (H/M/L) Current External static pressure Sound pressure (H/M/L)
HRV-D200(B) 200 m³/h 70/45/25 W 79.5/81.1/83.5% 75.0/77.5/79.6% 0.64 A 100 Pa 33/29.5/25.5 dB(A)
HRV-D300(B) 300 m³/h 100/55/35 W 75.5/78.8/82.5% 72.1/75.0/79.3% 0.84 A 90 Pa 36.5/33.5/30 dB(A)
HRV-D400(B) 400 m³/h 110/70/40 W 77.7/79.0/81.3% 73.5/75.3/78.0% 0.97 A 100 Pa 36.5/32/28 dB(A)
HRV-D500(B) 500 m³/h 150/95/50 W 80.6/82.2/85.5% 74.0/76.6/80.5% 1.2 A 90 Pa 36/30.5/24.5 dB(A)
HRV-D800(B) 800 m³/h 320/170/80 W 78.7/82.1/86.8% 72.3/75.4/79.0% 2.4 A 140 Pa 42/39/34 dB(A)
HRV-D1000(B) 1,000 m³/h 380/210/100 W 82.8/84.0/87.4% 76.0/76.0/80.1% 2.9 A 160 Pa 44/39/33.5 dB(A)
HRV-D1500(B) 1,500 m³/h 680/320/200 W 75.5/78.6/80.2% 69.4/71.2/74.8% 3.8 A 180 Pa 51.5/46.5/41.5 dB(A)
HRV-D2000(B) 2,000 m³/h 950/500/230 W 77.2/79.5/83.4% 74.7/77.0/80.6% 5.7 A 200 Pa 53/48.5/42.5 dB(A)

Notes: all models have three fan speeds; the single values in the table are measured at high speed. Sound pressure is measured 1.5 m below the unit. Efficiency figures are with the standard G4 filter; F7 plus M5 data is in the engineering manual. Operating range −7 °C to +43 °C, indoor humidity below 80 percent.

Certification

CE. ErP 2009/125/EC. (EU) 327/2011. (EU) 1253/2014. ISO 9001, ISO 14001, ISO 45001.

Specify It Into Your Project

Send us the airflow requirement, the outdoor design temperature and the destination country. We will return the model, the recovery efficiency at your operating point and the calculated reduction in connected load, in a format you can drop into your energy model.

Full DC heat recovery ventilator unit exterior view showing supply and exhaust connections
Full DC heat recovery ventilator — exterior view.
Heat recovery ventilator treated paper enthalpy exchange core and DC fan assembly detail
Chemically treated paper enthalpy exchange core and DC fan assembly.