HRV with G4 Standard and F7 M5 Optional Filtration F7 Supply and M5 Exhaust Filters for EU Air Quality Classes HRV Filter Replacement: Differential Pressure Alarm

HRV with G4 Standard and F7 M5 Optional Filtration F7 Supply and M5 Exhaust Filters for EU Air Quality Classes HRV Filter Replacement: Differential Pressure Alarm

Detail Information
Place of Origin
China
Brand Name
OEM;MIDEA
Certification
CB,ISO
Product Name:
Midea DC Series HRV
Airflow:
200 M³/h-2000 M³/h
Dimensions L X W X H:
1,195 X 801 X 272 Mm-1,811 X 1,575 X 685 Mm
Net / Gross Weight:
53.6 / 70.6 Kg-208.5 / 245 Kg
Spigot:
144 Mm-346 X 326 Mm
External Static Pressure:
100 Pa-200 Pa
Condensate Drain:
Not Required/PVC Required
Highlight:

HRV G4 standard filtration

,

F7 M5 optional filters

,

HRV filter replacement alarm

Product Description
Product Overview

Filtration is the part of a ventilation specification that decides how often someone has to climb into the ceiling. The DC Series fits G4 filters as standard on both the supply and exhaust air streams, with F7 on the supply side and M5 on the exhaust side available as options for projects that quote an EU air-quality class. Because both configurations are covered in the engineering manual with published efficiency data, the specification can be modelled rather than guessed.

The filter grade does not depend on which of the eight sizes is selected. A 200 m³/h unit in a villa and a 2,000 m³/h unit on a restaurant floor use the same platform, the same filter positions and the same access panel arrangement. That matters on mixed-use projects, where the ventilation schedule may call for three sizes but only one maintenance procedure.

Filter condition is monitored rather than assumed. A differential pressure sensor watches the loading on the filters and raises a replacement indication on the controller before airflow drops far enough to affect ventilation rates. Filters are washable or vacuum-cleanable, so routine service is a cleaning task rather than a consumable order — and the core behind them needs vacuuming only about every two years, never washing.

Key Selling Points
  • G4 Standard on Both Streams — Supply and exhaust filters fitted as standard across all eight sizes.
  • F7 Supply and M5 Exhaust Optional — Meets tighter EU air-quality specifications for schools, clinics and premium offices.
  • Filter Grade Independent of Size — The same filter platform applies from 200 to 2,000 m³/h.
  • Differential Pressure Monitoring — Sensor raises a replacement indication on the controller before airflow degrades.
  • Washable Filters — Routine service is cleaning, not consumable replacement.
  • Efficiency Data Published for Both Configurations — No rule-of-thumb derating when specifying F7 and M5.
  • DC Motors Absorb the Extra Static Pressure — The upgrade does not require a larger model.
  • Core Maintenance Kept Simple — Vacuum approximately every two years, never wash; fans inspected every six months.
Filter Configuration
Project requirementSupply filterExhaust filter
Standard commercial ventilationG4G4
Projects quoting an EU air-quality classF7M5

Configurations outside these two should be confirmed with the factory before the specification is issued.

What Changes When You Upgrade to F7 and M5
Pressure drop rises, and the DC motors absorb it

A finer filter adds resistance on the supply side. Because both fans are DC, the unit holds its design airflow without stepping up to the next model size — the trade-off appears in input power, not in airflow.

Efficiency figures shift, and the revised data is published

The headline 82.8% temperature efficiency and 76.0% enthalpy efficiency are measured with the standard G4 filter. Data for the F7 and M5 configuration is published in the engineering manual, so an energy model can use the correct figures instead of a percentage-point assumption.

Maintenance intervals shorten slightly

Finer filters load faster in dusty or high-occupancy environments. The differential pressure sensor is what tells you when, rather than a fixed calendar interval.

Filter Status and Replacement

The unit carries a differential pressure sensor across the filter section. As the filters load, resistance rises; when it reaches the set point, the controller raises a replacement indication. Because the signal is pressure-based rather than time-based, it responds to the actual environment — a unit beside a construction site and a unit in a clean office do not need the same interval.

Filters are washable or vacuum-cleanable. Wash, dry fully, refit, and the pressure reading returns to its baseline. Where a project prefers replacement over cleaning, the same filter frames accept new media.

