logo
Products
PRODUCTS DETAILS
Home > Products >
Residential Heat Recovery Ventilator 200 400 272 mm Slim Apartment HRV Without Drain Pipe for 300 mm Ceiling Voids Villa Ventilation System with Heat Recovery and CO2 Control

Residential Heat Recovery Ventilator 200 400 272 mm Slim Apartment HRV Without Drain Pipe for 300 mm Ceiling Voids Villa Ventilation System with Heat Recovery and CO2 Control

Detail Information
Place of Origin
China
Brand Name
OEM;MIDEA
Certification
CB,ISO
Product Name:
Midea DC Series HRV
Airflow:
200 M³/h-2000 M³/h
Dimensions L X W X H:
1,195 X 801 X 272 Mm-1,811 X 1,575 X 685 Mm
Net / Gross Weight:
53.6 / 70.6 Kg-208.5 / 245 Kg
Spigot:
144 Mm-346 X 326 Mm
External Static Pressure:
100 Pa-200 Pa
Condensate Drain:
Not Required/PVC Required
Highlight:

slim apartment HRV ventilator

,

drainless ceiling HRV system

,

villa heat recovery ventilator

Product Description
Product Overview: Slim 272 mm Residential Heat Recovery Ventilator

The DC series residential range covers 200, 300 and 400 m³/h airflow within a uniform 272 mm casing. All three sizes operate without a condensate drain, because the paper heat exchange core transfers moisture in the vapour phase rather than condensing it out. In a flat or a villa, that single detail decides whether the installation fits the ceiling void at all.

A drain pipe needs a fall, a route to a stack or to the outside, and a discharge point where nobody will complain about the drip. In a finished apartment with a 300 mm ceiling void and neighbours above, that route often does not exist. Removing the drain removes the trade that has to be coordinated, the trap that can dry out, and the leak that appears two years later.

The three sizes are driven by full DC motors on both air streams, run from a wired controller with four fan speeds, and reach 25.5 dB(A) at low speed on the smallest size. Airflow from 200 to 400 m³/h covers a bedroom, a suite, an apartment or a villa floor, and two or more units can be controlled from one controller where a larger home needs zoned ventilation.

Key Selling Points
  • 272 mm Casing on All Three Sizes — Fits a 300 mm ceiling void with room for the hangers, the insulation and the duct connection.
  • No Condensate Drain — No fall, no trap, no route to a stack; the installation stops competing with the plumbing trade.
  • 25.5 dB(A) at Low Speed — On the 200 m³/h size at 1.5 m; 30 dB(A) on the 300 m³/h and 28 dB(A) on the 400 m³/h size.
  • Temperature Efficiency up to 83.5% — 83.5% on the 200 m³/h size at low speed, 82.5% on the 300 m³/h and 81.3% on the 400 m³/h size.
  • Single-Phase 220–240 V — Standard domestic supply, no three-phase connection in a residential riser.
  • 25 W at Low Speed — The smallest size draws 25 W at low speed, a running cost a homeowner will accept.
  • Paper Heat Exchange Core — Moisture transfers in the vapour phase; no rotating wheel, no cross-contamination between exhaust and supply.
  • Zoned Control — KJR-27B/E wired controller manages up to 16 units, so a villa can run one unit per floor from one point.
Why Three Sizes Cover Most Homes

A bedroom or a small suite normally falls in the 200 to 300 m³/h band. A full apartment, a living area with several rooms, or a villa floor normally falls in the 300 to 400 m³/h band. Where a home is large enough to need two or three units, zoning by floor or by wing keeps duct runs short, which matters more for pressure loss than the unit selection does.

Sizing follows the project ventilation calculation. The table below is a reference for early-stage discussions, not a substitute for that calculation.

Space Typical Airflow Reference Recommended Size Low Speed dB(A)
Bedroom, study 60–120 m³/h D200 25.5
Hotel-style suite, small apartment 150–250 m³/h D200, D300 25.5 / 30
Apartment, 2 to 3 bedrooms 250–350 m³/h D300, D400 30 / 28
Villa floor, open living area 350–400 m³/h D400 28
No Drain Pipe: What It Changes in a Flat

A condensing unit produces water. Where that water goes is a design problem, and in a finished apartment it is often the problem that delays handover. The residential sizes avoid it entirely: the core transfers latent heat as vapour, so there is no condensate to remove under normal residential conditions.

