Large Heat Recovery Ventilator 1500-2000 m³/h 200 Pa 2000 m³/h HRV Rectangular Duct Spigot and PVC Drain Choosing a Large HRV for Restaurants Gyms and Open Floors

Large Heat Recovery Ventilator 1500-2000 m³/h 200 Pa 2000 m³/h HRV Rectangular Duct Spigot and PVC Drain Choosing a Large HRV for Restaurants Gyms and Open Floors

Detail Information
Place of Origin
China
Brand Name
OEM;MIDEA
Certification
CB,ISO
Product Name:
Midea DC Series HRV
Airflow:
200 M³/h-2000 M³/h
Dimensions L X W X H:
1,195 X 801 X 272 Mm-1,811 X 1,575 X 685 Mm
Net / Gross Weight:
53.6 / 70.6 Kg-208.5 / 245 Kg
Spigot:
144 Mm-346 X 326 Mm
External Static Pressure:
100 Pa-200 Pa
Condensate Drain:
Not Required/PVC Required
Highlight:

Large HRV 2000 m³/h

,

Rectangular Duct Spigot HRV

,

Large Heat Recovery Ventilator 200 Pa

Product Description
Product Overview

The two large sizes in the DC series deliver 1,500 and 2,000 m³/h against 180 and 200 Pa of external static pressure, through 346 × 326 mm rectangular spigots. Both use full DC motors on the supply and exhaust side, and both require a PVC condensate drain because of the air volume they move.

These sizes exist for spaces where ventilation load is set by occupancy rather than by floor area: restaurant floors, gyms, assembly halls, open-plan office floors and retail. In those spaces the duct run is long, the fittings are many, and the available static pressure decides whether the design airflow actually arrives at the diffuser. A unit rated at 2,000 m³/h with no pressure left is a 1,400 m³/h unit in practice.

Heat recovery at this scale is not a rounding error. At 2,000 m³/h with a 25 K temperature difference, the untreated ventilation load is around 16.8 kW; at the 83.4% low-speed efficiency of the 2,000 m³/h size, the residual load falls to about 2.8 kW. That difference is what separates a space that meets its ventilation requirement from a space that meets it and still keeps the plant size down.

Key Selling Points
  • 2,000 m³/h at 200 Pa — Rated with the static pressure still available, so the figure survives a real duct run.
  • 346 × 326 mm Rectangular Spigots — Matches rectangular trunk duct, which is what large commercial ceilings and plant rooms normally carry.
  • Full DC Motors on Both Sides — Supply and exhaust independently driven, three speeds as standard.
  • Temperature Efficiency 75.5% to 83.4% — 83.4% at low speed on the 2,000 m³/h size, 80.2% at low speed on the 1,500 m³/h size.
  • Low Speed at 41.5 and 42.5 dB(A) — Large air volume does not have to mean full speed operation all day.
  • PVC Drain Included in the Design — The drain requirement is stated up front rather than discovered at commissioning.
  • VRF Interlock and BMS Ready — PQE port for VRF interlock, GW-MOD(A) for Modbus, IMMP-BAC for BACnet.
  • 200 W at Low Speed on the 1,500 Size — Low speed is a usable duty point, not a token setting.
The Two Large Sizes
Item HRV-D1500(B) HRV-D2000(B)
Airflow (m³/h)1,5002,000
Input power H/M/L (W)680 / 320 / 200950 / 500 / 230
External static pressure (Pa)180200
Temperature efficiency H/M/L (%)75.5 / 78.6 / 80.277.2 / 79.5 / 83.4
Enthalpy efficiency H/M/L (%)69.4 / 71.2 / 74.874.7 / 77.0 / 80.6
Current (A)3.85.7
Sound pressure H/M/L dB(A) at 1.5 m51.5 / 46.5 / 41.553 / 48.5 / 42.5
Sound power (dB)6970
Dimensions L × W × H (mm)1740 × 1375 × 6151811 × 1575 × 685
Net / gross weight (kg)181.5 / 213208.5 / 245
Duct spigot346 × 326 mm346 × 326 mm
Rectangular Duct and Static Pressure

A 2,000 m³/h unit is only as good as the duct system attached to it. The 346 × 326 mm spigot carries roughly 0.48 m² of face area, so the trunk velocity at 2,000 m³/h sits near 1.2 m/s at the spigot itself — comfortable, and the reason the rectangular connection is worth using rather than reducing to round immediately.