Maintenance Schedule
ComponentIntervalMethod
Supply and exhaust filtersOn controller indicationWash or vacuum-clean; dry fully before refitting
Heat exchange coreApproximately every two yearsVacuum only; never wash with water
FansEvery six monthsInspect for dust build-up and balance
Drain (HRV-D1500, D2000 only)At service visitsConfirm slope and trap are clear
Access panelEvery service visitConfirm the panel is reachable after ceiling closure
Application by Air-Quality Requirement
SpaceTypical requirementConfiguration
Office, retail, restaurant, hotelEnergy-efficient ventilation, low pressure dropG4 standard
School, training centreHigher supply air qualityF7 supply, M5 exhaust
Clinic, healthcare areaFiltration plus balanced supply and exhaustF7 supply, M5 exhaust
Premium office, showroomHigher supply air quality with BMS monitoringF7 supply, M5 exhaust
Apartment, villaStandard residential ventilationG4 standard
Technical Data
Model Airflow Input power (H/M/L) Temp. efficiency (H/M/L) Enthalpy efficiency (H/M/L) Current External static pressure Sound pressure (H/M/L)
HRV-D200(B)200 m³/h70/45/25 W79.5/81.1/83.5%75.0/77.5/79.6%0.64 A100 Pa33/29.5/25.5 dB(A)
HRV-D300(B)300 m³/h100/55/35 W75.5/78.8/82.5%72.1/75.0/79.3%0.84 A90 Pa36.5/33.5/30 dB(A)
HRV-D400(B)400 m³/h110/70/40 W77.7/79.0/81.3%73.5/75.3/78.0%0.97 A100 Pa36.5/32/28 dB(A)
HRV-D500(B)500 m³/h150/95/50 W80.6/82.2/85.5%74.0/76.6/80.5%1.2 A90 Pa36/30.5/24.5 dB(A)
HRV-D800(B)800 m³/h320/170/80 W78.7/82.1/86.8%72.3/75.4/79.0%2.4 A140 Pa42/39/34 dB(A)
HRV-D1000(B)1,000 m³/h380/210/100 W82.8/84.0/87.4%76.0/76.0/80.1%2.9 A160 Pa44/39/33.5 dB(A)
HRV-D1500(B)1,500 m³/h680/320/200 W75.5/78.6/80.2%69.4/71.2/74.8%3.8 A180 Pa51.5/46.5/41.5 dB(A)
HRV-D2000(B)2,000 m³/h950/500/230 W77.2/79.5/83.4%74.7/77.0/80.6%5.7 A200 Pa53/48.5/42.5 dB(A)

Notes: three fan speeds on all models; single values measured at high speed. Sound pressure measured 1.5 m below the unit. Efficiency figures are measured with the standard G4 filter; F7 plus M5 data is published in the engineering manual. Operating range -7 °C to +43 °C, indoor humidity below 80%. Only HRV-D1500 and D2000 require a PVC drain.

FAQ
Q: What filters come as standard?

A: G4 on both the supply and the exhaust air streams, on all eight sizes.

Q: When should I specify F7 and M5?

A: Where the project quotes an EU air-quality class — schools, clinics, healthcare areas and premium offices. Offices, retail, restaurants, hotels and apartments normally run the standard G4 configuration.

Q: Does upgrading the filters reduce airflow?

A: No. The DC fans absorb the additional resistance and hold the design airflow. The trade-off appears in input power, not in delivered air volume.

Q: Are the published efficiency figures based on G4 or F7?

A: The headline 82.8% temperature efficiency and 76.0% enthalpy efficiency are with the standard G4 filter. F7 and M5 figures are published in the engineering manual for modelling.

Q: How do I know when to change the filters?

A: The differential pressure sensor raises an indication on the controller when resistance reaches the set point. The interval follows the actual environment rather than a fixed calendar.

Q: Can the filters be washed instead of replaced?

A: Yes. Both are washable or vacuum-cleanable. Dry them fully before refitting so the pressure reading returns to baseline.

Q: Can the heat exchange core be washed?

A: No. Vacuum it approximately every two years. Washing damages the treated paper and reduces moisture transfer.