Two boundaries are worth stating plainly. First, the drain-free design applies to the 200 to 1,000 m³/h sizes; the 1,500 and 2,000 m³/h sizes do require a PVC drain. Second, in a space with sustained high humidity and a large temperature difference, condensate can still form in the ductwork rather than in the unit, so ducts passing through unconditioned space should be insulated regardless of the unit type.

Casing Depth and Where It Fits
Model Dimensions L × W × H (mm) Net / Gross Weight (kg) Duct Spigot
HRV-D200(B) 1195 × 801 × 272 53.6 / 70.6 Φ144 × 2
HRV-D300(B) 1195 × 914 × 272 59 / 77 Φ144 × 2
HRV-D400(B) 1276 × 1204 × 272 71.5 / 91.5 Φ198 × 2

The 272 mm depth is the figure that decides feasibility in a residential ceiling. A 300 mm void leaves 28 mm for hangers and tolerance, so the mounting method has to be chosen before the unit is ordered, not after. Where the void is shallower than 272 mm plus clearance, the next option is a bulkhead or a plant cupboard rather than a different model.

Electrical and Control

Single-phase 220–240 V, 50 Hz as standard; 60 Hz and other voltages available to order. Current draw is 0.64 A on the 200 m³/h size, 0.84 A on the 300 m³/h and 0.97 A on the 400 m³/h size, so a residential circuit is normally sufficient.

The KJR-27B/E wired controller provides five operating modes and four fan speeds including a sleep setting, and manages up to 16 units. The WDC-120G/WK(A) controller adds CO2 display, filter indication, group control and weekly timing where a homeowner wants demand-controlled ventilation. A CO2 sensor box is available as an option for the demand-control function.

Installation in a Flat
  • Confirm the ceiling void depth before ordering; 272 mm plus hanger clearance is the minimum.
  • Mount on anti-vibration hangers, not on the ceiling grid, so the unit does not excite the plasterboard.
  • Use flexible connectors on all four ports; residential duct runs are short and transmit noise easily.
  • Keep at least one duct diameter of straight run at each spigot where the void allows.
  • Insulate ducts passing through unconditioned space to avoid surface condensation.
  • Terminate supply and exhaust on opposite facades where possible, and keep the two terminals apart.
  • Leave a service access panel at the filter side; filter cleaning is the only routine maintenance.
Technical Data
Model Airflow Input Power (H/M/L) Temp. Efficiency (H/M/L) Enthalpy Efficiency (H/M/L) Current External Static Pressure Sound Pressure (H/M/L)
HRV-D200(B) 200 m³/h 70/45/25 W 79.5/81.1/83.5% 75.0/77.5/79.6% 0.64 A 100 Pa 33/29.5/25.5 dB(A)
HRV-D300(B) 300 m³/h 100/55/35 W 75.5/78.8/82.5% 72.1/75.0/79.3% 0.84 A 90 Pa 36.5/33.5/30 dB(A)
HRV-D400(B) 400 m³/h 110/70/40 W 77.7/79.0/81.3% 73.5/75.3/78.0% 0.97 A 100 Pa 36.5/32/28 dB(A)
HRV-D500(B) 500 m³/h 150/95/50 W 80.6/82.2/85.5% 74.0/76.6/80.5% 1.2 A 90 Pa 36/30.5/24.5 dB(A)
HRV-D800(B) 800 m³/h 320/170/80 W 78.7/82.1/86.8% 72.3/75.4/79.0% 2.4 A 140 Pa 42/39/34 dB(A)
HRV-D1000(B) 1,000 m³/h 380/210/100 W 82.8/84.0/87.4% 76.0/76.0/80.1% 2.9 A 160 Pa 44/39/33.5 dB(A)
HRV-D1500(B) 1,500 m³/h 680/320/200 W 75.5/78.6/80.2% 69.4/71.2/74.8% 3.8 A 180 Pa 51.5/46.5/41.5 dB(A)
HRV-D2000(B) 2,000 m³/h 950/500/230 W 77.2/79.5/83.4% 74.7/77.0/80.6% 5.7 A 200 Pa 53/48.5/42.5 dB(A)

Notes: three fan speeds on all models; airflow and other single values are measured at high speed. Residential duties normally fall within the first three sizes; the full range is listed to keep the specification table identical across all versions of this product page. Efficiency figures are measured with the standard G4 filter.

