CO2-Controlled HRV with VRF Interlock 200-2000 m³/h Demand Control Ventilation HRV with Four CO2 Thresholds HRV and VRF Interlock One Controller for 16 Units

CO2-Controlled HRV with VRF Interlock 200-2000 m³/h Demand Control Ventilation HRV with Four CO2 Thresholds HRV and VRF Interlock One Controller for 16 Units

Detail Information
Place of Origin
China
Brand Name
OEM;MIDEA
Certification
CB,ISO
Product Name:
Midea DC Series HRV
Airflow:
200 M³/h-2000 M³/h
Dimensions L X W X H:
1,195 X 801 X 272 Mm-1,811 X 1,575 X 685 Mm
Net / Gross Weight:
53.6 / 70.6 Kg-208.5 / 245 Kg
Spigot:
144 Mm-346 X 326 Mm
External Static Pressure:
100 Pa-200 Pa
Condensate Drain:
Not Required/PVC Required
Highlight:

CO2-controlled HRV VRF interlock

,

demand control ventilation HRV 200-2000 m³/h

,

HRV controller for 16 units

Product Description
Product Overview

A fixed-speed heat recovery ventilator is a constant load, not a controlled one. The DC Series is engineered so ventilation follows occupancy instead of design peak: an optional CO2 sensor steps fan speed across four thresholds, the bypass damper switches to free cooling automatically, and the PQE port synchronises the unit with Midea VRF indoor units so air handling and ventilation start and stop together.

Control is layered by project size. A single KJR-27B/E wired controller covers five modes, four fan speeds including a sleep setting, and timer on/off, and can manage up to 16 units from one position. The WDC-120G/WK(A) controller adds CO2 concentration display, filter indication, group control, weekly timer, VRF interlock, delayed shutdown and parameter query — enough for a whole floor without a BMS. Above that, CCM-180A/WS(A) and CCM-270B/WS(A) centralised controllers bring HRV and VRF onto one panel for multi-floor management.

Handover to building management is a specification decision, not a retrofit. GW-MOD(A) delivers Modbus RTU and IMMP-BAC delivers BACnet, so ventilation points land in the BMS alongside the rest of the plant. Because the unit is DC-driven with a differential pressure sensor on the filters, the BMS also sees what maintenance needs to know: when a filter is loading up, before airflow drops.

Key Selling Points
  • CO2 Demand Control, Four Thresholds — Optional sensor steps the fan automatically: stop below 450 ppm, low at 550, medium at 800, high at 1,000 ppm
  • VRF Interlock via PQE Port — Ventilation starts and stops with Midea VRF indoor units; no separate schedule to maintain
  • One Controller, 16 Units — A single KJR-27B/E wired controller manages up to 16 HRV units from one position
  • Five Operating Modes — Auto, Heat Recovery, Bypass, Exhaust and Supply cover every season and occupancy pattern
  • Weekly Timer and Delayed Shutdown — WDC-120G/WK(A) prevents running hours in unoccupied buildings
  • Modbus and BACnet Gateways — GW-MOD(A) and IMMP-BAC hand ventilation points to the BMS contractor at handover
  • Filter Status on the Controller — Differential pressure sensor raises a replacement indication before airflow degrades
  • Centralised Control for Multi-Floor Projects — CCM-180A/WS(A) and CCM-270B/WS(A) manage HRV and VRF on one panel
Operating Modes
ModeBehaviourTypical Use
AutoCompares indoor and outdoor temperature, selects heat recovery or bypass, both fans at low speedEveryday operation
Heat RecoveryBoth air streams pass through the core; supply pre-cooled in summer, pre-warmed in winterHeating and cooling seasons
BypassFresh air routes around the core for free cooling; supply and exhaust at matched speedShoulder seasons, night purge
ExhaustExtract onlyKitchens, toilets, smoking areas
SupplyFresh air onlyPositive-pressure requirements
Control Devices
DeviceFunctionCapacity
KJR-27B/E wired controllerFive modes, four fan speeds including sleep, timer on/offUp to 16 units per controller
WDC-120G/WK(A) wired controllerCO2 display, filter indication, group control, weekly timer, VRF interlock, delayed shutdown, parameter queryGroup and floor level
CCM-180A/WS(A) centralised controllerHRV and VRF managed together by floor and zoneMulti-floor projects
CCM-270B/WS(A) centralised controllerCentralised monitoring and control of HRV and VRFMulti-floor projects
GW-MOD(A) gatewayModbus RTU interface to the BMSPer project
IMMP-BAC gatewayBACnet interface to the BMSPer project
PQE portInterlock with Midea VRF indoor unitsPer unit
CO2 sensor box (optional)Demand-controlled ventilationPer unit
CO2 Demand Control

