Heat Recovery Ventilation for Hotels Offices and Schools How to Size a Heat Recovery Ventilator by Room Type HRV for Hotel Guest Rooms 24.5 dB(A) at Low Speed

Heat Recovery Ventilation for Hotels Offices and Schools How to Size a Heat Recovery Ventilator by Room Type HRV for Hotel Guest Rooms 24.5 dB(A) at Low Speed

Detail Information
Place of Origin
China
Brand Name
OEM;MIDEA
Certification
CB,ISO
Product Name:
Midea DC Series HRV
Airflow:
200 M³/h-2000 M³/h
Dimensions L X W X H:
1,195 X 801 X 272 Mm-1,811 X 1,575 X 685 Mm
Net / Gross Weight:
53.6 / 70.6 Kg-208.5 / 245 Kg
Spigot:
144 Mm-346 X 326 Mm
External Static Pressure:
100 Pa-200 Pa
Condensate Drain:
Not Required/PVC Required
Highlight:

HRV for hotel guest rooms

,

heat recovery ventilator sizing guide

,

60Hz air handler 24.5 dB(A)

Product Description
Commercial Heat Recovery Ventilation: One Platform for Hotels, Offices and Schools

Commercial ventilation schedules typically list many different spaces with different airflow requirements: guest rooms, meeting rooms, classrooms, restaurant floors and apartments. Specifying a separate product family for each one multiplies the number of controllers, filters and spare parts carried on the project. The DC Series covers the entire schedule from a single platform, with eight ceiling-mounted sizes spanning 200 to 2,000 m³/h and one control and filter architecture across the full range.

The mapping is straightforward. Sizes from 200 to 500 m³/h serve hotel suites, meeting rooms and apartments, and three of them fit a 272 mm ceiling void. Sizes from 800 to 1,000 m³/h cover offices and classrooms where occupancy is dense and CO2 control pays back fastest. The 1,500 and 2,000 m³/h models handle open-plan floors, restaurants and gyms, where high footfall and odour extraction dominate the design.

Filtration and controls scale with the space rather than the model. G4 filters are standard on both air streams for offices, retail, restaurants and hotels; F7 on the supply side and M5 on the exhaust side meet tighter EU air-quality specifications for schools, clinics and premium offices. Sound pressure down to 24.5 dB(A) at low speed keeps guest rooms and classrooms within acoustic limits, and the same unit that runs on a wired controller in an apartment can be handed to a BMS in an office tower.

Key Selling Points
  • Eight Sizes, One Platform — 200 to 2,000 m³/h covers suites, meeting rooms, classrooms, offices, restaurants and open-plan floors from one product family.
  • Quiet Enough for Guest Rooms — Low speed down to 24.5 dB(A) at 1.5 m below the unit; high speed 53 dB(A) on the largest size.
  • 272 mm Casing for Residential Voids — HRV-D200, D300 and D400 fit 300 mm ceiling voids in apartments and villas.
  • No Drain on Six of Eight Sizes — 200 to 1,000 m³/h models need no condensate line, which simplifies ceilings in hotels and apartments.
  • G4 Standard, F7/M5 Optional — Filtration grade is chosen by space type rather than by model.
  • CO2 Control for Dense Occupancy — Offices, classrooms and meeting rooms benefit most from four-threshold demand control.
  • One Control Architecture — The same controllers, gateways and filter platform apply across all eight sizes.
  • VRF Interlock and BMS Ready — Office and hotel projects can hand ventilation to the building management system without changing product.
Selection by Room Type
Space Typical airflow Models Notes
Hotel guest room, suite 200–300 m³/h HRV-D200, D300 272 mm casing; low speed 25.5–30 dB(A)
Meeting room 200–500 m³/h HRV-D200 to D500 CO2 option suits variable occupancy
Apartment, villa 200–400 m³/h HRV-D200, D300, D400 272 mm casing, no drain required
Office, business park 800–1,000 m³/h HRV-D800, D1000 CO2 control plus BMS gateway
Classroom, training room 800–1,000 m³/h HRV-D800, D1000 F7 supply filter where air-quality class requires
Clinic, healthcare area Per project calculation HRV-D400 to D1000 F7 supply plus M5 exhaust; balanced supply and exhaust
Restaurant, retail floor 1,500–2,000 m³/h HRV-D1500, D2000 PVC drain required; odour extraction
Gym, open-plan floor 1,500–2,000 m³/h HRV-D1500, D2000 PVC drain required; high occupancy

Sizing always follows the project's ventilation calculation. The mapping above reflects common practice across these building types and is not a substitute for design.