The 200 Pa figure is the budget for everything downstream: duct, elbows, tees, silencers, fire dampers, grilles and the diffusers themselves. A restaurant floor with a long run and several branch take-offs will consume most of it. Two practical rules follow. First, calculate the pressure loss before fixing the model, not after. Second, if silencers are added for acoustic reasons, they consume static pressure too and the size may need to move up.

Where the calculated loss exceeds the available pressure, the answer is usually duct sizing rather than a bigger unit. Increasing the trunk from 346 × 326 to the next size up drops velocity and loss faster than moving to a larger model increases available pressure.

Drain and Casing Depth

Both large sizes require a PVC condensate drain. That is a design requirement, not an option: at these air volumes the moisture removed from the exhaust stream has to go somewhere, and the unit is normally installed in a plant room or a service bulkhead where a drain route exists.

The casing is 615 mm on the 1,500 m³/h size and 685 mm on the 2,000 m³/h size, with net weights of 181.5 and 208.5 kg. These are plant room or bulkhead units, not ceiling void units. Two people cannot lift them, the structure needs to be checked, and access for filter service has to be designed in from the start.

Efficiency at Large Airflow

Efficiency on this series falls as airflow rises, which is why the large sizes show lower figures than the residential ones. At 1,500 m³/h the temperature efficiency is 75.5% at high speed, 78.6% at medium and 80.2% at low. At 2,000 m³/h it is 77.2%, 79.5% and 83.4%.

The practical consequence is that the last 25% of airflow costs disproportionately. Where a space can be served at 1,500 m³/h instead of 2,000 m³/h, both the efficiency and the fan power improve. Where 2,000 m³/h is genuinely required, the low-speed figure of 83.4% is the one to use in the energy calculation, provided the design allows low-speed operation as the normal condition.

Where These Sizes Fit
  • Restaurant floors. Occupancy-driven load, odour extraction, long duct runs to the facade.
  • Gyms and fitness studios. High occupancy per square metre, sustained operation, humidity to manage.
  • Open-plan office floors. Large single zones where one unit serves a whole floor.
  • Assembly halls and training rooms. Intermittent high occupancy with a need for fast air change.
  • Retail floors. Continuous operation with a visible diffuser layout and an acoustic requirement.
  • Plant rooms serving several zones. One unit with a trunk duct and branch dampers, rather than several small units.
Installation Notes
  • Confirm the structure can carry 181.5 to 208.5 kg plus the duct load before fixing the position.
  • Plan the PVC drain route with a fall; do not leave it to the last trade.
  • Keep the 346 × 326 mm spigot as long as possible before any transition; avoid reducing at the unit.
  • Calculate external static pressure including silencers, dampers and grilles before selecting the model.
  • Provide service access on the filter side; the filter face on these sizes is large and needs room.
  • Use anti-vibration mounts; 208.5 kg of rotating equipment transmits into structure if mounted rigid.
  • Where the unit sits above an occupied space, specify duct silencers on both supply and return.
Technical Data
Model Airflow Input power (H/M/L) Temp. efficiency (H/M/L) Enthalpy efficiency (H/M/L) Current External static pressure Sound pressure (H/M/L)
HRV-D200(B)200 m³/h70/45/25 W79.5/81.1/83.5%75.0/77.5/79.6%0.64 A100 Pa33/29.5/25.5 dB(A)
HRV-D300(B)300 m³/h100/55/35 W75.5/78.8/82.5%72.1/75.0/79.3%0.84 A90 Pa36.5/33.5/30 dB(A)
HRV-D400(B)400 m³/h110/70/40 W77.7/79.0/81.3%73.5/75.3/78.0%0.97 A100 Pa36.5/32/28 dB(A)
HRV-D500(B)500 m³/h150/95/50 W80.6/82.2/85.5%74.0/76.6/80.5%1.2 A90 Pa36/30.5/24.5 dB(A)
HRV-D800(B)800 m³/h320/170/80 W78.7/82.1/86.8%72.3/75.4/79.0%2.4 A140 Pa42/39/34 dB(A)
HRV-D1000(B)1,000 m³/h380/210/100 W82.8/84.0/87.4%76.0/76.0/80.1%2.9 A160 Pa44/39/33.5 dB(A)
HRV-D1500(B)1,500 m³/h680/320/200 W75.5/78.6/80.2%69.4/71.2/74.8%3.8 A180 Pa51.5/46.5/41.5 dB(A)
HRV-D2000(B)2,000 m³/h950/500/230 W77.2/79.5/83.4%74.7/77.0/80.6%5.7 A200 Pa53/48.5/42.5 dB(A)

Notes: three fan speeds on all models; airflow and other single values are measured at high speed. Efficiency figures are measured with the standard G4 filter. The specification table is identical across all versions of this product page.