The optional CO2 sensor converts the unit from constant volume to demand-controlled ventilation. Fan speed steps automatically as concentration crosses each threshold, so a meeting room used eight hours a day does not run at design airflow for the other sixteen.

CO2 ConcentrationFan Response
Below 450 ppmStop
550 ppmLow speed
800 ppmMedium speed
1,000 ppmHigh speed

Thresholds are set at commissioning against the project's ventilation strategy. Where a space has a known peak occupancy, the 1,000 ppm step should correspond to design airflow so the unit can still meet the calculated requirement at full occupancy.

VRF Interlock and Centralised Control

The PQE port links the HRV to Midea VRF indoor units, so ventilation follows the air conditioning rather than a separate time schedule. In practice this removes the most common operational failure on commercial floors: air conditioning switched off while the ventilator still runs, or the reverse. One KJR-27B/E controller can manage up to 16 units, which covers a typical floor from a single position without a BMS.

Where the project spans multiple floors or zones, CCM-180A/WS(A) and CCM-270B/WS(A) centralised controllers put HRV and VRF on the same panel, giving facility staff one interface instead of two systems.

BMS Gateways
  • GW-MOD(A) — Modbus RTU; the gateway maps the unit's control and status points into registers for the BMS
  • IMMP-BAC — BACnet; the same points are exposed as objects for the building management system
  • Point list — issued at order stage so the BMS contractor can schedule points before delivery rather than after
  • Protocol at order — specify Modbus or BACnet when ordering so the gateway ships with the units, not as a later retrofit
  • Fallback — the unit runs standalone on its wired controller if the BMS is unavailable; gateway failure does not stop ventilation
Commissioning and Handover
  1. Set the mode strategy — Confirm whether Auto or a fixed mode suits the space; Auto needs reliable indoor and outdoor temperature sensing
  2. Set CO2 thresholds — Align the 1,000 ppm step with design airflow, then confirm the lower steps against expected occupancy
  3. Confirm the interlock — Verify the HRV starts and stops with the VRF indoor units it is grouped with
  4. Address the gateway — Assign the Modbus address or BACnet device instance before the BMS contractor polls the bus
  5. Verify points — Read back status, mode, fan speed and filter indication at the BMS head end
  6. Log the handover — Record mode settings, thresholds, addresses and the point list for the O&M manual
Technical Data
Model Airflow Input Power (H/M/L) Temp. Efficiency (H/M/L) Enthalpy Efficiency (H/M/L) Current External Static Pressure Sound Pressure (H/M/L)
HRV-D200(B)200 m³/h70/45/25 W79.5/81.1/83.5%75.0/77.5/79.6%0.64 A100 Pa33/29.5/25.5 dB(A)
HRV-D300(B)300 m³/h100/55/35 W75.5/78.8/82.5%72.1/75.0/79.3%0.84 A90 Pa36.5/33.5/30 dB(A)
HRV-D400(B)400 m³/h110/70/40 W77.7/79.0/81.3%73.5/75.3/78.0%0.97 A100 Pa36.5/32/28 dB(A)
HRV-D500(B)500 m³/h150/95/50 W80.6/82.2/85.5%74.0/76.6/80.5%1.2 A90 Pa36/30.5/24.5 dB(A)
HRV-D800(B)800 m³/h320/170/80 W78.7/82.1/86.8%72.3/75.4/79.0%2.4 A140 Pa42/39/34 dB(A)
HRV-D1000(B)1,000 m³/h380/210/100 W82.8/84.0/87.4%76.0/76.0/80.1%2.9 A160 Pa44/39/33.5 dB(A)
HRV-D1500(B)1,500 m³/h680/320/200 W75.5/78.6/80.2%69.4/71.2/74.8%3.8 A180 Pa51.5/46.5/41.5 dB(A)
HRV-D2000(B)2,000 m³/h950/500/230 W77.2/79.5/83.4%74.7/77.0/80.6%5.7 A200 Pa53/48.5/42.5 dB(A)
Notes: three fan speeds on all models; single values measured at high speed. Sound pressure measured 1.5 m below the unit. Efficiency figures with the standard G4 filter; F7 plus M5 data published in the engineering manual. Operating range -7 °C to +43 °C, indoor humidity below 80%. Power supply 220-240 V, single-phase, 50 Hz on all sizes.
FAQ
Do I need a separate controller for CO2 control?