Filtration Specification

The standard G4 configuration suits most commercial projects: offices, retail, restaurants and hotels where the goal is energy-efficient ventilation with low pressure drop and the highest heat recovery figures. For projects quoting EU air-quality classes — schools, healthcare, premium offices — the optional F7 filter on the supply side and M5 on the exhaust side raise filtration grade while the DC fans absorb the extra static pressure. Efficiency data for both configurations is published in the engineering manual, so consultants can model either option without derating guesswork.

Application Scenarios
  • Hotels and Resorts — Quiet low-speed operation down to 24.5 dB(A) protects guest sleep, while heat recovery cuts corridor and suite fresh-air costs.
  • Offices and Business Parks — CO2 demand control matches ventilation to real occupancy, and BMS integration simplifies facility management.
  • Schools and Training Centres — F7/M5 filtration options and high fresh-air volumes support classroom air-quality standards.
  • Clinics and Healthcare Areas — Balanced supply and exhaust with high-grade filtration; wash-and-vacuum maintenance suits infection-control regimes.
  • Restaurants and Retail Floors — 1,500–2,000 m³/h sizes handle high footfall and odour extraction with heat recovery.
  • Apartments and Villas — Three 200–400 m³/h models with 272 mm slim bodies fit residential ceiling voids.
Why the Range Fits a Whole Project

A mixed-use building usually needs three or four different airflow sizes at once. Because all eight models share the same controller range, the same filter grades and the same gateway options, the project carries one spare-parts list instead of three. Commissioning follows the same sequence on every unit, and facility staff learn one interface rather than one per space type. On phased handovers, units can be added floor by floor without changing the control architecture.

Technical Data
Model Airflow Input power (H/M/L) Temp. efficiency (H/M/L) Enthalpy efficiency (H/M/L) Current External static pressure Sound pressure (H/M/L)
HRV-D200(B) 200 m³/h 70/45/25 W 79.5/81.1/83.5% 75.0/77.5/79.6% 0.64 A 100 Pa 33/29.5/25.5 dB(A)
HRV-D300(B) 300 m³/h 100/55/35 W 75.5/78.8/82.5% 72.1/75.0/79.3% 0.84 A 90 Pa 36.5/33.5/30 dB(A)
HRV-D400(B) 400 m³/h 110/70/40 W 77.7/79.0/81.3% 73.5/75.3/78.0% 0.97 A 100 Pa 36.5/32/28 dB(A)
HRV-D500(B) 500 m³/h 150/95/50 W 80.6/82.2/85.5% 74.0/76.6/80.5% 1.2 A 90 Pa 36/30.5/24.5 dB(A)
HRV-D800(B) 800 m³/h 320/170/80 W 78.7/82.1/86.8% 72.3/75.4/79.0% 2.4 A 140 Pa 42/39/34 dB(A)
HRV-D1000(B) 1,000 m³/h 380/210/100 W 82.8/84.0/87.4% 76.0/76.0/80.1% 2.9 A 160 Pa 44/39/33.5 dB(A)
HRV-D1500(B) 1,500 m³/h 680/320/200 W 75.5/78.6/80.2% 69.4/71.2/74.8% 3.8 A 180 Pa 51.5/46.5/41.5 dB(A)
HRV-D2000(B) 2,000 m³/h 950/500/230 W 77.2/79.5/83.4% 74.7/77.0/80.6% 5.7 A 200 Pa 53/48.5/42.5 dB(A)

Notes: three fan speeds on all models; single values measured at high speed. Sound pressure measured 1.5 m below the unit. Efficiency figures with the standard G4 filter; F7 plus M5 data published in the engineering manual. Operating range -7 °C to +43 °C, indoor humidity below 80%. Only HRV-D1500 and D2000 require a PVC drain. Power supply 220–240 V, single-phase, 50 Hz on all sizes.