Frequently Asked Questions
Q1. Does the residential HRV really need no drain?

The 200 to 1,000 m³/h sizes do not require a condensate drain under normal operating conditions. The 1,500 and 2,000 m³/h sizes do require a PVC drain. Where a space runs at sustained high humidity with a large temperature difference, insulate ducts passing through unconditioned space.

Q2. What ceiling depth do I need?

272 mm plus hanger clearance, so a 300 mm void is the practical minimum. Confirm the mounting method before ordering.

Q3. Which size for a two-bedroom apartment?

Normally 300 to 400 m³/h, subject to the ventilation calculation. A single bedroom or suite normally falls at 200 to 300 m³/h.

Q4. Can one controller run several units in a villa?

Yes. The KJR-27B/E controller manages up to 16 units, and the WDC-120G/WK(A) adds group control where floors or wings are operated separately.

Q5. Is a CO2 sensor included?

No, it is optional. With the CO2 sensor box and the WDC controller, fan speed follows measured CO2 across four thresholds.

Q6. How efficient is it in a cold climate?

Temperature efficiency is 75.5% to 83.5% depending on model and speed, with enthalpy efficiency of 72.1% to 79.6%. The paper core transfers latent heat as well, which matters in winter when indoor air is drier.

Q7. What maintenance does it need?

Filter cleaning at the interval indicated by the controller, vacuuming of the core approximately every two years, and a fan inspection every six months. The core must never be washed with water.

Product Gallery
Related Search Terms
residential heat recovery ventilator home HRV apartment ventilation system villa fresh air system HRV without drain slim ceiling HRV home ERV 272 mm HRV
Products
PRODUCTS DETAILS
Residential Heat Recovery Ventilator 200 400 272 mm Slim Apartment HRV Without Drain Pipe for 300 mm Ceiling Voids Villa Ventilation System with Heat Recovery and CO2 Control
Detail Information
Place of Origin
China
Brand Name
OEM;MIDEA
Certification
CB,ISO
Product Name:
Midea DC Series HRV
Airflow:
200 M³/h-2000 M³/h
Dimensions L X W X H:
1,195 X 801 X 272 Mm-1,811 X 1,575 X 685 Mm
Net / Gross Weight:
53.6 / 70.6 Kg-208.5 / 245 Kg
Spigot:
144 Mm-346 X 326 Mm
External Static Pressure:
100 Pa-200 Pa
Condensate Drain:
Not Required/PVC Required
Highlight

slim apartment HRV ventilator

,

drainless ceiling HRV system

,

villa heat recovery ventilator

Product Description
Product Overview: Slim 272 mm Residential Heat Recovery Ventilator

The DC series residential range covers 200, 300 and 400 m³/h airflow within a uniform 272 mm casing. All three sizes operate without a condensate drain, because the paper heat exchange core transfers moisture in the vapour phase rather than condensing it out. In a flat or a villa, that single detail decides whether the installation fits the ceiling void at all.

A drain pipe needs a fall, a route to a stack or to the outside, and a discharge point where nobody will complain about the drip. In a finished apartment with a 300 mm ceiling void and neighbours above, that route often does not exist. Removing the drain removes the trade that has to be coordinated, the trap that can dry out, and the leak that appears two years later.

The three sizes are driven by full DC motors on both air streams, run from a wired controller with four fan speeds, and reach 25.5 dB(A) at low speed on the smallest size. Airflow from 200 to 400 m³/h covers a bedroom, a suite, an apartment or a villa floor, and two or more units can be controlled from one controller where a larger home needs zoned ventilation.