Related Search Terms
  • hrv filtration
  • f7 filter heat recovery ventilator
  • m5 filter erv
  • g4 filter ventilation unit
  • hrv filter replacement indicator
  • classroom ventilation filter
  • clinic ventilation filtration
  • heat recovery ventilator filter grades
Products
PRODUCTS DETAILS
HRV with G4 Standard and F7 M5 Optional Filtration F7 Supply and M5 Exhaust Filters for EU Air Quality Classes HRV Filter Replacement: Differential Pressure Alarm
Detail Information
Place of Origin
China
Brand Name
OEM;MIDEA
Certification
CB,ISO
Product Name:
Midea DC Series HRV
Airflow:
200 M³/h-2000 M³/h
Dimensions L X W X H:
1,195 X 801 X 272 Mm-1,811 X 1,575 X 685 Mm
Net / Gross Weight:
53.6 / 70.6 Kg-208.5 / 245 Kg
Spigot:
144 Mm-346 X 326 Mm
External Static Pressure:
100 Pa-200 Pa
Condensate Drain:
Not Required/PVC Required
Highlight

HRV G4 standard filtration

,

F7 M5 optional filters

,

HRV filter replacement alarm

Product Description
Product Overview

Filtration is the part of a ventilation specification that decides how often someone has to climb into the ceiling. The DC Series fits G4 filters as standard on both the supply and exhaust air streams, with F7 on the supply side and M5 on the exhaust side available as options for projects that quote an EU air-quality class. Because both configurations are covered in the engineering manual with published efficiency data, the specification can be modelled rather than guessed.

The filter grade does not depend on which of the eight sizes is selected. A 200 m³/h unit in a villa and a 2,000 m³/h unit on a restaurant floor use the same platform, the same filter positions and the same access panel arrangement. That matters on mixed-use projects, where the ventilation schedule may call for three sizes but only one maintenance procedure.

Filter condition is monitored rather than assumed. A differential pressure sensor watches the loading on the filters and raises a replacement indication on the controller before airflow drops far enough to affect ventilation rates. Filters are washable or vacuum-cleanable, so routine service is a cleaning task rather than a consumable order — and the core behind them needs vacuuming only about every two years, never washing.

Key Selling Points
  • G4 Standard on Both Streams — Supply and exhaust filters fitted as standard across all eight sizes.
  • F7 Supply and M5 Exhaust Optional — Meets tighter EU air-quality specifications for schools, clinics and premium offices.
  • Filter Grade Independent of Size — The same filter platform applies from 200 to 2,000 m³/h.
  • Differential Pressure Monitoring — Sensor raises a replacement indication on the controller before airflow degrades.
  • Washable Filters — Routine service is cleaning, not consumable replacement.
  • Efficiency Data Published for Both Configurations — No rule-of-thumb derating when specifying F7 and M5.
  • DC Motors Absorb the Extra Static Pressure — The upgrade does not require a larger model.
  • Core Maintenance Kept Simple — Vacuum approximately every two years, never wash; fans inspected every six months.
Filter Configuration
Project requirementSupply filterExhaust filter
Standard commercial ventilationG4G4
Projects quoting an EU air-quality classF7M5

Configurations outside these two should be confirmed with the factory before the specification is issued.

What Changes When You Upgrade to F7 and M5
Pressure drop rises, and the DC motors absorb it

A finer filter adds resistance on the supply side. Because both fans are DC, the unit holds its design airflow without stepping up to the next model size — the trade-off appears in input power, not in airflow.

Efficiency figures shift, and the revised data is published

The headline 82.8% temperature efficiency and 76.0% enthalpy efficiency are measured with the standard G4 filter. Data for the F7 and M5 configuration is published in the engineering manual, so an energy model can use the correct figures instead of a percentage-point assumption.

Maintenance intervals shorten slightly

Finer filters load faster in dusty or high-occupancy environments. The differential pressure sensor is what tells you when, rather than a fixed calendar interval.

Filter Status and Replacement

The unit carries a differential pressure sensor across the filter section. As the filters load, resistance rises; when it reaches the set point, the controller raises a replacement indication. Because the signal is pressure-based rather than time-based, it responds to the actual environment — a unit beside a construction site and a unit in a clean office do not need the same interval.

Filters are washable or vacuum-cleanable. Wash, dry fully, refit, and the pressure reading returns to its baseline. Where a project prefers replacement over cleaning, the same filter frames accept new media.