Frequently Asked Questions

Q: How do I choose the right size?

A: Start from the project's ventilation calculation, then map to the nearest model. 200–500 m³/h covers suites, meeting rooms and apartments; 800–1,000 m³/h covers offices and classrooms; 1,500–2,000 m³/h covers open-plan floors, restaurants and gyms.

Q: Which model suits a hotel guest room?

A: HRV-D200 or D300, both 272 mm deep, running at low speed with sound pressure of 25.5 to 30 dB(A). Neither needs a condensate drain, which keeps the corridor ceiling simple.

Q: What airflow does a classroom need?

A: Classroom sizing follows the occupancy calculation, and in practice the 800–1,000 m³/h models cover most teaching spaces. Where an EU air-quality class applies, specify the F7 supply filter.

Q: Should I specify G4 or F7 plus M5?

A: G4 standard for offices, retail, restaurants and hotels. F7 supply and M5 exhaust where the project quotes an EU air-quality class, such as schools, clinics and premium offices.

Q: Do restaurant projects need the drain?

A: The 1,500 and 2,000 m³/h models used on restaurant floors do require a PVC drain connection with slope and trap. Sizes up to 1,000 m³/h need no drain at all.

Q: Can one unit serve several rooms?

A: Yes, where the duct design allows it and the airflow matches. Ducted distribution from one unit usually needs a larger size and careful static pressure budgeting; individual units per room simplify balancing and zoning.

Q: What if the calculated airflow falls between two models?

A: Take the larger model and set the design point at medium speed. Efficiency is higher at lower speed, and the spare capacity covers filter loading and future changes of use.

Related Search Terms
  • heat recovery ventilation hotels
  • hrv for offices
  • classroom ventilation unit
  • restaurant erv
  • apartment heat recovery ventilator
  • hrv selection guide
  • commercial ventilation sizing
  • erv for clinics
Products
PRODUCTS DETAILS
Heat Recovery Ventilation for Hotels Offices and Schools How to Size a Heat Recovery Ventilator by Room Type HRV for Hotel Guest Rooms 24.5 dB(A) at Low Speed
Detail Information
Place of Origin
China
Brand Name
OEM;MIDEA
Certification
CB,ISO
Product Name:
Midea DC Series HRV
Airflow:
200 M³/h-2000 M³/h
Dimensions L X W X H:
1,195 X 801 X 272 Mm-1,811 X 1,575 X 685 Mm
Net / Gross Weight:
53.6 / 70.6 Kg-208.5 / 245 Kg
Spigot:
144 Mm-346 X 326 Mm
External Static Pressure:
100 Pa-200 Pa
Condensate Drain:
Not Required/PVC Required
Highlight

HRV for hotel guest rooms

,

heat recovery ventilator sizing guide

,

60Hz air handler 24.5 dB(A)

Product Description
Commercial Heat Recovery Ventilation: One Platform for Hotels, Offices and Schools

Commercial ventilation schedules typically list many different spaces with different airflow requirements: guest rooms, meeting rooms, classrooms, restaurant floors and apartments. Specifying a separate product family for each one multiplies the number of controllers, filters and spare parts carried on the project. The DC Series covers the entire schedule from a single platform, with eight ceiling-mounted sizes spanning 200 to 2,000 m³/h and one control and filter architecture across the full range.

The mapping is straightforward. Sizes from 200 to 500 m³/h serve hotel suites, meeting rooms and apartments, and three of them fit a 272 mm ceiling void. Sizes from 800 to 1,000 m³/h cover offices and classrooms where occupancy is dense and CO2 control pays back fastest. The 1,500 and 2,000 m³/h models handle open-plan floors, restaurants and gyms, where high footfall and odour extraction dominate the design.

Filtration and controls scale with the space rather than the model. G4 filters are standard on both air streams for offices, retail, restaurants and hotels; F7 on the supply side and M5 on the exhaust side meet tighter EU air-quality specifications for schools, clinics and premium offices. Sound pressure down to 24.5 dB(A) at low speed keeps guest rooms and classrooms within acoustic limits, and the same unit that runs on a wired controller in an apartment can be handed to a BMS in an office tower.