FAQ
Q1. What is the largest airflow available?

A: 2,000 m³/h on the HRV-D2000(B), rated against 200 Pa external static pressure.

Q2. Is the static pressure figure enough for a long duct run?

A: It depends on the run. 200 Pa has to cover duct, elbows, silencers, dampers and grilles. Calculate the loss first; where it exceeds the available pressure, increase the duct size before moving to a larger model.

Q3. Do these sizes need a drain?

A: Yes. Both the 1,500 and 2,000 m³/h sizes require a PVC condensate drain. The 200 to 1,000 m³/h sizes do not.

Q4. Can they be installed in a ceiling void?

A: Not normally. Casing depth is 615 mm and 685 mm with net weights of 181.5 and 208.5 kg. These are plant room or service bulkhead units, and the structure must be checked.

Q5. What duct connection is used?

A: 346 × 326 mm rectangular spigots on both sizes. Keep the rectangular section as long as possible before transitioning.

Q6. How efficient are they compared with the smaller sizes?

A: Lower at high speed, because efficiency falls as airflow rises. At low speed the 2,000 m³/h size reaches 83.4% temperature efficiency, which is comparable with the residential sizes.

Q7. Can one large unit replace several small ones?

A: Where the zones share a duct route and the same operating schedule, yes, and the duct loss becomes the deciding factor. Where zones need independent control or different schedules, separate units are usually the better answer.

Related Search Terms
  • large heat recovery ventilator
  • 2000 m³/h HRV
  • commercial ERV
  • restaurant ventilation with heat recovery
  • gym ventilation system
  • high airflow HRV
  • 346x326 duct HRV
Products
PRODUCTS DETAILS
Large Heat Recovery Ventilator 1500-2000 m³/h 200 Pa 2000 m³/h HRV Rectangular Duct Spigot and PVC Drain Choosing a Large HRV for Restaurants Gyms and Open Floors
Detail Information
Place of Origin
China
Brand Name
OEM;MIDEA
Certification
CB,ISO
Product Name:
Midea DC Series HRV
Airflow:
200 M³/h-2000 M³/h
Dimensions L X W X H:
1,195 X 801 X 272 Mm-1,811 X 1,575 X 685 Mm
Net / Gross Weight:
53.6 / 70.6 Kg-208.5 / 245 Kg
Spigot:
144 Mm-346 X 326 Mm
External Static Pressure:
100 Pa-200 Pa
Condensate Drain:
Not Required/PVC Required
Highlight

Large HRV 2000 m³/h

,

Rectangular Duct Spigot HRV

,

Large Heat Recovery Ventilator 200 Pa

Product Description
Product Overview

The two large sizes in the DC series deliver 1,500 and 2,000 m³/h against 180 and 200 Pa of external static pressure, through 346 × 326 mm rectangular spigots. Both use full DC motors on the supply and exhaust side, and both require a PVC condensate drain because of the air volume they move.

These sizes exist for spaces where ventilation load is set by occupancy rather than by floor area: restaurant floors, gyms, assembly halls, open-plan office floors and retail. In those spaces the duct run is long, the fittings are many, and the available static pressure decides whether the design airflow actually arrives at the diffuser. A unit rated at 2,000 m³/h with no pressure left is a 1,400 m³/h unit in practice.

Heat recovery at this scale is not a rounding error. At 2,000 m³/h with a 25 K temperature difference, the untreated ventilation load is around 16.8 kW; at the 83.4% low-speed efficiency of the 2,000 m³/h size, the residual load falls to about 2.8 kW. That difference is what separates a space that meets its ventilation requirement from a space that meets it and still keeps the plant size down.