Key Selling Points
  • 272 mm Casing on All Three Sizes — Fits a 300 mm ceiling void with room for the hangers, the insulation and the duct connection.
  • No Condensate Drain — No fall, no trap, no route to a stack; the installation stops competing with the plumbing trade.
  • 25.5 dB(A) at Low Speed — On the 200 m³/h size at 1.5 m; 30 dB(A) on the 300 m³/h and 28 dB(A) on the 400 m³/h size.
  • Temperature Efficiency up to 83.5% — 83.5% on the 200 m³/h size at low speed, 82.5% on the 300 m³/h and 81.3% on the 400 m³/h size.
  • Single-Phase 220–240 V — Standard domestic supply, no three-phase connection in a residential riser.
  • 25 W at Low Speed — The smallest size draws 25 W at low speed, a running cost a homeowner will accept.
  • Paper Heat Exchange Core — Moisture transfers in the vapour phase; no rotating wheel, no cross-contamination between exhaust and supply.
  • Zoned Control — KJR-27B/E wired controller manages up to 16 units, so a villa can run one unit per floor from one point.
Why Three Sizes Cover Most Homes

A bedroom or a small suite normally falls in the 200 to 300 m³/h band. A full apartment, a living area with several rooms, or a villa floor normally falls in the 300 to 400 m³/h band. Where a home is large enough to need two or three units, zoning by floor or by wing keeps duct runs short, which matters more for pressure loss than the unit selection does.

Sizing follows the project ventilation calculation. The table below is a reference for early-stage discussions, not a substitute for that calculation.

Space Typical Airflow Reference Recommended Size Low Speed dB(A)
Bedroom, study 60–120 m³/h D200 25.5
Hotel-style suite, small apartment 150–250 m³/h D200, D300 25.5 / 30
Apartment, 2 to 3 bedrooms 250–350 m³/h D300, D400 30 / 28
Villa floor, open living area 350–400 m³/h D400 28
No Drain Pipe: What It Changes in a Flat

A condensing unit produces water. Where that water goes is a design problem, and in a finished apartment it is often the problem that delays handover. The residential sizes avoid it entirely: the core transfers latent heat as vapour, so there is no condensate to remove under normal residential conditions.

Two boundaries are worth stating plainly. First, the drain-free design applies to the 200 to 1,000 m³/h sizes; the 1,500 and 2,000 m³/h sizes do require a PVC drain. Second, in a space with sustained high humidity and a large temperature difference, condensate can still form in the ductwork rather than in the unit, so ducts passing through unconditioned space should be insulated regardless of the unit type.

Casing Depth and Where It Fits
Model Dimensions L × W × H (mm) Net / Gross Weight (kg) Duct Spigot
HRV-D200(B) 1195 × 801 × 272 53.6 / 70.6 Φ144 × 2
HRV-D300(B) 1195 × 914 × 272 59 / 77 Φ144 × 2
HRV-D400(B) 1276 × 1204 × 272 71.5 / 91.5 Φ198 × 2

The 272 mm depth is the figure that decides feasibility in a residential ceiling. A 300 mm void leaves 28 mm for hangers and tolerance, so the mounting method has to be chosen before the unit is ordered, not after. Where the void is shallower than 272 mm plus clearance, the next option is a bulkhead or a plant cupboard rather than a different model.

Electrical and Control

Single-phase 220–240 V, 50 Hz as standard; 60 Hz and other voltages available to order. Current draw is 0.64 A on the 200 m³/h size, 0.84 A on the 300 m³/h and 0.97 A on the 400 m³/h size, so a residential circuit is normally sufficient.

The KJR-27B/E wired controller provides five operating modes and four fan speeds including a sleep setting, and manages up to 16 units. The WDC-120G/WK(A) controller adds CO2 display, filter indication, group control and weekly timing where a homeowner wants demand-controlled ventilation. A CO2 sensor box is available as an option for the demand-control function.