The CO2 sensor box is an option and works with the WDC-120G/WK(A) controller, which displays concentration and manages the four thresholds. The KJR-27B/E controller covers the five operating modes and fan speeds.

Can one controller manage several units?

Yes. A single KJR-27B/E controller manages up to 16 units, and the WDC-120G/WK(A) adds group control for floor-level management.

How does the VRF interlock work in practice?

The PQE port connects the HRV to Midea VRF indoor units, so the ventilator starts and stops with the air conditioning group it belongs to. There is no separate time schedule to keep in step.

What does the BMS gateway expose?

The gateway maps the unit's control and status points into Modbus registers or BACnet objects. The point list is issued at order stage so the BMS contractor can schedule it before delivery.

Can the unit run without a BMS?

Yes. All functions are available from the wired controller. If the BMS or gateway is unavailable, ventilation continues on local control.

Can CO2 thresholds be changed after commissioning?

They are set at commissioning against the ventilation strategy, and can be revised on site when occupancy patterns change. Record any change in the O&M manual.

What cabling is needed between controller and unit?

A low-voltage control cable from the controller position to the unit, in addition to the single-phase 220-240 V power supply. Route control cable separately from power cable.

Related Search Terms
  • co2 demand control ventilation
  • hrv vrf interlock
  • modbus hrv gateway
  • bacnet ventilation controller
  • heat recovery ventilator bms
  • multi unit ventilation controller
  • co2 sensor ventilation
  • smart ventilation control
Products
PRODUCTS DETAILS
CO2-Controlled HRV with VRF Interlock 200-2000 m³/h Demand Control Ventilation HRV with Four CO2 Thresholds HRV and VRF Interlock One Controller for 16 Units
Detail Information
Place of Origin
China
Brand Name
OEM;MIDEA
Certification
CB,ISO
Product Name:
Midea DC Series HRV
Airflow:
200 M³/h-2000 M³/h
Dimensions L X W X H:
1,195 X 801 X 272 Mm-1,811 X 1,575 X 685 Mm
Net / Gross Weight:
53.6 / 70.6 Kg-208.5 / 245 Kg
Spigot:
144 Mm-346 X 326 Mm
External Static Pressure:
100 Pa-200 Pa
Condensate Drain:
Not Required/PVC Required
Highlight

CO2-controlled HRV VRF interlock

,

demand control ventilation HRV 200-2000 m³/h

,

HRV controller for 16 units

Product Description
Product Overview

A fixed-speed heat recovery ventilator is a constant load, not a controlled one. The DC Series is engineered so ventilation follows occupancy instead of design peak: an optional CO2 sensor steps fan speed across four thresholds, the bypass damper switches to free cooling automatically, and the PQE port synchronises the unit with Midea VRF indoor units so air handling and ventilation start and stop together.

Control is layered by project size. A single KJR-27B/E wired controller covers five modes, four fan speeds including a sleep setting, and timer on/off, and can manage up to 16 units from one position. The WDC-120G/WK(A) controller adds CO2 concentration display, filter indication, group control, weekly timer, VRF interlock, delayed shutdown and parameter query — enough for a whole floor without a BMS. Above that, CCM-180A/WS(A) and CCM-270B/WS(A) centralised controllers bring HRV and VRF onto one panel for multi-floor management.

Handover to building management is a specification decision, not a retrofit. GW-MOD(A) delivers Modbus RTU and IMMP-BAC delivers BACnet, so ventilation points land in the BMS alongside the rest of the plant. Because the unit is DC-driven with a differential pressure sensor on the filters, the BMS also sees what maintenance needs to know: when a filter is loading up, before airflow drops.