Key Selling Points
  • Eight Sizes, One Platform — 200 to 2,000 m³/h covers suites, meeting rooms, classrooms, offices, restaurants and open-plan floors from one product family.
  • Quiet Enough for Guest Rooms — Low speed down to 24.5 dB(A) at 1.5 m below the unit; high speed 53 dB(A) on the largest size.
  • 272 mm Casing for Residential Voids — HRV-D200, D300 and D400 fit 300 mm ceiling voids in apartments and villas.
  • No Drain on Six of Eight Sizes — 200 to 1,000 m³/h models need no condensate line, which simplifies ceilings in hotels and apartments.
  • G4 Standard, F7/M5 Optional — Filtration grade is chosen by space type rather than by model.
  • CO2 Control for Dense Occupancy — Offices, classrooms and meeting rooms benefit most from four-threshold demand control.
  • One Control Architecture — The same controllers, gateways and filter platform apply across all eight sizes.
  • VRF Interlock and BMS Ready — Office and hotel projects can hand ventilation to the building management system without changing product.
Selection by Room Type
Space Typical airflow Models Notes
Hotel guest room, suite 200–300 m³/h HRV-D200, D300 272 mm casing; low speed 25.5–30 dB(A)
Meeting room 200–500 m³/h HRV-D200 to D500 CO2 option suits variable occupancy
Apartment, villa 200–400 m³/h HRV-D200, D300, D400 272 mm casing, no drain required
Office, business park 800–1,000 m³/h HRV-D800, D1000 CO2 control plus BMS gateway
Classroom, training room 800–1,000 m³/h HRV-D800, D1000 F7 supply filter where air-quality class requires
Clinic, healthcare area Per project calculation HRV-D400 to D1000 F7 supply plus M5 exhaust; balanced supply and exhaust
Restaurant, retail floor 1,500–2,000 m³/h HRV-D1500, D2000 PVC drain required; odour extraction
Gym, open-plan floor 1,500–2,000 m³/h HRV-D1500, D2000 PVC drain required; high occupancy

Sizing always follows the project's ventilation calculation. The mapping above reflects common practice across these building types and is not a substitute for design.

Filtration Specification

The standard G4 configuration suits most commercial projects: offices, retail, restaurants and hotels where the goal is energy-efficient ventilation with low pressure drop and the highest heat recovery figures. For projects quoting EU air-quality classes — schools, healthcare, premium offices — the optional F7 filter on the supply side and M5 on the exhaust side raise filtration grade while the DC fans absorb the extra static pressure. Efficiency data for both configurations is published in the engineering manual, so consultants can model either option without derating guesswork.

Application Scenarios
  • Hotels and Resorts — Quiet low-speed operation down to 24.5 dB(A) protects guest sleep, while heat recovery cuts corridor and suite fresh-air costs.
  • Offices and Business Parks — CO2 demand control matches ventilation to real occupancy, and BMS integration simplifies facility management.
  • Schools and Training Centres — F7/M5 filtration options and high fresh-air volumes support classroom air-quality standards.
  • Clinics and Healthcare Areas — Balanced supply and exhaust with high-grade filtration; wash-and-vacuum maintenance suits infection-control regimes.
  • Restaurants and Retail Floors — 1,500–2,000 m³/h sizes handle high footfall and odour extraction with heat recovery.
  • Apartments and Villas — Three 200–400 m³/h models with 272 mm slim bodies fit residential ceiling voids.
Why the Range Fits a Whole Project

A mixed-use building usually needs three or four different airflow sizes at once. Because all eight models share the same controller range, the same filter grades and the same gateway options, the project carries one spare-parts list instead of three. Commissioning follows the same sequence on every unit, and facility staff learn one interface rather than one per space type. On phased handovers, units can be added floor by floor without changing the control architecture.

