The DC series residential range covers 200, 300 and 400 m³/h airflow within a uniform 272 mm casing. All three sizes operate without a condensate drain, because the paper heat exchange core transfers moisture in the vapour phase rather than condensing it out. In a flat or a villa, that single detail decides whether the installation fits the ceiling void at all.
A drain pipe needs a fall, a route to a stack or to the outside, and a discharge point where nobody will complain about the drip. In a finished apartment with a 300 mm ceiling void and neighbours above, that route often does not exist. Removing the drain removes the trade that has to be coordinated, the trap that can dry out, and the leak that appears two years later.
The three sizes are driven by full DC motors on both air streams, run from a wired controller with four fan speeds, and reach 25.5 dB(A) at low speed on the smallest size. Airflow from 200 to 400 m³/h covers a bedroom, a suite, an apartment or a villa floor, and two or more units can be controlled from one controller where a larger home needs zoned ventilation.
A bedroom or a small suite normally falls in the 200 to 300 m³/h band. A full apartment, a living area with several rooms, or a villa floor normally falls in the 300 to 400 m³/h band. Where a home is large enough to need two or three units, zoning by floor or by wing keeps duct runs short, which matters more for pressure loss than the unit selection does.
Sizing follows the project ventilation calculation. The table below is a reference for early-stage discussions, not a substitute for that calculation.
| Space | Typical Airflow Reference | Recommended Size | Low Speed dB(A) |
|---|---|---|---|
| Bedroom, study | 60–120 m³/h | D200 | 25.5 |
| Hotel-style suite, small apartment | 150–250 m³/h | D200, D300 | 25.5 / 30 |
| Apartment, 2 to 3 bedrooms | 250–350 m³/h | D300, D400 | 30 / 28 |
| Villa floor, open living area | 350–400 m³/h | D400 | 28 |
A condensing unit produces water. Where that water goes is a design problem, and in a finished apartment it is often the problem that delays handover. The residential sizes avoid it entirely: the core transfers latent heat as vapour, so there is no condensate to remove under normal residential conditions.
Two boundaries are worth stating plainly. First, the drain-free design applies to the 200 to 1,000 m³/h sizes; the 1,500 and 2,000 m³/h sizes do require a PVC drain. Second, in a space with sustained high humidity and a large temperature difference, condensate can still form in the ductwork rather than in the unit, so ducts passing through unconditioned space should be insulated regardless of the unit type.
| Model | Dimensions L × W × H (mm) | Net / Gross Weight (kg) | Duct Spigot |
|---|---|---|---|
| HRV-D200(B) | 1195 × 801 × 272 | 53.6 / 70.6 | Φ144 × 2 |
| HRV-D300(B) | 1195 × 914 × 272 | 59 / 77 | Φ144 × 2 |
| HRV-D400(B) | 1276 × 1204 × 272 | 71.5 / 91.5 | Φ198 × 2 |
The 272 mm depth is the figure that decides feasibility in a residential ceiling. A 300 mm void leaves 28 mm for hangers and tolerance, so the mounting method has to be chosen before the unit is ordered, not after. Where the void is shallower than 272 mm plus clearance, the next option is a bulkhead or a plant cupboard rather than a different model.
Single-phase 220–240 V, 50 Hz as standard; 60 Hz and other voltages available to order. Current draw is 0.64 A on the 200 m³/h size, 0.84 A on the 300 m³/h and 0.97 A on the 400 m³/h size, so a residential circuit is normally sufficient.
The KJR-27B/E wired controller provides five operating modes and four fan speeds including a sleep setting, and manages up to 16 units. The WDC-120G/WK(A) controller adds CO2 display, filter indication, group control and weekly timing where a homeowner wants demand-controlled ventilation. A CO2 sensor box is available as an option for the demand-control function.