Key Selling Points
  • CO2 Demand Control, Four Thresholds — Optional sensor steps the fan automatically: stop below 450 ppm, low at 550, medium at 800, high at 1,000 ppm
  • VRF Interlock via PQE Port — Ventilation starts and stops with Midea VRF indoor units; no separate schedule to maintain
  • One Controller, 16 Units — A single KJR-27B/E wired controller manages up to 16 HRV units from one position
  • Five Operating Modes — Auto, Heat Recovery, Bypass, Exhaust and Supply cover every season and occupancy pattern
  • Weekly Timer and Delayed Shutdown — WDC-120G/WK(A) prevents running hours in unoccupied buildings
  • Modbus and BACnet Gateways — GW-MOD(A) and IMMP-BAC hand ventilation points to the BMS contractor at handover
  • Filter Status on the Controller — Differential pressure sensor raises a replacement indication before airflow degrades
  • Centralised Control for Multi-Floor Projects — CCM-180A/WS(A) and CCM-270B/WS(A) manage HRV and VRF on one panel
Operating Modes
ModeBehaviourTypical Use
AutoCompares indoor and outdoor temperature, selects heat recovery or bypass, both fans at low speedEveryday operation
Heat RecoveryBoth air streams pass through the core; supply pre-cooled in summer, pre-warmed in winterHeating and cooling seasons
BypassFresh air routes around the core for free cooling; supply and exhaust at matched speedShoulder seasons, night purge
ExhaustExtract onlyKitchens, toilets, smoking areas
SupplyFresh air onlyPositive-pressure requirements
Control Devices
DeviceFunctionCapacity
KJR-27B/E wired controllerFive modes, four fan speeds including sleep, timer on/offUp to 16 units per controller
WDC-120G/WK(A) wired controllerCO2 display, filter indication, group control, weekly timer, VRF interlock, delayed shutdown, parameter queryGroup and floor level
CCM-180A/WS(A) centralised controllerHRV and VRF managed together by floor and zoneMulti-floor projects
CCM-270B/WS(A) centralised controllerCentralised monitoring and control of HRV and VRFMulti-floor projects
GW-MOD(A) gatewayModbus RTU interface to the BMSPer project
IMMP-BAC gatewayBACnet interface to the BMSPer project
PQE portInterlock with Midea VRF indoor unitsPer unit
CO2 sensor box (optional)Demand-controlled ventilationPer unit
CO2 Demand Control

The optional CO2 sensor converts the unit from constant volume to demand-controlled ventilation. Fan speed steps automatically as concentration crosses each threshold, so a meeting room used eight hours a day does not run at design airflow for the other sixteen.

CO2 ConcentrationFan Response
Below 450 ppmStop
550 ppmLow speed
800 ppmMedium speed
1,000 ppmHigh speed

Thresholds are set at commissioning against the project's ventilation strategy. Where a space has a known peak occupancy, the 1,000 ppm step should correspond to design airflow so the unit can still meet the calculated requirement at full occupancy.

VRF Interlock and Centralised Control

The PQE port links the HRV to Midea VRF indoor units, so ventilation follows the air conditioning rather than a separate time schedule. In practice this removes the most common operational failure on commercial floors: air conditioning switched off while the ventilator still runs, or the reverse. One KJR-27B/E controller can manage up to 16 units, which covers a typical floor from a single position without a BMS.

Where the project spans multiple floors or zones, CCM-180A/WS(A) and CCM-270B/WS(A) centralised controllers put HRV and VRF on the same panel, giving facility staff one interface instead of two systems.