Key Selling Points
  • 2,000 m³/h at 200 Pa — Rated with the static pressure still available, so the figure survives a real duct run.
  • 346 × 326 mm Rectangular Spigots — Matches rectangular trunk duct, which is what large commercial ceilings and plant rooms normally carry.
  • Full DC Motors on Both Sides — Supply and exhaust independently driven, three speeds as standard.
  • Temperature Efficiency 75.5% to 83.4% — 83.4% at low speed on the 2,000 m³/h size, 80.2% at low speed on the 1,500 m³/h size.
  • Low Speed at 41.5 and 42.5 dB(A) — Large air volume does not have to mean full speed operation all day.
  • PVC Drain Included in the Design — The drain requirement is stated up front rather than discovered at commissioning.
  • VRF Interlock and BMS Ready — PQE port for VRF interlock, GW-MOD(A) for Modbus, IMMP-BAC for BACnet.
  • 200 W at Low Speed on the 1,500 Size — Low speed is a usable duty point, not a token setting.
The Two Large Sizes
Item HRV-D1500(B) HRV-D2000(B)
Airflow (m³/h)1,5002,000
Input power H/M/L (W)680 / 320 / 200950 / 500 / 230
External static pressure (Pa)180200
Temperature efficiency H/M/L (%)75.5 / 78.6 / 80.277.2 / 79.5 / 83.4
Enthalpy efficiency H/M/L (%)69.4 / 71.2 / 74.874.7 / 77.0 / 80.6
Current (A)3.85.7
Sound pressure H/M/L dB(A) at 1.5 m51.5 / 46.5 / 41.553 / 48.5 / 42.5
Sound power (dB)6970
Dimensions L × W × H (mm)1740 × 1375 × 6151811 × 1575 × 685
Net / gross weight (kg)181.5 / 213208.5 / 245
Duct spigot346 × 326 mm346 × 326 mm
Rectangular Duct and Static Pressure

A 2,000 m³/h unit is only as good as the duct system attached to it. The 346 × 326 mm spigot carries roughly 0.48 m² of face area, so the trunk velocity at 2,000 m³/h sits near 1.2 m/s at the spigot itself — comfortable, and the reason the rectangular connection is worth using rather than reducing to round immediately.

The 200 Pa figure is the budget for everything downstream: duct, elbows, tees, silencers, fire dampers, grilles and the diffusers themselves. A restaurant floor with a long run and several branch take-offs will consume most of it. Two practical rules follow. First, calculate the pressure loss before fixing the model, not after. Second, if silencers are added for acoustic reasons, they consume static pressure too and the size may need to move up.

Where the calculated loss exceeds the available pressure, the answer is usually duct sizing rather than a bigger unit. Increasing the trunk from 346 × 326 to the next size up drops velocity and loss faster than moving to a larger model increases available pressure.

Drain and Casing Depth

Both large sizes require a PVC condensate drain. That is a design requirement, not an option: at these air volumes the moisture removed from the exhaust stream has to go somewhere, and the unit is normally installed in a plant room or a service bulkhead where a drain route exists.

The casing is 615 mm on the 1,500 m³/h size and 685 mm on the 2,000 m³/h size, with net weights of 181.5 and 208.5 kg. These are plant room or bulkhead units, not ceiling void units. Two people cannot lift them, the structure needs to be checked, and access for filter service has to be designed in from the start.

Efficiency at Large Airflow

Efficiency on this series falls as airflow rises, which is why the large sizes show lower figures than the residential ones. At 1,500 m³/h the temperature efficiency is 75.5% at high speed, 78.6% at medium and 80.2% at low. At 2,000 m³/h it is 77.2%, 79.5% and 83.4%.

The practical consequence is that the last 25% of airflow costs disproportionately. Where a space can be served at 1,500 m³/h instead of 2,000 m³/h, both the efficiency and the fan power improve. Where 2,000 m³/h is genuinely required, the low-speed figure of 83.4% is the one to use in the energy calculation, provided the design allows low-speed operation as the normal condition.