Technical Data
Model Airflow Input power (H/M/L) Temp. efficiency (H/M/L) Enthalpy efficiency (H/M/L) Current External static pressure Sound pressure (H/M/L)
HRV-D200(B) 200 m³/h 70/45/25 W 79.5/81.1/83.5% 75.0/77.5/79.6% 0.64 A 100 Pa 33/29.5/25.5 dB(A)
HRV-D300(B) 300 m³/h 100/55/35 W 75.5/78.8/82.5% 72.1/75.0/79.3% 0.84 A 90 Pa 36.5/33.5/30 dB(A)
HRV-D400(B) 400 m³/h 110/70/40 W 77.7/79.0/81.3% 73.5/75.3/78.0% 0.97 A 100 Pa 36.5/32/28 dB(A)
HRV-D500(B) 500 m³/h 150/95/50 W 80.6/82.2/85.5% 74.0/76.6/80.5% 1.2 A 90 Pa 36/30.5/24.5 dB(A)
HRV-D800(B) 800 m³/h 320/170/80 W 78.7/82.1/86.8% 72.3/75.4/79.0% 2.4 A 140 Pa 42/39/34 dB(A)
HRV-D1000(B) 1,000 m³/h 380/210/100 W 82.8/84.0/87.4% 76.0/76.0/80.1% 2.9 A 160 Pa 44/39/33.5 dB(A)
HRV-D1500(B) 1,500 m³/h 680/320/200 W 75.5/78.6/80.2% 69.4/71.2/74.8% 3.8 A 180 Pa 51.5/46.5/41.5 dB(A)
HRV-D2000(B) 2,000 m³/h 950/500/230 W 77.2/79.5/83.4% 74.7/77.0/80.6% 5.7 A 200 Pa 53/48.5/42.5 dB(A)

Notes: three fan speeds on all models; single values measured at high speed. Sound pressure measured 1.5 m below the unit. Efficiency figures with the standard G4 filter; F7 plus M5 data published in the engineering manual. Operating range -7 °C to +43 °C, indoor humidity below 80%. Only HRV-D1500 and D2000 require a PVC drain. Power supply 220–240 V, single-phase, 50 Hz on all sizes.

Frequently Asked Questions

Q: How do I choose the right size?

A: Start from the project's ventilation calculation, then map to the nearest model. 200–500 m³/h covers suites, meeting rooms and apartments; 800–1,000 m³/h covers offices and classrooms; 1,500–2,000 m³/h covers open-plan floors, restaurants and gyms.

Q: Which model suits a hotel guest room?

A: HRV-D200 or D300, both 272 mm deep, running at low speed with sound pressure of 25.5 to 30 dB(A). Neither needs a condensate drain, which keeps the corridor ceiling simple.

Q: What airflow does a classroom need?

A: Classroom sizing follows the occupancy calculation, and in practice the 800–1,000 m³/h models cover most teaching spaces. Where an EU air-quality class applies, specify the F7 supply filter.

Q: Should I specify G4 or F7 plus M5?

A: G4 standard for offices, retail, restaurants and hotels. F7 supply and M5 exhaust where the project quotes an EU air-quality class, such as schools, clinics and premium offices.

Q: Do restaurant projects need the drain?

A: The 1,500 and 2,000 m³/h models used on restaurant floors do require a PVC drain connection with slope and trap. Sizes up to 1,000 m³/h need no drain at all.

Q: Can one unit serve several rooms?

A: Yes, where the duct design allows it and the airflow matches. Ducted distribution from one unit usually needs a larger size and careful static pressure budgeting; individual units per room simplify balancing and zoning.

Q: What if the calculated airflow falls between two models?

A: Take the larger model and set the design point at medium speed. Efficiency is higher at lower speed, and the spare capacity covers filter loading and future changes of use.

Related Search Terms
  • heat recovery ventilation hotels
  • hrv for offices
  • classroom ventilation unit
  • restaurant erv
  • apartment heat recovery ventilator
  • hrv selection guide
  • commercial ventilation sizing
  • erv for clinics
Sitemap |  Privacy Policy | China Good Quality DC Inverter VRF Supplier. Copyright © 2024-2026 Henan Hongtai HVAC Equipment Co., Ltd. . All Rights Reserved.
+86 18703827920