BMS Gateways
  • GW-MOD(A) — Modbus RTU; the gateway maps the unit's control and status points into registers for the BMS
  • IMMP-BAC — BACnet; the same points are exposed as objects for the building management system
  • Point list — issued at order stage so the BMS contractor can schedule points before delivery rather than after
  • Protocol at order — specify Modbus or BACnet when ordering so the gateway ships with the units, not as a later retrofit
  • Fallback — the unit runs standalone on its wired controller if the BMS is unavailable; gateway failure does not stop ventilation
Commissioning and Handover
  1. Set the mode strategy — Confirm whether Auto or a fixed mode suits the space; Auto needs reliable indoor and outdoor temperature sensing
  2. Set CO2 thresholds — Align the 1,000 ppm step with design airflow, then confirm the lower steps against expected occupancy
  3. Confirm the interlock — Verify the HRV starts and stops with the VRF indoor units it is grouped with
  4. Address the gateway — Assign the Modbus address or BACnet device instance before the BMS contractor polls the bus
  5. Verify points — Read back status, mode, fan speed and filter indication at the BMS head end
  6. Log the handover — Record mode settings, thresholds, addresses and the point list for the O&M manual
Technical Data
Model Airflow Input Power (H/M/L) Temp. Efficiency (H/M/L) Enthalpy Efficiency (H/M/L) Current External Static Pressure Sound Pressure (H/M/L)
HRV-D200(B)200 m³/h70/45/25 W79.5/81.1/83.5%75.0/77.5/79.6%0.64 A100 Pa33/29.5/25.5 dB(A)
HRV-D300(B)300 m³/h100/55/35 W75.5/78.8/82.5%72.1/75.0/79.3%0.84 A90 Pa36.5/33.5/30 dB(A)
HRV-D400(B)400 m³/h110/70/40 W77.7/79.0/81.3%73.5/75.3/78.0%0.97 A100 Pa36.5/32/28 dB(A)
HRV-D500(B)500 m³/h150/95/50 W80.6/82.2/85.5%74.0/76.6/80.5%1.2 A90 Pa36/30.5/24.5 dB(A)
HRV-D800(B)800 m³/h320/170/80 W78.7/82.1/86.8%72.3/75.4/79.0%2.4 A140 Pa42/39/34 dB(A)
HRV-D1000(B)1,000 m³/h380/210/100 W82.8/84.0/87.4%76.0/76.0/80.1%2.9 A160 Pa44/39/33.5 dB(A)
HRV-D1500(B)1,500 m³/h680/320/200 W75.5/78.6/80.2%69.4/71.2/74.8%3.8 A180 Pa51.5/46.5/41.5 dB(A)
HRV-D2000(B)2,000 m³/h950/500/230 W77.2/79.5/83.4%74.7/77.0/80.6%5.7 A200 Pa53/48.5/42.5 dB(A)
Notes: three fan speeds on all models; single values measured at high speed. Sound pressure measured 1.5 m below the unit. Efficiency figures with the standard G4 filter; F7 plus M5 data published in the engineering manual. Operating range -7 °C to +43 °C, indoor humidity below 80%. Power supply 220-240 V, single-phase, 50 Hz on all sizes.
FAQ
Do I need a separate controller for CO2 control?

The CO2 sensor box is an option and works with the WDC-120G/WK(A) controller, which displays concentration and manages the four thresholds. The KJR-27B/E controller covers the five operating modes and fan speeds.

Can one controller manage several units?

Yes. A single KJR-27B/E controller manages up to 16 units, and the WDC-120G/WK(A) adds group control for floor-level management.

How does the VRF interlock work in practice?

The PQE port connects the HRV to Midea VRF indoor units, so the ventilator starts and stops with the air conditioning group it belongs to. There is no separate time schedule to keep in step.

What does the BMS gateway expose?

The gateway maps the unit's control and status points into Modbus registers or BACnet objects. The point list is issued at order stage so the BMS contractor can schedule it before delivery.

Can the unit run without a BMS?

Yes. All functions are available from the wired controller. If the BMS or gateway is unavailable, ventilation continues on local control.

Can CO2 thresholds be changed after commissioning?

They are set at commissioning against the ventilation strategy, and can be revised on site when occupancy patterns change. Record any change in the O&M manual.

What cabling is needed between controller and unit?

A low-voltage control cable from the controller position to the unit, in addition to the single-phase 220-240 V power supply. Route control cable separately from power cable.

Related Search Terms
  • co2 demand control ventilation
  • hrv vrf interlock
  • modbus hrv gateway
  • bacnet ventilation controller
  • heat recovery ventilator bms
  • multi unit ventilation controller
  • co2 sensor ventilation
  • smart ventilation control