Where These Sizes Fit
  • Restaurant floors. Occupancy-driven load, odour extraction, long duct runs to the facade.
  • Gyms and fitness studios. High occupancy per square metre, sustained operation, humidity to manage.
  • Open-plan office floors. Large single zones where one unit serves a whole floor.
  • Assembly halls and training rooms. Intermittent high occupancy with a need for fast air change.
  • Retail floors. Continuous operation with a visible diffuser layout and an acoustic requirement.
  • Plant rooms serving several zones. One unit with a trunk duct and branch dampers, rather than several small units.
Installation Notes
  • Confirm the structure can carry 181.5 to 208.5 kg plus the duct load before fixing the position.
  • Plan the PVC drain route with a fall; do not leave it to the last trade.
  • Keep the 346 × 326 mm spigot as long as possible before any transition; avoid reducing at the unit.
  • Calculate external static pressure including silencers, dampers and grilles before selecting the model.
  • Provide service access on the filter side; the filter face on these sizes is large and needs room.
  • Use anti-vibration mounts; 208.5 kg of rotating equipment transmits into structure if mounted rigid.
  • Where the unit sits above an occupied space, specify duct silencers on both supply and return.
Technical Data
Model Airflow Input power (H/M/L) Temp. efficiency (H/M/L) Enthalpy efficiency (H/M/L) Current External static pressure Sound pressure (H/M/L)
HRV-D200(B)200 m³/h70/45/25 W79.5/81.1/83.5%75.0/77.5/79.6%0.64 A100 Pa33/29.5/25.5 dB(A)
HRV-D300(B)300 m³/h100/55/35 W75.5/78.8/82.5%72.1/75.0/79.3%0.84 A90 Pa36.5/33.5/30 dB(A)
HRV-D400(B)400 m³/h110/70/40 W77.7/79.0/81.3%73.5/75.3/78.0%0.97 A100 Pa36.5/32/28 dB(A)
HRV-D500(B)500 m³/h150/95/50 W80.6/82.2/85.5%74.0/76.6/80.5%1.2 A90 Pa36/30.5/24.5 dB(A)
HRV-D800(B)800 m³/h320/170/80 W78.7/82.1/86.8%72.3/75.4/79.0%2.4 A140 Pa42/39/34 dB(A)
HRV-D1000(B)1,000 m³/h380/210/100 W82.8/84.0/87.4%76.0/76.0/80.1%2.9 A160 Pa44/39/33.5 dB(A)
HRV-D1500(B)1,500 m³/h680/320/200 W75.5/78.6/80.2%69.4/71.2/74.8%3.8 A180 Pa51.5/46.5/41.5 dB(A)
HRV-D2000(B)2,000 m³/h950/500/230 W77.2/79.5/83.4%74.7/77.0/80.6%5.7 A200 Pa53/48.5/42.5 dB(A)

Notes: three fan speeds on all models; airflow and other single values are measured at high speed. Efficiency figures are measured with the standard G4 filter. The specification table is identical across all versions of this product page.

FAQ
Q1. What is the largest airflow available?

A: 2,000 m³/h on the HRV-D2000(B), rated against 200 Pa external static pressure.

Q2. Is the static pressure figure enough for a long duct run?

A: It depends on the run. 200 Pa has to cover duct, elbows, silencers, dampers and grilles. Calculate the loss first; where it exceeds the available pressure, increase the duct size before moving to a larger model.

Q3. Do these sizes need a drain?

A: Yes. Both the 1,500 and 2,000 m³/h sizes require a PVC condensate drain. The 200 to 1,000 m³/h sizes do not.

Q4. Can they be installed in a ceiling void?

A: Not normally. Casing depth is 615 mm and 685 mm with net weights of 181.5 and 208.5 kg. These are plant room or service bulkhead units, and the structure must be checked.

Q5. What duct connection is used?

A: 346 × 326 mm rectangular spigots on both sizes. Keep the rectangular section as long as possible before transitioning.

Q6. How efficient are they compared with the smaller sizes?

A: Lower at high speed, because efficiency falls as airflow rises. At low speed the 2,000 m³/h size reaches 83.4% temperature efficiency, which is comparable with the residential sizes.

Q7. Can one large unit replace several small ones?

A: Where the zones share a duct route and the same operating schedule, yes, and the duct loss becomes the deciding factor. Where zones need independent control or different schedules, separate units are usually the better answer.

Related Search Terms
  • large heat recovery ventilator
  • 2000 m³/h HRV
  • commercial ERV
  • restaurant ventilation with heat recovery
  • gym ventilation system
  • high airflow HRV
  • 346x326 duct HRV
Sitemap |  Privacy Policy | China Good Quality DC Inverter VRF Supplier. Copyright © 2024-2026 Henan Hongtai HVAC Equipment Co., Ltd. . All Rights Reserved.
+86 18703827920