| Model | Airflow | Input Power (H/M/L) | Temp. Efficiency (H/M/L) | Enthalpy Efficiency (H/M/L) | Current | External Static Pressure | Sound Pressure (H/M/L) |
|---|---|---|---|---|---|---|---|
| HRV-D200(B) | 200 m³/h | 70/45/25 W | 79.5/81.1/83.5% | 75.0/77.5/79.6% | 0.64 A | 100 Pa | 33/29.5/25.5 dB(A) |
| HRV-D300(B) | 300 m³/h | 100/55/35 W | 75.5/78.8/82.5% | 72.1/75.0/79.3% | 0.84 A | 90 Pa | 36.5/33.5/30 dB(A) |
| HRV-D400(B) | 400 m³/h | 110/70/40 W | 77.7/79.0/81.3% | 73.5/75.3/78.0% | 0.97 A | 100 Pa | 36.5/32/28 dB(A) |
| HRV-D500(B) | 500 m³/h | 150/95/50 W | 80.6/82.2/85.5% | 74.0/76.6/80.5% | 1.2 A | 90 Pa | 36/30.5/24.5 dB(A) |
| HRV-D800(B) | 800 m³/h | 320/170/80 W | 78.7/82.1/86.8% | 72.3/75.4/79.0% | 2.4 A | 140 Pa | 42/39/34 dB(A) |
| HRV-D1000(B) | 1,000 m³/h | 380/210/100 W | 82.8/84.0/87.4% | 76.0/76.0/80.1% | 2.9 A | 160 Pa | 44/39/33.5 dB(A) |
| HRV-D1500(B) | 1,500 m³/h | 680/320/200 W | 75.5/78.6/80.2% | 69.4/71.2/74.8% | 3.8 A | 180 Pa | 51.5/46.5/41.5 dB(A) |
| HRV-D2000(B) | 2,000 m³/h | 950/500/230 W | 77.2/79.5/83.4% | 74.7/77.0/80.6% | 5.7 A | 200 Pa | 53/48.5/42.5 dB(A) |
Notes: three fan speeds on all models; airflow and other single values are measured at high speed. Residential duties normally fall within the first three sizes; the full range is listed to keep the specification table identical across all versions of this product page. Efficiency figures are measured with the standard G4 filter.
The 200 to 1,000 m³/h sizes do not require a condensate drain under normal operating conditions. The 1,500 and 2,000 m³/h sizes do require a PVC drain. Where a space runs at sustained high humidity with a large temperature difference, insulate ducts passing through unconditioned space.
272 mm plus hanger clearance, so a 300 mm void is the practical minimum. Confirm the mounting method before ordering.
Normally 300 to 400 m³/h, subject to the ventilation calculation. A single bedroom or suite normally falls at 200 to 300 m³/h.
Yes. The KJR-27B/E controller manages up to 16 units, and the WDC-120G/WK(A) adds group control where floors or wings are operated separately.
No, it is optional. With the CO2 sensor box and the WDC controller, fan speed follows measured CO2 across four thresholds.
Temperature efficiency is 75.5% to 83.5% depending on model and speed, with enthalpy efficiency of 72.1% to 79.6%. The paper core transfers latent heat as well, which matters in winter when indoor air is drier.
Filter cleaning at the interval indicated by the controller, vacuuming of the core approximately every two years, and a fan inspection every six months. The core must never be washed with water.
The DC series residential range covers 200, 300 and 400 m³/h airflow within a uniform 272 mm casing. All three sizes operate without a condensate drain, because the paper heat exchange core transfers moisture in the vapour phase rather than condensing it out. In a flat or a villa, that single detail decides whether the installation fits the ceiling void at all.
A drain pipe needs a fall, a route to a stack or to the outside, and a discharge point where nobody will complain about the drip. In a finished apartment with a 300 mm ceiling void and neighbours above, that route often does not exist. Removing the drain removes the trade that has to be coordinated, the trap that can dry out, and the leak that appears two years later.
The three sizes are driven by full DC motors on both air streams, run from a wired controller with four fan speeds, and reach 25.5 dB(A) at low speed on the smallest size. Airflow from 200 to 400 m³/h covers a bedroom, a suite, an apartment or a villa floor, and two or more units can be controlled from one controller where a larger home needs zoned ventilation.
A bedroom or a small suite normally falls in the 200 to 300 m³/h band. A full apartment, a living area with several rooms, or a villa floor normally falls in the 300 to 400 m³/h band. Where a home is large enough to need two or three units, zoning by floor or by wing keeps duct runs short, which matters more for pressure loss than the unit selection does.
Sizing follows the project ventilation calculation. The table below is a reference for early-stage discussions, not a substitute for that calculation.
| Space | Typical Airflow Reference | Recommended Size | Low Speed dB(A) |
|---|---|---|---|
| Bedroom, study | 60–120 m³/h | D200 | 25.5 |
| Hotel-style suite, small apartment | 150–250 m³/h | D200, D300 | 25.5 / 30 |
| Apartment, 2 to 3 bedrooms | 250–350 m³/h | D300, D400 | 30 / 28 |
| Villa floor, open living area | 350–400 m³/h | D400 | 28 |
A condensing unit produces water. Where that water goes is a design problem, and in a finished apartment it is often the problem that delays handover. The residential sizes avoid it entirely: the core transfers latent heat as vapour, so there is no condensate to remove under normal residential conditions.