Installation in a Flat
  • Confirm the ceiling void depth before ordering; 272 mm plus hanger clearance is the minimum.
  • Mount on anti-vibration hangers, not on the ceiling grid, so the unit does not excite the plasterboard.
  • Use flexible connectors on all four ports; residential duct runs are short and transmit noise easily.
  • Keep at least one duct diameter of straight run at each spigot where the void allows.
  • Insulate ducts passing through unconditioned space to avoid surface condensation.
  • Terminate supply and exhaust on opposite facades where possible, and keep the two terminals apart.
  • Leave a service access panel at the filter side; filter cleaning is the only routine maintenance.
Technical Data
Model Airflow Input Power (H/M/L) Temp. Efficiency (H/M/L) Enthalpy Efficiency (H/M/L) Current External Static Pressure Sound Pressure (H/M/L)
HRV-D200(B) 200 m³/h 70/45/25 W 79.5/81.1/83.5% 75.0/77.5/79.6% 0.64 A 100 Pa 33/29.5/25.5 dB(A)
HRV-D300(B) 300 m³/h 100/55/35 W 75.5/78.8/82.5% 72.1/75.0/79.3% 0.84 A 90 Pa 36.5/33.5/30 dB(A)
HRV-D400(B) 400 m³/h 110/70/40 W 77.7/79.0/81.3% 73.5/75.3/78.0% 0.97 A 100 Pa 36.5/32/28 dB(A)
HRV-D500(B) 500 m³/h 150/95/50 W 80.6/82.2/85.5% 74.0/76.6/80.5% 1.2 A 90 Pa 36/30.5/24.5 dB(A)
HRV-D800(B) 800 m³/h 320/170/80 W 78.7/82.1/86.8% 72.3/75.4/79.0% 2.4 A 140 Pa 42/39/34 dB(A)
HRV-D1000(B) 1,000 m³/h 380/210/100 W 82.8/84.0/87.4% 76.0/76.0/80.1% 2.9 A 160 Pa 44/39/33.5 dB(A)
HRV-D1500(B) 1,500 m³/h 680/320/200 W 75.5/78.6/80.2% 69.4/71.2/74.8% 3.8 A 180 Pa 51.5/46.5/41.5 dB(A)
HRV-D2000(B) 2,000 m³/h 950/500/230 W 77.2/79.5/83.4% 74.7/77.0/80.6% 5.7 A 200 Pa 53/48.5/42.5 dB(A)

Notes: three fan speeds on all models; airflow and other single values are measured at high speed. Residential duties normally fall within the first three sizes; the full range is listed to keep the specification table identical across all versions of this product page. Efficiency figures are measured with the standard G4 filter.

Frequently Asked Questions
Q1. Does the residential HRV really need no drain?

The 200 to 1,000 m³/h sizes do not require a condensate drain under normal operating conditions. The 1,500 and 2,000 m³/h sizes do require a PVC drain. Where a space runs at sustained high humidity with a large temperature difference, insulate ducts passing through unconditioned space.

Q2. What ceiling depth do I need?

272 mm plus hanger clearance, so a 300 mm void is the practical minimum. Confirm the mounting method before ordering.

Q3. Which size for a two-bedroom apartment?

Normally 300 to 400 m³/h, subject to the ventilation calculation. A single bedroom or suite normally falls at 200 to 300 m³/h.

Q4. Can one controller run several units in a villa?

Yes. The KJR-27B/E controller manages up to 16 units, and the WDC-120G/WK(A) adds group control where floors or wings are operated separately.

Q5. Is a CO2 sensor included?

No, it is optional. With the CO2 sensor box and the WDC controller, fan speed follows measured CO2 across four thresholds.

Q6. How efficient is it in a cold climate?

Temperature efficiency is 75.5% to 83.5% depending on model and speed, with enthalpy efficiency of 72.1% to 79.6%. The paper core transfers latent heat as well, which matters in winter when indoor air is drier.

Q7. What maintenance does it need?

Filter cleaning at the interval indicated by the controller, vacuuming of the core approximately every two years, and a fan inspection every six months. The core must never be washed with water.

Product Gallery
Related Search Terms
residential heat recovery ventilator home HRV apartment ventilation system villa fresh air system HRV without drain slim ceiling HRV home ERV 272 mm HRV
Sitemap |  Privacy Policy | China Good Quality DC Inverter VRF Supplier. Copyright © 2024-2026 Henan Hongtai HVAC Equipment Co., Ltd. . All Rights Reserved.
+86 18703827920