Maintenance Schedule
ComponentIntervalMethod
Supply and exhaust filtersOn controller indicationWash or vacuum-clean; dry fully before refitting
Heat exchange coreApproximately every two yearsVacuum only; never wash with water
FansEvery six monthsInspect for dust build-up and balance
Drain (HRV-D1500, D2000 only)At service visitsConfirm slope and trap are clear
Access panelEvery service visitConfirm the panel is reachable after ceiling closure
Application by Air-Quality Requirement
SpaceTypical requirementConfiguration
Office, retail, restaurant, hotelEnergy-efficient ventilation, low pressure dropG4 standard
School, training centreHigher supply air qualityF7 supply, M5 exhaust
Clinic, healthcare areaFiltration plus balanced supply and exhaustF7 supply, M5 exhaust
Premium office, showroomHigher supply air quality with BMS monitoringF7 supply, M5 exhaust
Apartment, villaStandard residential ventilationG4 standard
Technical Data
Model Airflow Input power (H/M/L) Temp. efficiency (H/M/L) Enthalpy efficiency (H/M/L) Current External static pressure Sound pressure (H/M/L)
HRV-D200(B)200 m³/h70/45/25 W79.5/81.1/83.5%75.0/77.5/79.6%0.64 A100 Pa33/29.5/25.5 dB(A)
HRV-D300(B)300 m³/h100/55/35 W75.5/78.8/82.5%72.1/75.0/79.3%0.84 A90 Pa36.5/33.5/30 dB(A)
HRV-D400(B)400 m³/h110/70/40 W77.7/79.0/81.3%73.5/75.3/78.0%0.97 A100 Pa36.5/32/28 dB(A)
HRV-D500(B)500 m³/h150/95/50 W80.6/82.2/85.5%74.0/76.6/80.5%1.2 A90 Pa36/30.5/24.5 dB(A)
HRV-D800(B)800 m³/h320/170/80 W78.7/82.1/86.8%72.3/75.4/79.0%2.4 A140 Pa42/39/34 dB(A)
HRV-D1000(B)1,000 m³/h380/210/100 W82.8/84.0/87.4%76.0/76.0/80.1%2.9 A160 Pa44/39/33.5 dB(A)
HRV-D1500(B)1,500 m³/h680/320/200 W75.5/78.6/80.2%69.4/71.2/74.8%3.8 A180 Pa51.5/46.5/41.5 dB(A)
HRV-D2000(B)2,000 m³/h950/500/230 W77.2/79.5/83.4%74.7/77.0/80.6%5.7 A200 Pa53/48.5/42.5 dB(A)

Notes: three fan speeds on all models; single values measured at high speed. Sound pressure measured 1.5 m below the unit. Efficiency figures are measured with the standard G4 filter; F7 plus M5 data is published in the engineering manual. Operating range -7 °C to +43 °C, indoor humidity below 80%. Only HRV-D1500 and D2000 require a PVC drain.

FAQ
Q: What filters come as standard?

A: G4 on both the supply and the exhaust air streams, on all eight sizes.

Q: When should I specify F7 and M5?

A: Where the project quotes an EU air-quality class — schools, clinics, healthcare areas and premium offices. Offices, retail, restaurants, hotels and apartments normally run the standard G4 configuration.

Q: Does upgrading the filters reduce airflow?

A: No. The DC fans absorb the additional resistance and hold the design airflow. The trade-off appears in input power, not in delivered air volume.

Q: Are the published efficiency figures based on G4 or F7?

A: The headline 82.8% temperature efficiency and 76.0% enthalpy efficiency are with the standard G4 filter. F7 and M5 figures are published in the engineering manual for modelling.

Q: How do I know when to change the filters?

A: The differential pressure sensor raises an indication on the controller when resistance reaches the set point. The interval follows the actual environment rather than a fixed calendar.

Q: Can the filters be washed instead of replaced?

A: Yes. Both are washable or vacuum-cleanable. Dry them fully before refitting so the pressure reading returns to baseline.

Q: Can the heat exchange core be washed?

A: No. Vacuum it approximately every two years. Washing damages the treated paper and reduces moisture transfer.

Related Search Terms
  • hrv filtration
  • f7 filter heat recovery ventilator
  • m5 filter erv
  • g4 filter ventilation unit
  • hrv filter replacement indicator
  • classroom ventilation filter
  • clinic ventilation filtration
  • heat recovery ventilator filter grades