Two boundaries are worth stating plainly. First, the drain-free design applies to the 200 to 1,000 m³/h sizes; the 1,500 and 2,000 m³/h sizes do require a PVC drain. Second, in a space with sustained high humidity and a large temperature difference, condensate can still form in the ductwork rather than in the unit, so ducts passing through unconditioned space should be insulated regardless of the unit type.
| Model | Dimensions L × W × H (mm) | Net / Gross Weight (kg) | Duct Spigot |
|---|---|---|---|
| HRV-D200(B) | 1195 × 801 × 272 | 53.6 / 70.6 | Φ144 × 2 |
| HRV-D300(B) | 1195 × 914 × 272 | 59 / 77 | Φ144 × 2 |
| HRV-D400(B) | 1276 × 1204 × 272 | 71.5 / 91.5 | Φ198 × 2 |
The 272 mm depth is the figure that decides feasibility in a residential ceiling. A 300 mm void leaves 28 mm for hangers and tolerance, so the mounting method has to be chosen before the unit is ordered, not after. Where the void is shallower than 272 mm plus clearance, the next option is a bulkhead or a plant cupboard rather than a different model.
Single-phase 220–240 V, 50 Hz as standard; 60 Hz and other voltages available to order. Current draw is 0.64 A on the 200 m³/h size, 0.84 A on the 300 m³/h and 0.97 A on the 400 m³/h size, so a residential circuit is normally sufficient.
The KJR-27B/E wired controller provides five operating modes and four fan speeds including a sleep setting, and manages up to 16 units. The WDC-120G/WK(A) controller adds CO2 display, filter indication, group control and weekly timing where a homeowner wants demand-controlled ventilation. A CO2 sensor box is available as an option for the demand-control function.
| Model | Airflow | Input Power (H/M/L) | Temp. Efficiency (H/M/L) | Enthalpy Efficiency (H/M/L) | Current | External Static Pressure | Sound Pressure (H/M/L) |
|---|---|---|---|---|---|---|---|
| HRV-D200(B) | 200 m³/h | 70/45/25 W | 79.5/81.1/83.5% | 75.0/77.5/79.6% | 0.64 A | 100 Pa | 33/29.5/25.5 dB(A) |
| HRV-D300(B) | 300 m³/h | 100/55/35 W | 75.5/78.8/82.5% | 72.1/75.0/79.3% | 0.84 A | 90 Pa | 36.5/33.5/30 dB(A) |
| HRV-D400(B) | 400 m³/h | 110/70/40 W | 77.7/79.0/81.3% | 73.5/75.3/78.0% | 0.97 A | 100 Pa | 36.5/32/28 dB(A) |
| HRV-D500(B) | 500 m³/h | 150/95/50 W | 80.6/82.2/85.5% | 74.0/76.6/80.5% | 1.2 A | 90 Pa | 36/30.5/24.5 dB(A) |
| HRV-D800(B) | 800 m³/h | 320/170/80 W | 78.7/82.1/86.8% | 72.3/75.4/79.0% | 2.4 A | 140 Pa | 42/39/34 dB(A) |
| HRV-D1000(B) | 1,000 m³/h | 380/210/100 W | 82.8/84.0/87.4% | 76.0/76.0/80.1% | 2.9 A | 160 Pa | 44/39/33.5 dB(A) |
| HRV-D1500(B) | 1,500 m³/h | 680/320/200 W | 75.5/78.6/80.2% | 69.4/71.2/74.8% | 3.8 A | 180 Pa | 51.5/46.5/41.5 dB(A) |
| HRV-D2000(B) | 2,000 m³/h | 950/500/230 W | 77.2/79.5/83.4% | 74.7/77.0/80.6% | 5.7 A | 200 Pa | 53/48.5/42.5 dB(A) |
Notes: three fan speeds on all models; airflow and other single values are measured at high speed. Residential duties normally fall within the first three sizes; the full range is listed to keep the specification table identical across all versions of this product page. Efficiency figures are measured with the standard G4 filter.
The 200 to 1,000 m³/h sizes do not require a condensate drain under normal operating conditions. The 1,500 and 2,000 m³/h sizes do require a PVC drain. Where a space runs at sustained high humidity with a large temperature difference, insulate ducts passing through unconditioned space.
272 mm plus hanger clearance, so a 300 mm void is the practical minimum. Confirm the mounting method before ordering.
Normally 300 to 400 m³/h, subject to the ventilation calculation. A single bedroom or suite normally falls at 200 to 300 m³/h.
Yes. The KJR-27B/E controller manages up to 16 units, and the WDC-120G/WK(A) adds group control where floors or wings are operated separately.
No, it is optional. With the CO2 sensor box and the WDC controller, fan speed follows measured CO2 across four thresholds.
Temperature efficiency is 75.5% to 83.5% depending on model and speed, with enthalpy efficiency of 72.1% to 79.6%. The paper core transfers latent heat as well, which matters in winter when indoor air is drier.
Filter cleaning at the interval indicated by the controller, vacuuming of the core approximately every two years, and a fan inspection every six months. The core must never be washed with water.